1
|
Aellos F, Grauer JA, Harder KG, Dworan JS, Fabbri G, Cuevas PL, Yuan X, Liu B, Brunski JB, Helms JA. Dynamic analyses of a soft tissue-implant interface: Biological responses to immediate versus delayed dental implants. J Clin Periodontol 2024; 51:806-817. [PMID: 38708491 DOI: 10.1111/jcpe.13980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 02/16/2024] [Accepted: 03/10/2024] [Indexed: 05/07/2024]
Abstract
AIM To qualitatively and quantitatively evaluate the formation and maturation of peri-implant soft tissues around 'immediate' and 'delayed' implants. MATERIALS AND METHODS Miniaturized titanium implants were placed in either maxillary first molar (mxM1) fresh extraction sockets or healed mxM1 sites in mice. Peri-implant soft tissues were evaluated at multiple timepoints to assess the molecular mechanisms of attachment and the efficacy of the soft tissue as a barrier. A healthy junctional epithelium (JE) served as positive control. RESULTS No differences were observed in the rate of soft-tissue integration of immediate versus delayed implants; however, overall, mucosal integration took at least twice as long as osseointegration in this model. Qualitative assessment of Vimentin expression over the time course of soft-tissue integration indicated an initially disorganized peri-implant connective tissue envelope that gradually matured with time. Quantitative analyses showed significantly less total collagen in peri-implant connective tissues compared to connective tissue around teeth around implants. Quantitative analyses also showed a gradual increase in expression of hemidesmosomal attachment proteins in the peri-implant epithelium (PIE), which was accompanied by a significant inflammatory marker reduction. CONCLUSIONS Within the timeframe examined, quantitative analyses showed that connective tissue maturation never reached that observed around teeth. Hemidesmosomal attachment protein expression levels were also significantly reduced compared to those in an intact JE, although quantitative analyses indicated that macrophage density in the peri-implant environment was reduced over time, suggesting an improvement in PIE barrier functions. Perhaps most unexpectedly, maturation of the peri-implant soft tissues was a significantly slower process than osseointegration.
Collapse
Affiliation(s)
- Fabiana Aellos
- Department of Surgery, Stanford University School of Medicine, Stanford, California, USA
| | - Joseph A Grauer
- Department of Surgery, Stanford University School of Medicine, Stanford, California, USA
- Dr. Gerald Niznick College of Dentistry, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Kasidy G Harder
- Department of Surgery, Stanford University School of Medicine, Stanford, California, USA
- Max Rady College of Medicine, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Julia S Dworan
- Department of Surgery, Stanford University School of Medicine, Stanford, California, USA
- Department of Anatomy, Center for Anatomy and Cell Biology, Medical University of Vienna, Vienna, Austria
| | - Giacomo Fabbri
- Private Practice, Ban Mancini Fabbri Dental Clinic, Cattolica, Italy
| | - Pedro L Cuevas
- Department of Surgery, Stanford University School of Medicine, Stanford, California, USA
| | - Xue Yuan
- Department of Otolaryngology-Head and Neck Surgery, School of Medicine, Indiana University, Indianapolis, Indiana, USA
| | - Bo Liu
- Department of Surgery, Stanford University School of Medicine, Stanford, California, USA
| | - John B Brunski
- Department of Surgery, Stanford University School of Medicine, Stanford, California, USA
| | - Jill A Helms
- Department of Surgery, Stanford University School of Medicine, Stanford, California, USA
| |
Collapse
|
2
|
