1
|
Alieva KN, Golikova MV, Kuznetsova AA, Zinner SH. Fluorescence Microscopy: Determination of Meropenem Activity against Klebsiella pneumoniae. Antibiotics (Basel) 2023; 12:1170. [PMID: 37508266 PMCID: PMC10376291 DOI: 10.3390/antibiotics12071170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2023] [Revised: 06/15/2023] [Accepted: 07/07/2023] [Indexed: 07/30/2023] Open
Abstract
The development and implementation of diagnostic methods that allow rapid assessment of antibiotic activity against pathogenic microorganisms is an important step towards antibiotic therapy optimization and increase in the likelihood of successful treatment outcome. To determine whether fluorescence microscopy with acridine orange can be used for rapid assessment (≤8 h) of the meropenem activity against Klebsiella pneumoniae, six isolates including three OXA-48-carbapenemase-producers were exposed to meropenem at different levels of its concentration (0.5 × MIC, 1 × MIC, 8 or 16 µg/mL) and the changes in the viable counts within 24 h were evaluated using fluorescence microscopy and a control culture method. The approach was to capture the regrowth of bacteria as early as possible. Within the first 8 h fluorescence microscopy allowed to categorize 5 out of 6 K. pneumoniae strains by their meropenem susceptibility (based on the MIC breakpoint of 8 mg/L), but meropenem activity against three isolates, two of which were OXA-48-producers, could not be accurately determined at 8 h. The method proposed in our study requires improvement in terms of accelerating the bacterial growth and regrowth for early meropenem MIC determination. Volume-dependent elevation in meropenem MICs against OXA-48-producers was found and this phenomenon should be studied further.
Collapse
Affiliation(s)
- Kamilla N Alieva
- Department of Pharmacokinetics & Pharmacodynamics, Gause Institute of New Antibiotics, 11 Bolshaya Pirogovskaya Street, 119021 Moscow, Russia
| | - Maria V Golikova
- Department of Pharmacokinetics & Pharmacodynamics, Gause Institute of New Antibiotics, 11 Bolshaya Pirogovskaya Street, 119021 Moscow, Russia
| | - Anastasia A Kuznetsova
- Department of Pharmacokinetics & Pharmacodynamics, Gause Institute of New Antibiotics, 11 Bolshaya Pirogovskaya Street, 119021 Moscow, Russia
| | - Stephen H Zinner
- Department of Medicine, Harvard Medical School, Mount Auburn Hospital, 330 Mount Auburn Street, Cambridge, MA 02138, USA
| |
Collapse
|
2
|
Zhang L, Wang B, Yin G, Wang J, He M, Yang Y, Wang T, Tang T, Yu XA, Tian J. Rapid Fluorescence Sensor Guided Detection of Urinary Tract Bacterial Infections. Int J Nanomedicine 2022; 17:3723-3733. [PMID: 36061124 PMCID: PMC9428933 DOI: 10.2147/ijn.s377575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Accepted: 08/21/2022] [Indexed: 11/23/2022] Open
Abstract
Introduction Urinary tract infections (UTI) are one of the most serious human bacterial infections affecting millions of people every year. Therefore, simple and reliable identification of the urinary tract pathogenic bacteria within a few minutes would be of great significance for diagnosis and treatment of clinical patients with UTIs. In this study, the fluorescence sensor was reported to guide the detection of urinary tract bacterial infections rapidly. Methods The Ami-AuNPs-DNAs sensor was fabricated by the amino-modified Au nanoparticles (Ami-AuNPs) and six DNAs signal molecules, which bound to the urinary tract pathogenic bacteria and generated corresponding response signals. Further, based on the collected response signals, identification was performed by principal component analysis (PCA) and linear discriminant analysis (LDA). The Ami-AuNPs and Ami-AuNPs-DNAs were characterized by transmission electron microscopy, UV−vis absorption spectrum, Fourier transform infrared spectrum, dynamic light scattering and zeta potentials. Thereafter, the Ami-AuNPs-DNAs sensor was used to discriminate and identify five kinds of urinary tract pathogenic bacteria. Moreover, the quantitative analysis performance towards individual bacteria at different concentrations were also evaluated. Results The Ami-AuNPs-DNAs sensor were synthesized successfully in terms of spherical, well-dispersed and uniform in size, which could well discriminate five main urinary tract pathogenic bacteria with unique fingerprint-like patterns and was sufficiently sensitive to determine individual bacteria with a detection limit to 1×107 cfu/mL. Furthermore, the sensor had also been successfully applied to identify bacteria in urine samples collected from clinical UTIs. Conclusion The developed fluorescence sensor could be applied to rapid and accurate discrimination of urinary tract pathogenic bacteria and holds great promise for the diagnosis of the disease caused by bacterial infection.
