1
|
Chang C, Piao Y, Zhang M, Liu Y, Du M, Yang M, Mei T, Wu C, Wang Y, Chen X, Zeng GQ, Zhang X. Evaluation of tolerability and safety of transcranial electrical stimulation with gel particle electrodes in healthy subjects. Front Psychiatry 2024; 15:1441533. [PMID: 39606007 PMCID: PMC11599605 DOI: 10.3389/fpsyt.2024.1441533] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Accepted: 10/16/2024] [Indexed: 11/29/2024] Open
Abstract
Background With the advancement of transcranial electrical stimulation (tES) technology, an increasing number of stimulation devices and treatment protocols have emerged. However, safety and tolerability remain critical concerns before new strategies can be implemented. Particularly, the use of gel particle electrodes brings new challenges to the safety and tolerability of tES, which hinders its widespread adoption and further research. Objective Our study utilized a specially designed and validated transcranial electrical stimulation stimulator along with preconfigured gel particle electrodes placed at F3 and F4 in the prefrontal lobes. We aimed to assess the tolerance and safety of these electrodes in healthy subjects by administering different durations and types of tES. Methods Each participant underwent ten sessions of either transcranial direct current stimulation (tDCS) or transcranial alternating current stimulation (tACS), with session durations varying. In the experiment, we collected various measurement data from participants, including self-report questionnaire data and behavioral keystroke data. Tolerability was evaluated through adverse events (AEs), the relationship of adverse events with tES (AEs-rela), the Self-Rating Anxiety Scale (SAS), and the Visual Analog Mood Scale-Revised (VAMS-R). Safety was assessed using the Visual Analog Scale (VAS), the Skin Sensation Rating (SSR), Montreal Cognitive Assessment (MoCA), and Stroop task. These data were analyzed to determine the impact of different parameters on the tolerability and safety of tES. Results There were no significant changes in the results of the MoCA and SAS scales before and after the experiment. However, significant differences were observed in VAS, SSR, AEs, and AEs-rela between tDCS and tACS. Additionally, fatigue increased, and energy levels decreased on VAMS-R with longer durations. No significant differences were found in other neuropsychological tests. Conclusion Our study revealed significant differences in tolerability and safety between tDCS and tACS, underscoring the importance of considering the stimulation type when evaluating these factors. Although tolerance and safety did not vary significantly across different stimulation durations in this study, future research may benefit from exploring shorter durations to further assess tolerability and safety efficiently.
Collapse
Affiliation(s)
- Chuangchuang Chang
- Application Technology Center of Physical Therapy to Brain Disorders, Institute of Advanced Technology, University of Science & Technology of China, Hefei, China
| | - Yi Piao
- Application Technology Center of Physical Therapy to Brain Disorders, Institute of Advanced Technology, University of Science & Technology of China, Hefei, China
| | - Mingsong Zhang
- Application Technology Center of Physical Therapy to Brain Disorders, Institute of Advanced Technology, University of Science & Technology of China, Hefei, China
| | - Yan Liu
- Application Technology Center of Physical Therapy to Brain Disorders, Institute of Advanced Technology, University of Science & Technology of China, Hefei, China
| | - Minglei Du
- School of Biomedical Engineering, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, China
| | - Miao Yang
- Application Technology Center of Physical Therapy to Brain Disorders, Institute of Advanced Technology, University of Science & Technology of China, Hefei, China
| | - Tianyuan Mei
- Application Technology Center of Physical Therapy to Brain Disorders, Institute of Advanced Technology, University of Science & Technology of China, Hefei, China
| | - Chengkai Wu
- Application Technology Center of Physical Therapy to Brain Disorders, Institute of Advanced Technology, University of Science & Technology of China, Hefei, China
| | - Yan Wang
- Division of Life Science and Medicine, University of Science & Technology of China, Hefei, China
| | - Xueli Chen
- Department of Radiology, the First Affiliated Hospital of USTC, Hefei National Research Center for Physical Sciences at the Microscale and School of Life Science, Division of Life Science and Medicine, University of Science & Technology of China (USTC), Hefei, China
| | - Ginger Qinghong Zeng
- Application Technology Center of Physical Therapy to Brain Disorders, Institute of Advanced Technology, University of Science & Technology of China, Hefei, China
| | - Xiaochu Zhang
