1
|
Lee SM, Hwang H, Shin MH, Yi JW. One-Year Clinical Experience of Single-Port and Multi-Port Robotic Thyroid Surgery in a Single Institution. J Clin Med 2024; 13:5486. [PMID: 39336973 PMCID: PMC11432036 DOI: 10.3390/jcm13185486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2024] [Revised: 09/10/2024] [Accepted: 09/13/2024] [Indexed: 09/30/2024] Open
Abstract
Background: With the advent of da Vinci SP, surgical methods using da Vinci SP are becoming popular in thyroid surgery. The authors previously reported on a new surgical method called the single-port robotic areolar (SPRA) approach, which evolved from the previous bilateral axillary breast approach (BABA). This paper reports a comparative analysis of SPRA and BABA over one year. Methods: The data on SPRA and BABA thyroid surgery performed at the authors' hospital from December 2022 to December 2023 were analyzed. Results: 111 SPRA and 159 BABA surgeries were performed. SPRA was performed overwhelmingly on women (1 man vs. 110 women), and the body mass index (BMI) was lower in SPRA patients (23.63 ± 3.49 vs. 25.71 ± 4.39, p < 0.001). The proportion of total thyroidectomy was significantly higher in BABA patients, and a modified radical neck dissection (MRND) was only performed using the BABA method. The time for flap formation before robot docking was significantly shorter in SPRA patients (12.08 ± 3.99 vs. 18.34 ± 5.84 min, p < 0.001). Postoperative drain amount was also significantly lower in SPRA patients (53.87 ± 35.45 vs. 81.74 ± 30.26 mL, p < 0.001). Hospital stay after surgery was significantly shorter with SPRA (3.04 ± 0.48 vs. 3.36 ± 0.73 days, p < 0.001). Thyroglobulin levels after a total thyroidectomy (0.06 ± 0.13 vs. 0.45 ± 0.78, p = 0.002) and stimulated Tg level before the RAI (1.03 ± 0.74 vs. 5.01 ± 13.63, p = 0.046) were significantly lower in the SPRA group. No significant differences were observed between the two groups according to the postoperative complications, including vocal cord palsy and hypoparathyroidism. Conclusions: Based on the authors' experience, SPRA is a less invasive robot thyroid surgery method than BABA.
Collapse
Affiliation(s)
- Sun Min Lee
- Department of Surgery, Inha University Hospital & College of Medicine, Incheon 22332, Republic of Korea; (S.M.L.); (H.H.); (M.H.S.)
- Robot Surgery Center, Inha University Hospital, Incheon 22332, Republic of Korea
| | - Hilal Hwang
- Department of Surgery, Inha University Hospital & College of Medicine, Incheon 22332, Republic of Korea; (S.M.L.); (H.H.); (M.H.S.)
| | - Myung Ho Shin
- Department of Surgery, Inha University Hospital & College of Medicine, Incheon 22332, Republic of Korea; (S.M.L.); (H.H.); (M.H.S.)
| | - Jin Wook Yi
- Department of Surgery, Inha University Hospital & College of Medicine, Incheon 22332, Republic of Korea; (S.M.L.); (H.H.); (M.H.S.)
- Robot Surgery Center, Inha University Hospital, Incheon 22332, Republic of Korea
| |
Collapse
|
2
|
Xu P, Fang Q, Mai J, Zhao Z, Cao F, Wu D, Liu X. Gasless robot-assisted transaxillary hemithyroidectomy (RATH): learning curve and complications. BMC Surg 2024; 24:78. [PMID: 38431572 PMCID: PMC10909294 DOI: 10.1186/s12893-024-02366-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Accepted: 02/21/2024] [Indexed: 03/05/2024] Open
Abstract
PURPOSE Gasless robot-assisted transaxillary hemithyroidectomy (RATH) is regarded as an alternative surgical option for thyroid operations. However, the associated steep learning curve is a clinical concern. This study evaluated the learning curve of RATH for surgeons without experience of endoscopic surgery and the early surgical outcomes of RATH. METHODS We conducted a retrospective study of patients who underwent gasless RATH and conventional hemithyroidectomy (CH) at Sun Yat-sen University Cancer Center, Guangzhou, China, from June 2021 to August 2022. The learning curve and early surgical outcomes of gasless RATH were evaluated. And the early surgical outcomes of gasless RATH were compared to CH. RESULTS In total, 105 patients who underwent gasless RATH and 104 patients who underwent CH were matched and assessed. The cumulative sum techniques (CUSUM) analysis showed that the peak point of gasless RATH operative time occurred at the 31st case. No clear single peak was identified in the CUSUM plot for drainage amount and blood loss. No significant difference in perioperative complications was observed between these two groups. Moreover, the number of postoperative patients who got sense of thyroid area traction were fewer in the gasless RATH group (n = 11, 10.5%) than in the CH group (n = 32, 30.8%). CONCLUSION Gasless RATH can be considered as an alternative approach to the conventional open procedure, as it is an easy remote access technique, with shorter learning curves and certain advantage such as less sense of thyroid area traction.
