1
|
Piovan G, Bori E, Padalino M, Pianigiani S, Innocenti B. Biomechanical analysis of patient specific cone vs conventional stem in revision total knee arthroplasty. J Orthop Surg Res 2024; 19:439. [PMID: 39068461 PMCID: PMC11282788 DOI: 10.1186/s13018-024-04936-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Accepted: 07/21/2024] [Indexed: 07/30/2024] Open
Abstract
BACKGROUND In revision total knee arthroplasty, addressing significant bone loss often involves the use of cemented or press-fit stems to ensure implant stability and long-term fixation. A possible alternative to stem was recently introduced utilizing custom-made porous metaphyseal cones, designed to reconstruct the missing tibial and femoral geometries. Early clinical and radiological assessments have shown promising results. The objective of this research was to biomechanically evaluate the performances of these custom-made cones. METHODS The biomechanical study was conducted using a validated finite element model. The bone geometries of a patient (selected for their history of four knee revisions due to infection and periprosthetic fractures, followed by a successful treatment with custom-made 3D-printed metaphyseal cones) were employed for the study. On these bone models, different revision scenarios were simulated and examined biomechanically: (A) custom-made cementless metaphyseal cones; (B) cemented stems; (C) press-fit stems; (D) distal femoral reconstruction with press-fit stem. All the models were analyzed at 0 °and 90 °of flexion, under physiological load conditions simulating daily activities; stress distribution, average Von-Mises stresses and risk of fracture were then analyzed and compared among configurations. RESULTS The use of custom-made 3D-printed cones exhibited the most favorable stress distribution in both femoral and tibial bones. Tibial bone stress was evenly distributed in custom-made cone configurations, while stress concentration was observed in distal regions for the other scenarios. Additionally, custom-made cones displayed overall homogeneity and lower stress levels, potentially contributing to limit pain. Symmetrical stress distribution was observed between the lateral and medial proximal tibia in custom-made cone models, whereas other scenarios exhibited uneven stress, particularly in the anterior tibial bone. CONCLUSIONS The biomechanical analysis of porous custom-made metaphyseal cones in re-revision arthroplasties is in agreement with the positive clinical and radiological outcomes. These findings provide valuable insights into the potential benefits of using custom-made cones, which offer more uniform stress distribution and may contribute to improve patient outcomes in revision TKA procedures. Further studies in this direction are warranted to validate these biomechanical findings.
Collapse
Affiliation(s)
- Gianluca Piovan
- Department of Orthopaedic and Traumatology, S. Cuore-Don Calabria Hospital, Negrar, Italy
| | - Edoardo Bori
- BEAMS Department (Bio Electro and Mechanical Systems), École Polytechnique de Bruxelles, Université Libre de Bruxelles, Av. F. Roosevelt, 50 CP165/56, Brussels, 1050, Belgium
- Département ECAM, Haute Ecole ICHEC-ECAM-ISFSC, Woluwe-Saint-Lambert, Belgium
| | - Marika Padalino
- BEAMS Department (Bio Electro and Mechanical Systems), École Polytechnique de Bruxelles, Université Libre de Bruxelles, Av. F. Roosevelt, 50 CP165/56, Brussels, 1050, Belgium
| | - Silvia Pianigiani
- BEAMS Department (Bio Electro and Mechanical Systems), École Polytechnique de Bruxelles, Université Libre de Bruxelles, Av. F. Roosevelt, 50 CP165/56, Brussels, 1050, Belgium
- Adler Ortho, Cormano, Milan, 20032, Italy
| | - Bernardo Innocenti
- BEAMS Department (Bio Electro and Mechanical Systems), École Polytechnique de Bruxelles, Université Libre de Bruxelles, Av. F. Roosevelt, 50 CP165/56, Brussels, 1050, Belgium.
| |
Collapse
|
2
|
Cao Z, Xiang L, Sun B, Gao K, Yu J, Zhou G, Duan X, Yan W, Lin F, Li Z, Wang R, Lv Y, Ren F, Yao Y, Lu Q. A reversible implantable memristor for health monitoring applications. Mater Today Bio 2024; 26:101096. [PMID: 38831909 PMCID: PMC11145331 DOI: 10.1016/j.mtbio.2024.101096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2024] [Revised: 05/08/2024] [Accepted: 05/19/2024] [Indexed: 06/05/2024] Open
Abstract
Conventional implantable electronics based on von Neumann architectures encounter significant limitations in computing and processing vast biological information due to computational bottlenecks. The memristor with integrated memory-computing and low power consumption offer a promising solution to overcome the computational bottleneck and Moore's law limitations of traditional silicon-based implantable devices, making them the most promising candidates for next-generation implantable devices. In this work, a highly stable memristor with an Ag/BaTiO3/MnO2/FTO structure was fabricated, demonstrating retention characteristics exceeding 1200 cycles and endurance above 1000 s. The device successfully exhibited three-stage responses to biological signals after implantation in SD (Sprague-Dawley) rats. Importantly, the memristor perform remarkable reversibility, maintaining over 100 cycles of stable repetition even after extraction from the rat. This study provides a new perspective on the biomedical application of memristors, expanding the potential of implantable memristive devices in intelligent medical fields such as health monitoring and auxiliary diagnostics.