- Application Technology Center of Physical Therapy to Brain Disorders, Institute of Advanced Technology, University of Science & Technology of China, Hefei, China
- Key Laboratory of Brain-Machine Intelligence for Information Behavior (Ministry of Education and Shanghai), School of Business and Management, Shanghai International Studies University, Shanghai, China
- Institute of Health and Medicine, Hefei Comprehensive Science Center, Hefei, China
- Business School, Guizhou Education University, Guiyang, China
| |
Collapse
|
2
|
Ma Y, Gong A, Nan W, Ding P, Wang F, Fu Y. Personalized Brain-Computer Interface and Its Applications. J Pers Med 2022; 13:46. [PMID: 36675707 PMCID: PMC9861730 DOI: 10.3390/jpm13010046] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2022] [Revised: 12/19/2022] [Accepted: 12/20/2022] [Indexed: 12/28/2022] Open
Abstract
Brain-computer interfaces (BCIs) are a new technology that subverts traditional human-computer interaction, where the control signal source comes directly from the user's brain. When a general BCI is used for practical applications, it is difficult for it to meet the needs of different individuals because of the differences among individual users in physiological and mental states, sensations, perceptions, imageries, cognitive thinking activities, and brain structures and functions. For this reason, it is necessary to customize personalized BCIs for specific users. So far, few studies have elaborated on the key scientific and technical issues involved in personalized BCIs. In this study, we will focus on personalized BCIs, give the definition of personalized BCIs, and detail their design, development, evaluation methods and applications. Finally, the challenges and future directions of personalized BCIs are discussed. It is expected that this study will provide some useful ideas for innovative studies and practical applications of personalized BCIs.
Collapse
Affiliation(s)
- Yixin Ma
- Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming 650500, China
- Brain Cognition and Brain-Computer Intelligence Integration Group, Kunming University of Science and Technology, Kunming 650500, China
| | - Anmin Gong
- School of Information Engineering, Chinese People’s Armed Police Force Engineering University, Xian 710086, China
| | - Wenya Nan
- Department of Psychology, College of Education, Shanghai Normal University, Shanghai 200234, China
| | - Peng Ding
- Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming 650500, China
- Brain Cognition and Brain-Computer Intelligence Integration Group, Kunming University of Science and Technology, Kunming 650500, China
| | - Fan Wang
- Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming 650500, China
- Brain Cognition and Brain-Computer Intelligence Integration Group, Kunming University of Science and Technology, Kunming 650500, China
| | - Yunfa Fu
- Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming 650500, China
- Brain Cognition and Brain-Computer Intelligence Integration Group, Kunming University of Science and Technology, Kunming 650500, China
| |
Collapse
|
3
|
Liu J, Lin S, Li W, Zhao Y, Liu D, He Z, Wang D, Lei M, Hong B, Wu H. Ten-Hour Stable Noninvasive Brain-Computer Interface Realized by Semidry Hydrogel-Based Electrodes. RESEARCH 2022; 2022:9830457. [PMID: 35356767 PMCID: PMC8933689 DOI: 10.34133/2022/9830457] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/28/2021] [Accepted: 02/13/2022] [Indexed: 01/31/2023]
Abstract
Noninvasive brain-computer interface (BCI) has been extensively studied from many aspects in the past decade. In order to broaden the practical applications of BCI technique, it is essential to develop electrodes for electroencephalogram (EEG) collection with advanced characteristics such as high conductivity, long-term effectiveness, and biocompatibility. In this study, we developed a silver-nanowire/PVA hydrogel/melamine sponge (AgPHMS) semidry EEG electrode for long-lasting monitoring of EEG signal. Benefiting from the water storage capacity of PVA hydrogel, the electrolyte solution can be continuously released to the scalp-electrode interface during used. The electrolyte solution can infiltrate the stratum corneum and reduce the scalp-electrode impedance to 10 kΩ-15 kΩ. The flexible structure enables the electrode with mechanical stability, increases the wearing comfort, and reduces the scalp-electrode gap to reduce contact impedance. As a result, a long-term BCI application based on measurements of motion-onset visual evoked potentials (mVEPs) shows that the 3-hour BCI accuracy of the new electrode (77% to 100%) is approximately the same as that of conventional electrodes supported by a conductive gel during the first hour. Furthermore, the BCI system based on the new electrode can retain low contact impedance for 10 hours on scalp, which greatly improved the ability of BCI technique.
