Shusterman A, Nashef R, Tecco S, Mangano C, Lerner H, Mangano FG. Accuracy of implant placement using a mixed reality-based dynamic navigation system versus static computer-assisted and freehand surgery: An in Vitro study. J Dent 2024; 146:105052. [PMID: 38734298 DOI: 10.1016/j.jdent.2024.105052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 05/01/2024] [Accepted: 05/02/2024] [Indexed: 05/13/2024] Open
Abstract
PURPOSE This in vitro study aimed to compare the accuracy of dental implant placement in partially edentulous maxillary models using a mixed reality-based dynamic navigation (MR-DN) system to conventional static computer-assisted implant surgery (s-CAIS) and a freehand (FH) method. METHODS Forty-five partially edentulous models (with teeth missing in positions #15, #16 and #25) were assigned to three groups (15 per group). The same experienced operator performed the model surgeries using an MR-DN system (group 1), s-CAIS (group 2) and FH (group 3). In total, 135 dental implants were placed (45 per group). The primary outcomes were the linear coronal deviation (entry error; En), apical deviation (apex error; Ap), XY and Z deviations, and angular deviation (An) between the planned and actual (post-surgery) position of the implants in the models. These deviations were computed as the distances between the stereolithographic (STL) files for the planned implants and placed implants captured with an intraoral scanner. RESULTS Across the three implant sites, the MR-DN system was significantly more accurate than the FH method (in XY, Z, En, Ap and An) and s-CAIS (in Z, Ap and An), respectively. However, S-CAIS was more accurate than MR-DN in XY, and no difference was found between MR-DN and s-CAIS in En. CONCLUSIONS Within the limits of this study (in vitro design, only partially edentulous models), implant placement accuracy with MR-DN was superior to that of FH and similar to that of s-CAIS. STATEMENT OF CLINICAL RELEVANCE In vitro, MR-DN showed greater accuracy in implant positioning than FH, and similar accuracy to s-CAIS: it could, therefore, represent a new option for the surgeon. However, clinical studies are needed to determine the feasibility of MR-DN.
Collapse
Affiliation(s)
| | - Rizan Nashef
- Oral and Maxillofacial Surgery Unit, Shaare Zedek Medical center, Jerusalem Israel.
| | - Simona Tecco
- Department of Dental Sciences, San Raffaele University, Milan Italy
| | - Carlo Mangano
- Department of Dental Sciences, San Raffaele University, Milan Italy
| | - Henriette Lerner
- Academic Teaching and Research Institution of Johann Wolfgang Goethe University, Frankfurt, Germany.
| | - Francesco Guido Mangano
- Department of Pediatric, Preventive Dentistry and Orthodontics, I. M. Sechenov First State Medical University, Moscow, Russian Federation.
| |
Collapse
|
2
|
Bjelopavlovic M, Goetze E, Kämmerer PW, Scheller H. Interdisciplinary all-on-four® concept for mandibular jaw in dental education - do students benefit from individual 3d printed models from real patient cases? Int J Implant Dent 2024; 10:10. [PMID: 38472534 DOI: 10.1186/s40729-024-00528-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Accepted: 03/05/2024] [Indexed: 03/14/2024] Open
Abstract
PURPOSE Digitalization is assuming increasing significance in dental education, as dental students are increasingly exposed to digital implant planning and contemporary technologies such as 3D printing. In this study, we present a cohort analysis aimed at assessing the potential benefits derived from the utilization of 3D prints to seamlessly translate planned procedures into real-life applications. METHODS 21 dental students participated in a virtual planning and hands-on course across two cohorts (C1: n = 10, C2: n = 11). The virtual implant planning phase involved the placement of four implants on an atrophic lower jaw model. Subsequently, Cohort 1 (C1) executed the implantation procedure on a prefabricated hands-on model, while Cohort 2 (C2) engaged with 3D prints representing their individual implant planning during the hands-on session. Subjective assessments of knowledge, skills, and the perceived utility of 3D prints were conducted through pre- and post-course questionnaires, utilizing a 5-point scale. RESULTS In the subjective evaluation, 17 out of 21 participants expressed a positive appraisal of the use of personalized models. Notably, there was no statistically significant improvement in overall knowledge scores; however, there was a discernible increase of 0.5 points in the ratings related to perceived expertise and procedural abilities. CONCLUSION While there was a notable increase in the subjective ratings of knowledge and abilities, no statistically significant difference was observed between the two groups. The consensus among dental students is that individually planned and printed implant models serve as a valuable and effective tool in hands-on courses.
Collapse
Affiliation(s)
- Monika Bjelopavlovic
- Department of Prosthetic Dentistry, University Medical Center of the Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131, Mainz, Germany.
| | - Elisabeth Goetze
- Department of Prosthetic Dentistry, University Medical Center of the Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131, Mainz, Germany
- Clinic of Cranio-Maxillofacial and Oral Surgery, University Hospital Zurich, University of Zurich, Rämistrasse 100, Zürich, 8091, Switzerland
| | - Peer W Kämmerer
- Department of Oral and Maxillofacial Surgery, University Medical Center of the Johannes-Gutenberg University, Augustusplatz 2, 55131, Mainz, Germany
| | - Herbert Scheller
- Department of Prosthetic Dentistry, University Medical Center of the Johannes Gutenberg-University Mainz, Augustusplatz 2, 55131, Mainz, Germany
| |
Collapse
|
3
|
Luongo F, Lerner H, Gesso C, Sormani A, Kalemaj Z, Luongo G. Accuracy in static guided implant surgery: Results from a multicenter retrospective clinical study on 21 patients treated in three private practices. J Dent 2024; 140:104795. [PMID: 38016619 DOI: 10.1016/j.jdent.2023.104795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 11/22/2023] [Accepted: 11/26/2023] [Indexed: 11/30/2023] Open
Abstract
PURPOSE To evaluate the accuracy of a static computer-assisted implant surgery (s-CAIS) system across different private practices. METHODS This retrospective clinical study was based on data retrieved from 21 patients who received 61 implants between 2018 and 2020 in 3 private practices run by surgeons with extensive experience with s-CAIS. All patients were treated using the same s-CAIS system, planning software, template manufacturing process, and surgical guides. The standard tessellation language (STL) file of the intraoral scan of the fixture taken immediately after implant placement was matched with that of the preoperative plan for comparisons of preoperative and planned implant positions with postoperative and actual implant positions. The study outcomes were linear and angular deviations between the planned and actual implant positions. RESULTS No surgical or postsurgical complications occurred. The overlap of the two STL files resulted in a mean angular deviation of 2.94° The mean linear deviation at the implant shoulder was 0.73 mm, and that at the apex was 1.06 mm. The mean vertical deviations at the implant shoulder and the apex were 0.29 mm and 0.01 mm, respectively. CONCLUSION All cases showed satisfactory accuracy within the limits of this study (small number of patients and retrospective design). These results might be related to the use of a standardized digital workflow by experienced operators. STATEMENT OF CLINICAL RELEVANCE The study shows that careful control of each step, from data acquisition to final execution, is key for the accuracy of stent-guided systems.
