1
|
Escalona O, Cullen N, Weli I, McCallan N, Ng KY, Finlay D. Robust Arm Impedocardiography Signal Quality Enhancement Using Recursive Signal Averaging and Multi-Stage Wavelet Denoising Methods for Long-Term Cardiac Contractility Monitoring Armbands. SENSORS (BASEL, SWITZERLAND) 2023; 23:5892. [PMID: 37447749 DOI: 10.3390/s23135892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/28/2023] [Revised: 06/21/2023] [Accepted: 06/22/2023] [Indexed: 07/15/2023]
Abstract
Impedance cardiography (ICG) is a low-cost, non-invasive technique that enables the clinical assessment of haemodynamic parameters, such as cardiac output and stroke volume (SV). Conventional ICG recordings are taken from the patient's thorax. However, access to ICG vital signs from the upper-arm brachial artery (as an associated surrogate) can enable user-convenient wearable armband sensor devices to provide an attractive option for gathering ICG trend-based indicators of general health, which offers particular advantages in ambulatory long-term monitoring settings. This study considered the upper arm ICG and control Thorax-ICG recordings data from 15 healthy subject cases. A prefiltering stage included a third-order Savitzky-Golay finite impulse response (FIR) filter, which was applied to the raw ICG signals. Then, a multi-stage wavelet-based denoising strategy on a beat-by-beat (BbyB) basis, which was supported by a recursive signal-averaging optimal thresholding adaptation algorithm for Arm-ICG signals, was investigated for robust signal quality enhancement. The performance of the BbyB ICG denoising was evaluated for each case using a 700 ms frame centred on the heartbeat ICG pulse. This frame was extracted from a 600-beat ensemble signal-averaged ICG and was used as the noiseless signal reference vector (gold standard frame). Furthermore, in each subject case, enhanced Arm-ICG and Thorax-ICG above a threshold of correlation of 0.95 with the noiseless vector enabled the analysis of beat inclusion rate (BIR%), yielding an average of 80.9% for Arm-ICG and 100% for Thorax-ICG, and BbyB values of the ICG waveform feature metrics A, B, C and VET accuracy and precision, yielding respective error rates (ER%) of 0.83%, 11.1%, 3.99% and 5.2% for Arm-IG, and 0.41%, 3.82%, 1.66% and 1.25% for Thorax-ICG, respectively. Hence, the functional relationship between ICG metrics within and between the arm and thorax recording modes could be characterised and the linear regression (Arm-ICG vs. Thorax-ICG) trends could be analysed. Overall, it was found in this study that recursive averaging, set with a 36 ICG beats buffer size, was the best Arm-ICG BbyB denoising process, with an average of less than 3.3% in the Arm-ICG time metrics error rate. It was also found that the arm SV versus thorax SV had a linear regression coefficient of determination (R2) of 0.84.
Collapse
Affiliation(s)
- Omar Escalona
- School of Engineering, Ulster University, Belfast BT15 1AP, UK
| | - Nicole Cullen
- School of Engineering, Ulster University, Belfast BT15 1AP, UK
| | - Idongesit Weli
- School of Engineering, Ulster University, Belfast BT15 1AP, UK
| | - Niamh McCallan
- School of Engineering, Ulster University, Belfast BT15 1AP, UK
| | - Kok Yew Ng
- School of Engineering, Ulster University, Belfast BT15 1AP, UK
| | - Dewar Finlay
- School of Engineering, Ulster University, Belfast BT15 1AP, UK
| |
Collapse
|
2
|
Escalona O, Mukhtar S, McEneaney D, Finlay D. Armband Sensors Location Assessment for Left Arm-ECG Bipolar Leads Waveform Components Discovery Tendencies around the MUAC Line. SENSORS (BASEL, SWITZERLAND) 2022; 22:7240. [PMID: 36236340 PMCID: PMC9572383 DOI: 10.3390/s22197240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/16/2022] [Accepted: 09/22/2022] [Indexed: 06/16/2023]
Abstract
Sudden cardiac death (SCD) risk can be reduced by early detection of short-lived and transient cardiac arrhythmias using long-term electrocardiographic (ECG) monitoring. Early detection of ventricular arrhythmias can reduce the risk of SCD by allowing appropriate interventions. Long-term continuous ECG monitoring, using a non-invasive armband-based wearable device is an appealing solution for detecting early heart rhythm abnormalities. However, there is a paucity of understanding on the number and best bipolar ECG electrode pairs axial orientation around the left mid-upper arm circumference (MUAC) for such devices. This study addresses the question on the best axial orientation of ECG bipolar electrode pairs around the left MUAC in non-invasive armband-based wearable devices, for the early detection of heart rhythm abnormalities. A total of 18 subjects with almost same BMI values in the WASTCArD arm-ECG database were selected to assess arm-ECG bipolar leads quality using proposed metrics of relative (normalized) signal strength measurement, arm-ECG detection performance of the main ECG waveform event component (QRS) and heart-rate variability (HRV) in six derived bipolar arm ECG-lead sensor pairs around the armband circumference, having regularly spaced axis angles (at 30° steps) orientation. The analysis revealed that the angular range from -30° to +30°of arm-lead sensors pair axis orientation around the arm, including the 0° axis (which is co-planar to chest plane), provided the best orientation on the arm for reasonably good QRS detection; presenting the highest sensitivity (Se) median value of 93.3%, precision PPV median value at 99.6%; HRV RMS correlation (p) of 0.97 and coefficient of determination (R2) of 0.95 with HRV gold standard values measured in the standard Lead-I ECG.