Chen Z, Wang Y, Sun Z, Zhao J, Lin N, Zheng Y. Clinical evaluation of closed tray impression and intraoral scanning techniques in single posterior tissue-level implant-supported crowns: A self-controlled case study. J Prosthet Dent 2024:S0022-3913(24)00379-2. [PMID: 38955602 DOI: 10.1016/j.prosdent.2024.05.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 05/23/2024] [Accepted: 05/23/2024] [Indexed: 07/04/2024]
Abstract
STATEMENT OF PROBLEM Different techniques have been used to record the locations of dental implants, yet research examining the clinical outcomes of posterior implant-supported prostheses generated by different techniques, particularly concerning their fit, is lacking. PURPOSE The purpose of this self-controlled study was to evaluate the clinical outcomes of closed tray impression making and intraoral scanning for single posterior implant-supported restorations. MATERIAL AND METHODS Eighty-two participants with a single missing posterior tooth were included. The restorations were delivered a minimum of 3 months after tissue-level implant placement. Each participant was provided with 2 screw-retained monolithic zirconia crowns, produced using 3-dimensional (3D) gel deposition from both closed tray impression making (control group) and intraoral scanning using an iTero scanner (experimental group). The recording operating time, the patient comfort assessed using a visual analog scale (VAS), and the fit of the crowns were recorded during clinical evaluation. The paired t test and Mann-Whitney U test were conducted to statistically analyze the differences between the 2 techniques (α=.05). RESULTS Seventy-six participants completed the study with a dropout rate of 7.3%. The mean ±standard deviation recording operating time of the control and experimental groups was 683 ±164 and 777 ±407 s, respectively (P<.05). The mean ±standard deviation VAS score of the control and experimental groups was 2.6 ±1.6 and 1.3 ±1.0, respectively (P<.05). The crowns in both groups showed excellent marginal fit (P>.05), but the occlusal contacts of crowns in the experimental group were significantly better (P<.05), while the interproximal contacts were significantly worse (P<.05) compared with those in the control group. In the control group, 1 crown was rated as Delta for occlusal contact and deemed clinically unacceptable. CONCLUSIONS In single posterior tissue-level implant-supported restorations, the clinical outcomes of most of the screw-retained monolithic zirconia crowns generated from closed tray impression making and intraoral scanning with the iTero system and fabricated by 3D gel deposition were acceptable. Compared with the closed tray impression technique, intraoral scanning resulted in better patient comfort and occlusal contacts but worse interproximal contacts. Efficiency was lower with intraoral scanning.
Collapse
Affiliation(s)
- Zhi Chen
- Graduate student, Graduate Prosthodontics, School/Hospital of Stomatology, Zhejiang Chinese Medical University, Hangzhou, Ningbo Dental Hospital/Ningbo Oral Health Research Institute, Ningbo, PR China
| | - Yong Wang
- Attending, School/Hospital of Stomatology, Zhejiang Chinese Medical University, Hangzhou, Department of Stomatology, Shangcheng District Jiubao Community Health Center of Hangzhou City, Hangzhou, PR China
| | - Zhe Sun
- Resident, Department of General Dentistry, School/Hospital of Stomatology, Zhejiang Chinese Medical University, Hangzhou, PR China
| | - Jing Zhao
- Attending, Department of General Dentistry, Hospital of Stomatology, Zhejiang Chinese Medical University, Hangzhou, PR China
| | - Nengjie Lin
- Resident, Department of General Dentistry, School/Hospital of Stomatology, Zhejiang Chinese Medical University, Hangzhou, PR China
| | - Yuanna Zheng
- Professor, School/Hospital of Stomatology, Zhejiang Chinese Medical University, Hangzhou, Ningbo Dental Hospital/Ningbo Oral Health Research Institute, Ningbo, PR China.