Collapse
Affiliation(s)
- Zelin Cao
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Micro-and Nano-technology Research Center, State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Frontier Institute of Science and Technology (FIST), Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
| | - Linbiao Xiang
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
| | - Bai Sun
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Micro-and Nano-technology Research Center, State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Frontier Institute of Science and Technology (FIST), Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
| | - Kaikai Gao
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Micro-and Nano-technology Research Center, State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Frontier Institute of Science and Technology (FIST), Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
| | - Jiawei Yu
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
| | - Guangdong Zhou
- College of Artificial Intelligence, Brain-inspired Computing & Intelligent Control of Chongqing Key Lab, Southwest University, Chongqing, 400715, China
| | - Xuegang Duan
- Micro-and Nano-technology Research Center, State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Frontier Institute of Science and Technology (FIST), Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
| | - Wentao Yan
- Micro-and Nano-technology Research Center, State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Frontier Institute of Science and Technology (FIST), Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
| | - Fulai Lin
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
| | - Zhuoqun Li
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
| | - Ruixin Wang
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
| | - Yi Lv
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
| | - Fenggang Ren
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
| | - Yingmin Yao
- Department of Geriatric Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
| | - Qiang Lu
- Department of Geriatric Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China
| |
Collapse
|
3
|
Wu C, Tang YM, Kuo WT, Yip HT, Chau KY. Healthcare 5.0: A secure and distributed network for system informatics in medical surgery. Int J Med Inform 2024; 186:105415. [PMID: 38520907 DOI: 10.1016/j.ijmedinf.2024.105415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Revised: 01/30/2024] [Accepted: 03/16/2024] [Indexed: 03/25/2024]
Abstract
INTRODUCTION Health records serve not only as a database of a patient's health history and treatment process but also as a crucial tool for doctors to diagnose and treat patients. However, the storage and sharing of these records are sensitive issues as they involve maintaining patient privacy and ensuring data transparency, security, and interoperability between different parties. Challenges to achieving these goals in the current surgical process can impact the allocation of medical resources and surgical outcomes. METHODS This article proposes a healthcare 5.0 framework for medical surgery that deploys a secure and distributed network using Blockchain to demonstrate transactions between different parties in the orthopedic surgery process. The proposed network uses the Hyperledger Composer platform for deployment, and a patient-doctor-supplier orthopedic surgery network is designed and implemented to enable the safe sharing of medical records. RESULTS A benchmarking tool was implemented for analyzing different scenarios of applying blockchain technology to orthopedic surgery. The application of blockchain technology to orthopedic surgery presents a promising solution for data sharing and supply chain management in the field. The integration of blockchain with cloud storage and hybrid encryption ensures secure and efficient storage of Electronic Health Record (EHR) and Personal Health Record (PHR) data. By leveraging the tamper-proof nature of blockchain and addressing concerns regarding centralized data storage, this scenario demonstrates enhanced security, improved access efficiency, and privacy protection in medical data sharing. CONCLUSIONS The article demonstrates the feasibility of using an IoT-based blockchain network in orthopedic surgery, which can reduce medical errors and improve data interoperability among different parties. This unique application of blockchain enables secure sharing of medical records, ensuring transparency, security, and interoperability. The network design may also be applicable to other surgeries and medical applications in the future.
Collapse
Affiliation(s)
- Chenggang Wu
- Zhuhai City Polytechnic College of Marxism, Guangdong Province, China
| | - Yuk Ming Tang
- Department of Industrial and Systems Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong; Faculty of Business, City University of Macau, Macau.