Collapse
Affiliation(s)
- Omar Escalona
- School of Engineering, Ulster University, Newtownabbey BT37 0QB, UK
| | - Sephorah Mukhtar
- School of Engineering, Ulster University, Newtownabbey BT37 0QB, UK
| | | | - Dewar Finlay
- School of Engineering, Ulster University, Newtownabbey BT37 0QB, UK
| |
Collapse
|
3
|
Chehbani A, Sahuguede S, Julien-Vergonjanne A. RF-Free infant ECG monitoring: Performance and signal quality assessment. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:2891-2897. [PMID: 36086251 DOI: 10.1109/embc48229.2022.9871387] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Existing Electrocardiogram (ECG) systems are either wired or based on radiofrequency (RF) wireless devices when remote transmission is needed. However, the use of radiofrequencies has limitations especially for sensitive populations such as newborns and infants. In addition, due to electromagnetic interference problems, impairments in the RF transmission of the ECG signal can lead to diagnostic errors. To answer these problems, we propose in this article, an optical wireless monitoring system, using an infrared link between an ECG sensor placed on a baby's chest and receivers placed on the ceiling of a pediatric room. In addition, it is assumed that the infant can move around in his bed. Our main contribution is the evaluation of the quality of the ECG signal transmitted by the proposed system, in terms of classic Signal to Noise Ratio (SNR) and Bit Error Rate (BER) metrics but also in terms of Signal Quality Indexes (SQIs) calculated from the characteristics of the received ECG signal. Results show the ability to perform wireless infant ECG monitoring using the Optical Wireless Communication (OWC) with satisfactory quality for optimum power.
Collapse
|
4
|
Guess M, Zavanelli N, Yeo WH. Recent Advances in Materials and Flexible Sensors for Arrhythmia Detection. MATERIALS 2022; 15:ma15030724. [PMID: 35160670 PMCID: PMC8836661 DOI: 10.3390/ma15030724] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Revised: 01/06/2022] [Accepted: 01/16/2022] [Indexed: 12/24/2022]
Abstract
Arrhythmias are one of the leading causes of death in the United States, and their early detection is essential for patient wellness. However, traditional arrhythmia diagnosis by expert evaluation from intermittent clinical examinations is time-consuming and often lacks quantitative data. Modern wearable sensors and machine learning algorithms have attempted to alleviate this problem by providing continuous monitoring and real-time arrhythmia detection. However, current devices are still largely limited by the fundamental mismatch between skin and sensor, giving way to motion artifacts. Additionally, the desirable qualities of flexibility, robustness, breathability, adhesiveness, stretchability, and durability cannot all be met at once. Flexible sensors have improved upon the current clinical arrhythmia detection methods by following the topography of skin and reducing the natural interface mismatch between cardiac monitoring sensors and human skin. Flexible bioelectric, optoelectronic, ultrasonic, and mechanoelectrical sensors have been demonstrated to provide essential information about heart-rate variability, which is crucial in detecting and classifying arrhythmias. In this review, we analyze the current trends in flexible wearable sensors for cardiac monitoring and the efficacy of these devices for arrhythmia detection.