Collapse
Affiliation(s)
- Lei Zhang
- State Key Laboratory of Natural Medicines, Jiangsu Key Laboratory of TCM Evaluation and Translational Research, School of Traditional Chinese Pharmacy, China Pharmaceutical University, Nanjing, Jiangsu Province, 211198, People’s Republic of China
| | - Bing Wang
- NMPA Key Laboratory for Bioequivalence Research of Generic Drug Evaluation, Shenzhen Institute for Drug Control, Shenzhen, Guangdong Province, 518057, People’s Republic of China
| | - Guo Yin
- NMPA Key Laboratory for Bioequivalence Research of Generic Drug Evaluation, Shenzhen Institute for Drug Control, Shenzhen, Guangdong Province, 518057, People’s Republic of China
| | - Jue Wang
- NMPA Key Laboratory for Bioequivalence Research of Generic Drug Evaluation, Shenzhen Institute for Drug Control, Shenzhen, Guangdong Province, 518057, People’s Republic of China
| | - Ming He
- Dermatology Department, The First Affiliated Hospital of Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou Province, 550002, People’s Republic of China
| | - Yuqi Yang
- School of Basic Medicine, Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou Province, 550002, People’s Republic of China
| | - Tiejie Wang
- NMPA Key Laboratory for Bioequivalence Research of Generic Drug Evaluation, Shenzhen Institute for Drug Control, Shenzhen, Guangdong Province, 518057, People’s Republic of China
| | - Ting Tang
- Dermatology Department, The First Affiliated Hospital of Guizhou University of Traditional Chinese Medicine, Guiyang, Guizhou Province, 550002, People’s Republic of China
| | - Xie-An Yu
- NMPA Key Laboratory for Bioequivalence Research of Generic Drug Evaluation, Shenzhen Institute for Drug Control, Shenzhen, Guangdong Province, 518057, People’s Republic of China
- Correspondence: Xie-An Yu; Jiangwei Tian, Email ;
| | - Jiangwei Tian
- State Key Laboratory of Natural Medicines, Jiangsu Key Laboratory of TCM Evaluation and Translational Research, School of Traditional Chinese Pharmacy, China Pharmaceutical University, Nanjing, Jiangsu Province, 211198, People’s Republic of China
| |
Collapse
|
3
|
Lu Q, Chu K, Dou H, Smith ZJ. A sample-preparation-free, automated, sample-to-answer system for cell counting in human body fluids. Anal Bioanal Chem 2021; 413:5025-5035. [PMID: 34170346 DOI: 10.1007/s00216-021-03466-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2021] [Revised: 06/03/2021] [Accepted: 06/08/2021] [Indexed: 10/21/2022]
Abstract
While many clinical laboratory tests are now highly automated, body fluid cell counting, particularly in low-cellularity samples such as cerebral spinal fluid (CSF), is often performed manually. Here, we report a simple, cost-effective method to obtain white and red blood cell counts from human body fluids such as CSF. The method consists of a compact, automated, and low-cost fluorescence microscope system, coupled to a sample chamber containing all of the necessary reagents in dry form to stain and prepare the sample. Sample focus and scanning are handled automatically, and the acquired multimodal images are automatically analyzed to extract cell counts. Comparison with manual counting on over 200 clinical samples shows excellent agreement. As the system counts a substantially larger image region than a standard manual cell count, we find our sensitivity to extremely low cellularity samples to potentially be higher than the manual gold standard, evidenced by our system recording images of cells in samples whose cell count was registered as "0" by a trained user. Thus, our system holds promise for routine, automated, and sensitive analysis of body fluids whose cellularity extends across a wide dynamic range.
Collapse
Affiliation(s)
- Qiang Lu
- Key Laboratory of Precision Scientific Instrumentation of Anhui Higher Education Institutes, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, 96 Jinzhai Road, Hefei, 230027, Anhui, China
| | - Kaiqin Chu
- Key Laboratory of Precision Scientific Instrumentation of Anhui Higher Education Institutes, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, 96 Jinzhai Road, Hefei, 230027, Anhui, China.,Hefei National Laboratory for Physical Sciences at the Microscale, University of Science and Technology of China, 96 Jinzhai Road, Hefei, 230027, Anhui, China
| | - Hu Dou
- Department of Clinical Laboratory, Ministry of Education Key Laboratory of Child Development and Disorders, Key Laboratory of Pediatrics in Chongqing, Chongqing International Science and Technology Cooperation Center for Child Development and Disorders, Children's Hospital of Chongqing Medical University, 136 Zhongshan 2nd Road, Chongqing, 400014, China.
| | - Zachary J Smith
- Key Laboratory of Precision Scientific Instrumentation of Anhui Higher Education Institutes, Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, 96 Jinzhai Road, Hefei, 230027, Anhui, China.
| |
Collapse
|
4
|
Soares JMD, Abreu REF, Costa MMD, Melo NFD, Oliveira HPD. Investigation of Lactobacillus paracasei encapsulation in electrospun fibers of Eudragit® L100. POLIMEROS 2020. [DOI: 10.1590/0104-1428.03020] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Affiliation(s)
| | | | - Mateus Matiuzzi da Costa
- Universidade Federal Rural de Pernambuco, Brasil; Universidade Federal do Vale do São Francisco, Brasil
| | | | | |
Collapse
|