Collapse
Affiliation(s)
- Junchen Liu
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China
- State Key Laboratory of Information Photonics and Optical Communications and School of Science, Beijing University of Posts and Telecommunications, Beijing 100876, China
| | - Sen Lin
- State Key Laboratory of Information Photonics and Optical Communications and School of Science, Beijing University of Posts and Telecommunications, Beijing 100876, China
| | - Wenzheng Li
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Yanzhen Zhao
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China
| | - Dingkun Liu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Zhaofeng He
- School of Artificial, Beijing University of Posts and Telecommunications, Beijing 100084, China
| | - Dong Wang
- School of Biomedical Engineering, Hainan University, Haikou 570228, China
| | - Ming Lei
- State Key Laboratory of Information Photonics and Optical Communications and School of Science, Beijing University of Posts and Telecommunications, Beijing 100876, China
| | - Bo Hong
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Hui Wu
- State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing 100084, China
| |
Collapse
|
4
|
Liang L, Bin G, Chen X, Wang Y, Gao S, Gao X. Optimizing a left and right visual field biphasic stimulation paradigm for SSVEP-based BCIs with hairless region behind the ear. J Neural Eng 2021; 18. [PMID: 34875637 DOI: 10.1088/1741-2552/ac40a1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Accepted: 12/07/2021] [Indexed: 11/12/2022]
Abstract
Objective.Steady-state visual evoked potential (SSVEP) based brain-computer interface (BCI) has the characteristics of fast communication speed, high stability, and wide applicability, thus it has been widely studied. With the rapid development in paradigm, algorithm, and system design, SSVEP-BCI is gradually applied in clinical and real-life scenarios. In order to improve the ease of use of the SSVEP-BCI system, many studies have been focusing on developing it on the hairless area, but due to the lack of redesigning the stimulation paradigm to better adapt to the new area, the electroencephalography response in the hairless area is worse than occipital region.Approach. This study first proposed a phase difference estimation method based on stimulating the left and right visual field separately, then developed and optimized a left and right visual field biphasic stimulation paradigm for SSVEP-based BCIs with hairless region behind the ear.Main results.In the 12-target online experiment, after a short model estimation training, all 16 subjects used their best stimulus condition. The paradigm designed in this study can increase the proportion of applicable subjects for the behind-ear SSVEP-BCI system from 58.3% to 75% and increase the accuracy from 74.6 ± 20.0% (the existing best SSVEP stimulus with hairless region behind the ear) to 84.2±14.7%, and the information transfer rate from 14.2±6.4 bits min-1to 17.8±5.7 bits min-1.Significance.These results demonstrated that the proposed paradigm can effectively improve the BCI performance using the signal from the hairless region behind the ear, compared with the standard SSVEP stimulation paradigm.
Collapse
Affiliation(s)
- Liyan Liang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, People's Republic of China
| | - Guangyu Bin
- Department of Biomedical Engineering, Beijing University of Technology, Beijing 100124, People's Republic of China
| | - Xiaogang Chen
- Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin 300192, People's Republic of China
| | - Yijun Wang
- State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, People's Republic of China
| | - Shangkai Gao
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, People's Republic of China
| | - Xiaorong Gao
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, People's Republic of China
| |
Collapse
|
5
|
Abstract
In recent years, the accurate and real-time classification of electroencephalogram (EEG) signals has drawn increasing attention in the application of brain-computer interface technology (BCI). Supervised methods used to classify EEG signals have gotten satisfactory results. However, unlabeled samples are more frequent than labeled samples, so how to simultaneously utilize limited labeled samples and many unlabeled samples becomes a research hotspot. In this paper, we propose a new graph-based semi-supervised broad learning system (GSS-BLS), which combines the graph label propagation method to obtain pseudo-labels and then trains the GSS-BLS classifier together with other labeled samples. Three BCI competition datasets are used to assess the GSS-BLS approach and five comparison algorithms: BLS, ELM, HELM, LapSVM and SMIR. The experimental results show that GSS-BLS achieves satisfying Cohen’s kappa values in three datasets. GSS-BLS achieves the better results of each subject in the 2-class and 4-class datasets and has significant improvements compared with original BLS except subject C6. Therefore, the proposed GSS-BLS is an effective semi-supervised algorithm for classifying EEG signals.
Collapse
|