1
|
Fabrication of Rigid Isocyanate-Based Polyimide Foam Achieved Excellent Use Safety via Synergy between Expandable Graphite and Phosphorus-Containing Polyol. Polymers (Basel) 2023; 15:polym15061381. [PMID: 36987162 PMCID: PMC10052713 DOI: 10.3390/polym15061381] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 01/04/2023] [Accepted: 01/05/2023] [Indexed: 03/12/2023] Open
Abstract
For the advantages of low cost, excellent thermal insulation, and sound absorption properties, the rigid isocyanate-based polyimide foam (RPIF) presents great application prospects as a building insulation material. However, its inflammability and the accompanying toxic fumes create huge safety hazard. In this paper, reactive phosphate-containing polyol (PPCP) is synthesized and employed with expandable graphite (EG) to obtain RPIF with excellent use safety. EG can be considered as an ideal partner for PPCP to weaken the drawbacks in toxic fume release. Limiting oxygen index (LOI), cone calorimeter test (CCT), and toxic gas results show that the combination of PPCP and EG can synergistically enhance flame retardancy and the use safety of RPIF owing to the unique structure of a dense char layer possessing a flame barrier and toxic gas adsorption effects. When EG and PPCP are simultaneously applied to the RPIF system, the higher EG dosage will bring higher positive synergistic effects in the use safety of RPIF. The most preferred ratio of EG and PPCP is 2:1 (RPIF-10-5) in this study; RPIF-10-5 shows the highest LOI, low CCT results and specific optical density of smoke, and low HCN concentration. This design and the findings are of great significance to improving the application of RPIF.
Collapse
|
2
|
New Calculation Technique for Assessment of Smoke Layer Interface in Large Buildings in Connection with the Design of Buildings in the Czech Republic. SUSTAINABILITY 2022. [DOI: 10.3390/su14116445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
The sustainability of the indoor environment of buildings is also related to the conditions that arise in the case of fires. Fires in buildings are characterized by the formation of combustion products, which can significantly endanger the life and health of people. One of the major sources of danger is smoke. If there is no smoke exhaust into the outside environment during the development of the fire, the building is gradually filled with smoke. The important characteristic of the smoke layer is the level of the smoke layer, which changes over time. Several methods have been derived for determining the descent of the smoke layer in an enclosed area of space, which mainly differ in terms of the application area and limits of use. The methods used in the Czech Republic for the assessment of smoke layer descent in the case of fires do not have a clear rationale and in many cases lead to completely misleading results. For this reason, in connection with the standards for the assessment of the buildings in the Czech Republic, a new calculation technique (CSN) has been derived, which has been compared with the selected simple calculation techniques in large buildings. The deviations between the results have been evaluated by the percentage bias method (PBIAS), while the largest deviation, compared to the ISO standard technique, did not exceed 20%. The CSN calculation technique shows a favourable compliance with the technique presented by the ISO standard, where the deviation did not exceed 1.6%. In response to the proposed standards in the Czech Republic, the CSN calculation technique enables the assessment of safe evacuation in relation to the smoke layer interface and can be a considered perspective.
Collapse
|