1
|
Indoor Air Quality Assessment: Comparison of Ventilation Scenarios for Retrofitting Classrooms in a Hot Climate. ENERGIES 2019. [DOI: 10.3390/en12244607] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Current energy efficiency policies in buildings foster the promotion of energy retrofitting of the existing stock. In southern Spain, the most extensive public sector is that of educational buildings, which is especially subject to significant internal loads due to high occupancy. A large fraction of the energy retrofit strategies conducted to date have focused on energy aspects and indoor thermal comfort, repeatedly disregarding indoor air quality criteria. This research assesses indoor air quality in a school located in the Mediterranean area, with the objective of promoting different ventilation scenarios, based on occupancy patterns and carbon dioxide levels monitored on site. Results show that manual ventilation cannot guarantee minimum indoor quality levels following current standards. A constant ventilation based on CO2 levels allows 15% more thermal comfort hours a year to be reached, compared to CO2-based optimized demand-controlled ventilation. Nevertheless, the latter ensures 35% annual energy savings, compared to a constant CO2-based ventilation, and 37% more annual energy savings over that of a constant ventilation rate of outdoor air per person.
Collapse
|
2
|
Predicting the Impact of Climate Change on Thermal Comfort in A Building Category: The Case of Linear-type Social Housing Stock in Southern Spain. ENERGIES 2019. [DOI: 10.3390/en12122238] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The Climate Change scenario projected by the IPCC for the year 2050 predicts noticeable increases in temperature. In severe summer climates, such as the Mediterranean area, this would have very negative effects on thermal comfort in the existing housing stock, given the current high percentage of dwellings which are obsolete in energy terms and house a population at serious risk of energy poverty. The main aim of this paper is to generate a predictive model in order to assess the impact of this future climate scenario on thermal comfort conditions in an entire building category. To do so, calibrated models representing linear-type social multi-family buildings, dating from the post-war period and located in southern Spain, will be simulated extensively using transient energy analyses performed by EnergyPlus. In addition, a sensitivity analysis will be performed to identify the most influential parameters on thermal discomfort. The main results predict a generalized deterioration in indoor thermal comfort conditions due to global warming, increasing the average percentage of discomfort hours during the summer by more than 35%. This characterization of the future thermal behaviour of the residential stock in southern Spain could be a trustworthy tool for decision-making in energy retrofitting projects which are so badly needed. To do so, further work is required on some limitations of this model so that different user profiles and typologies can be represented in detail and an economic assessment can be included.
Collapse
|
3
|
Assessment of Indoor Environmental Quality for Retrofitting Classrooms with An Egg-Crate Shading Device in A Hot Climate. SUSTAINABILITY 2019. [DOI: 10.3390/su11041078] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
In the Mediterranean climate, a large number of educational buildings suffer from discomfort due mostly to energy-deficient thermal envelopes and a lack of cooling systems. Impending climate change is expected to worsen overheating in classrooms, especially during heatwave periods. Therefore, the protection of window openings to reduce incident solar radiation while maintaining adequate indoor environmental quality must be considered a necessary key focus. The main objective of this research is to assess the influence of an egg-crate shading device on the indoor environmental quality of a classroom in Southern Spain. To do so, two classrooms—with and without this shading device—were simultaneously monitored over a whole year. The implementation of an egg-crate shading device allowed for a significant reduction of the incident solar radiation, both in summer and mid-season (around 45–50%), which objectively slightly conditioned indoor operative temperatures. Given the noticeable influence of the user patterns observed, indoor illuminance was also improved, as the rolling shutters tended to be opened at higher aperture levels.
Collapse
|
4
|
Daylighting Performance of Solar Control Films for Hospital Buildings in a Mediterranean Climate. ENERGIES 2019. [DOI: 10.3390/en12030489] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
One of the main retrofitting strategies in warm climates is the reduction of the effects of solar radiation. Cooling loads, and in turn, cooling consumption, can be reduced through the implementation of reflective materials such as solar control films. However, these devices may also negatively affect daylight illuminance conditions and the electric consumption of artificial lighting systems. In a hospital building, it is crucial to meet daylighting requirements as well as indoor illuminance levels and visibility from the inside, as these have a significant impact on health outcomes. The aim of this paper is to evaluate the influence on natural illuminance conditions of a solar control film installed on the windows of a public hospital building in a Mediterranean climate. To this end, a hospital room, with and without solar film, was monitored for a whole year. A descriptive statistical analysis was conducted on the use of artificial lighting, illuminance levels and rolling shutter aperture levels, as well as an analysis of natural illuminance and electric consumption of the artificial lighting system. The addition of a solar control film to the external surface of the window, in combination with the user-controlled rolling shutter aperture levels, has reduced the electric consumption of the artificial lighting system by 12.2%. Likewise, the solar control film has increased the percentage of annual hours with natural illuminance levels by 100–300 lux.
Collapse
|