| |
Collapse
|
3
|
Joshi S, Madhav VNV, Saini RS, Gurumurthy V, Alshadidi AAF, Aldosari LIN, Okshah A, Mosaddad SA, Heboyan A. Evaluation of the effect of chemical disinfection and ultraviolet disinfection on the dimensional stability of polyether impression material: an in-vitro study. BMC Oral Health 2024; 24:458. [PMID: 38622548 PMCID: PMC11020824 DOI: 10.1186/s12903-024-04188-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Accepted: 03/26/2024] [Indexed: 04/17/2024] Open
Abstract
BACKGROUND Various methods, chemical and physical, disinfect dental impressions. Common chemicals include 1% Sodium Hypochlorite and 2% glutaraldehyde, while UV radiation is a prevalent physical method. Few studies compare their effects on dimensional stability in polyether impressions. This study aims to assess such stability using different disinfection methods. Therefore, this study was planned to evaluate the dimensional stability of polyether impression material using different disinfection methods. METHODS This in vitro study compared the effects of chemical disinfectants (1% Sodium Hypochlorite and 2% glutaraldehyde) and UV irradiation on the dimensional stability of polyether impression material. Groups A, B, C, and D, each with ten samples (N = 10), were studied. Group A was untreated (control). Group B was treated with 2% glutaraldehyde for 20 min, Group C with 1% Sodium Hypochlorite for 20 min, and Group D with UV rays for 20 min. A pilot milling machine drill was used to make four parallel holes labeled A, B, C, and D in the anterior and premolar regions from right to left. After sequential drilling, four implant analogs were positioned using a surveyor for accuracy. Ten open-tray polyether impressions were made and treated as described in the groups, followed by pouring the corresponding casts. Distortion values for each disinfection method were measured using a coordinate measuring machine capable of recording on the X- and Y-axes. RESULTS A comprehensive analysis was conducted using the one-way ANOVA test for distinct groups labeled A, B, C, and D, revealing significant differences in the mean distances for X1, X2, X4, X5, and X6 among the groups, with p-values ranging from 0.001 to 0.000. However, no significant differences were observed in X3. Notably, mean distances for the Y variables exhibited substantial differences among the groups, emphasizing parameter variations, with p-values ranging from 0.000 to 0.033. The results compared the four groups using the one-way ANOVA test, revealing statistically significant distance differences for most X and Y variables, except for X3 and Y4. Similarly, post-hoc Tukey's tests provided specific pairwise comparisons, underlining the distinctions between group C and the others in the mean and deviation distances for various variables on both the X- and Y-axes. CONCLUSIONS This study found that disinfection with 1% sodium hypochlorite or UV rays for 20 min maintained dimensional stability in polyether impressions.
Collapse
Affiliation(s)
- Snehal Joshi
- Department of Prosthodontics, SMBT Dental College and Hospital, Sangamner, 422608, Maharashtra, India
| | - V N V Madhav
- Department of Prosthodontics, YCMM & RDF's Dental College and Hospital, Ahmednagar, India
| | - Ravinder S Saini
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | | | | | | | - Abdulmajeed Okshah
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | - Seyed Ali Mosaddad
- Department of Research Analytics, Saveetha Institute of Medical and Technical Sciences, Saveetha Dental College and Hospitals, Saveetha University, Chennai, India.
- Student Research Committee, School of Dentistry, Shiraz University of Medical Sciences, Qasr-e-Dasht Street, Shiraz, Iran.
| | - Artak Heboyan
- Department of Research Analytics, Saveetha Institute of Medical and Technical Sciences, Saveetha Dental College and Hospitals, Saveetha University, Chennai, India.
- Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Str. Koryun 2, Yerevan, 0025, Armenia.
- Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
4
|
Muhsin SA, Mohammed EK, Bander K. Finite Element Analysis: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework. J Long Term Eff Med Implants 2024; 34:33-47. [PMID: 38842231 DOI: 10.1615/jlongtermeffmedimplants.2023048378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/07/2024]
Abstract
This virtual study was designed to evaluate the stress-deformation of a metal fixed partial dentures (FPDs) pontic under different loads using two different connectors. The STL file was generated for a RPD of two implant-supported restorations. The Co-Cr metal substructure was designed with two types of connector design. The pontic is connected to implant-supported crowns with square and round shape connectors. This study was designed for a cementless-retained implant-supported FPD. Finite element modeling (FEM) is used to assess the stress and deformation of the pontic within a metal substructure as the FEM might provide virtual values that could have laboratory and clinical relevance. The Co-Cr alloy mechanical properties like the Poisson ratio and modulus of elasticity were based on the parameters of the three-dimensional structure additive method. Nonparametric analyses (Mann-Whitney U test) was used. The use of square or round connectors often resulted in non-significant changes in stress, and deformation under either three or each loaded point on the occlusal surface of a pontic (P > 0.05). However, the deformation revealed distinct variations between loads of the three points compared to each loaded point (P ≤ 0.05). According to this study data, the pontic occlusal surface appears to be the same in stress and deformation under different loads depending on whether square or round connectors are used. While at the same connector designs, the pontic occlusal surface deformed significantly at three loaded points than it did at each point.