Collapse
Affiliation(s)
- Matthew Guess
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA; (M.G.); (N.Z.)
- Center for Human-Centric Interfaces and Engineering, Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Nathan Zavanelli
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA; (M.G.); (N.Z.)
- Center for Human-Centric Interfaces and Engineering, Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Woon-Hong Yeo
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA; (M.G.); (N.Z.)
- Center for Human-Centric Interfaces and Engineering, Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, GA 30332, USA
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
- Parker H. Petit Institute for Bioengineering and Biosciences, Neural Engineering Center, Institute for Materials, Institute for Robotics and Intelligent Machines, Georgia Institute of Technology, Atlanta, GA 30332, USA
- Correspondence: ; Tel.: +1-404-385-5710
| |
Collapse
|
5
|
Zhang L, Liu J. Research Progress of ECG Monitoring Equipment and Algorithms Based on Polymer Materials. MICROMACHINES 2021; 12:1282. [PMID: 34832693 PMCID: PMC8624836 DOI: 10.3390/mi12111282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Revised: 10/17/2021] [Accepted: 10/19/2021] [Indexed: 11/22/2022]
Abstract
Heart diseases such as myocardial ischemia (MI) are the main causes of human death. The prediction of MI and arrhythmia is an effective method for the early detection, diagnosis, and treatment of heart disease. For the rapid detection of arrhythmia and myocardial ischemia, the electrocardiogram (ECG) is widely used in clinical diagnosis, and its detection equipment and algorithm are constantly optimized. This paper introduces the current progress of portable ECG monitoring equipment, including the use of polymer material sensors and the use of deep learning algorithms. First, it introduces the latest portable ECG monitoring equipment and the polymer material sensor it uses and then focuses on reviewing the progress of detection algorithms. We mainly introduce the basic structure of existing deep learning methods and enumerate the internationally recognized ECG datasets. This paper outlines the deep learning algorithms used for ECG diagnosis, compares the prediction results of different classifiers, and summarizes two existing problems of ECG detection technology: imbalance of categories and high computational overhead. Finally, we put forward the development direction of using generative adversarial networks (GAN) to improve the quality of the ECG database and lightweight ECG diagnosis algorithm to adapt to portable ECG monitoring equipment.
Collapse
Affiliation(s)
| | - Jihong Liu
- College of Information Science and Engineering, Northeastern University, Shenyang 110819, China;
| |
Collapse
|
6
|
Anytime ECG Monitoring through the Use of a Low-Cost, User-Friendly, Wearable Device. SENSORS 2021; 21:s21186036. [PMID: 34577247 PMCID: PMC8473282 DOI: 10.3390/s21186036] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 09/03/2021] [Accepted: 09/06/2021] [Indexed: 11/16/2022]
Abstract
Every year cardiovascular diseases kill the highest number of people worldwide. Among these, pathologies characterized by sporadic symptoms, such as atrial fibrillation, are difficult to be detected as state-of-the-art solutions, e.g., 12-leads electrocardiogram (ECG) or Holter devices, often fail to tackle these kinds of pathologies. Many portable devices have already been proposed, both in literature and in the market. Unfortunately, they all miss relevant features: they are either not wearable or wireless and their usage over a long-term period is often unsuitable. In addition, the quality of recordings is another key factor to perform reliable diagnosis. The ECG WATCH is a device designed for targeting all these issues. It is inexpensive, wearable (size of a watch), and can be used without the need for any medical expertise about positioning or usage. It is non-invasive, it records single-lead ECG in just 10 s, anytime, anywhere, without the need to physically travel to hospitals or cardiologists. It can acquire any of the three peripheral leads; results can be shared with physicians by simply tapping a smartphone app. The ECG WATCH quality has been tested on 30 people and has successfully compared with an electrocardiograph and an ECG simulator, both certified. The app embeds an algorithm for automatically detecting atrial fibrillation, which has been successfully tested with an official ECG simulator on different severity of atrial fibrillation. In this sense, the ECG WATCH is a promising device for anytime cardiac health monitoring.
