• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4607996)   Today's Articles (2185)   Subscriber (49375)
For: Abdi AJ, Mussmann B, Mackenzie A, Gerke O, Jørgensen GM, Bechsgaard TE, Jensen J, Olsen LB, Andersen PE. Visual Evaluation of Image Quality of a Low Dose 2D/3D Slot Scanner Imaging System Compared to Two Conventional Digital Radiography X-ray Imaging Systems. Diagnostics (Basel) 2021;11:1932. [PMID: 34679630 DOI: 10.3390/diagnostics11101932] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 10/13/2021] [Accepted: 10/15/2021] [Indexed: 11/23/2022]  Open
Number Cited by Other Article(s)
1
Kim NH, Yang BE, Kang SH, Kim YH, Na JY, Kim JE, Byun SH. Preclinical and Preliminary Evaluation of Perceived Image Quality of AI-Processed Low-Dose CBCT Analysis of a Single Tooth. Bioengineering (Basel) 2024;11:576. [PMID: 38927812 PMCID: PMC11200631 DOI: 10.3390/bioengineering11060576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 05/25/2024] [Accepted: 06/05/2024] [Indexed: 06/28/2024]  Open
2
Brage K, Mussmann B, Geijer M, Larsen P, Jensen J. Clinical application of EOS imaging system: a scoping review protocol. JBI Evid Synth 2023;21:1009-1015. [PMID: 36633464 DOI: 10.11124/jbies-22-00213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
3
Afat S, Pjontek R, Nikoubashman O, Kunz WG, Brockmann MA, Ridwan H, Wiesmann M, Clusmann H, Othman AE, Hamou HA. Diagnostic Performance of Whole-Body Ultra-Low-Dose CT for Detection of Mechanical Ventriculoperitoneal Shunt Complications: A Retrospective Analysis. AJNR Am J Neuroradiol 2022;43:1597-1602. [PMID: 36229165 PMCID: PMC9731254 DOI: 10.3174/ajnr.a7672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Accepted: 09/07/2022] [Indexed: 02/01/2023]
4
Correction: Abdi et al. Visual Evaluation of Image Quality of a Low Dose 2D/3D Slot Scanner Imaging System Compared to Two Conventional Digital Radiography X-ray Imaging Systems. Diagnostics 2021, 11, 1932. Diagnostics (Basel) 2022;12:diagnostics12051144. [PMID: 35626454 PMCID: PMC9140508 DOI: 10.3390/diagnostics12051144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Accepted: 04/20/2022] [Indexed: 12/04/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA