1
|
Shao Y, Li X, Qi X, Li J, Zhao S, Sun P, Wang H, Cheng Y, Zhang Z, Chen L, Zhang X, Zhu M. A graphene oxide-assisted protein immobilization paper-tip immunosensor with smartphone and naked eye readout for the detection of okadaic acid. Anal Chim Acta 2024; 1314:342781. [PMID: 38876519 DOI: 10.1016/j.aca.2024.342781] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2024] [Revised: 05/21/2024] [Accepted: 05/23/2024] [Indexed: 06/16/2024]
Abstract
BACKGROUND Okadaic acid (OA), as a diarrhetic shellfish poisoning, can increase the risk of acute carcinogenic or teratogenic effects for the ingestion of OA contaminated shellfish. At present, much effort has been made to graft immunoassay onto a paper substrate to make paper-based sensors for rapid and simple detection of shellfish toxin. However, the complicated washing steps and low protein fixation efficiency on the paper substrate need to be further addressed. RESULTS A novel paper-tip immunosensor for detecting OA was developed combined with smartphone and naked eye readout. The trapezoid paper tip was consisted of quantitative and qualitative detection zones. To improve the OA antigen immobilization efficiency on the paper substrate, graphene oxide (GO)-assisted protein immobilization method was introduced. Meanwhile, Au nanoparticles composite probe combined with the lateral flow washing was developed to simplify the washing step. The OA antigen-immobilized zone, as the detection zone Ⅰ, was used for quantitative assay by smartphone imaging. The paper-tip front, as the detection zone Ⅱ, which could qualitatively differentiate OA pollution level within 45 min using the naked eye. The competitive immunoassay on the paper tip exhibited a wide linear range for detecting OA (0.02-50 ng∙mL-1) with low detection limit of 0.02 ng∙mL-1. The recovery of OA in spiked shellfish samples was in the range of 90.3 %-113.%. SIGNIFICANCE These results demonstrated that the proposed paper-tip immunosensor could provide a simple, low-cost and high-sensitivity test for OA detection without the need for additional large-scale equipment or expertise. We anticipate that this paper-tip immunosensor will be a flexible and versatile tool for on-site detecting the pollution of marine products.
Collapse
Affiliation(s)
- Yifan Shao
- Institute of Eco-Environmental Forensics, School of Environmental Science and Engineering, Shandong University (Qingdao), Qingdao, Shandong, 266237, China
| | - Xiaotong Li
- Institute of Eco-Environmental Forensics, School of Environmental Science and Engineering, Shandong University (Qingdao), Qingdao, Shandong, 266237, China
| | - Xiaoxiao Qi
- Institute of Eco-Environmental Forensics, School of Environmental Science and Engineering, Shandong University (Qingdao), Qingdao, Shandong, 266237, China
| | - Juan Li
- Key Laboratory of Ecological Prewarning, Protection and Restoration of Bohai Sea, Ministry of Natural Resources, China
| | - Sheng Zhao
- Key Laboratory of Ecological Prewarning, Protection and Restoration of Bohai Sea, Ministry of Natural Resources, China
| | - Peiyan Sun
- Key Laboratory of Ecological Prewarning, Protection and Restoration of Bohai Sea, Ministry of Natural Resources, China
| | | | - Yongqiang Cheng
- Institute of Eco-Environmental Forensics, School of Environmental Science and Engineering, Shandong University (Qingdao), Qingdao, Shandong, 266237, China.
