1
|
Impact of Separator Thickness on Temperature Distribution in Single Cell of Polymer Electrolyte Fuel Cell Operated at Higher Temperature of 90 °C and 100 °C. ENERGIES 2022. [DOI: 10.3390/en15124203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The New Energy and Industry Technology Development Organization (NEDO) road map (Japan, 2017) has proposed that a polymer electrolyte fuel cell (PEFC) system, which operates at a temperature of 90 °C and 100 °C, be applied for stationary and mobility usage, respectively. This study suggests using a thin polymer electrolyte membrane (PEM) and a thin gas diffusion layer (GDL), at the same time, to achieve better power-generation performance, at a higher temperature than usual. The focus of this paper is to clarify the effect of separator thickness on the distribution of temperature at the reaction surface (Treact), with the relative humidity (RH) of the supply gasses and initial operation temperature (Tini), quantitatively. In this study, separator thickness is investigated in a system using a thin PEM and a thin GDL. Moreover, this study investigates the difference between the maximum temperature and the minimum temperature obtained from the distribution of Treact as well as the relation between the standard deviation of Treact − Tini and total voltage, to clarify the effect of separator thickness. The impact of the flow rates of the supply gases on the distribution of Treact is not large, among the investigated conditions. It is noticed that the temperature distribution is wider when a separator thickness of 2.0 mm is selected. On the other hand, it is observed that the temperature increases along with the gas flow through the gas channel, by approximately 2 °C, when using a separator thickness between 1.5 mm and 1.0 mm. The impact of the RH on the distributions of Treact − Tini is larger at Tini = 100 °C, when a separator thickness of 1.0 mm is selected. It is revealed that the wider temperature distribution provides a reduction in power-generation performance. This study proposes that the thin separators, i.e., with a thickness of 1.5 mm and 1.0 mm, are not suitable for higher temperature operation than usual.
Collapse
|
2
|
Thermoelectric Generator as the Waste Heat Recovery Unit of Proton Exchange Membrane Fuel Cell: A Numerical Study. ENERGIES 2022. [DOI: 10.3390/en15093018] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The proton exchange membrane fuel cell (PEMFC) is a prominent environmentally friendly alternative candidate to internal combustion engines in automotive applications. The recovery of the waste heat of light-duty diesel engines has been investigated recently, which is similarly relevant for PEMFCs. Thermoelectric generators (TEG) applied on the stack’s walls have been already proposed and tested as a cooling method for small scale applications of the PEMFC. For the medium scale usages of the PEMFC stack, TEG technology may be further used to recover heat lost through the cooling water required for stack thermal management, which was the focus of the present study. Using an agglomerate model for the PEMFC and a computational fluid dynamic (CFD) thermal model for the TEG heat exchanger unit, the operation and performance of the PEMFC stack and heat recovery unit were simulated, respectively. After validation, results indicated that the transferred heat from the PEMFC to the cooling channel increased the temperature of the coolant from room temperature to 330.5 K at the current density of 0.8 A/cm2. CFD analysis revealed that 37.7 W of the heated wasted by the PEMFC stack could be recovered by the currently available TEG material and geometry.
Collapse
|