Collapse
Affiliation(s)
| | | | - Khalid Bander
- Middle Technical University, College of Health and Medical Techniques, Baghdad, Iraq
| |
Collapse
|
5
|
Albaqawi AH, Aljanakh MD, Alshammari BN, Alshammari MA, Alshammari RH, Alshammari GD, Alshammari BZ, AlShammari RA, Alturki RF, Madfa AA. Quality of Fixed Dental Prostheses and Patient Satisfaction in a Sample From Saudi Arabia. Cureus 2023; 15:e51063. [PMID: 38269215 PMCID: PMC10806941 DOI: 10.7759/cureus.51063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/25/2023] [Indexed: 01/26/2024] Open
Abstract
BACKGROUND The objective of the study was to retrospectively assess the clinical performance of dental prostheses, single crowns, and three-unit bridges to identify clinical biological and mechanical complications in the Ha'il province of Saudi Arabia. METHODS The study was conducted between March 2021 to October 2021 and included 421 patients who underwent crown and tooth-supported fixed partial denture (FPD) procedures at the Dental Polyclinics Center in the Ha'il region of Saudi Arabia from 2010-2020. The planned sampling approach was applied. Patients who underwent crown and FPD placements at the dental center within the scheduled period were identified through clinical assessments. The inclusion criteria were met by patients with three-unit FPDs and a single crown containing a natural contralateral tooth or teeth. A total of six general dentists conducted clinical exams. Patient satisfaction and technical and biological issues were the evaluation criteria for crowns and FPDs. The frequency and percentage of the various characteristics employed in the current investigation were ascertained using cross-tabulation. The Chi-square test was employed to assess the associations between categorical variables, with p-values ≤ 0.05 considered significant. Results: Marginal integrity was recorded in 332 participants (78.9%), which was satisfactory for the majority of the restoration. The acceptance morphology was present in 252 (59.9%) restorations. The highest rate of the restorations 274 (66.2%) had satisfactory color. In 86 cases (20.4%), there was visible periodontal depth of at least 5 mm. Three hundred and six (72.7%) of the fixed restorations had gingival bleeding connected to them, and 96 (22.8%) teeth had periapical lesions. A total of 311 patients (73.9%) reported they were satisfied with their fixed restorations. CONCLUSIONS The technical and biological complications noted in the current study were not higher compared with other studies of crowns and fixed dental prostheses. The majority of patients were satisfied with the restoration.
Collapse
Affiliation(s)
- Ahmed H Albaqawi
- Restorative Dental Science, College of Dentistry, University of Ha'il, Ha'il, SAU
| | - Mohammad D Aljanakh
- Restorative Dental Science, College of Dentistry, University of Ha'il, Ha'il, SAU
| | | | | | | | | | | | | | | | - Ahmed A Madfa
- Restorative Dental Science, College of Dentistry, University of Ha'il, Ha'il, SAU
| |
Collapse
|
6
|
Chankhore P, Khubchandani SR, Reche A, Paul P. Prosthetic Design Factors Influencing Peri-Implant Disease: A Comprehensive Review. Cureus 2023; 15:e48737. [PMID: 38699657 PMCID: PMC11065393 DOI: 10.7759/cureus.48737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2023] [Accepted: 11/13/2023] [Indexed: 05/05/2024] Open
Abstract
Peri-implant disease, encompassing peri-implant mucositis and peri-implantitis, presents a growing challenge in implant dentistry. This comprehensive review explores the intricate interplay between prosthetic design factors and the development of peri-implant disease. By analyzing the impact of prosthetic components on microbial colonization, mechanical stress, and soft tissue health, the review highlights their crucial role in disease prevention and management. Additionally, it emphasizes the significance of maintenance protocols, prosthetic adjustments, and patient education in ensuring favorable long-term outcomes. The review underscores the potential for future advancements in prosthetic design, including innovative materials and digital technologies, and stresses the importance of interdisciplinary collaboration in optimizing patient care. Overall, the review underscores the critical role of prosthetic design in addressing the complexities of peri-implant disease, offering insights for clinicians and researchers to enhance the success and longevity of implant-supported restorations.
Collapse
Affiliation(s)
- Pallavi Chankhore
- Public Health Dentistry, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Sheetal R Khubchandani
- Prosthodontist and Implantologist, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Amit Reche
- Public Health Dentistry, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| | - Priyanka Paul
- Public Health Dentistry, Sharad Pawar Dental College and Hospital, Datta Meghe Institute of Higher Education and Research, Wardha, IND
| |
Collapse
|
7
|
Lops D, Romeo E, Mensi M, Troiano G, Zhurakivska K, Del Fabbro M, Palazzolo A. CAD/CAM Abutments in the Esthetic Zone: A Systematic Review and Meta-Analysis of Soft Tissue Stability. J Clin Med 2023; 12:jcm12113847. [PMID: 37298041 DOI: 10.3390/jcm12113847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 05/25/2023] [Accepted: 06/02/2023] [Indexed: 06/12/2023] Open
Abstract
Computer-aided design and computer-aided manufacturing customized abutments are increasingly used in everyday clinical practice. Nevertheless, solid scientific evidence is currently lacking regarding their potential advantages in terms of soft tissue stability. The main aim of this systematic review and meta-analysis was to compare the soft tissue outcomes of prefabricated versus customized (CAD/CAM) abutments. The present review was registered with PROSPERO (CRD42020161875) and the protocol was developed according to the PRISMA statement. An electronic search was performed on three databases (PubMed, Embase and Cochrane Central) up to May 2023. Data extraction was followed by qualitative and quantitative analysis of the included studies. Three randomized controlled clinical trials and three controlled clinical trials (number of patients = 230; number of dental implants = 230) with a follow-up of between 12 and 36 months were included. No significant differences were observed between prefabricated versus customized (CAD/CAM) abutments regarding midfacial mucosal recession, interproximal papillae and pink aesthetic score (PES) after 12 months. Conclusion: The potential benefits of CAD/CAM abutments on soft tissues should be better clarified in future investigations. The usage of customized CAD/CAM abutments in everyday clinical practice should be based on a careful case-by-case evaluation (CRD42020161875).
Collapse
Affiliation(s)
- Diego Lops
- Department of Biomedical, Surgical and Dental Sciences, Dental Clinic, School of Dentistry, University of Milan, 20122 Milan, Italy
| | - Eugenio Romeo
- Department of Biomedical, Surgical and Dental Sciences, Dental Clinic, School of Dentistry, University of Milan, 20122 Milan, Italy
| | - Magda Mensi
- Department of Surgical Specialties, Radiological Science and Public Health, University of Brescia, 25123 Brescia, Italy
| | - Giuseppe Troiano
- Department of Clinical and Experimental Medicine, University of Foggia, 71122 Foggia, Italy
| | - Khrystyna Zhurakivska
- Department of Clinical and Experimental Medicine, University of Foggia, 71122 Foggia, Italy
| | - Massimo Del Fabbro
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy
| | - Antonino Palazzolo
- Department of Biomedical, Surgical and Dental Sciences, Dental Clinic, School of Dentistry, University of Milan, 20122 Milan, Italy
| |
Collapse
|
8
|
Ling Z, Jin J, Wang S, Shen X, He F. Performance of indirect technique in peri-implant soft tissue contour duplication in the anterior maxilla: A clinical pilot study. Clin Implant Dent Relat Res 2023. [PMID: 37186153 DOI: 10.1111/cid.13211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 04/08/2023] [Accepted: 04/16/2023] [Indexed: 05/17/2023]
Abstract
OBJECTIVE To evaluate the performance of the indirect technique in peri-implant soft tissue contour duplication after the delivery procedure in the anterior maxilla. MATERIALS AND METHODS Patients with single implant-supported fixed restorations in the anterior maxilla were recruited. For the impression procedure, an intraoral scan was acquired by both the direct and the indirect techniques. For the delivery procedure, implants were randomly allocated into one of the two groups according to the approaches of digital impression preceding definite crown fabrication (A-direct technique; B-indirect technique) and were scanned again after the definite crown delivery. The stereolithography files were superimposed to analyze changes in peri-implant soft tissue contour after the delivery procedure. The main outcomes were dimensional deviations of peri-implant mucosa, and the secondary outcome was differences in the pink esthetic score (PES). RESULTS A total of 20 implants that underwent the complete workflow were included. After the delivery procedure, significant deviations in palatal tissue thickness between the provisional and definite crowns were observed in Group A but these were absent in Group B. Additionally, deviations in labial thickness (0.27 ± 0.12 mm vs. 0.08 ± 0.09 mm) and palatal thickness (0.17 ± 0.15 mm vs. 0.03 ± 0.08 mm), and labial volume of soft tissue (1.87 ± 0.94 mm3 vs. 0.75 ± 0.74 mm3 ) in Group A were significantly higher than those in Group B. No significant differences in PES were found. CONCLUSION The indirect technique of scanning the provisional crown can more accurately duplicate the peri-implant soft tissue contour than the direct technique, resulting in a smaller deviation of the soft tissue in the delivery procedure.
Collapse
Affiliation(s)
- Zhaoting Ling
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Disease of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, China
| | - Jiali Jin
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Disease of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, China
- School/Hospital of Stomatology, Zhejiang Chinese Medical University, Hangzhou, China
| | - Siyuan Wang
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Disease of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, China
| | - Xiaoting Shen
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Disease of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, China
| | - Fuming He
- Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Disease of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, China
| |
Collapse
|
9
|
Saravi B, Flohr A, Patzelt SB, Spies BC, Hazard D, Kohal RJ. Fatigue and Fracture Resistance Testing of Polyether Ether Ketone (PEEK) Implant Abutments in an Ex Vivo Chewing Simulator Model. MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15196927. [PMID: 36234281 PMCID: PMC9573129 DOI: 10.3390/ma15196927] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 09/26/2022] [Accepted: 10/01/2022] [Indexed: 05/26/2023]
Abstract
Polyether ether ketone (PEEK) has been introduced into implant dentistry as a viable alternative to current implant abutment materials. However, data on its physico-mechanical properties are still scarce. The present study sought to shed light on this topic utilizing an ex vivo chewing simulator model. A total of 48 titanium two-piece implants were allocated into three groups (n = 16 per group): (1) implants with PEEK abutments and an internal butt-joint connection (PBJ), (2) implants with PEEK abutments and an internal conical implant-abutment connection (PC), and (3) implants with zirconia abutments and an internal butt-joint connection (ZA). All abutments were restored with a non-precious metal alloy crown mimicking the upper right central incisor. A dynamic chewing simulation of half (n = 8) of the specimens per group was performed with 5 × 106 cycles and a load of 49 N at a frequency of 1.7 Hz with thermocycling between 5 and 55 °C. The other eight specimens served as unloaded controls. Surface roughness, implant-abutment connection microgaps (IACMs), and the titanium base-abutment interface microgaps (TAIMs) in the loaded groups were evaluated. Finally, a quasi-static loading test was performed in a universal testing machine with all samples to evaluate fracture resistance. Overall, 23 samples survived the artificial chewing process. One abutment screw fracture was observed in the PC group. The ZA group showed higher surface roughness values than PEEK abutments. Furthermore, ZA revealed lower TAIM values compared to PEEK abutments. Similarly, ZA was associated with lower IACM values compared to PBJ. Fracture loads/bending moments were 1018 N/704 N cm for PBJ, 966 N/676 N cm for PC, and 738 N/508 N cm for ZA, with no significant differences compared to the unloaded references. Artificial loading did not significantly affect fracture resistance of the examined materials. PEEK abutments were associated with better load-bearing properties than zirconia abutments, although they showed higher microgap values. PEEK abutments could, therefore, be feasible alternatives to zirconia abutments based on the present ex vivo findings resembling 20 years of clinical service.