| | - Ziwei Zhang
- Institute of Eco-Environmental Forensics, School of Environmental Science and Engineering, Shandong University (Qingdao), Qingdao, Shandong, 266237, China
| | - Longyu Chen
- Institute of Eco-Environmental Forensics, School of Environmental Science and Engineering, Shandong University (Qingdao), Qingdao, Shandong, 266237, China
| | - Xi Zhang
- Institute of Eco-Environmental Forensics, School of Environmental Science and Engineering, Shandong University (Qingdao), Qingdao, Shandong, 266237, China
| | - Meijia Zhu
- Institute of Eco-Environmental Forensics, School of Environmental Science and Engineering, Shandong University (Qingdao), Qingdao, Shandong, 266237, China
| |
Collapse
|
2
|
Wang Y, Javeed A, Jian C, Zeng Q, Han B. Precautions for seafood consumers: An updated review of toxicity, bioaccumulation, and rapid detection methods of marine biotoxins. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2024; 274:116201. [PMID: 38489901 DOI: 10.1016/j.ecoenv.2024.116201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2023] [Revised: 03/03/2024] [Accepted: 03/08/2024] [Indexed: 03/17/2024]
Abstract
Seafood products are globally consumed, and there is an increasing demand for the quality and safety of these products among consumers. Some seafoods are easily contaminated by marine biotoxins in natural environments or cultured farming processes. When humans ingest different toxins accumulated in seafood, they may exhibit different poisoning symptoms. According to the investigations, marine toxins produced by harmful algal blooms and various other marine organisms mainly accumulate in the body organs such as liver and digestive tract of seafood animals. Several regions around the world have reported incidents of seafood poisoning by biotoxins, posing a threat to human health. Thus, most countries have legislated to specify the permissible levels of these biotoxins in seafood. Therefore, it is necessary for seafood producers and suppliers to conduct necessary testing of toxins in seafood before and after harvesting to prohibit excessive toxins containing seafood from entering the market, which therefore can reduce the occurrence of seafood poisoning incidents. In recent years, some technologies which can quickly, conveniently, and sensitively detect biological toxins in seafood, have been developed and validated, these technologies have the potential to help seafood producers, suppliers and regulatory authorities. This article reviews the seafood toxins sources and types, mechanism of action and bioaccumulation of marine toxins, as well as legislation and rapid detection technologies for biotoxins in seafood for official and fishermen supervision.
Collapse
Affiliation(s)
- Yifan Wang
- Zhejiang Provincial Key Laboratory of Silkworm Bioreactor and Biomedicine, Laboratory of Antiallergic Functional Molecules, College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, China
| | - Ansar Javeed
- Zhejiang Provincial Key Laboratory of Silkworm Bioreactor and Biomedicine, Laboratory of Antiallergic Functional Molecules, College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, China
| | - Cuiqin Jian
- Zhejiang Provincial Key Laboratory of Silkworm Bioreactor and Biomedicine, Laboratory of Antiallergic Functional Molecules, College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, China
| | - Qiuyu Zeng
- Zhejiang Provincial Key Laboratory of Silkworm Bioreactor and Biomedicine, Laboratory of Antiallergic Functional Molecules, College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, China
| | - Bingnan Han
- Zhejiang Provincial Key Laboratory of Silkworm Bioreactor and Biomedicine, Laboratory of Antiallergic Functional Molecules, College of Life Sciences and Medicine, Zhejiang Sci-Tech University, Hangzhou, Zhejiang 310018, China.
| |
Collapse
|
3
|
Wang N, Zhang J, Xiao B, Chen A. Microfluidic-assisted integrated nucleic acid test strips for POCT. Talanta 2024; 267:125150. [PMID: 37672986 DOI: 10.1016/j.talanta.2023.125150] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 08/16/2023] [Accepted: 09/01/2023] [Indexed: 09/08/2023]
Abstract
Numerous diseases have posed significant threats to public health, notably the global pandemic of COVID-19, resulting in widespread devastation due to its high infectivity and severity. The nucleic acid lateral flow assay (NALFA) addresses challenges of complexity, cost, and time associated with traditional assays, offering a reliable platform for rapid and precise nucleic acid target detection. NALFA is gaining prominence as a point-of-care testing (POCT) technique, thanks to its user-friendly operation and rapid results. Nevertheless, conventional NALFA relies on specialized technicians and involves labor-intensive steps like DNA extraction and PCR processes, impeding its efficiency. To overcome these limitations, integrating NALFA with microfluidic technology, widely employed in rapid field detection, holds promise. This review comprehensively outlines prevailing strategies for integrating NALFA, encompassing both research initiatives and commercial applications. Addressing the bottleneck of nucleic acid amplification as a rate-limiting step, the review delves into progress in amplification-free NALFA and highlights prevalent signal amplification techniques. Ultimately, the review outlines the future prospect of integrated NALFA development, capturing the technology's evolution and providing valuable insights for academic and commercial endeavors.
