Möllmann H, Linke A, Nombela-Franco L, Sluka M, Francisco Oteo Dominguez J, Montorfano M, Kim WK, Arnold M, Vasa-Nicotera M, Fichtlscherer S, Conradi L, Camuglia A, Bedogni F, Kohli K, Manoharan G. Valve Hemodynamics by Valve Size and 1-Year Survival Following Implantation of the Portico Valve in the Multicenter CONFIDENCE Registry. STRUCTURAL HEART : THE JOURNAL OF THE HEART TEAM 2024; 8:100226. [PMID: 38283573 PMCID: PMC10818152 DOI: 10.1016/j.shj.2023.100226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 08/09/2023] [Accepted: 08/31/2023] [Indexed: 01/30/2024]
Abstract
Background The CONtrolled delivery For ImproveD outcomEs with cliNiCal Evidence registry was initiated to characterize the clinical safety and device performance from experienced transcatheter aortic valve implantation (TAVI) centers in Europe and Australia that use the Portico valve to treat patients with severe aortic stenosis. We herein report for the first time the valve performance at 30-day across all implanted valve sizes and the 1-year survival from this registry. Methods This was a prospective, multicenter, single-arm observational clinical investigation of patients clinically indicated for implantation of a Portico valve in experienced TAVI centers. Patients were treated with a commercially available valve (size 23, 25, 27, or 29 mm) using either the first-generation delivery system (DS) (n = 501) or the second-generation (FlexNav) DS (n = 500). Adverse events were adjudicated by an independent clinical events committee according to Valve Academic Research Consortium-2 criteria. Echocardiographic outcomes were assessed at 30 days by an independent core laboratory, and a survival check was performed at 1 year. Results We enrolled 1001 patients (82.0 years, 62.5% female, 63.7% New York Heart Association functional class III/IV at baseline) from 27 clinical sites in 8 countries across Europe and one site in Australia. Implantation of a single valve was successful in 97.5% of subjects. Valve hemodynamics at 30 days were substantially improved relative to baseline, with large aortic valve areas and low mean gradients across all implanted valve sizes (aortic valve areas were 1.7 ± 0.4, 1.7 ± 0.5, 1.8 ± 0.5, and 2.0 ± 0.5 cm2, and mean gradients were 7.0 ± 2.7, 7.5 ± 4.7, 7.3 ± 3.3, and 6.4 ± 3.3 mmHg for 23, 25, 27, and 29 mm valve sizes, respectively). Across all implanted valve sizes, most patients (77.1%) had no patient-prosthesis mismatch. Death from any cause within 1 year occurred in 13.7% of the patients in the first-generation DS group as compared with 11.0% in the second-generation DS group (p = 0.2). Conclusions The Portico valve demonstrated excellent hemodynamic performance across all valve sizes in a large cohort of subjects implanted in experienced TAVI centers. One-year survival rates were favorable when using both the first-generation and second-generation (FlexNav) DSs in this high-risk cohort. ClinicalTrialsgov Identifier NCT03752866.