Collapse
Affiliation(s)
- Babak Saravi
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine, University of Freiburg, Medical Center—University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany
| | - Anselm Flohr
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center—University of Freiburg, Center for Dental Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany
| | - Sebastian B. Patzelt
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center—University of Freiburg, Center for Dental Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany
- Private Dental Clinic, Am Dorfplatz 3, 78658 Zimmern ob Rottweil, Germany
| | - Benedikt C. Spies
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center—University of Freiburg, Center for Dental Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany
| | - Derek Hazard
- Institute of Medical Biometry and Medical Statistics, Faculty of Medicine, Medical Center—University of Freiburg, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany
| | - Ralf J. Kohal
- Department of Prosthetic Dentistry, Faculty of Medicine, Medical Center—University of Freiburg, Center for Dental Medicine, University of Freiburg, Hugstetter Street 55, 79106 Freiburg, Germany
| |
Collapse
|
10
|
Fractal Dimension as a Tool for Assessment of Dental Implant Stability—A Scoping Review. J Clin Med 2022; 11:jcm11144051. [PMID: 35887815 PMCID: PMC9319468 DOI: 10.3390/jcm11144051] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 07/11/2022] [Accepted: 07/12/2022] [Indexed: 02/05/2023] Open
Abstract
A lot of modalities for assessing implant stability are available for clinicians, but they fail to assess trabecular changes as they are solely dependent on the operator’s skills. The use of Fractal Dimension (FD) has evolved to be used as a measure for trabecular changes depicting implant stability before and after implant placement. The objective of this systematic review was to qualitatively analyse the available scientific literature describing the use of FD as a tool to measure implant stability on the basis of trabecular changes. An electronic search in PubMed, Web of Science and Scopus was carried out using relevant keywords, such as: fractal dimension; fractal analysis; dental implants; implant stability; osseointegration, etc. Studies reporting the use of FD as a tool to measure implant stability were included and subjected to qualitative analysis using ROBINS-I and Cochrane risk of bias assessment criteria. Fourteen studies were included in this review. Results showed that FD was found to be used solely as a measure of implant stability in seven studies, out of which six studies showed an increment in FD values. The majority of studies concluded with a statistical correlation between FD and respective other assessment methods used. FD may not serve as a sole indicator of implant stability; however, it can be used as an adjunct to conventional methods along with additional fractal factors.
Collapse
|
11
|
Galindo-Moreno P, Concha-Jeronimo A, Lopez-Chaichio L, Rodriguez-Alvarez R, Sanchez-Fernandez E, Padial-Molina M. Marginal Bone Loss around Implants with Internal Hexagonal and Internal Conical Connections: A 12-Month Randomized Pilot Study. J Clin Med 2021; 10:jcm10225427. [PMID: 34830709 PMCID: PMC8621760 DOI: 10.3390/jcm10225427] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 11/12/2021] [Accepted: 11/18/2021] [Indexed: 02/07/2023] Open
Abstract
The aim of this study was to analyze the differences in terms of the marginal bone level (MBL) around implants with either an internal conical or an internal hexagonal implant–prosthesis connection. A randomized clinical trial included patients in need of a single implant-supported restoration. The implant–prosthesis connection was either internal conical or internal hexagonal while maintaining the same type of implant macro- and microarchitecture. Clinical and radiographical variables were registered up to 12 months of follow-up, including MBL. A total of 30 patients were included in the study. The main outcome variable, MBL 12 months after prosthesis delivery, was statistically different in both groups: −0.25 (0.12) vs. −0.70 (0.43) (conical vs. hexagonal; p = 0.033). Differences were also observed at the 3- and 6-month follow-up visits as well as for the MBL change from prosthesis delivery to the 12-month follow-up (−0.15 (0.13) vs. −0.56 (0.44); conical vs. hexagonal; p = 0.023). Correlations between MBL around the implants and radiographic measurements on the adjacent teeth, buccal bone to implant, tissue thickness or keratinized tissue were not significant neither globally nor when analyzed independently by group. In view of such results, it can be concluded that single-unit restorations with internal hexagonal-connection implants induce higher marginal bone loss after 12 months of follow-up from prosthesis delivery than internal conical-connection implants.