Collapse
Affiliation(s)
- Nan Wang
- Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Juan Zhang
- Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Bin Xiao
- Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing, 100081, China
| | - Ailiang Chen
- Institute of Quality Standard & Testing Technology for Agro-Products, Key Laboratory of Agro-product Quality and Safety, Chinese Academy of Agricultural Sciences, Beijing, 100081, China.
| |
Collapse
|
4
|
Zhou Y, Chen Q, Huang G, Huang S, Lin C, Lin X, Xie Z. Oriented-aptamer encoded magnetic nanosensor with laser-induced fluorescence for ultrasensitive test of okadaic acid. Talanta 2024; 266:124984. [PMID: 37549567 DOI: 10.1016/j.talanta.2023.124984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 07/19/2023] [Accepted: 07/23/2023] [Indexed: 08/09/2023]
Abstract
Okadaic acid (OA) biotoxin acts a well-established inhibitor of protein phosphatase even a tumor promoter of human being, arouse great attention in safety monitoring. However, the powerful and convenient nanosensing technologies for addressing the demands such as rapidity, high sensitivity, and stability in the in-field test of OA shellfish toxin is still scarce. Herein, a high-performance magnetic biometric nanosensor (MBNS) integrating oriented aptamers and ultrasensitive laser-induced fluorescence (LIF) was firstly proposed for the in-field detection of trace OA in seafoods. High-density aptamers hybridized with FAM-labeled cDNA were tethered to the surface of AuNPs on magnetic MIL-101@Fe3O4, and then finely regulated by mercaptohexyl alcohol (MCH) to be orderly assembled, as was successfully utilized to engineer an active biological nanosensor for highly specific recognition of OA. Aptamers anchored on magnetic Fe3O4@MOF@AuNPs activate a biometric microreactor of OA, in which the superior LIF properties, conformation regulation of aptamer, and the specific recognition using aptamer genes were adopted. The magnetic nanosensor with an excellent specificity and super sensitivity for OA analysis was achieved within 20 min. Moreover, the content of captured OA could facilely be recorded by measuring the fluorescence intensity, and the limit of detection (LOD) and limit of quantitation of OA (LOQ) reached 0.015 and 0.050 ng/mL respectively, which was far better than most aptamer-based biometric sensing methods. The feasibility for accurate test of trace OA toxin in the fortified shellfish samples was validated with the recovery yields of 88.2-107.5% and RSD of 0.5-7.6%, respectively. The result demonstrated that the oriented-aptamer encoded MNS had significant practical values in rapid and ultrasensitive detection of OA biotoxin and the related safety applications.
Collapse
Affiliation(s)
- Yuwei Zhou
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, China
| | - Qingai Chen
- College of Tourism and Leisure Management, Fujian Business University, Fuzhou, Fujian, 350012, China
| | - Guobin Huang
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, China
| | - Shukun Huang
- Zhicheng College, Fuzhou University, 350102, China.
| | - Chenchen Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, China
| | - Xucong Lin
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, China; Engineering Technology Research Center on Reagent and Instrument for Rapid Detection of Product Quality and Food Safety in Fujian Province, Fuzhou University, Fuzhou, 350108, China.
| | - Zenghong Xie
- Institute of Food Safety and Environment Monitoring, Fuzhou University, Fuzhou, 350108, China
| |
Collapse
|
5
|
Panferov VG, Zherdev AV, Dzantiev BB. Post-Assay Chemical Enhancement for Highly Sensitive Lateral Flow Immunoassays: A Critical Review. BIOSENSORS 2023; 13:866. [PMID: 37754100 PMCID: PMC10526817 DOI: 10.3390/bios13090866] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 08/15/2023] [Accepted: 08/23/2023] [Indexed: 09/28/2023]
Abstract
Lateral flow immunoassay (LFIA) has found a broad application for testing in point-of-care (POC) settings. LFIA is performed using test strips-fully integrated multimembrane assemblies containing all reagents for assay performance. Migration of liquid sample along the test strip initiates the formation of labeled immunocomplexes, which are detected visually or instrumentally. The tradeoff of LFIA's rapidity and user-friendliness is its relatively low sensitivity (high limit of detection), which restricts its applicability for detecting low-abundant targets. An increase in LFIA's sensitivity has attracted many efforts and is often considered one of the primary directions in developing immunochemical POC assays. Post-assay enhancements based on chemical reactions facilitate high sensitivity. In this critical review, we explain the performance of post-assay chemical enhancements, discuss their advantages, limitations, compared limit of detection (LOD) improvements, and required time for the enhancement procedures. We raise concerns about the performance of enhanced LFIA and discuss the bottlenecks in the existing experiments. Finally, we suggest the experimental workflow for step-by-step development and validation of enhanced LFIA. This review summarizes the state-of-art of LFIA with chemical enhancement, offers ways to overcome existing limitations, and discusses future outlooks for highly sensitive testing in POC conditions.