Collapse
Affiliation(s)
- Fabrizia Luongo
- MS, Private Practice, DDS, Via Frattina 27, Rome 00187, Italy.
| | | | | | - Alice Sormani
- Biomedical Engineer, International Consultant Medical Imaging and Guided Surgery Applications, 3Diemme srl Cantù, Italy
| | - Zamira Kalemaj
- PhD, MsC in Epidemiology and Statistics Private Practice, DDS, Milan, Italy
| | - Giuseppe Luongo
- MD, DDS, Department of Oral and Maxillofacial Surgery, Federico II University, Naples, Italy
| |
Collapse
|
4
|
Torres A, Dierickx M, Coucke W, Pedano MS, Lambrechts P, Jacobs R. In vitro study on the accuracy of sleeveless guided endodontics and treatment of a complex upper lateral incisor. J Dent 2023; 131:104466. [PMID: 36804580 DOI: 10.1016/j.jdent.2023.104466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 01/31/2023] [Accepted: 02/16/2023] [Indexed: 02/21/2023] Open
Abstract
PURPOSE The present study aims to assess the accuracy of sleeveless guided endodontics for root canal treatment of severe pulp canal obliteration (PCO) in 3D printed jaws. Additionally, the treatment of a complex lateral incisor is presented to illustrate the use of sleeveless guides in a clinical situation. METHODS Two cone-beam computed tomography (CBCT) volumes of an upper and lower jaw were selected to design 3D printed models with PCO. Virtual planning of the access cavities was performed from right to left second premolar. Then, the models were mounted into a phantom head to simulate an actual patient. Two operators with different levels of experience in endodontics performed guided access cavities. The handpiece was guided by guiding rails placed against each other on the sides of the tooth. A post-operative CBCT scan was taken for analysis. RESULTS Eighty-eight guided access cavities (44 per operator) were drilled on eight 3D printed models. The mean length of the access cavities was 15.3 mm, with a mean coronal and apical deviation of 0.5 mm and 0.7 mm respectively. The mean angular deviation was 1.5°. No statistically significant difference was found between operators for the three measured parameters. CONCLUSIONS This study demonstrates, within its limitations, that sleveless guides represent an accurate method for guided endodontic treatment. No statistically significant difference between operators was found when using the guide. CLINICAL SIGNIFICANCE This method offers a valuable alternative to conventional endodontic guides with similar accuracy results.
Collapse
Affiliation(s)
- A Torres
- OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium; Department of Oral Health Sciences, Endodontology, University Hospitals Leuven, KU Leuven, Leuven, Belgium.
| | - M Dierickx
- Department of Oral Health Sciences, Endodontology, University Hospitals Leuven, KU Leuven, Leuven, Belgium.
| | - W Coucke
- Certified Freelance Statistician, Heverlee, Belgium.
| | - M S Pedano
- Department of Oral Health Sciences, Endodontology, University Hospitals Leuven, KU Leuven, Leuven, Belgium.
| | - P Lambrechts
- Department of Oral Health Sciences, Endodontology, University Hospitals Leuven, KU Leuven, Leuven, Belgium.
| | - R Jacobs
- OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, KU Leuven, Leuven, Belgium; Department of Dental Medicine, Karolinska Institutet, Stockholm, Sweden.
| |
Collapse
|
5
|
Rothlauf S, Pieralli S, Wesemann C, Burkhardt F, Vach K, Kernen F, Spies BC. Influence of planning software and surgical template design on the accuracy of static computer assisted implant surgery performed using surgical guides fabricated with material extrusion technology: An in vitro study. J Dent 2023; 132:104482. [PMID: 36931618 DOI: 10.1016/j.jdent.2023.104482] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 03/05/2023] [Accepted: 03/14/2023] [Indexed: 03/17/2023] Open
Abstract
OBJECTIVES This in vitro study aimed to assess the influence of the planning software and design of the surgical template on both trueness and precision of static computer assisted implant surgery (sCAIS) performed using surgical guides fabricated using material extrusion (ME). METHODS Three-dimensional radiographic and surface scans of a typodont were aligned using two planning software (coDiagnostiX, CDX; ImplantStudio, IST) to virtually position the two adjacent oral implants. Thereafter, surgical guides were created with either an original (O) or modified (M) design with reduced occlusal support and were steam sterilized. Forty surgical guides were used to instal 80 implants equally distributed among four groups: CDX-O, CDX-M, IST-O, and IST-M. Thereafter, the scan bodies were adapted to the implants and digitised. Finally, inspection software was used to assess discrepancies between the planned and final positions at the implant shoulder and main axis level. Multilevel mixed-effects generalised linear models were used for statistical analyses (p = 0.05). RESULTS In terms of trueness, the largest average vertical deviations (0.29 ± 0.07 mm) could be assessed for CDX-M. Overall, vertical errors were significantly dependent on the design (O < M; p ≤ 0.001). Furthermore, in horizontal direction, the largest mean discrepancy was 0.32 ± 0.09 mm (IST-O) and 0.31 ± 0.13 mm (CDX-M). CDX-O was superior compared to IST-O (p = 0.003) regarding horizontal trueness. The average deviations regarding the main implant axis ranged between 1.36 ± 0.41 ° (CDX-O) and 2.63 ± 0.87 ° (CDX-M). In terms of precision, mean standard deviation intervals of ≤ 0.12 mm (IST-O and -M) and ≤ 1.09 ° (CDX-M) were calculated. CONCLUSIONS Implant installation with clinically acceptable deviations is possible with ME surgical guides. Both evaluated variables affected trueness and precision with negligible differences. CLINICAL SIGNIFICANCE The planning system and design influenced the accuracy of implant installation using ME-based surgical guides. Nevertheless, discrepancies were ≤ 0.32 mm and ≤ 2.63 °, which may be considered within the range of clinical acceptance. ME should be further investigated as an alternative to the more expensive and time-consuming 3D printing technologies.
Collapse
Affiliation(s)
- Severin Rothlauf
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine - University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany.
| | - Stefano Pieralli
- Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt - Universität zu Berlin and Berlin Institute of Health, Berlin, Germany.
| | - Christian Wesemann
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine - University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany.
| | - Felix Burkhardt
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine - University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany.
| | - Kirstin Vach
- Medical Center - University of Freiburg, Institute for Medical Biometry and Statistics, Faculty of Medicine, University of Freiburg, Zinkmattenstr. 6A, 79108, Freiburg, Germany.
| | - Florian Kernen
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Oral and Maxillofacial Surgery, Faculty of Medicine, University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany.
| | - Benedikt Christopher Spies
- Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine - University of Freiburg, Hugstetter Straße 55, 79106, Freiburg, Germany.
| |
Collapse
|
6
|
Block MS. How to Avoid Errors When Using Navigation to Place Implants - A Narrative Review. J Oral Maxillofac Surg 2023; 81:299-307. [PMID: 36481276 DOI: 10.1016/j.joms.2022.11.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 10/18/2022] [Accepted: 11/06/2022] [Indexed: 12/12/2022]
Abstract
PURPOSE Surgeons placing implants use navigation for implant placement accuracy. The importance of this review is to document the sources of error that are involved with navigation so surgeons can recognize factors to decrease error. The objective is to provide surgeons with a reference to optimize navigation. METHODS Pubmed.gov was the information source. Years reviewed included 2010 to 2022. The inclusion criteria included only articles in peer-reviewed journals. In vitro results were included only if they involved testing of variables microgap, cone beam computerized tomography (CBCT) accuracy evaluation, or accuracy of printed models. Variables were searched and evaluated. Data collected included the objectives and outcomes of the study including statistical significance. The conclusions made by the authors were confirmed by evaluating the data analysis, and then these conclusions were listed in each error-related topic. RESULTS The search used terms which included guided implant surgery complications (n = 4,029), accuracy of CBCT scanners (n = 319), accuracy of implant navigation (n = 983), and the error between drills and static guides (n = 3). From this search, 70 articles were collated that satisfied the inclusion criteria. There are multiple sources of error that are less than 1 mm, including but not limited to errors associated with the scanner and method for scanning, errors associated with merging scanned files with the CBCT scan, errors using different guide stent fabrication methods, errors associated with intraoperative techniques, the learning curve, and planning error. If small errors are not taken into consideration, implant placement errors can exceed 1-2 mm of platform location and angulation errors in excess of 8°. CONCLUSION The surgeon needs to take into consideration controllable factors that will result in the avoidance of implant malposition and thus be able to effectively utilize navigation for accurate implant placement.
Collapse
Affiliation(s)
- Michael S Block
- Private Practice, Metairie, LA, Clinical Professor, LSU School of Dentistry, Department of Oral and Maxillofacial Surgery, Metairie, LA.
| |
Collapse
|
7
|
FEM Analysis of Individualized Polymeric 3D Printed Guide for Orthodontic Mini-Implant Insertion as Temporary Crown Support in the Anterior Maxillary Area. Polymers (Basel) 2023; 15:polym15040879. [PMID: 36850161 PMCID: PMC9966125 DOI: 10.3390/polym15040879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 01/13/2023] [Accepted: 02/07/2023] [Indexed: 02/12/2023] Open
Abstract
Either due to trauma, extraction or congenital factors, the absence of teeth has aesthetic, functional, financial and psychological consequences. The aim of the current study is to assess an individualized polymeric 3D printed digitally planned surgical guide designed to achieve precision and predictability in non-standard mini-implant orthodontic cases. Twenty-seven patient records with missing anterior teeth were selected from the database of a private clinic in Timisoara, Romania. Based on the analysis of the cases included in the research, a surgical guide for the insertion of mini-implants as provisional crown support was designed. An FEM simulation was performed using the Abaqus numerical analysis software. Finite element simulation revealed the maximum displacements and stresses that occur in the surgical guide. Mini-implant supported provisional crowns can be a simple and low-cost method to increase patient self-esteem and compliance with the orthodontic treatment. Computer aided mechanical simulation is a useful tool in analyzing different polymeric surgical guide designs before being used in clinical situations in order to avoid failure.
Collapse
|
8
|
Huang S, Wei H, Li D. Additive manufacturing technologies in the oral implant clinic: A review of current applications and progress. Front Bioeng Biotechnol 2023; 11:1100155. [PMID: 36741746 PMCID: PMC9895117 DOI: 10.3389/fbioe.2023.1100155] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 01/11/2023] [Indexed: 01/21/2023] Open
Abstract
Additive manufacturing (AM) technologies can enable the direct fabrication of customized physical objects with complex shapes, based on computer-aided design models. This technology is changing the digital manufacturing industry and has become a subject of considerable interest in digital implant dentistry. Personalized dentistry implant treatments for individual patients can be achieved through Additive manufacturing. Herein, we review the applications of Additive manufacturing technologies in oral implantology, including implant surgery, and implant and restoration products, such as surgical guides for implantation, custom titanium meshes for bone augmentation, personalized or non-personalized dental implants, custom trays, implant casts, and implant-support frameworks, among others. In addition, this review also focuses on Additive manufacturing technologies commonly used in oral implantology. Stereolithography, digital light processing, and fused deposition modeling are often used to construct surgical guides and implant casts, whereas direct metal laser sintering, selective laser melting, and electron beam melting can be applied to fabricate dental implants, personalized titanium meshes, and denture frameworks. Moreover, it is sometimes required to combine Additive manufacturing technology with milling and other cutting and finishing techniques to ensure that the product is suitable for its final application.
Collapse
Affiliation(s)
| | - Hongbo Wei
- State Key Laboratory of Military Stomatology, National Clinical Research Center for Oral Diseases, Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi’an, Shaanxi, China
| | - Dehua Li
- State Key Laboratory of Military Stomatology, National Clinical Research Center for Oral Diseases, Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi’an, Shaanxi, China
| |
Collapse
|
9
|
Pimkhaokham A, Jiaranuchart S, Kaboosaya B, Arunjaroensuk S, Subbalekha K, Mattheos N. Can computer-assisted implant surgery improve clinical outcomes and reduce the frequency and intensity of complications in implant dentistry? A critical review. Periodontol 2000 2022; 90:197-223. [PMID: 35924457 PMCID: PMC9805105 DOI: 10.1111/prd.12458] [Citation(s) in RCA: 37] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Computer-assisted implant surgery (CAIS), either static or dynamic, is well documented to significantly improve the accuracy of implant placement. Whether the increased accuracy leads to a corresponding improvement in clinical outcomes has not yet been systematically investigated. The aim of this critical review was to investigate whether the use of CAIS can lead to reduction of complications as well as improved clinical and patient-reported outcomes (PROs) when compared with conventional freehand implant surgery. A comprehensive online search was conducted to identify studies where implants were installed with static computer-assisted implant surgery (s-CAIS)or dynamic computer-assisted implant surgery(d-CAIS) or combinations of the two, either compared with conventional free-hand implant placement or not. Seventy-seven studies were finally included in qualitative analysis, while data from three studies assessing postsurgical pain were suitable for a meta-analysis. Only a small number of the available studies were comparative. The current evidence does not suggest any difference with regard to intraoperative complications, immediate postsurgical healing, osseointegration success, and survival of implants placed with CAIS or freehand protocols. Intraoperative and early healing events as reported by patients in randomized clinical trials (RCTs) did not differ significantly between CAIS used with flap elevation and conventional implant placement. There is limited evidence that increased accuracy of placement with CAIS is correlated with superior esthetic outcomes. Use of CAIS does not significantly reduce the length of surgeries in cases of single implants and partially edentulous patients, although there appears to be a more favorable impact in fully edentulous patients. Although CAIS alone does not seem to improve healing and the clinical and PRO, to the extent that it can increase the utilization of flapless surgery and predictability of immediacy protocols, its use may indirectly lead to substantial improvements in all of the above parameters.
Collapse
Affiliation(s)
- Atiphan Pimkhaokham
- Department of Oral and Maxillofacial Surgery, Faculty of DentistryChulalongkorn UniversityBangkokThailand
| | - Sirimanas Jiaranuchart
- Department of Oral and Maxillofacial Surgery, Faculty of DentistryChulalongkorn UniversityBangkokThailand
| | - Boosana Kaboosaya
- Department of Oral and Maxillofacial Surgery, Faculty of DentistryChulalongkorn UniversityBangkokThailand
| | - Sirida Arunjaroensuk
- Department of Oral and Maxillofacial Surgery, Faculty of DentistryChulalongkorn UniversityBangkokThailand
| | - Keskanya Subbalekha
- Department of Oral and Maxillofacial Surgery, Faculty of DentistryChulalongkorn UniversityBangkokThailand
| | - Nikos Mattheos
- Department of Oral and Maxillofacial Surgery, Faculty of DentistryChulalongkorn UniversityBangkokThailand,Department of Dental MedicineKarolinska InstituteStockholmSweden
| |
Collapse
|
10
|
Differences Between Impression Stone Pouring and Digital Pouring in Fully Guided Dental Implant Surgery: A Prospective Clinical Study. J Craniofac Surg 2022; 33:e890-e895. [DOI: 10.1097/scs.0000000000008947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Accepted: 07/12/2022] [Indexed: 11/26/2022] Open
|
11
|
Abduo J, Lau D. Duration, deviation and operator's perception of static computer assisted implant placements by inexperienced clinicians. EUROPEAN JOURNAL OF DENTAL EDUCATION : OFFICIAL JOURNAL OF THE ASSOCIATION FOR DENTAL EDUCATION IN EUROPE 2022; 26:477-487. [PMID: 34797018 DOI: 10.1111/eje.12724] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 09/19/2021] [Accepted: 09/27/2021] [Indexed: 06/13/2023]
Abstract
INTRODUCTION This study measured the duration, deviation and operator's perception of implant placement by fully guided (FG), pilot-guided (PG) and freehand (FH) protocols by postgraduate students with minimal implant experience. MATERIALS AND METHODS Twenty postgraduate students participated in the study. Half of them placed single anterior (S-Ant) and single posterior (S-Post) implants, and the other half placed anterior (B-Ant) and posterior (B-Post) implants in a wide edentulous area. The PG placement involved surgical guides that only controlled pilot drilling, whilst the FG placement controlled all the drilling steps and implant placement. The duration of implant placement and the operator's perception (ease of drilling, ease of implant placement and operator's preference) were measured. The deviations of placed implants were quantified by measuring the trueness and angulation deviations in relation to the planned implants. RESULTS The PG placement was the quickest for inserting implants, followed by FG and FH placements, respectively (p < .05). The location of the implant had influenced the duration of implant placement only for the PG placement. In relation to ease of drilling, ease of implant placement and operator's preference, there was no significant difference amongst the different placement protocols or implant locations. The FG placement was associated with least deviations, followed by PG and FH placements, respectively (p < .05). CONCLUSIONS In the hands of postgraduate students with minimal implant experience, FG and PG placements reduced the implant placement duration in comparison with FH placement. The FG placement was consistently more accurate followed by PG placement.
