1
|
Docampo-Vázquez C, Gragera-Alia T, Fernández-Domínguez M, Zubizarreta-Macho Á, Aragoneses-Lamas JM. Novel digital technique for measuring the volumetric healing process of free gingival grafts surrounding dental implants. FRONTIERS IN DENTAL MEDICINE 2024; 5:1372312. [PMID: 39917676 PMCID: PMC11797868 DOI: 10.3389/fdmed.2024.1372312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Accepted: 06/17/2024] [Indexed: 02/09/2025] Open
Abstract
The objective of the present study was to analyze and describe a new digital technique for analyzing the volumetric healing process of free gingival grafts in both donor and recipient locations surrounding a dental implant, as well as to compare the reliability of conventional and digital techniques for measuring the width of the free gingival graft in the recipient location throughout the healing process. Materials and methods Ten patients presenting with mucositis linked to a dental implant were included. A preoperative soft tissue width <2 mm, with probing pocket depth <5 mm, edema and inflammation and bleeding on probing was determined A digital impression was taken of both donor and recipient locations using an intraoral scan, generating a Standard Tessellation Language digital file both preoperatively (STL1) and after 1 week (STL2), 1 month (STL3), 3 months (STL4), and 6 months (STL5) of follow-up. Afterwards, the digital files (STL1-STL5) were aligned using a reverse engineering morphometric software, and Student's t-test was used to analyze changes in volume at the donor and recipient locations. Additionally, widths were measured both clinically and digitally so as to compare the reliability of these measurement techniques. The repeatability and reproducibility of both these measurement techniques were also analyzed using Gage R&R statistical analysis. Results Gage R&R found that the total variability of the digital technique was 0.6% (among the measures of each operator) and 7.6% (among operators); as variability was under 10%, the results were repeatable and reproducible. In addition, there were statistically significant differences between donor and recipient locations in healing process volume (mm3) after one week (p = 0.0110), one month (p = 0.0007), three months (p < 0.0001) and six months (p = 0.0004) of follow-up. Conclusion The digital measurement technique provided accurate, repeatable, and reproducible results when analyzing the volumetric and linear measures of the healing process in both the donor and recipient locations of a free gingival graft surrounding a dental implant, with significantly higher tissue volume in the recipient location.
Collapse
Affiliation(s)
| | | | | | - Álvaro Zubizarreta-Macho
- Faculty of Dentistry, Alfonso X El Sabio University, Madrid, Spain
- Department of Surgery, Faculty of Medicine and Dentistry, University of Salamanca, Salamanca, Spain
| | - Juan Manuel Aragoneses-Lamas
- Faculty of Dentistry, Alfonso X El Sabio University, Madrid, Spain
- Department of Dentistry, Universidad Federico Henríquez y Carvajal, Santo Domingo, Dominican Republic
| |
Collapse
|
2
|
Rodríguez Torres P, Galparsoro Catalán A, Riad Deglow E, Flores Fraile J, Alonso Pérez-Barquero J, Lobo Galindo AB, Zubizarreta-Macho Á, Hernández Montero S. Digital technique to analyze the wear of screw-retained implant supported metal-ceramic dental prostheses and natural tooth as antagonist: a pilot study. BMC Oral Health 2024; 24:177. [PMID: 38310230 PMCID: PMC10837987 DOI: 10.1186/s12903-024-03881-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Accepted: 01/10/2024] [Indexed: 02/05/2024] Open
Abstract
The aim of this study was to describe a novel digital technique to analyze the wear of screw-retained implant-supported metal-ceramic dental prostheses and natural tooth as antagonist.Materials and methods Ten patients were consecutively included to rehabilitate partial edentulism by dental implants. Both the screw-retained implant-supported metal-ceramic dental prostheses and the natural tooth as antagonist were submitted to a digital impression through an intraoral scan to generate a Standard Tessellation Language digital file preoperatively (STL1), at 3 months (STL2), and 6 months (STL3) follow-up. Afterwards, an alignment procedure of the digital files (STL1-STL3) was performed on a reverse engineering morphometric software (3D Geomagic Capture Wrap) and volume changes at the screw-retained implant-supported metal-ceramic dental prostheses and the natural tooth as antagonist were analyzed using Student's t-test. Moreover, Gage R&R statistical analysis was conducted to analyze the repeatability and reproducibility of the digital technique.Results Gage R&R showed a variability attributable to the digital technique of 3.8% (among the measures of each operator) and 4.5% (among operators) of the total variability; resulting repeatable and reproducible, since the variabilities were under 10%. In addition, statistically significant differences were shown at the wear volume (μm3) of both the natural tooth as antagonist (p < 0.0001) and the screw-retained implant-supported metal-ceramic dental prostheses between 3- and 6-months follow-up (p = 0.0002).Conclusion The novel digital measurement technique results repeatable and reproducible to analyze the wear of screw-retained implant-supported metal-ceramic dental prostheses and natural tooth as antagonist.
Collapse
Affiliation(s)
- Paulina Rodríguez Torres
- Department of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691, Madrid, Spain
| | - Agustín Galparsoro Catalán
- Department of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691, Madrid, Spain
| | - Elena Riad Deglow
- Department of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691, Madrid, Spain
| | - Javier Flores Fraile
- Department of Surgery, Faculty of Medicine, University of Salamanca, 37008, Salamanca, Spain
| | - Jorge Alonso Pérez-Barquero
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010, Valencia, Spain
| | - Ana Belén Lobo Galindo
- Department of Surgery, Faculty of Medicine, University of Salamanca, 37008, Salamanca, Spain
| | - Álvaro Zubizarreta-Macho
- Department of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691, Madrid, Spain.
- Department of Surgery, Faculty of Medicine, University of Salamanca, 37008, Salamanca, Spain.
| | - Sofía Hernández Montero
- Department of Implant Surgery, Faculty of Health Sciences, Alfonso X el Sabio University, 28691, Madrid, Spain
| |
Collapse
|
3
|
Martins JNR, Silva EJNL, Marques D, Pinto R, Francisco H, Ajuz N, Rito Pereira M, Braz Fernandes FM, Versiani MA. Characterization of four heat-treated reciprocating instruments: Design, metallurgy, mechanical performance, and irrigation flow patterns. Int Endod J 2023; 56:1412-1428. [PMID: 37698946 DOI: 10.1111/iej.13971] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 08/21/2023] [Accepted: 08/23/2023] [Indexed: 09/14/2023]
Abstract
AIM To compare the design, metallurgy, and mechanical properties of four heat-treated reciprocating instruments coupled with the evaluation of the irrigation flow using an in silico model. METHODOLOGY New EdgeOne Fire Primary, Easy-File Flex Regular 25, WaveOne Gold Primary and Reciproc Blue R25 instruments (n = 124) were initially evaluated regarding their design through stereomicroscopy, scanning electron microscopy and 3D surface scanning. In addition, energy-dispersive X-ray spectroscopy was utilized to determine their elemental composition, and differential scanning calorimetry tests to evaluate their phase transformation temperatures. Their mechanical performance was further assessed through torsional and bending tests. Using scans obtained from a real tooth and the instruments, a computational fluid dynamics assessment was conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparation. Mood's median and One-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS Reciproc Blue exhibited a superior number of blades (n = 8), whereas EdgeOne Fire had the highest overall volume (4.38 mm3 ) and surface area (32.32 mm2 ). At the 3-mm axial level, EdgeOne Fire displayed the lowest core diameter (0.13 mm), while Reciproc Blue had the highest (0.16 mm). All blades were symmetrical, and the tips of the instruments were non-active but differed from each other. The most irregular surfaces were observed in EdgeOne Fire and Easy-File Flex. All instruments were manufactured from nickel-titanium alloys and exhibited distinct phase transformation temperatures. WaveOne Gold and Reciproc Blue demonstrated the highest maximum torque values (1.87 and 1.62 N cm, respectively), while the lowest was observed on EdgeOne Fire (1.21 N cm) (p < .05). The most flexible (p < .05) were EdgeOne Fire (angle of rotation: 602.6°; maximum bending load: 251.4 g.f) and Reciproc Blue (533.2° and 235.6 g.f). There were no significant differences observed in the irrigation flow among the four domains generated by the tested instruments. CONCLUSIONS Despite observing variations in the design, phase transformation temperatures, and in the torsional and bending test outcomes among the four heat-treated reciprocating instruments, no significant differences were found in the irrigation flow pattern among the different groups in the simulated root canal preparations.
Collapse
Affiliation(s)
- Jorge N R Martins
- Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE)-Cochrane Portugal, Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Instituto de Implantologia, Lisboa, Portugal
| | - Emmanuel João Nogueira Leal Silva
- School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
- Fluminense Federal University, Rio de Janeiro, Brazil
| | - Duarte Marques
- Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE)-Cochrane Portugal, Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Instituto de Implantologia, Lisboa, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, Lisboa, Portugal
| | - Ricardo Pinto
- Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Instituto de Implantologia, Lisboa, Portugal
| | - Helena Francisco
- Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Instituto de Implantologia, Lisboa, Portugal
- Grupo de Investigação Implantologia e Regeneração Óssea (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
| | - Natasha Ajuz
- School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - Mário Rito Pereira
- Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
| | - Francisco Manuel Braz Fernandes
- CENIMAT/I3N, Department of Materials Science, NOVA School of Science and Technology, Universidade NOVA de Lisboa, Caparica, Portugal
| | | |
Collapse
|
4
|
Martins JNR, Pinto R, Silva EJNL, Simões-Carvalho M, Marques D, Martins RF, Versiani MA. 3D Surface Scanning-A Novel Protocol to Characterize Virtual Nickel-Titanium Endodontic Instruments. MATERIALS (BASEL, SWITZERLAND) 2023; 16:3636. [PMID: 37241263 PMCID: PMC10222178 DOI: 10.3390/ma16103636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 04/27/2023] [Accepted: 05/08/2023] [Indexed: 05/28/2023]
Abstract
The nickel-titanium (NiTi) instruments' geometry plays an important role in their performance and behavior. The present assessment intends to validate and test the applicability of a 3D surface scanning method using a high-resolution laboratory-based optical scanner to create reliable virtual models of NiTi instruments. Sixteen instruments were scanned using a 12-megapixel optical 3D scanner, and methodological validation was performed by comparing quantitative and qualitative measurements of specific dimensions and identifying some geometric features of the 3D models with images obtained through scanning electron microscopy. Additionally, the reproducibility of the method was assessed by calculating 2D and 3D parameters of three different instruments twice. The quality of the 3D models created by two different optical scanners and a micro-CT device was compared. The 3D surface scanning method using the high-resolution laboratory-based optical scanner allowed for the creation of reliable and precise virtual models of different NiTi instruments with discrepancies varying from 0.0002 to 0.0182 mm. The reproducibility of measurements performed with this method was high, and the acquired virtual models were adequate for use in in silico experiments, as well as for commercial or educational purposes. The quality of the 3D model obtained using the high-resolution optical scanner was superior to that acquired by micro-CT technology. The ability to superimpose virtual models of scanned instruments and apply them in Finite Element Analysis and educational purposes was also demonstrated.
Collapse
Affiliation(s)
- Jorge N. R. Martins
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), 1600-277 Lisboa, Portugal
- Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE), 1600-277 Lisboa, Portugal
| | - Ricardo Pinto
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal
| | - Emmanuel J. N. L. Silva
- Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro 21210-623, Brazil
- Department of Endodontics, Fluminense Federal University, Niterio, Rio de Janeiro 24220-900, Brazil
| | - Marco Simões-Carvalho
- Department of Endodontics, Fluminense Federal University, Niterio, Rio de Janeiro 24220-900, Brazil
| | - Duarte Marques
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), 1600-277 Lisboa, Portugal
- Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE), 1600-277 Lisboa, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, 1600-277 Lisboa, Portugal
| | - Rui F. Martins
- UNIDEMI, Department of Mechanical and Industrial Engineering, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal
| | - Marco A. Versiani
- Dental Specialty Center, Brazilian Military Police, Belo Horizonte, Minas Gerais 30350-190, Brazil
| |
Collapse
|
5
|
Faus-Matoses V, Faus-Llácer V, Moradian T, Riad Deglow E, Ruiz-Sánchez C, Hamoud-Kharrat N, Zubizarreta-Macho Á, Faus-Matoses I. Accuracy of Endodontic Access Cavities Performed Using an Augmented Reality Appliance: An In Vitro Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:11167. [PMID: 36141439 PMCID: PMC9517686 DOI: 10.3390/ijerph191811167] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 08/29/2022] [Accepted: 09/03/2022] [Indexed: 06/16/2023]
Abstract
INTRODUCTION The purpose of this study was to compare and contrast the accuracy of endodontic access cavities created using an augmented reality appliance to those performed using the conventional technique. MATERIALS AND METHODS 60 single-rooted anterior teeth were chosen for study and randomly divided between two study groups: Group A-endodontic access cavities created using an augmented reality appliance as a guide (n = 30) (AR); and Group B-endodontic access cavities performed with the manual (freehand) technique (n = 30) (MN). A 3D implant planning software was used to plan the endodontic access cavities for the AR group, with a cone-beam computed tomography (CBCT) and 3D intraoral surface scan taken preoperatively and subsequently transferred to the augmented reality device. A second CBCT scan was taken after performing the endodontic access cavities to compare the planned and performed endodontic access for accuracy. Therapeutic planning software and Student's t-test were used to analyze the cavities at the apical, coronal, and angular levels. The repeatability and reproducibility of the digital measurement technique were analyzed using Gage R&R statistical analysis. RESULTS The paired t-test found statistically significant differences between the study groups at the coronal (p = 0.0029) and apical (p = 0.0063) levels; no statistically significant differences were found between the AR and MN groups at the angular (p = 0.6596) level. CONCLUSIONS Augmented reality devices enable the safer and more accurate performance of endodontic access cavities when compared with the conventional freehand technique.
Collapse
Affiliation(s)
- Vicente Faus-Matoses
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain
| | - Vicente Faus-Llácer
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain
| | - Tanaz Moradian
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain
| | - Elena Riad Deglow
- Department of Implant Surgery, Faculty of Health Sciences, Alfonso X El Sabio University, 28691 Madrid, Spain
| | - Celia Ruiz-Sánchez
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain
| | - Nirmine Hamoud-Kharrat
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain
| | - Álvaro Zubizarreta-Macho
- Department of Implant Surgery, Faculty of Health Sciences, Alfonso X El Sabio University, 28691 Madrid, Spain
- Department of Surgery, Faculty of Medicine and Dentistry, University of Salamanca, 37008 Salamanca, Spain
| | - Ignacio Faus-Matoses
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain
| |
Collapse
|