Collapse
Affiliation(s)
- Vasily G. Panferov
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (V.G.P.); (A.V.Z.)
- Department of Chemistry, York University, Toronto, ON M3J 1P3, Canada
| | - Anatoly V. Zherdev
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (V.G.P.); (A.V.Z.)
| | - Boris B. Dzantiev
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, 119071 Moscow, Russia; (V.G.P.); (A.V.Z.)
| |
Collapse
|
6
|
Li P, Jin M. Application of Immunoassay Technology in Food Inspection. Foods 2023; 12:2923. [PMID: 37569192 PMCID: PMC10417638 DOI: 10.3390/foods12152923] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 07/29/2023] [Indexed: 08/13/2023] Open
Abstract
Food safety is as important as ever, and the safeguards implemented to inspect and reduce pesticides, veterinary drugs, toxins, pathogens, illegal additives, and other deleterious contaminants in our food supply has helped improve human health and increase the length and quality of our lives [...].
Collapse
Affiliation(s)
| | - Maojun Jin
- Institute of Quality Standard and Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing 100081, China;
| |
Collapse
|
7
|
Shan W, Chen K, Sun J, Liu R, Xu W, Shao B. Mismatched duplexed aptamer-isothermal amplification-based nucleic acid-nanoflower for fluorescent detection of okadaic acid. Food Chem 2023; 424:136374. [PMID: 37207608 DOI: 10.1016/j.foodchem.2023.136374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 05/07/2023] [Accepted: 05/11/2023] [Indexed: 05/21/2023]
Abstract
We developed a highly sensitive fluorescent assay to detect okadaic acid (OA), a prevalent aquatic toxin posing serious health risks. Our approach uses a mismatched duplexed aptamer (DA) immobilized on streptavidin-conjugated magnetic beads (SMBs) to create a DA@SMB complex. In the presence of OA, the cDNA unwinds, hybridizes with a G-rich segment pre-encoding circular template (CT), and undergoes rolling circle amplification (RCA) to produce G-quadruplexes, which are detected using the fluorescent dye thioflavine T (ThT). The method has a LOD of 3.1 × 10-3 ng/mL, a linear range of 0.1 ∼ 1.0 × 103 ng/mL, and was successfully applied to shellfish samples with spiked recoveries of 85.9% ∼ 102.2% and RSD less than 13%. Furthermore, instrumental analysis confirmed the accuracy and reliability of this rapid detection method. Overall, this work represents a significant advancement in the field of rapid aquatic toxin detection and has important implications for public health and safety.
Collapse
Affiliation(s)
- Wenchong Shan
- Department of Veterinary Pharmacology and Toxicology, College of Veterinary Medicine, China Agricultural University, Beijing 100193, PR China
| | - Keren Chen
- Department of Nutrition and Health (Institute of Nutrition and Health), China Agricultural University, Beijing 100083, PR China
| | - Jiefang Sun
- Beijing Center for Disease Prevention and Control, Beijing 100013, PR China
| | - Runqing Liu
- Beijing Center for Disease Prevention and Control, Beijing 100013, PR China
| | - Wentao Xu
- Department of Nutrition and Health (Institute of Nutrition and Health), China Agricultural University, Beijing 100083, PR China.
| | - Bing Shao
- Department of Veterinary Pharmacology and Toxicology, College of Veterinary Medicine, China Agricultural University, Beijing 100193, PR China; Beijing Center for Disease Prevention and Control, Beijing 100013, PR China; Food Laboratory of Zhongyuan, Luohe 462300, PR China.