Collapse
Affiliation(s)
- Jaafar Abduo
- Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Douglas Lau
- Private Practice, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| |
Collapse
|
12
|
Medical 3D Printing with a focus on Point-of-Care in Cranio- and Maxillofacial Surgery. A systematic review of literature. ANNALS OF 3D PRINTED MEDICINE 2022. [DOI: 10.1016/j.stlm.2022.100059] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
|
13
|
Main Applications and Recent Research Progresses of Additive Manufacturing in Dentistry. BIOMED RESEARCH INTERNATIONAL 2022; 2022:5530188. [PMID: 35252451 PMCID: PMC8894006 DOI: 10.1155/2022/5530188] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 12/16/2021] [Accepted: 01/28/2022] [Indexed: 12/13/2022]
Abstract
In recent ten years, with the fast development of digital and engineering manufacturing technology, additive manufacturing has already been more and more widely used in the field of dentistry, from the first personalized surgical guides to the latest personalized restoration crowns and root implants. In particular, the bioprinting of teeth and tissue is of great potential to realize organ regeneration and finally improve the life quality. In this review paper, we firstly presented the workflow of additive manufacturing technology. Then, we summarized the main applications and recent research progresses of additive manufacturing in dentistry. Lastly, we sketched out some challenges and future directions of additive manufacturing technology in dentistry.
Collapse
|
14
|
Wang ZY, Chao JR, Zheng JW, You M, Liu Y, Shen JF. The influence of crown coverage on the accuracy of static guided implant surgery in partially edentulous models: An in vitro study. J Dent 2021; 115:103882. [PMID: 34742831 DOI: 10.1016/j.jdent.2021.103882] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 10/28/2021] [Accepted: 11/01/2021] [Indexed: 02/08/2023] Open
Abstract
OBJECTIVE To evaluate the influence of crown coverage of surgical guides on the accuracy of static computer-assisted implant surgeries (sCAISs) in different partially edentulous situations. METHODS Acrylic models with five types of partially edentulous situations were fabricated in this study. In coDiagnostiX software (Dental Wings, Montreal, Canada), surgical templates were designed and fabricated with reduced crown coverage (RCC), standard crown coverage (SCC) and extended crown coverage (ECC). Then, fully guided implant placement into the acrylic models was performed by dental surgeons with more than 10 years of experience. In total, 120 models and 120 guides were manufactured, and 168 bone-level Straumann replica implants (4.1 × 10 mm, Institut Straumann AG, Basel, Switzerland) were inserted. Postoperative implant positions were scanned (Trios 3, 3 shape, Copenhagen, Denmark) and compared with the preplanned virtual positions via coDiagnostiX (Dental Wings, Montreal, Canada). The angular, coronal and apical deviations were measured and analyzed to evaluate the accuracy of implant insertion. Statistical analysis was performed using one-way ANOVA and Tukey's test. RESULTS For single tooth missing situations, the RCC group was similar to the SCC group and ECC group in anterior sites. In premolar or molar sites, the SCC and ECC groups had no statistically significant difference (p > .05), while the RCC group had more coronal and apical deviation (p < .05). For multiple teeth missing situations, there was no difference among the RCC, SCC and ECC groups (p > .05). No difference was found among the five edentulous situations with different CCs (p > .05). CONCLUSION The CC of templates can significantly affect the accuracy of guided surgeries when implants are inserted in a single gap at posterior sites. Templates with CC extended to the undercut line may be an optimal choice for static guided surgeries. CLINICAL SIGNIFICANCE The accuracy of static guided implant surgery can be influenced by the CC of templates, and proper CC with the guide covering extending to the undercut line may contribute to improved accuracy. CC should be taken into consideration when designing surgical templates.
Collapse
Affiliation(s)
- Zhen-Yu Wang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Chengdu, Sichuan Province, China; West China School of Stomatology, Sichuan University, Chengdu, Sichuan Province, China
| | - Jia-Rui Chao
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Chengdu, Sichuan Province, China; West China School of Stomatology, Sichuan University, Chengdu, Sichuan Province, China
| | - Jia-Wen Zheng
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Chengdu, Sichuan Province, China; West China School of Stomatology, Sichuan University, Chengdu, Sichuan Province, China
| | - Meng You
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Chengdu, Sichuan Province, China; West China School of Stomatology, Sichuan University, Chengdu, Sichuan Province, China; Department of Radiology, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan Province, China
| | - Yang Liu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Chengdu, Sichuan Province, China; West China School of Stomatology, Sichuan University, Chengdu, Sichuan Province, China; The Department of Temporomandibular Joint, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan Province, China
| | - Jie-Fei Shen
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Chengdu, Sichuan Province, China; West China School of Stomatology, Sichuan University, Chengdu, Sichuan Province, China; Department of Prosthodontics II, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan Province, China.
| |
Collapse
|
15
|
Yang JW, Liu Q, Yue ZG, Hou JX, Afrashtehfar KI. Digital Workflow for Full-Arch Immediate Implant Placement Using a Stackable Surgical Guide Fabricated Using SLM Technology. J Prosthodont 2021; 30:645-650. [PMID: 33938077 DOI: 10.1111/jopr.13375] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/29/2021] [Indexed: 12/19/2022] Open
Abstract
The failing dentition of partially edentulous individuals may be used as an initial reference for stackable restrictive surgical guides during full-arch immediate implant placement. The stackable guide option derived from a digital workflow increases the predictability of the performance of bone reduction, immediate implant placement, and immediate loading of provisional implant-supported fixed dental prostheses. The present paper aims to report a practical approach to design and produce a metal framework with occlusal rests to facilitate the use of a tooth-supported surgical guide when full-arch immediate implant placement is indicated in patients with failing dentition.
Collapse
Affiliation(s)
- Jing-Wen Yang
- Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, PR China.,National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing, PR China.,Research Center of Engineering and Technology for Digital Dentistry of Ministry of Health, Beijing Key Laboratory of Digital Stomatology, Beijing, PR China
| | - Qi Liu
- Private practice, Beijing, PR China
| | - Zhao-Guo Yue
- Department of Periodontology, Peking University School and Hospital of Stomatology, Beijing, PR China
| | - Jian-Xia Hou
- National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing, PR China.,Research Center of Engineering and Technology for Digital Dentistry of Ministry of Health, Beijing Key Laboratory of Digital Stomatology, Beijing, PR China.,Department of Periodontology, Peking University School and Hospital of Stomatology, Beijing, PR China
| | - Kelvin I Afrashtehfar
- Division of Restorative Dental Sciences, Department of Clinical Sciences, College of Dentistry, Ajman University, Ajman City, UAE.,Department of Reconstructive Dentistry & Gerodontology, School of Dental Medicine, Faculty of Medicine, University of Bern, Berne, Switzerland.,Center of Medical and Bio-allied Health Sciences Research, Ajman University, Dubai, United Arab Emirates
| |
Collapse
|
16
|
Digital Approach for the Rehabilitation of the Edentulous Maxilla with Pterygoid and Standard Implants: The Static and Dynamic Computer-Aided Protocols. Methods Protoc 2020; 3:mps3040084. [PMID: 33371232 PMCID: PMC7768480 DOI: 10.3390/mps3040084] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2020] [Revised: 12/16/2020] [Accepted: 12/17/2020] [Indexed: 11/16/2022] Open
Abstract
A full-arch rehabilitation of the edentulous upper jaw without grafting procedures exploits the residual alveolar or the basal bone, with the necessity of long implants placed with a particular orientation. The precision in planning and placing the fixtures is fundamental to avoid clinical problems and to allow an acceptable connection with the prosthesis. The computer-aided implantology resulted in more accuracy than the traditional one, with a high standard of correspondence between the virtual project and the real outcome. This paper reports about the two different digital protocols, static and dynamic, as support to implant-borne prosthetic rehabilitation of edentulous maxillae. Two pterygoid and two/four anterior standard implants were seated in both cases by two different operators, without flap raising, and immediately loaded. This approach avoided the posterior cantilever by-passing the maxillary sinus and was adequately planned and realized without any surgical or prosthetic error. The two digital flow-charts were described step by step, underlining each other’s advantages and drawbacks compared to a free-hand approach.
Collapse
|
17
|
Torres A, Lerut K, Lambrechts P, Jacobs R. Guided Endodontics: Use of a Sleeveless Guide System on an Upper Premolar with Pulp Canal Obliteration and Apical Periodontitis. J Endod 2020; 47:133-139. [PMID: 33045264 DOI: 10.1016/j.joen.2020.09.016] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 09/04/2020] [Accepted: 09/10/2020] [Indexed: 11/27/2022]
Abstract
Guided endodontics has been used for the treatment of anterior teeth with a successful outcome. This approach is not only limited to anterior teeth because it can also be used for the treatment of premolars and molars. However, in such cases, space may be a limitation because a long bur has to be used in addition to the guide being placed on top of the teeth. The aim of this case report was to present a novel guided endodontics technique using a sleeveless 3-dimensional-printed guide. This design can reduce vertical space, allowing an open view of the tooth and irrigation during drilling. A 46-year-old female patient consulted the endodontic department with intermittent pain around tooth #5. Tooth #5 presented pain upon percussion and responded negative to a cold test. The initial periapical radiograph revealed an apical radiolucency with pulp canal obliteration. Clinically, there was no sinus tract. The tooth was diagnosed with pulp necrosis and symptomatic apical periodontitis. Guided endodontic treatment was performed with a sleeveless 3-dimensional-printed guide and long neck carbide bur with a head diameter of 1 mm to drill a minimally invasive access cavity up to the root canal. A completely healed apical area of tooth #5 was visible after 1 year on periapical radiographs. This technique seems to be a promising alternative in comparison with the conventional guided endodontic guide design for the negotiation of pulp canal obliteration in cases in which vertical space is limited.
Collapse
Affiliation(s)
- Andres Torres
- OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven, Leuven, Belgium; Department of Oral Health Sciences, University Hospitals Leuven, Endodontology, KU Leuven, Leuven, Belgium.
| | - Kathleen Lerut
- Department of Oral Health Sciences, University Hospitals Leuven, Endodontology, KU Leuven, Leuven, Belgium
| | - Paul Lambrechts
- Department of Oral Health Sciences, University Hospitals Leuven, Endodontology, KU Leuven, Leuven, Belgium
| | - Reinhilde Jacobs
- OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven, Leuven, Belgium; Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium; Department of Dental Medicine, Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
18
|
Stefanelli LV, Pranno N, De Angelis F, La Rosa S, Polimeni A, Di Carlo S. Navigated Antral Bone Expansion (NABE): a prospective study on 35 patients with 4 months of follow-up post implant loading. BMC Oral Health 2020; 20:273. [PMID: 33028292 PMCID: PMC7542702 DOI: 10.1186/s12903-020-01268-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Accepted: 09/30/2020] [Indexed: 11/10/2022] Open
Abstract
Background The insertion of dental implants in the atrophic posterior maxilla can be a challenge. One option is to modify the residual native bone in preparation for proper, prosthetically-driven implant placement. The procedure presented in this study is called Navigated Antral Bone Expansion (N.A.B.E). This procedure employs the use of a navigation system to plan and guide the initial pilot drilling, bone expansion, final site preparation, and implant insertion. The aim of this study was to compare the distance between the alveolar ridge and the sinus floor measured before and after the surgery performed using the N.A.B.E. technique. Methods Thirty-seven partially edentulous patients who were candidates for implant supported restoration in the posterior maxilla, with a bone height ranging from 4 to 7 mm were enrolled. The N.A.B.E procedure was used to increase the bone height. Paired-samples t-test evaluated the distance between the alveolar ridge and the sinus floor measured before and after surgery. The occurrence of post-surgical complications, and the angular deviation between the planned osteotomy and the actual placed implant trajectories were evaluated. Results Out of the 37 consecutive patients enrolled in the study, 35 were considered in the data analyses. Patients’ bone height after surgery compared to the bone height before surgery showed a statistically significant increase (p < .0005) of 3.96 mm (95% CI, 3.62 mm to 4.30 mm). No post-operative complications were observed in the 35 patients. The mean angular deviation between the planned osteotomy trajectory and the placed implant trajectory ranged between 12.700 to 34.900 (mean 25.170 ± 5.100). Conclusions This study provides evidence that N.A.B.E. technique is able to provide a significant bone increase, and could be considered an alternative method to the management of the atrophic posterior maxilla with a minimally invasive approach.
Collapse
Affiliation(s)
| | - Nicola Pranno
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, 6. Caserta St., 00161, Rome, Italy.
| | - Francesca De Angelis
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, 6. Caserta St., 00161, Rome, Italy
| | - Silvia La Rosa
- Private Practice, Periodontics and Dental Implant Surgery, Tacoma, Washington, USA
| | - Antonella Polimeni
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, 6. Caserta St., 00161, Rome, Italy
| | - Stefano Di Carlo
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, 6. Caserta St., 00161, Rome, Italy
| |
Collapse
|
19
|
Stefanelli LV, Mandelaris GA, Franchina A, Pranno N, Pagliarulo M, Cera F, Maltese F, De Angelis F, Di Carlo S. Accuracy of Dynamic Navigation System Workflow for Implant Supported Full Arch Prosthesis: A Case Series. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:E5038. [PMID: 32668790 PMCID: PMC7400369 DOI: 10.3390/ijerph17145038] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/23/2020] [Revised: 07/06/2020] [Accepted: 07/07/2020] [Indexed: 12/31/2022]
Abstract
A minimally invasive implant treatment approach for future full arch implant prosthetic rehabilitations of trophic jaws represents a challenge. An optimal implant planning is strongly related with an accurate merge of the prosthetic information and the radiographic data. To comply with that, most computer aided implantology (CAI) systems require additional steps, as radiographic stents or fiducial markers to overlap digital jaw scans to cone beam computed tomography (CBCT) data. Using dynamic CAI, residual teeth (up to three) make it possible for the merge to avoid new radiographic scans. An additional challenge is the treatment involving immediate implants compared with delayed implants placed into healed bone. As for other static CAI systems, the operator's experience and the quality of the CBCT data make the planning affordable and secure the entire implants placement procedure. The literature reports accuracies in terms of comparison between placed implants and planned implants, following a double CBCT approach, based on radiographic volume overlapping. Thirteen consecutive future totally edentulous patients (77 implants), divided into two groups (group A: 3-4 teeth traced; group B: 5-6 teeth traced) requiring a full arch implant prosthetic rehabilitation were included in the reported case series. A dynamic CAI was used to plan and to place all implants following all the recommended digital steps. The software used provided a tool (Trace and Place) that made the merge between X-ray views of the residual teeth and their own positions possible. This method definitely registered that teeth positions comply with the required accuracy live check. After implants placement, a post-operative CBCT was taken in order to evaluate the deviations of the achieved implants at coronal, apical, and depth level as well as angular deviations. Statistically significant radiological mean difference between the two groups was found in the coronal position of implants (0.26 mm, p < 0.001), in the apical position of implants (0.29 mm, p < 0.001), in the depth of implants (0.16 mm, p = 0.022), and in the angular deviation (0.7, p = 0.004). The use of the TaP technology for the treatment of the patients with at least three stable teeth that need to be removed for a totally implant prosthetic treatment is a promising technique. The performed accuracy analysis demonstrated that this digital protocol can be used without a loss of accuracy of the achieved implants compared to planned ones.
Collapse
Affiliation(s)
- Luigi V. Stefanelli
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome; 00185 Rome, Italy; (L.V.S.); (F.D.A.); (S.D.C.)
| | - George A. Mandelaris
- Private Practice, Periodontics and Dental Implant Surgery, Chicago, IL 60181, USA;
- Department of Graduate Periodontics, College of Dentistry, University of Illinois, Chicago, IL 60612, USA
| | - Alessio Franchina
- Private Practice, Periodontics and Dental Implant Surgery, 36100 Vicenza, Italy;
| | - Nicola Pranno
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome; 00185 Rome, Italy; (L.V.S.); (F.D.A.); (S.D.C.)
| | - Michele Pagliarulo
- Dental Student University of Plovdiv-Bulgary, 4000 Plovdiv, Bulgary; (M.P.); (F.C.)
| | - Francesca Cera
- Dental Student University of Plovdiv-Bulgary, 4000 Plovdiv, Bulgary; (M.P.); (F.C.)
| | | | - Francesca De Angelis
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome; 00185 Rome, Italy; (L.V.S.); (F.D.A.); (S.D.C.)
| | - Stefano Di Carlo
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome; 00185 Rome, Italy; (L.V.S.); (F.D.A.); (S.D.C.)
| |
Collapse
|
20
|
Stefanelli LV, Mandelaris GA, Franchina A, Di Nardo D, Galli M, Pagliarulo M, Testarelli L, Di Carlo S, Gambarini G. Accuracy Evaluation of 14 Maxillary Full Arch Implant Treatments Performed with Da Vinci Bridge: A Case Series. MATERIALS 2020; 13:ma13122806. [PMID: 32580340 PMCID: PMC7344455 DOI: 10.3390/ma13122806] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2020] [Revised: 06/07/2020] [Accepted: 06/18/2020] [Indexed: 11/29/2022]
Abstract
The use of pterygoid implants can be an attractive alternative to sinus bone grafting in the treatment of posterior atrophic maxilla. This technique has not been widely used because of the difficulty of the surgical access, the presence of vital structures, and the prosthetic challenges. The use of dynamic computer aided implantology (DCAI) allows the clinician to utilize navigation dental implant surgery, which allows the surgeon to follow the osteotomy site and implant positioning in real time. A total of 14 patients (28 pterygoid implants and 56 intersinusal implants) were enrolled in the study for a full arch implant prosthetic rehabilitation (4 frontal implants and 2 pterygoids implants), using a dynamic navigation system. The reported accuracy of pterygoid implants inserted using DCAI was 0.72 mm at coronal point, 1.25 mm at apical 3D, 0.66 mm at apical depth, and 2.86° as angular deviation. The use of pterygoid implants in lieu of bone grafting represents a valid treatment opportunity to carry out a safe, accurate, and minimally invasive surgery, while reducing treatment time and avoiding cantilevers for a full implant prosthetic rehabilitation of the upper arch.
Collapse
Affiliation(s)
- Luigi V. Stefanelli
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, 00161 Rome, Italy; (L.V.S.); (M.G.); (L.T.); (S.D.C.); (G.G.)
| | - George A. Mandelaris
- Private Practice, Periodontics and Dental Implant Surgery; Periodontal Medicine & Surgical Specialists, LTD, Chicago, IL 60601, USA;
| | - Alessio Franchina
- Private Practice, Periodontics and Dental Implant Surgery, 36100 Vicenza, Italy;
| | - Dario Di Nardo
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, 00161 Rome, Italy; (L.V.S.); (M.G.); (L.T.); (S.D.C.); (G.G.)
- Correspondence: ; Tel.: +39-339-3935-527
| | - Massimo Galli
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, 00161 Rome, Italy; (L.V.S.); (M.G.); (L.T.); (S.D.C.); (G.G.)
| | - Michele Pagliarulo
- Faculty of Dental Medicine, University of Plovdiv, 4002 Plovdiv, Bulgary;
| | - Luca Testarelli
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, 00161 Rome, Italy; (L.V.S.); (M.G.); (L.T.); (S.D.C.); (G.G.)
| | - Stefano Di Carlo
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, 00161 Rome, Italy; (L.V.S.); (M.G.); (L.T.); (S.D.C.); (G.G.)
| | - Gianluca Gambarini
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, 00161 Rome, Italy; (L.V.S.); (M.G.); (L.T.); (S.D.C.); (G.G.)
| |
Collapse
|
21
|
Lerner H, Hauschild U, Sader R, Ghanaati S. Complete-arch fixed reconstruction by means of guided surgery and immediate loading: a retrospective clinical study on 12 patients with 1 year of follow-up. BMC Oral Health 2020; 20:15. [PMID: 31948414 PMCID: PMC6966809 DOI: 10.1186/s12903-019-0941-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Accepted: 10/28/2019] [Indexed: 12/18/2022] Open
Abstract
Background Guided implant surgery is considered as a safe and minimally invasive flapless procedure. However, flapless guided surgery, implant placement in post-extraction sockets and immediate loading of complete-arch fixed reconstructions without artificial gum are still not throughly evaluated. The aim of the present retrospective clinical study was to document the survival and success of complete-arch fixed reconstructions without artificial gum, obtained by means of guided surgery and immediate loading of implants placed also in fresh extraction sockets. Methods A total of 12 patients (5 males and 7 females, with a mean age of 50.0 ± 13.8) were enrolled in this study. Implant planning was performed with a guided surgery system (RealGuide®, 3Diemme, Como, Italy), from which 3D-printed surgical templates were fabricated. All implants (Esthetic Line-EL®, C-Tech, Bologna, Italy) were placed through the guides and immediately loaded by means of a temporary fixed full-arch restoration without any artificial gum; the outcome measures were implant stability at placement, implant survival, complications, prosthetic success, soft-tissue stability, and patient satisfaction. Results One hundred ten implants (65 of them post-extractive) were placed flapless through a guided surgery procedure and then immediately loaded by means of provisional fixed full arches. Successful implant stability at placement was achieved in all cases. After a provisionalization period of 6 months, 72 fixed prosthetic restorations were delivered. Only 2 implants failed to osseointegrate and had to be removed, in one patient, giving a 1-year implant survival rate of 98.2% (108/110 surviving implants); 8/12 prostheses did not undergo any failure or complication during the entire follow-up period. At the 1-year follow-up control, soft-tissue was stable in all patients and showed satesfactory aesthetic results. Conclusions Within the limits of this study, complete-arch fixed reconstruction by means of guided surgery and immediate loading of implants placed in fresh extraction sockets appears to be a reliable and successful procedure. Further long-term prospective studies on a larger sample of patients are needed to confirm these positive outcomes.
Collapse
Affiliation(s)
- Henriette Lerner
- , Baden-Baden, Germany. .,Department of Oral, Cranio-Maxillofacial and Facial Plastic Surgery, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany.
| | - Uli Hauschild
- Department of Post-Graduate Medicine, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany.,, Sanremo, Italy
| | - Robert Sader
- Department of Oral, Cranio-Maxillofacial and Facial Plastic Surgery, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany
| | - Shahram Ghanaati
- Department of Oral, Cranio-Maxillofacial and Facial Plastic Surgery, Medical Center of the Goethe University Frankfurt, Frankfurt am Main, Germany.,Institute of Pathology, University Medical Center, Johannes Gutenberg University, Mainz, Germany
| |
Collapse
|
22
|
Mouhyi J, Salama MA, Mangano FG, Mangano C, Margiani B, Admakin O. A novel guided surgery system with a sleeveless open frame structure: a retrospective clinical study on 38 partially edentulous patients with 1 year of follow-up. BMC Oral Health 2019; 19:253. [PMID: 31752811 PMCID: PMC6873693 DOI: 10.1186/s12903-019-0940-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Accepted: 10/28/2019] [Indexed: 01/23/2023] Open
Abstract
Background This retrospective clinical study aims to present results of experience with a novel guided surgery system with a sleeveless, open-frame structure, in which the surgical handpiece (not the drills used for preparation) is guided. Methods This study was based on an evaluation of the records of partially edentulous patients who had been treated with a sleeveless open-frame guided surgery system (TWIN-Guide®, 2Ingis, Brussels, Belgium), between January 2015 and December 2017. Inclusion criteria were patients with good systemic/oral health and a minimum follow-up of 1 year. Exclusion criteria were patients who had been treated without a guide, or with a guide with sleeves, patients with systemic/oral diseases and who did not have a follow-up of 1 year. The main outcomes were surgical (fit and stability of the surgical guide, duration of the intervention, implant stability, and any intra-operative or immediate post-operative complication), biologic, and prosthetic. Results Thirty-eight patients (24 males, 14 females; mean age 56.5 ± 14.0 years) were included in the study. These patients had been treated with 110 implants inserted by means of 40 sleeveless, open-frame guides. With regard to fit and stability, 34 guides were excellent, 4 acceptable, and 2 inadequate for use. The mean duration of the intervention was 23.7 (± 6.7) minutes. Immediately after placement, 2 fixtures were not stable and had to be removed. Two patients experienced pain/swelling after surgery. The 108 surviving implants were restored with 36 single crowns and 32 fixed partial prostheses (24 two-unit and 8 three-unit bridges); these restorations survived until the 1-year follow-up, with a low incidence of biologic and prosthetic complications. Conclusions Within the limits of this study, this novel guided surgery system with sleeveless, open frame–structure guides seems to be clinically reliable; further studies on a larger sample of patients are needed to confirm these outcomes.
Collapse
Affiliation(s)
- Jaafar Mouhyi
- Casablanca Oral Rehabilitation Training & Education Center (CORTEC), Casablanca, Morocco. .,Biomaterials Research Department, International University of Agadir (Universiapolis), 8143, Agadir, Morocco.
| | - Maurice Albert Salama
- Department of Periodontics, University of Pennsylvania, Philadelphia, PA, USA.,Department of Periodontics, Medical College of Georgia, Atlanta, GE, USA
| | - Francesco Guido Mangano
- Department of Prevention and Communal Dentistry, Sechenov First Moscow State Medical University, 119992, Moscow, Russia
| | - Carlo Mangano
- Department of Dental Sciences, Vita and Salute University, San Raffaele, Milan, Italy
| | - Bidzina Margiani
- Department of Prevention and Communal Dentistry, Sechenov First Moscow State Medical University, 119992, Moscow, Russia
| | - Oleg Admakin
- Department of Prevention and Communal Dentistry, Sechenov First Moscow State Medical University, 119992, Moscow, Russia
| |
Collapse
|
23
|
Mangano FG, Hauschild U, Veronesi G, Imburgia M, Mangano C, Admakin O. Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study. BMC Oral Health 2019; 19:101. [PMID: 31170969 PMCID: PMC6555024 DOI: 10.1186/s12903-019-0792-7] [Citation(s) in RCA: 133] [Impact Index Per Article: 26.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Accepted: 05/20/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Until now, a few studies have addressed the accuracy of intraoral scanners (IOSs) in implantology. Hence, the aim of this in vitro study was to assess the accuracy of 5 different IOSs in the impressions of single and multiple implants, and to compare them. METHODS Plaster models were prepared, representative of a partially edentulous maxilla (PEM) to be restored with a single crown (SC) and a partial prosthesis (PP), and a totally edentulous maxilla (TEM) to be restored with a full-arch (FA). These models were scanned with a desktop scanner, to capture reference models (RMs), and with 5 IOSs (CS 3600®, Trios3®, Omnicam®, DWIO®, Emerald®); 10 scans were taken for each model, using each IOS. All IOS datasets were loaded into a reverse-engineering software where they were superimposed on the corresponding RMs, to evaluate trueness, and superimposed on each other within groups, to determine precision. A statistical analysis was performed. RESULTS In the SC, CS 3600® had the best trueness (15.2 ± 0.8 μm), followed by Trios3® (22.3 ± 0.5 μm), DWIO® (27.8 ± 3.2 μm), Omnicam® (28.4 ± 4.5 μm), Emerald® (43.1 ± 11.5 μm). In the PP, CS 3600® had the best trueness (23 ± 1.1 μm), followed by Trios3® (28.5 ± 0.5 μm), Omnicam® (38.1 ± 8.8 μm), Emerald® (49.3 ± 5.5 μm), DWIO® (49.8 ± 5 μm). In the FA, CS 3600® had the best trueness (44.9 ± 8.9 μm), followed by Trios3® (46.3 ± 4.9 μm), Emerald® (66.3 ± 5.6 μm), Omnicam® (70.4 ± 11.9 μm), DWIO® (92.1 ± 24.1 μm). Significant differences were found between the IOSs; a significant difference in trueness was found between the contexts (SC vs. PP vs. FA). In the SC, CS 3600® had the best precision (11.3 ± 1.1 μm), followed by Trios3® (15.2 ± 0.8 μm), DWIO® (27.1 ± 10.7 μm), Omnicam® (30.6 ± 3.3 μm), Emerald® (32.8 ± 10.7 μm). In the PP, CS 3600® had the best precision (17 ± 2.3 μm), followed by Trios3® (21 ± 1.9 μm), Emerald® (29.9 ± 8.9 μm), DWIO® (34.8 ± 10.8 μm), Omnicam® (43.2 ± 9.4 μm). In the FA, Trios3® had the best precision (35.6 ± 3.4 μm), followed by CS 3600® (35.7 ± 4.3 μm), Emerald® (61.5 ± 18.1 μm), Omnicam® (89.3 ± 14 μm), DWIO® (111 ± 24.8 μm). Significant differences were found between the IOSs; a significant difference in precision was found between the contexts (SC vs. PP vs. FA). CONCLUSIONS The IOSs showed significant differences between them, both in trueness and in precision. The mathematical error increased in the transition from SC to PP up to FA, both in trueness than in precision.
Collapse
Affiliation(s)
- Francesco Guido Mangano
- Department of Prevention and Communal Dentistry, Sechenov First Moscow State Medical University, Moscow, Russia.
| | - Uli Hauschild
- Department of Post-graduate Education, Faculty of Oral and Dental Medicine, J.W. Goethe University, Frankfurt, Germany
| | - Giovanni Veronesi
- Department of Medicine and Surgery, Research Center in Epidemiology and Preventive Medicine, University of Varese, Varese, Italy
| | | | - Carlo Mangano
- Department of Dental Sciences, Vita and Salute University San Raffaele, Milan, Italy
| | - Oleg Admakin
- Department of Prevention and Communal Dentistry, Sechenov First Moscow State Medical University, Moscow, Russia
| |
Collapse
|
24
|
A Novel Full-Digital Protocol (SCAN-PLAN-MAKE-DONE ®) for the Design and Fabrication of Implant-Supported Monolithic Translucent Zirconia Crowns Cemented on Customized Hybrid Abutments: A Retrospective Clinical Study on 25 Patients. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2019; 16:ijerph16030317. [PMID: 30678357 PMCID: PMC6388107 DOI: 10.3390/ijerph16030317] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2019] [Revised: 01/19/2019] [Accepted: 01/22/2019] [Indexed: 02/06/2023]
Abstract
Purpose: To present a novel, full-digital protocol for the design and fabrication of implant-supported monolithic translucent zirconia crowns cemented on customized hybrid abutments. Methods: The present retrospective clinical study was based on data from patients who had been treated with single Morse-taper connection implants (Exacone®, Leone Implants, Florence, Italy) and were prosthetically restored with monolithic translucent zirconia crowns, cemented on customized hybrid abutments. The full-digital protocol (SCAN-PLAN-MAKE-DONE®) consisted of 8 phases: (1) intraoral scan of the implant position with scanbody; (2) computer-assisted design (CAD) of the individual abutment (saved as “supplementary abutment design” in external folder) and temporary crown; (3) milling of the individual zirconia abutment and of the temporary polymethyl-methacrylate (PMMA) crown, with extraoral cementation of the zirconia abutment on the relative titanium bonding base, to generate an individual hybrid abutment; (4) clinical application of the individual hybrid abutment and cementation of the temporary PMMA crown; (5) two months later, intraoral scan of the individual hybrid abutment in position; (6) CAD of the final crown with margin line design on the previously saved “supplementary abutment design”, superimposed on the second scan of the abutment in position; (7) milling of the final crown in monolithic translucent zirconia, sintering, and characterization; and (8) clinical application of the final crown. All patients were followed for a period of 1 year. The primary outcomes of this study were the marginal adaptation of the final crown (checked clinically and radiographically), the quality of occlusal and interproximal contact points at delivery, and the aesthetic integration; the secondary outcomes were the 1-year survival and success of the implant-supported restoration. An implant-supported restoration was considered successful in the absence of any biological or prosthetic complication, during the entire follow-up period. Results: In total, 25 patients (12 males, 13 females; 26–74 years of age; mean age 51.1 ± 13.3 years) who had been restored with 40 implant-supported monolithic translucent zirconia crowns were included in this study. At delivery, the marginal adaptation was perfect for all crowns. However, there were occlusal issues (2/40 crowns: 5%), interproximal issues (1/40 crowns: 2.5%), and aesthetic issues (1/40 crowns: 2.5%). The overall incidence of issues at delivery was therefore 10% (4/40 crowns). At 1 year, one implant failed; thus the survival of the restorations was 97.5% (39/40 crowns in function). Among the surviving implant-supported restorations, three experienced complications (one loss of connection between the hybrid abutment and the implant, one decementation of the zirconia abutment, and one decementation of the zirconia crown). The success of restorations amounted to 92.4%. Conclusions: The restoration of single Morse-taper connection implants with monolithic translucent zirconia crowns cemented on customized hybrid abutments via the novel SCAN-PLAN-MAKE-DONE® full-digital protocol seems to represent a reliable treatment option. However, further studies on a larger number of patients and dealing with different prosthetic restorations (such as implant-supported fixed partial prostheses) are needed to confirm the validity of this protocol.
Collapse
|
25
|
Gul M, Arif A, Ghafoor R. Role of three-dimensional printing in periodontal regeneration and repair: Literature review. J Indian Soc Periodontol 2019; 23:504-510. [PMID: 31849394 PMCID: PMC6906903 DOI: 10.4103/jisp.jisp_46_19] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Three-dimensional (3D) printing is the process of building 3D objects by additive manufacturing approach. It is being used in endodontics, periodontology, maxillofacial surgery, prosthodontics, orthodontics, and restorative dentistry, but our review article is focused on periodontal application. A detailed literature search was done on PubMed/Medline and Google Scholar using various key terms. A total of 45 articles were included in this study. Most of the studies were in vitro, preclinical, case reports, retrospective, and prospective studies. Few clinical trials have also been done. Periodontal applications included education models, scaffolds, socket preservation, and sinus and bone augmentation and guided implant placement. It showed better alveolar ridge preservation, better regenerative capabilities, greater reduction in pocket depth and bony fill, ease of implant placement in complex cases with greater precision and reduced time with improved outcome and an important tool for education and training using simulated models.
Collapse
Affiliation(s)
- Meisha Gul
- Department of Surgery, JHS Building 1st Floor Dental Clinics, Aga Khan University Hospital, Karachi, Pakistan
| | - Aysha Arif
- Department of Surgery, JHS Building 1st Floor Dental Clinics, Aga Khan University Hospital, Karachi, Pakistan
| | - Robia Ghafoor
- Department of Surgery, JHS Building 1st Floor Dental Clinics, Aga Khan University Hospital, Karachi, Pakistan
| |
Collapse
|
26
|
Mangano F, Mangano C, Margiani B, Admakin O. Combining Intraoral and Face Scans for the Design and Fabrication of Computer-Assisted Design/Computer-Assisted Manufacturing (CAD/CAM) Polyether-Ether-Ketone (PEEK) Implant-Supported Bars for Maxillary Overdentures. SCANNING 2019; 2019:4274715. [PMID: 31531155 PMCID: PMC6724437 DOI: 10.1155/2019/4274715] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Accepted: 07/01/2019] [Indexed: 05/12/2023]
Abstract
PURPOSE To present a digital method that combines intraoral and face scanning for the computer-assisted design/computer-assisted manufacturing (CAD/CAM) fabrication of implant-supported bars for maxillary overdentures. METHODS Over a 2-year period, all patients presenting to a private dental clinic with a removable complete denture in the maxilla, seeking rehabilitation with implants, were considered for inclusion in this study. Inclusion criteria were fully edentulous maxilla, functional problems with the preexisting denture, opposing dentition, and sufficient bone volume to insert four implants. Exclusion criteria were age < 55 years, need for bone augmentation, uncompensated diabetes mellitus, immunocompromised status, radio- and/or chemotherapy, and previous treatment with oral and/or intravenous aminobisphosphonates. All patients were rehabilitated with a maxillary overdenture supported by a CAD/CAM polyether-ether-ketone (PEEK) implant-supported bar. The outcomes of the study were the passive fit/adaptation of the bar, the 1-year implant survival, and the success rates of the implant-supported overdentures. RESULTS 15 patients (6 males, 9 females; mean age 68.8 ± 4.7 years) received 60 implants and were rehabilitated with a maxillary overdenture supported by a PEEK bar, designed and milled from an intraoral digital impression. The intraoral scans were integrated with face scans, in order to design each bar with all available patient data (soft tissues, prosthesis, implants, and face) in the correct spatial position. When testing the 3D-printed resin bar, 12 bars out of 15 (80%) had a perfect passive adaptation and fit; in contrast, 3 out of 15 (20%) did not have a sufficient passive fit or adaptation. No implants were lost, for a 1-year survival of 100% (60/60 surviving implants). However, some complications (two fixtures with peri-implantitis in the same patient and two repaired overdentures in two different patients) occurred. This determined a 1-year success rate of 80% for the implant-supported overdenture. CONCLUSIONS In this study, the combination of intraoral and face scans allowed to successfully restore fully edentulous patients with maxillary overdentures supported by 4 implants and a CAD/CAM PEEK bar. Further studies are needed to confirm these outcomes.
Collapse
Affiliation(s)
- Francesco Mangano
- Lecturer, Department of Prevention and Communal Dentistry, Sechenov First Moscow State Medical University, 119992 Moscow, Russia
| | - Carlo Mangano
- Professor and Lecturer, Department of Dental Sciences, Vita and Salute University San Raffaele, 20132 Milan, Italy
| | - Bidzina Margiani
- Lecturer, Department of Prevention and Communal Dentistry, Sechenov First Moscow State Medical University, 119992 Moscow, Russia
| | - Oleg Admakin
- Professor and Head, Department of Prevention and Communal Dentistry, Sechenov First Moscow State Medical University, 119992 Moscow, Russia
| |
Collapse
|