1
|
Grady LO, Zoltick ES, Zouk H, He W, Perez E, Clarke L, Gold J, Strong A, Sahai I, Yeo J, Green RC, Karaa A, Gold NB. Long-Term Health Outcomes of Individuals With Pseudodeficiency Alleles in IDUA May Inform Newborn Screening Practices for Mucopolysaccharidosis Type I. Am J Med Genet A 2024:e63940. [PMID: 39559959 DOI: 10.1002/ajmg.a.63940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2024] [Revised: 10/18/2024] [Accepted: 11/08/2024] [Indexed: 11/20/2024]
Abstract
Mucopolysaccharidosis type I (MPS I), a lysosomal disorder caused by variants in IDUA, was added to the Recommended Uniform Screening Panel for newborn screening in 2016. Positive screening results for MPS I are commonly due to variants known as "pseudodeficiency alleles," which decrease in vitro alpha-L-iduronidase enzyme activity but are thought to provide sufficient in vivo activity. Despite the historic assumption that these variants are biologically benign, the possibility that they could give rise to complex, multigenic, or attenuated phenotypes has not been systemically evaluated in adults. We completed a retrospective matched cohort study using a hospital-based biorepository with data from 65,309 participants, we identified 1803 individuals harboring homozygous IDUA pseudodeficiency alleles. Using electronic medical records (EMR), we compared the prevalence of features of MPS I in participants with homozygous pseudodeficiency alleles to a cohort of matched control participants. We found no clinically relevant significant differences between cases and controls nor genotype-phenotype associations across four alleles. These findings provide empiric support that adults with homozygous IDUA pseudodeficiency alleles are unlikely to develop mild symptoms of disease compared with controls. This study provides a proof-of-concept model for other nonclassical disease variants related to other inherited metabolic disorders, which is necessary as newborn screening expands.
Collapse
Affiliation(s)
- Lauren O Grady
- Division of Medical Genetics and Metabolism, Massachusetts General Hospital for Children, Boston, Massachusetts, USA
| | - Emilie S Zoltick
- Department of Population Medicine, Harvard Pilgrim Health Care Institute, Boston, Massachusetts, USA
| | - Hana Zouk
- Department of Pathology, Laboratory for Molecular Medicine at Mass General Brigham Personalized Medicine, Mass General Hospital, Boston, Massachusetts, USA
| | - Wei He
- Division of General Internal Medicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Emma Perez
- Brigham and Women's Hospital, Mass General Brigham Personalized Medicine, Boston, Massachusetts, USA
| | - Lorne Clarke
- Department of Medical Genetics and the BC Children's Hospital Research Institute, University of British Columbia, Vancouver, British Columbia, Canada
| | - Jessica Gold
- Department of Pediatrics, Division of Genetics, Northwell Health, New Hyde Park, New York, USA
| | - Alanna Strong
- Division of Human Genetics, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
- Center for Applied Genomics, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA
- Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Inderneel Sahai
- Division of Medical Genetics and Metabolism, Massachusetts General Hospital for Children, Boston, Massachusetts, USA
- New England Newborn Screening Program and UMass Chen Medical School, Worcester, Massachusetts, USA
| | - Julie Yeo
- Division of Medical Genetics and Metabolism, Massachusetts General Hospital for Children, Boston, Massachusetts, USA
| | - Robert C Green
- Mass General Brigham, Boston, Massachusetts, USA
- Broad Institute, Cambridge, Massachusetts, USA
- Ariadne Labs, Boston, Massachusetts, USA
| | - Amel Karaa
- Division of Medical Genetics and Metabolism, Massachusetts General Hospital for Children, Boston, Massachusetts, USA
- Department of Pediatrics, Harvard Medical School, Boston, Massachusetts, USA
| | - Nina B Gold
- Division of Medical Genetics and Metabolism, Massachusetts General Hospital for Children, Boston, Massachusetts, USA
- Department of Pediatrics, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
2
|
Therrell BL, Padilla CD, Borrajo GJC, Khneisser I, Schielen PCJI, Knight-Madden J, Malherbe HL, Kase M. Current Status of Newborn Bloodspot Screening Worldwide 2024: A Comprehensive Review of Recent Activities (2020-2023). Int J Neonatal Screen 2024; 10:38. [PMID: 38920845 PMCID: PMC11203842 DOI: 10.3390/ijns10020038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 03/28/2024] [Accepted: 03/28/2024] [Indexed: 06/27/2024] Open
Abstract
Newborn bloodspot screening (NBS) began in the early 1960s based on the work of Dr. Robert "Bob" Guthrie in Buffalo, NY, USA. His development of a screening test for phenylketonuria on blood absorbed onto a special filter paper and transported to a remote testing laboratory began it all. Expansion of NBS to large numbers of asymptomatic congenital conditions flourishes in many settings while it has not yet been realized in others. The need for NBS as an efficient and effective public health prevention strategy that contributes to lowered morbidity and mortality wherever it is sustained is well known in the medical field but not necessarily by political policy makers. Acknowledging the value of national NBS reports published in 2007, the authors collaborated to create a worldwide NBS update in 2015. In a continuing attempt to review the progress of NBS globally, and to move towards a more harmonized and equitable screening system, we have updated our 2015 report with information available at the beginning of 2024. Reports on sub-Saharan Africa and the Caribbean, missing in 2015, have been included. Tables popular in the previous report have been updated with an eye towards harmonized comparisons. To emphasize areas needing attention globally, we have used regional tables containing similar listings of conditions screened, numbers of screening laboratories, and time at which specimen collection is recommended. Discussions are limited to bloodspot screening.
Collapse
Affiliation(s)
- Bradford L. Therrell
- Department of Pediatrics, University of Texas Health Science Center San Antonio, San Antonio, TX 78229, USA
- National Newborn Screening and Global Resource Center, Austin, TX 78759, USA
| | - Carmencita D. Padilla
- Department of Pediatrics, College of Medicine, University of the Philippines Manila, Manila 1000, Philippines;
| | - Gustavo J. C. Borrajo
- Detección de Errores Congénitos—Fundación Bioquímica Argentina, La Plata 1908, Argentina;
| | - Issam Khneisser
- Jacques LOISELET Genetic and Genomic Medical Center, Faculty of Medicine, Saint Joseph University, Beirut 1104 2020, Lebanon;
| | - Peter C. J. I. Schielen
- Office of the International Society for Neonatal Screening, Reigerskamp 273, 3607 HP Maarssen, The Netherlands;
| | - Jennifer Knight-Madden
- Caribbean Institute for Health Research—Sickle Cell Unit, The University of the West Indies, Mona, Kingston 7, Jamaica;
| | - Helen L. Malherbe
- Centre for Human Metabolomics, North-West University, Potchefstroom 2531, South Africa;
- Rare Diseases South Africa NPC, The Station Office, Bryanston, Sandton 2021, South Africa
| | - Marika Kase
- Strategic Initiatives Reproductive Health, Revvity, PL10, 10101 Turku, Finland;
| |
Collapse
|
3
|
Hirachan R, Horman A, Burke D, Heales S. Evaluation, in a highly specialised enzyme laboratory, of a digital microfluidics platform for rapid assessment of lysosomal enzyme activity in dried blood spots. JIMD Rep 2024; 65:124-131. [PMID: 38444576 PMCID: PMC10910220 DOI: 10.1002/jmd2.12413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 01/24/2024] [Accepted: 01/29/2024] [Indexed: 03/07/2024] Open
Abstract
Lysosomal storage disorders (LSDs) are predominantly enzyme deficiencies leading to substrate accumulation, causing progressive damage to multiple organs. To date, a crucial part of diagnosing LSDs is measuring enzymatic activity in leucocytes, plasma, or dried blood spots (DBS). Here, we present results from a proof-of-principle study, evaluating an innovative digital microfluidics (DMF) platform, referred to as SEEKER®, that can measure the activity of the following four lysosomal enzymes from DBS: α-L-iduronidase (IDUA) for mucopolysaccharidosis I (MPS I), acid α-glucosidase (GAA) for Pompe disease, β-glucosidase (GBA) for Gaucher disease, and α-galactosidase A (GLA) for Fabry disease. Over 900 DBS were analysed from newborns, children, and adults. DMF successfully detected known patients with MPS I, Pompe disease, and Gaucher disease, and known males with Fabry disease. This is the first demonstration of this multiplexed DMF platform for identification of patients with LSDs in a specialised diagnostic enzyme laboratory environment. We conclude that this DMF platform is relatively simple, high-throughput, and could be readily accommodated into a specialised laboratory as a first-tier test for MPS I, Pompe disease, and Gaucher disease for all patients, and Fabry disease for male patients only.
Collapse
Affiliation(s)
- Rohit Hirachan
- Chemical PathologyCamelia Botnar Laboratories, Great Ormond Street Hospital for Children NHS Foundation TrustLondonUK
| | - Alistair Horman
- Chemical PathologyCamelia Botnar Laboratories, Great Ormond Street Hospital for Children NHS Foundation TrustLondonUK
| | - Derek Burke
- Chemical PathologyCamelia Botnar Laboratories, Great Ormond Street Hospital for Children NHS Foundation TrustLondonUK
| | - Simon Heales
- Chemical PathologyCamelia Botnar Laboratories, Great Ormond Street Hospital for Children NHS Foundation TrustLondonUK
- Neurometabolic UnitNational Hospital for Neurology and NeurosurgeryLondonUK
| |
Collapse
|
4
|
Yang C, Gan X, Zeng Y, Xu Z, Xu L, Hu C, Ma H, Chai B, Hu S, Chai Y. Advanced design and applications of digital microfluidics in biomedical fields: An update of recent progress. Biosens Bioelectron 2023; 242:115723. [PMID: 37832347 DOI: 10.1016/j.bios.2023.115723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 09/11/2023] [Accepted: 09/29/2023] [Indexed: 10/15/2023]
Abstract
Significant breakthroughs have been made in digital microfluidic (DMF)-based technologies over the past decades. DMF technology has attracted great interest in bioassays depending on automatic microscale liquid manipulations and complicated multi-step processing. In this review, the recent advances of DMF platforms in the biomedical field were summarized, focusing on the integrated design and applications of the DMF system. Firstly, the electrowetting-on-dielectric principle, fabrication of DMF chips, and commercialization of the DMF system were elaborated. Then, the updated droplets and magnetic beads manipulation strategies with DMF were explored. DMF-based biomedical applications were comprehensively discussed, including automated sample preparation strategies, immunoassays, molecular diagnosis, blood processing/testing, and microbe analysis. Emerging applications such as enzyme activity assessment and DNA storage were also explored. The performance of each bioassay was compared and discussed, providing insight into the novel design and applications of the DMF technology. Finally, the advantages, challenges, and future trends of DMF systems were systematically summarized, demonstrating new perspectives on the extensive applications of DMF in basic research and commercialization.
Collapse
Affiliation(s)
- Chengbin Yang
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, China.
| | - Xiangyu Gan
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, China.
| | - Yuping Zeng
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, China.
| | - Zhourui Xu
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, China.
| | - Longqian Xu
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China.
| | - Chenxuan Hu
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China.
| | - Hanbin Ma
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China; Guangdong ACXEL Micro & Nano Tech Co., Ltd, Foshan, China.
| | - Bao Chai
- Department of Dermatology, Huazhong University of Science and Technology Union Shenzhen Hospital, Shenzhen, China; Department of Dermatology, The 6th Affiliated Hospital of Shenzhen University Health Science Center, Shenzhen, China.
| | - Siyi Hu
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China.
| | - Yujuan Chai
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, China.
| |
Collapse
|
5
|
Dorley MC, Dizikes GJ, Pickens CA, Cuthbert C, Basheeruddin K, Gulamali-Majid F, Hetterich P, Hietala A, Kelsey A, Klug T, Lesko B, Mills M, Moloney S, Neogi P, Orsini J, Singer D, Petritis K. Harmonization of Newborn Screening Results for Pompe Disease and Mucopolysaccharidosis Type I. Int J Neonatal Screen 2023; 9:ijns9010011. [PMID: 36975849 PMCID: PMC10059896 DOI: 10.3390/ijns9010011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 02/14/2023] [Accepted: 02/16/2023] [Indexed: 03/29/2023] Open
Abstract
In newborn screening, false-negative results can be disastrous, leading to disability and death, while false-positive results contribute to parental anxiety and unnecessary follow-ups. Cutoffs are set conservatively to prevent missed cases for Pompe and MPS I, resulting in increased falsepositive results and lower positive predictive values. Harmonization has been proposed as a way to minimize false-negative and false-positive results and correct for method differences, so we harmonized enzyme activities for Pompe and MPS I across laboratories and testing methods (Tandem Mass Spectrometry (MS/MS) or Digital Microfluidics (DMF)). Participating states analyzed proofof- concept calibrators, blanks, and contrived specimens and reported enzyme activities, cutoffs, and other testing parameters to Tennessee. Regression and multiples of the median were used to harmonize the data. We observed varied cutoffs and results. Six of seven MS/MS labs reported enzyme activities for one specimen for MPS I marginally above their respective cutoffs with results classified as negative, whereas all DMF labs reported this specimen's enzyme activity below their respective cutoffs with results classified as positive. Reasonable agreement in enzyme activities and cutoffs was achieved with harmonization; however, harmonization does not change how a value would be reported as this is dependent on the placement of cutoffs.
Collapse
Affiliation(s)
- M Christine Dorley
- Tennessee Department of Health, Division of Laboratory Services, Nashville, TN 37243, USA
- College of Health Sciences & Public Policy, Walden University, Minneapolis, MN 55401, USA
| | - George J Dizikes
- Tennessee Department of Health, Division of Laboratory Services, Knoxville, TN 37920, USA
| | - Charles Austin Pickens
- Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA
| | - Carla Cuthbert
- Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA
| | | | | | - Paul Hetterich
- Virginia Department of General Services, Division of Consolidated Laboratory Services, Richmond, VA 23219, USA
| | - Amy Hietala
- Minnesota Department of Health, St. Paul, MN 55155, USA
| | - Ashley Kelsey
- Michigan Department of Health & Human Services, Lansing, MI 48906, USA
| | - Tracy Klug
- Missouri State Public Health Laboratory, Jefferson City, MO 65101, USA
| | - Barbara Lesko
- Department of Pathology, Indiana University, Indianapolis, IN 46202, USA
| | - Michelle Mills
- Kansas Health and Environmental Laboratories, Topeka, KS 66620, USA
| | - Shawn Moloney
- Michigan Department of Health & Human Services, Lansing, MI 48906, USA
| | - Partha Neogi
- California Department of Public Health, Richmond, CA 94804, USA
| | - Joseph Orsini
- Wadsworth Center, New York State Department of Health, Albany, NY 12208, USA
| | | | - Konstantinos Petritis
- Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA
| |
Collapse
|
6
|
Abstract
Mucopolysaccharidosis type I (MPS I), a lysosomal storage disease caused by a deficiency of α-L-iduronidase, leads to storage of the glycosaminoglycans, dermatan sulfate and heparan sulfate. Available therapies include enzyme replacement and hematopoietic stem cell transplantation. In the last two decades, newborn screening (NBS) has focused on early identification of the disorder, allowing early intervention and avoiding irreversible manifestations. Techniques developed and optimized for MPS I NBS include tandem mass-spectrometry, digital microfluidics, and glycosaminoglycan quantification. Several pilot studies have been conducted and screening programs have been implemented worldwide. NBS for MPS I has been established in Taiwan, the United States, Brazil, Mexico, and several European countries. All these programs measure α-L-iduronidase enzyme activity in dried blood spots, although there are differences in the analytical strategies employed. Screening algorithms based on published studies are discussed. However, some limitations remain: one is the high rate of false-positive results due to frequent pseudodeficiency alleles, which has been partially solved using post-analytical tools and second-tier tests; another involves the management of infants with late-onset forms or variants of uncertain significance. Nonetheless, the risk-benefit ratio is favorable. Furthermore, long-term follow-up of patients detected by neonatal screening will improve our knowledge of the natural history of the disease and inform better management.
Collapse
Affiliation(s)
- Alberto B Burlina
- Division of Inherited Metabolic Diseases, Department of Diagnostic Services, University Hospital, Padua, Italy
| | - Vincenza Gragnaniello
- Division of Inherited Metabolic Diseases, Department of Diagnostic Services, University Hospital, Padua, Italy
| |
Collapse
|