| |
Collapse
|
8
|
Hendrickson OD, Mukhametova LI, Zvereva EA, Zherdev AV, Eremin SA. A Sensitive Fluorescence Polarization Immunoassay for the Rapid Detection of Okadaic Acid in Environmental Waters. BIOSENSORS 2023; 13:bios13040477. [PMID: 37185552 PMCID: PMC10136290 DOI: 10.3390/bios13040477] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Revised: 04/07/2023] [Accepted: 04/14/2023] [Indexed: 05/17/2023]
Abstract
In this study, a homogeneous fluorescence polarization immunoassay (FPIA) for the detection of hazardous aquatic toxin okadaic acid (OA) contaminating environmental waters was for the first time developed. A conjugate of the analyte with a fluorophore based on a fluorescein derivative (tracer) was synthesized, and its interaction with specific anti-OA monoclonal antibodies (MAbs) was tested. A MAbs-tracer pair demonstrated highly affine immune binding (KD = 0.8 nM). Under optimal conditions, the limit of OA detection in the FPIA was 0.08 ng/mL (0.1 nM), and the working range of detectable concentrations was 0.4-72.5 ng/mL (0.5-90 nM). The developed FPIA was approbated for the determination of OA in real matrices: river water and seawater samples. No matrix effect of water was observed; therefore, no sample preparation was required before analysis. Due to this factor, the entire analytical procedure took less than 10 min. Using a compact portable fluorescence polarization analyzer enables the on-site testing of water samples. The developed analysis is very fast, easy to operate, and sensitive and can be extended to the determination of other aquatic toxins or low-molecular-weight water or food contaminants.
Collapse
Affiliation(s)
- Olga D Hendrickson
- A. N. Bach Institute of Biochemistry, Research Center of Biotechnology, Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia
| | - Liliya I Mukhametova
- Department of Chemical Enzymology, Faculty of Chemistry, M. V. Lomonosov Moscow State University, Leninskie Gory 1, 119991 Moscow, Russia
| | - Elena A Zvereva
- A. N. Bach Institute of Biochemistry, Research Center of Biotechnology, Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia
| | - Anatoly V Zherdev
- A. N. Bach Institute of Biochemistry, Research Center of Biotechnology, Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia
| | - Sergei A Eremin
- A. N. Bach Institute of Biochemistry, Research Center of Biotechnology, Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia
- Department of Chemical Enzymology, Faculty of Chemistry, M. V. Lomonosov Moscow State University, Leninskie Gory 1, 119991 Moscow, Russia
| |
Collapse
|
9
|
Panferov VG, Ivanov NA, Mazzulli T, Brinc D, Kulasingam V, Krylov SN. Electrophoresis-Assisted Multilayer Assembly of Nanoparticles for Sensitive Lateral Flow Immunoassay. Angew Chem Int Ed Engl 2023; 62:e202215548. [PMID: 36357330 DOI: 10.1002/anie.202215548] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Indexed: 11/12/2022]
Abstract
Lateral flow immunoassay (LFIA) is a rapid, simple, and inexpensive point-of-need method. A major limitation of LFIA is a high limit of detection (LOD), which impacts its diagnostic sensitivity. To overcome this limitation, we introduce a signal-enhancement procedure that is performed after completing LFIA and involves controllably moving biotin- and streptavidin-functionalized gold nanoparticles by electrophoresis. The nanoparticles link to immunocomplexes forming multilayer aggregates on the test strip, thus, enhancing the signal. Here, we demonstrate lowering the LOD of hepatitis B surface antigen from approximately 8 to 0.12 ng mL-1 , making it clinically acceptable. Testing 118 clinical samples for hepatitis B showed that signal enhancement increased the diagnostic sensitivity of LFIA from 73 % to 98 % while not affecting its 95 % specificity. Electrophoresis-driven enhancement of LFIA is universal (antigen-independent), takes two minutes, and can be performed by an untrained person.