Collapse
Affiliation(s)
- Pengfei Xu
- Department of Head and Neck Surgery, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng East Road, Guangzhou, Guangdong, 510060, P. R. China
| | - Qi Fang
- Department of Head and Neck Surgery, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng East Road, Guangzhou, Guangdong, 510060, P. R. China
| | - Junhao Mai
- Department of Breast and Thyroid Surgery, Guangzhou Panyu Central Hospital, 8 Fuyu East Road, Guangzhou, Guangdong, 511400, P.R. China
| | - Zheng Zhao
- Department of Head and Neck Surgery, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng East Road, Guangzhou, Guangdong, 510060, P. R. China
| | - Fei Cao
- Department of Head and Neck Surgery, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng East Road, Guangzhou, Guangdong, 510060, P. R. China
| | - Di Wu
- Department of Head and Neck Surgery, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng East Road, Guangzhou, Guangdong, 510060, P. R. China.
| | - Xuekui Liu
- Department of Head and Neck Surgery, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, 651 Dongfeng East Road, Guangzhou, Guangdong, 510060, P. R. China.
| |
Collapse
|
3
|
Pai SN, Jeyaraman M, Jeyaraman N, Nallakumarasamy A, Yadav S. In the Hands of a Robot, From the Operating Room to the Courtroom: The Medicolegal Considerations of Robotic Surgery. Cureus 2023; 15:e43634. [PMID: 37719624 PMCID: PMC10504870 DOI: 10.7759/cureus.43634] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/17/2023] [Indexed: 09/19/2023] Open
Abstract
Robotic surgery has rapidly evolved as a groundbreaking field in medicine, revolutionizing surgical practices across various specialties. Despite its numerous benefits, the adoption of robotic surgery faces significant medicolegal challenges. This article delves into the underexplored legal implications of robotic surgery and identifies three distinct medicolegal problems. First, the lack of standardized training and credentialing for robotic surgery poses potential risks to patient safety and surgeon competence. Second, informed consent processes require additional considerations to ensure patients are fully aware of the technology's capabilities and potential risks. Finally, the issue of legal liability becomes complex due to the involvement of multiple stakeholders in the functioning of robotic systems. The article highlights the need for comprehensive guidelines, regulations, and training programs to navigate the medicolegal aspects of robotic surgery effectively, thereby unlocking its full potential for the future..
Collapse
Affiliation(s)
- Satvik N Pai
- Orthopaedic Surgery, Hospital for Orthopedics, Sports Medicine, Arthritis, and Trauma (HOSMAT) Hospital, Bangalore, IND
| | - Madhan Jeyaraman
- Orthopaedics, ACS Medical College and Hospital, Dr. MGR Educational and Research Institute, Chennai, IND
| | - Naveen Jeyaraman
- Orthopaedics, ACS Medical College and Hospital, Dr. MGR Educational and Research Institute, Chennai, IND
| | - Arulkumar Nallakumarasamy
- Orthopaedics, ACS Medical College and Hospital, Dr. MGR Educational and Research Institute, Chennai, IND
| | - Sankalp Yadav
- Medicine, Shri Madan Lal Khurana Chest Clinic, New Delhi, IND
| |
Collapse
|
4
|
Ludwig B, Ludwig M, Dziekiewicz A, Mikuła A, Cisek J, Biernat S, Kaliszewski K. Modern Surgical Techniques of Thyroidectomy and Advances in the Prevention and Treatment of Perioperative Complications. Cancers (Basel) 2023; 15:cancers15112931. [PMID: 37296896 DOI: 10.3390/cancers15112931] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Revised: 05/16/2023] [Accepted: 05/23/2023] [Indexed: 06/12/2023] Open
Abstract
Thyroid cancer is the most common cancer of the endocrine system, and, in recent years, there has been a phenomenon of overdiagnosis followed by subsequent overtreatment. This results in an increasing number of thyroidectomy complications being faced in clinical practice. In this paper, we present the current state of knowledge and the latest findings in the fields of modern surgical techniques, thermal ablation, the identification and assessment of parathyroid function, recurrent laryngeal nerve monitoring and treatment and perioperative bleeding. We reviewed 485 papers, from which we selected 125 papers that are the most relevant. The main merit of this article is its comprehensive view of the subject under discussion-both general, concerning the selection of the appropriate method of surgery, and particular, concerning the selection of the appropriate method of prevention or treatment of selected perioperative complications.
Collapse
Affiliation(s)
- Bartłomiej Ludwig
- Department of General, Minimally Invasive and Endocrine Surgery, Wroclaw Medical University, Borowska Street 213, 50-556 Wroclaw, Poland
| | - Maksymilian Ludwig
- Department of General, Minimally Invasive and Endocrine Surgery, Wroclaw Medical University, Borowska Street 213, 50-556 Wroclaw, Poland
| | - Anna Dziekiewicz
- Department of General, Minimally Invasive and Endocrine Surgery, Wroclaw Medical University, Borowska Street 213, 50-556 Wroclaw, Poland
| | - Agnieszka Mikuła
- Department of General, Minimally Invasive and Endocrine Surgery, Wroclaw Medical University, Borowska Street 213, 50-556 Wroclaw, Poland
| | - Jakub Cisek
- Department of General, Minimally Invasive and Endocrine Surgery, Wroclaw Medical University, Borowska Street 213, 50-556 Wroclaw, Poland
| | - Szymon Biernat
- Department of General, Minimally Invasive and Endocrine Surgery, Wroclaw Medical University, Borowska Street 213, 50-556 Wroclaw, Poland
| | - Krzysztof Kaliszewski
- Department of General, Minimally Invasive and Endocrine Surgery, Wroclaw Medical University, Borowska Street 213, 50-556 Wroclaw, Poland
| |
Collapse
|