Collapse
Affiliation(s)
- Pablo Galindo-Moreno
- Department of Oral Surgery and Implant Dentistry, School of Dentistry, University of Granada, 18071 Granada, Spain; (E.S.-F.); (M.P.-M.)
- Research Group in Oral Biology and Regeneration (CTS-1028), Junta de Andalucia, 18071 Granada, Spain;
- Correspondence:
| | - Ada Concha-Jeronimo
- PhD Program in Clinical Medicine and Public Health, University of Granada, 18016 Granada, Spain; (A.C.-J.); (L.L.-C.)
| | - Lucia Lopez-Chaichio
- PhD Program in Clinical Medicine and Public Health, University of Granada, 18016 Granada, Spain; (A.C.-J.); (L.L.-C.)
| | - Roque Rodriguez-Alvarez
- Research Group in Oral Biology and Regeneration (CTS-1028), Junta de Andalucia, 18071 Granada, Spain;
- PhD Program in Clinical Medicine and Public Health, University of Granada, 18016 Granada, Spain; (A.C.-J.); (L.L.-C.)
| | - Elena Sanchez-Fernandez
- Department of Oral Surgery and Implant Dentistry, School of Dentistry, University of Granada, 18071 Granada, Spain; (E.S.-F.); (M.P.-M.)
- Research Group in Oral Biology and Regeneration (CTS-1028), Junta de Andalucia, 18071 Granada, Spain;
| | - Miguel Padial-Molina
- Department of Oral Surgery and Implant Dentistry, School of Dentistry, University of Granada, 18071 Granada, Spain; (E.S.-F.); (M.P.-M.)
- Research Group in Oral Biology and Regeneration (CTS-1028), Junta de Andalucia, 18071 Granada, Spain;
- PhD Program in Clinical Medicine and Public Health, University of Granada, 18016 Granada, Spain; (A.C.-J.); (L.L.-C.)
| |
Collapse
|
12
|
Patient-Centered Treatment Outcomes with Full-Arch PEEK Rehabilitation Supported on Four Immediate or Conventionally Loaded Implants. A Randomized Clinical Trial. J Clin Med 2021; 10:jcm10194589. [PMID: 34640607 PMCID: PMC8509672 DOI: 10.3390/jcm10194589] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2021] [Revised: 09/25/2021] [Accepted: 09/30/2021] [Indexed: 12/14/2022] Open
Abstract
This study aims to assess the treatment outcomes (functional and subjective) of full-arch fixed hybrid rehabilitations made of PEEK (poly-ether-ether-ketone) with milled crowns of nano-filled composite (NFC) supported on four to six implants. In this randomized clinical trial, 34 edentate patients in the upper and/or the lower jaws were treated with the fixed hybrid dentures. In 16 patients (47.1% of the sample), the implants were loaded immediately (IL) by means of a provisional fixed rehabilitation made of PMMA (polymethylmethacrylate) screwed on Multi-Unit (MU) abutments connected after emplacement of the implant; however, in the counterparts (n = 18) these MU abutments were covered by healing caps and were left unloaded during two months (conventional loading protocol—CL), when all patients received a fixed hybrid PEEK-NFC rehabilitation on the upper and/or the lower jaw. Treatment outcomes were assessed 12 months after prostheses delivery. Functional outcomes were calculated according to masticatory performance, estimated by mixing ability tests of two colored chewing gums after ten chewing strokes, by the occlusal force/area recorded by pressure-sensitive sheets, and by electromyography of masseters and temporal muscles at maximum biteforce. The subjective outcomes of the treatment were assessed using both the oral satisfaction scale (visual analog scale) and the Spanish version of the Oral Health Impact Profile (OHIP-20). The findings of the present study showed that treatment with fixed PEEK-NFC hybrid prostheses significantly improved the masticatory performance, bite force, occlusal pattern, quality of life, and satisfaction, with the IL group being those with significantly higher occlusal bite forces and greater satisfaction in comparison with CL group. It should be concluded that PEEK-NFC hybrid prostheses can improve several patient-centered outcomes and that loading protocol significantly affects the patient’s self-rated satisfaction.
Collapse
|