Collapse
Affiliation(s)
- Vasily G Panferov
- Department of Chemistry, York University, 4700 Keele Street, Toronto, Ontario M3J 1P3, Canada.,Centre for Research on Biomolecular Interactions, York University, 4700 Keele Street, Toronto, Ontario M3J 1P3, Canada.,A.N. Bach Institute of Biochemistry, Federal Research Centre "Fundamentals of Biotechnology" Russian Academy of Sciences, 33 Leninsky Prospect, Moscow, 119071, Russia
| | - Nikita A Ivanov
- Department of Chemistry, York University, 4700 Keele Street, Toronto, Ontario M3J 1P3, Canada.,Centre for Research on Biomolecular Interactions, York University, 4700 Keele Street, Toronto, Ontario M3J 1P3, Canada
| | - Tony Mazzulli
- Sinai Health, 600 University Avenue, Toronto, Ontario M5G 1X5, Canada
| | - Davor Brinc
- Toronto General Hospital: University Health Network, 200 Elizabeth St., Toronto, Ontario M5G 2C4, Canada
| | - Vathany Kulasingam
- Toronto General Hospital: University Health Network, 200 Elizabeth St., Toronto, Ontario M5G 2C4, Canada
| | - Sergey N Krylov
- Department of Chemistry, York University, 4700 Keele Street, Toronto, Ontario M3J 1P3, Canada.,Centre for Research on Biomolecular Interactions, York University, 4700 Keele Street, Toronto, Ontario M3J 1P3, Canada
| |
Collapse
|
10
|
Hendrickson OD, Zvereva EA, Panferov VG, Solopova ON, Zherdev AV, Sveshnikov PG, Dzantiev BB. Application of Au@Pt Nanozyme as Enhancing Label for the Sensitive Lateral Flow Immunoassay of Okadaic Acid. BIOSENSORS 2022; 12:bios12121137. [PMID: 36551104 PMCID: PMC9775009 DOI: 10.3390/bios12121137] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 11/29/2022] [Accepted: 12/05/2022] [Indexed: 05/28/2023]
Abstract
In this study, a lateral flow immunoassay (LFIA) was developed to detect okadaic acid (OA) belonging to the diarrheic shellfish poisoning group of aquatic toxins. Newly obtained anti-OA monoclonal antibodies and bimetallic core@shell Au@Pt nanoparticles were used in the indirect format of the LFIA. Peroxidase-mimicking nanozyme properties of Au@Pt enabled using them to enhance band coloration on the test strips and, consequently, for increasing the LFIA sensitivity. The instrumental limit of detection (LOD), the working range of detectable concentrations, and the visual cutoff of the assay were 0.5, 0.8-6.8, and 10 ng/mL, respectively. The assay duration was 20 min. The rapid and simple sample preparation procedure was applied for seawater, river water, and fish samples. The total duration of the sample pretreatment and LFIA was 25/40 min for water/fish samples, ensuring testing rapidity. The developed test system provides sensitive control of raw materials and food products and can be used to detect OA at all stages of the food industry «from sea to fork» chains.
Collapse
Affiliation(s)
- Olga D. Hendrickson
- Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia
| | - Elena A. Zvereva
- Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia
| | - Vasily G. Panferov
- Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia
| | - Olga N. Solopova
- Blokhin National Medical Research Center of Oncology, Ministry of Health of the Russian Federation, Kashirskoye Shosse 24, 115478 Moscow, Russia
| | - Anatoly V. Zherdev
- Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia
| | - Peter G. Sveshnikov
- Russian Research Center for Molecular Diagnostics and Therapy, Sympheropolsky Blvrd., 8, 117638 Moscow, Russia
| | - Boris B. Dzantiev
- Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia
| |
Collapse
|
11
|
Zvereva EA, Hendrickson OD, Solopova ON, Zherdev AV, Sveshnikov PG, Dzantiev BB. Triple immunochromatographic test system for detection of priority aquatic toxins in water and fish. Anal Bioanal Chem 2022; 414:7553-7563. [PMID: 36097195 DOI: 10.1007/s00216-022-04298-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 07/27/2022] [Accepted: 08/18/2022] [Indexed: 11/25/2022]
Abstract
Aquatic toxins are a group of toxic compounds produced by several types of freshwater and marine algae and cyanobacteria and transported through the food chains of water bodies. Potential contamination of aquaculture products (raw and processed fish and seafood) with aquatic toxins requires the use of efficient screening methods for their control. In this study, a multiplex immunochromatographic test system for the simultaneous detection of three aquatic toxins-phycotoxins domoic acid (DA) and okadaic acid (OA), and cyanotoxin microcystin-LR (MC-LR)-is for the first time developed. For this, a competitive indirect immunochromatographic analysis (ICA) based on gold-labeled secondary antibodies was carried out. The LODs/cutoffs/working ranges of the ICA were 0.05/0.3/0.07-0.29, 1.3/100/3.2-58.2, and 0.1/2.0/0.2-1.1 ng/mL for MC-LR, DA, and OA, respectively. The assay duration was 18 min. The developed test system was used to analyze water samples from natural sources (salt and fresh water) and fish samples. For sample preparation of water, simple dilution with a buffer was proposed; for fish samples, methanol-water extraction was utilized. It was demonstrated that the triple LFIA specifically detected target aquatic toxins with recoveries of 85.0-121.5%. The developed multiplex LFIA can be considered a promising analytical solution for the rapid, easy, and sensitive control of water and food safety.