Collapse
Affiliation(s)
- Helge Möllmann
- Department of Cardiology, St. Johannes Hospital, Dortmund, Germany
| | - Axel Linke
- Department of Internal Medicine/Cardiology, University Hospital of the Technical University of Dresden, Heart Center Dresden, Dresden, Germany
| | - Luis Nombela-Franco
- Cardiovascular Institute, Hospital Clinico San Carlos, IdISSC, Madrid, Spain
| | - Martin Sluka
- Department of Medicine-Cardiology, University Hospital Olomouc, Olomouc, Czech Republic
| | | | - Matteo Montorfano
- Interventional Cardiology Unit IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Won-Keun Kim
- Kerckhoff Heart and Thorax Centre, Bad Nauheim, Germany
| | - Martin Arnold
- Department of Cardiology, Friedrich-Alexander-Universität Erlangen Nuremberg, Erlangen, Germany
| | - Mariuca Vasa-Nicotera
- Department of Cardiology, University Hospital of the Johann Wolfgang Goethe University Frankfurt, Frankfurt, Germany
| | - Stephan Fichtlscherer
- Department of Cardiology, University Hospital of the Johann Wolfgang Goethe University Frankfurt, Frankfurt, Germany
| | - Lenard Conradi
- Department of Cardiovascular Surgery, University Heart and Vascular Center, Hamburg, Germany
| | - Anthony Camuglia
- University of Queensland, Brisbane, Australia
- The Wesley Hospital, Brisbane, Australia
| | | | - Keshav Kohli
- Abbott Laboratories, Santa Clara, California, USA
| | | |
Collapse
|
2
|
Eckel CE, Kim WK, Grothusen C, Tiyerili V, Elsässer A, Sötemann D, Schlüter J, Choi YH, Charitos EI, Renker M, Hamm CW, Dohmen G, Möllmann H, Blumenstein J. Comparison of the New-Generation Self-Expanding NAVITOR Transcatheter Heart Valve with Its Predecessor, the PORTICO, in Severe Native Aortic Valve Stenosis. J Clin Med 2023; 12:3999. [PMID: 37373693 DOI: 10.3390/jcm12123999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 06/08/2023] [Accepted: 06/09/2023] [Indexed: 06/29/2023] Open
Abstract
BACKGROUND Third-generation transcatheter heart valves (THVs) are designed to improve outcomes. Data on the new intra-annular self-expanding NAVITOR are scarce. AIMS The aim of this analysis was to compare outcomes between the PORTICO and the NAVITOR systems. METHODS Data from 782 patients with severe native aortic stenosis treated with PORTICO (n = 645) or NAVITOR (n = 137) from 05/2012 to 09/2022 were evaluated. The clinical and hemodynamic outcomes of 276 patients (PORTICO, n = 139; NAVITOR, n = 137) were evaluated according to VARC-3 recommendations. RESULTS Rates of postprocedural more-than-mild paravalvular leakage (PVL) were significantly lower for NAVITOR than for PORTICO (7.2% vs. 1.5%, p = 0.041). In addition, severe bleeding rates (27.3% vs. 13.1%, p = 0.005) and major vascular complications (5.8% vs. 0.7%, p = 0.036) were lower in the NAVITOR group. The mean gradients (7 vs. 8 mmHg, p = 0.121) and calculated aortic valve areas (1.90 cm2 vs. 1.99 cm2, p = 0.235) were comparable. Rates of PPI were similarly high in both groups (15.3 vs. 21.6, p = 0.299). CONCLUSIONS The NAVITOR demonstrated favorable in-hospital procedural outcome data, with lower rates of relevant PVL, major vascular complications, and severe bleeding than its predecessor the PORTICO and preserved favorable hemodynamic outcomes.
Collapse
Affiliation(s)
- Clemens Enno Eckel
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
- Department of Cardiology, University of Oldenburg, 26129 Oldenburg, Germany
| | - Won-Keun Kim
- Department of Cardiac Surgery, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
- Department of Cardiology, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
| | - Christina Grothusen
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
- Department of Cardiac and Vascular Surgery, University of Kiel, 24098 Kiel, Germany
| | - Vedat Tiyerili
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Albrecht Elsässer
- Department of Cardiology, University of Oldenburg, 26129 Oldenburg, Germany
| | - Dagmar Sötemann
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Judith Schlüter
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
- Department of Cardiology, University of Oldenburg, 26129 Oldenburg, Germany
| | - Yeong-Hoon Choi
- Department of Cardiac Surgery, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
| | | | - Matthias Renker
- Department of Cardiology, Kerckhoff Heart Center, 61231 Bad Nauheim, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site Rhine-Main, 55131 Bad Nauheim, Germany
| | - Christian W Hamm
- German Center for Cardiovascular Research (DZHK), Partner Site Rhine-Main, 55131 Bad Nauheim, Germany
- Department of Cardiology, University of Giessen, 35390 Giessen, Germany
| | - Guido Dohmen
- Department of Cardiac Surgery, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Helge Möllmann
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
| | - Johannes Blumenstein
- Department of Cardiology, St. Johannes Hospital, 44137 Dortmund, Germany
- Department of Cardiology, University of Oldenburg, 26129 Oldenburg, Germany
| |
Collapse
|