Collapse
|
7
|
Development of an Optical System for Non-Contact Type Measurement of Heart Rate and Heart Rate Variability. APPLIED SYSTEM INNOVATION 2021. [DOI: 10.3390/asi4030048] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Self-mixing optical coherent detection is a non-contact measurement technique which provides accurate information about the vibration frequency of any test subject. In this research, novel designs of optical homodyne and heterodyne detection techniques are explained. Homodyne and heterodyne setups are used for measuring the frequency of the modulated optical signal. This technique works on the principle of the optical interferometer, which provides a coherent detection of two self-mixing beams. In the optical homodyne technique, one of the two beams receives direct modulation from the vibration frequency of the test subject. In the optical heterodyne detection technique, one of the two optical beams is subjected to modulation by an acousto-optics modulator before becoming further modulated by the vibration frequency of the test subject. These two optical signals form an interference pattern that contains the information of the vibration frequency. The measurement of cardiovascular signals, such as heart rate and heart rate variability, are performed with both homodyne and heterodyne techniques. The optical coherent detection technique provides a high accuracy for the measurement of heart period and heart rate variability. The vibrocardiogram output obtained from both techniques are compared for different heart rate values. Results obtained from both optical homodyne and heterodyne detection techniques are compared and found to be within 1% of deviation value. The results obtained from both the optical techniques have a deviation of less than 1 beat per minute from their corresponding ECG values.
Collapse
|
8
|
Localized Bioimpedance Measurements with the MAX3000x Integrated Circuit: Characterization and Demonstration. SENSORS 2021; 21:s21093013. [PMID: 33923037 PMCID: PMC8123364 DOI: 10.3390/s21093013] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 04/15/2021] [Accepted: 04/20/2021] [Indexed: 01/24/2023]
Abstract
The commercial availability of integrated circuits with bioimpedance sensing functionality is advancing the opportunity for practical wearable systems that monitor the electrical impedance properties of tissues to identify physiological features in support of health-focused applications. This technical note characterizes the performance of the MAX3000x (resistance/reactance accuracy, power modes, filtering, gains) and is available for on-board processing (electrode detection) for localized bioimpedance measurements. Measurements of discrete impedances that are representative of localized tissue bioimpedance support that this IC has a relative error of <10% for the resistance component of complex impedance measurements, but can also measure relative alterations in the 250 mΩ range. The application of the MAX3000x for monitoring localized bicep tissues during activity is presented to highlight its functionality, as well as its limitations, for multi-frequency measurements. This device is a very-small-form-factor single-chip solution for measuring multi-frequency bioimpedance with significant on-board processing with potential for wearable applications.
Collapse
|
9
|
Recent Progress in Flexible Wearable Sensors for Vital Sign Monitoring. SENSORS 2020; 20:s20144009. [PMID: 32707637 PMCID: PMC7411849 DOI: 10.3390/s20144009] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 07/10/2020] [Accepted: 07/14/2020] [Indexed: 12/20/2022]
Abstract
With the development of flexible electronic materials, as well as the wide development and application of smartphones, the cloud, and wireless systems, flexible wearable sensor technology has a significant and far-reaching impact on the realization of personalized medical care and the reform of the consumer market in the future. However, due to the high requirements for accuracy, reliability, low power consumption, and less data error, the development of these potential areas is full of challenges. In order to solve these problems, this review mainly searches the literature from 2008 to May 2020, based on the PRISMA process. Based on them, this paper reviews the latest research progress of new flexible materials and different types of sensors for monitoring vital signs (including electrophysiological signals, body temperature, and respiratory frequency) in recent years. These materials and sensors can help realize accurate signal detection based on comfortable and sustainable observation, and may likely be applied to future daily clothing.
Collapse
|
10
|
Smart Environments and Social Robots for Age-Friendly Integrated Care Services. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17113801. [PMID: 32471108 PMCID: PMC7312538 DOI: 10.3390/ijerph17113801] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 05/25/2020] [Accepted: 05/26/2020] [Indexed: 12/13/2022]
Abstract
The world is facing major societal challenges because of an aging population that is putting increasing pressure on the sustainability of care. While demand for care and social services is steadily increasing, the supply is constrained by the decreasing workforce. The development of smart, physical, social and age-friendly environments is identified by World Health Organization (WHO) as a key intervention point for enabling older adults, enabling them to remain as much possible in their residences, delay institutionalization, and ultimately, improve quality of life. In this study, we survey smart environments, machine learning and robot assistive technologies that can offer support for the independent living of older adults and provide age-friendly care services. We describe two examples of integrated care services that are using assistive technologies in innovative ways to assess and deliver of timely interventions for polypharmacy management and for social and cognitive activity support in older adults. We describe the architectural views of these services, focusing on details about technology usage, end-user interaction flows and data models that are developed or enhanced to achieve the envisioned objective of healthier, safer, more independent and socially connected older people.