Collapse
Affiliation(s)
- Elena A Zvereva
- Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky prospect 33, 119071, Moscow, Russia
| | - Olga D Hendrickson
- Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky prospect 33, 119071, Moscow, Russia
| | - Olga N Solopova
- Blokhin National Medical Research Center of Oncology, Ministry of Health of the Russian Federation, Kashirskoye shosse 24, 115478, Moscow, Russia
| | - Anatoly V Zherdev
- Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky prospect 33, 119071, Moscow, Russia
| | - Peter G Sveshnikov
- Russian Research Center for Molecular Diagnostics and Therapy, Sympheropolsky Blvrd., 8, 117638, Moscow, Russia
| | - Boris B Dzantiev
- Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky prospect 33, 119071, Moscow, Russia.
| |
Collapse
|
12
|
Xu H, Lan H, Pan D, Xu J, Wang X. Visual Detection of Chicken Adulteration Based on a Lateral Flow Strip-PCR Strategy. Foods 2022; 11:foods11152351. [PMID: 35954117 PMCID: PMC9368418 DOI: 10.3390/foods11152351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 08/02/2022] [Indexed: 11/23/2022] Open
Abstract
The aim of this study was to develop an accurate, easy-to-use, and cost-effective method for the detection of chicken adulteration based on polymerase chain reaction (PCR) and lateral flow strip (LFS). We compared six DNA extraction methods, namely the cetyltrimethylammonium bromide (CTAB) method, salt method, urea method, SDS method, guanidine isothiocyanate method, and commercial kit method. The chicken cytb gene was used as a target to design specific primers. The specificity and sensitivity of the PCR-LFS system were tested using a self-assembled lateral flow measurement sensor. The results showed that the DNA concentration obtained by salt methods is up to 533 ± 84 ng µL−1, is a suitable replacement for commercial kits. The PCR-LFS method exhibits high specificity at an annealing temperature of 62 °C and does not cross-react with other animal sources. This strategy is also highly sensitive, being able to detect 0.1% of chicken in artificial adulterated meat. The results of the test strips can be observed with the naked eye within 5 min, and this result is consistent with the electrophoresis result, demonstrating its high accuracy. Moreover, the detection system has already been successfully used to detect chicken in commercial samples. Hence, this PCR-LFS strategy provides a potential tool to verify the authenticity of chicken.
Collapse
Affiliation(s)
- Haoyi Xu
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-Products, Ningbo University, Ningbo 315211, China
| | - Hangzhen Lan
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-Products, Ningbo University, Ningbo 315211, China
- Correspondence: (H.L.); (X.W.)
| | - Daodong Pan
- Key Laboratory of Animal Protein Deep Processing Technology of Zhejiang Province and College of Food and Pharmaceutical Sciences, Ningbo University, Ningbo 315800, China
| | - Junfeng Xu
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-Products, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, China
- Key Laboratory of Traceability for Agricultural Genetically Modified Organisms, Ministry of Agriculture and Rural Affairs, Hangzhou 310021, China
| | - Xiaofu Wang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-Products, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, China
- Correspondence: (H.L.); (X.W.)
| |
Collapse
|