Collapse
|
11
|
A Pipeline for Adaptive Filtering and Transformation of Noisy Left-Arm ECG to Its Surrogate Chest Signal. ELECTRONICS 2020. [DOI: 10.3390/electronics9050866] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The performance of a low-power single-lead armband in generating electrocardiogram (ECG) signals from the chest and left arm was validated against a BIOPAC MP160 benchtop system in real-time. The filtering performance of three adaptive filtering algorithms, namely least mean squares (LMS), recursive least squares (RLS), and extended kernel RLS (EKRLS) in removing white (W), power line interference (PLI), electrode movement (EM), muscle artifact (MA), and baseline wandering (BLW) noises from the chest and left-arm ECG was evaluated with respect to the mean squared error (MSE). Filter parameters of the used algorithms were adjusted to ensure optimal filtering performance. LMS was found to be the most effective adaptive filtering algorithm in removing all noises with minimum MSE. However, for removing PLI with a maximal signal-to-noise ratio (SNR), RLS showed lower MSE values than LMS when the step size was set to 1 × 10−5. We proposed a transformation framework to convert the denoised left-arm and chest ECG signals to their low-MSE and high-SNR surrogate chest signals. With wide applications in wearable technologies, the proposed pipeline was found to be capable of establishing a baseline for comparing left-arm signals with original chest signals, getting one step closer to making use of the left-arm ECG in clinical cardiac evaluations.
Collapse
|
12
|
Serhani MA, T. El Kassabi H, Ismail H, Nujum Navaz A. ECG Monitoring Systems: Review, Architecture, Processes, and Key Challenges. SENSORS (BASEL, SWITZERLAND) 2020; 20:E1796. [PMID: 32213969 PMCID: PMC7147367 DOI: 10.3390/s20061796] [Citation(s) in RCA: 63] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Revised: 03/17/2020] [Accepted: 03/19/2020] [Indexed: 02/01/2023]
Abstract
Health monitoring and its related technologies is an attractive research area. The electrocardiogram (ECG) has always been a popular measurement scheme to assess and diagnose cardiovascular diseases (CVDs). The number of ECG monitoring systems in the literature is expanding exponentially. Hence, it is very hard for researchers and healthcare experts to choose, compare, and evaluate systems that serve their needs and fulfill the monitoring requirements. This accentuates the need for a verified reference guiding the design, classification, and analysis of ECG monitoring systems, serving both researchers and professionals in the field. In this paper, we propose a comprehensive, expert-verified taxonomy of ECG monitoring systems and conduct an extensive, systematic review of the literature. This provides evidence-based support for critically understanding ECG monitoring systems' components, contexts, features, and challenges. Hence, a generic architectural model for ECG monitoring systems is proposed, an extensive analysis of ECG monitoring systems' value chain is conducted, and a thorough review of the relevant literature, classified against the experts' taxonomy, is presented, highlighting challenges and current trends. Finally, we identify key challenges and emphasize the importance of smart monitoring systems that leverage new technologies, including deep learning, artificial intelligence (AI), Big Data and Internet of Things (IoT), to provide efficient, cost-aware, and fully connected monitoring systems.
Collapse
Affiliation(s)
- Mohamed Adel Serhani
- Department of Information Systems and Security, College of Information Technology, UAE University, Al Ain 15551, United Arab Emirates;
| | - Hadeel T. El Kassabi
- Department of Computer Science and Software Engineering, College of Information Technology, UAE University, Al Ain 15551, United Arab Emirates; (H.T.E.K.)
| | - Heba Ismail
- Department of Computer Science and Software Engineering, College of Information Technology, UAE University, Al Ain 15551, United Arab Emirates; (H.T.E.K.)
| | - Alramzana Nujum Navaz
- Department of Information Systems and Security, College of Information Technology, UAE University, Al Ain 15551, United Arab Emirates;
| |
Collapse
|