| | - Wei Ting Kuo
- Department of Industrial and Systems Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong
| | - Ho Tung Yip
- The Jockey Club School of Public Health and Primary Care, The Chinese University of Hong Kong, Hong Kong
| | - Ka Yin Chau
- Faculty of Business, City University of Macau, Macau
| |
Collapse
|
4
|
Colbrunn RW, Loss JG, Gillespie CM, Pace EB, Nagle TF. Methodology for Robotic In Vitro Testing of the Knee. J Knee Surg 2024. [PMID: 38513696 DOI: 10.1055/a-2292-1157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/23/2024]
Abstract
The knee joint plays a pivotal role in mobility and stability during ambulatory and standing activities of daily living (ADL). Increased incidence of knee joint pathologies and resulting surgeries has led to a growing need to understand the kinematics and kinetics of the knee. In vivo, in silico, and in vitro testing domains provide researchers different avenues to explore the effects of surgical interactions on the knee. Recent hardware and software advancements have increased the flexibility of in vitro testing, opening further opportunities to answer clinical questions. This paper describes best practices for conducting in vitro knee biomechanical testing by providing guidelines for future research. Prior to beginning an in vitro knee study, the clinical question must be identified by the research and clinical teams to determine if in vitro testing is necessary to answer the question and serve as the gold standard for problem resolution. After determining the clinical question, a series of questions (What surgical or experimental conditions should be varied to answer the clinical question, what measurements are needed for each surgical or experimental condition, what loading conditions will generate the desired measurements, and do the loading conditions require muscle actuation?) must be discussed to help dictate the type of hardware and software necessary to adequately answer the clinical question. Hardware (type of robot, load cell, actuators, fixtures, motion capture, ancillary sensors) and software (type of coordinate systems used for kinematics and kinetics, type of control) can then be acquired to create a testing system tailored to the desired testing conditions. Study design and verification steps should be decided upon prior to testing to maintain the accuracy of the collected data. Collected data should be reported with any supplementary metrics (RMS error, dynamic statistics) that help illuminate the reported results. An example study comparing two different anterior cruciate ligament reconstruction techniques is provided to demonstrate the application of these guidelines. Adoption of these guidelines may allow for better interlaboratory result comparison to improve clinical outcomes.
Collapse
|
5
|
Suneja A, Deshpande SV, Pisulkar G, Taywade S, Awasthi AA, Salwan A, Goel S. Navigating the Divide: A Comprehensive Review of the Mechanical and Anatomical Axis Approaches in Total Knee Replacement. Cureus 2024; 16:e57938. [PMID: 38738158 PMCID: PMC11084915 DOI: 10.7759/cureus.57938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Accepted: 04/09/2024] [Indexed: 05/14/2024] Open
Abstract
This comprehensive review explores the mechanical and anatomical axis approaches in total knee replacement (TKR) surgery, addressing the ongoing debate within the orthopedic community. Emphasizing the significance of TKR in alleviating knee-related disorders, this review underscores the pivotal role of accurate alignment in achieving optimal surgical outcomes. The purpose is to navigate the divide between the well-established mechanical axis approach, focusing on a straight-line alignment, and the anatomical axis approach, aligning with natural knee landmarks. The analysis delves into the advantages, disadvantages, and clinical implications of each approach, offering a nuanced perspective on their efficacy. The conclusion emphasizes a patient-centric approach, recommending the adoption of hybrid strategies and the incorporation of emerging technologies for enhanced precision. The future of TKR aligns with personalized medicine, leveraging advancements in computer-assisted navigation, robotics, and patient-specific implants. Ongoing professional development and interdisciplinary collaboration are crucial for surgeons, and as the field evolves, innovations in artificial intelligence, imaging, and 3D printing are expected to shape the trajectory of TKR alignment approaches.
Collapse
Affiliation(s)
- Anmol Suneja
- Orthopedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| | - Sanjay V Deshpande
- Orthopedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| | - Gajanan Pisulkar
- Orthopedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| | - Shounak Taywade
- Orthopedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| | - Abhiram A Awasthi
- Orthopedics and Traumatology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| | - Ankur Salwan
- Orthopedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| | - Sachin Goel
- Orthopedics, Jawaharlal Nehru Medical College, Datta Meghe Institute of Higher Education & Research, Wardha, IND
| |
Collapse
|
6
|
Saeed AZ, Khaleeq T, Ahmed U, Ajula R, Boutefnouchet T, D'Alessandro P, Malik SS. No clinical advantage with customized individually made implants over conventional off-the-shelf implants in total knee arthroplasty: a systematic review and meta-analysis. Arch Orthop Trauma Surg 2024; 144:1311-1330. [PMID: 37979098 DOI: 10.1007/s00402-023-05090-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Accepted: 09/25/2023] [Indexed: 11/19/2023]
Abstract
INTRODUCTION Total knee arthroplasty (TKA) can be performed with either conventional off-the-shelf (OTS) or customized individually-made (CIM) implants. The evidence for CIM implants is limited and variable, and the aim of this review was to compare clinical and radiological outcomes between CIM and OTS implants. METHODS A systematic review and meta-analysis were conducted in accordance with PRISMA guidelines. Studies reporting on clinical, radiological, or alignment outcomes for CIM and OTS implants were selected. The studies were appraised using the Methodical index for non-randomized studies tool. RESULTS Twenty-three studies fulfilled the inclusion criteria. The studies comprised 2856 CIM and 1877 OTS TKAs. Revision rate was higher with CIM (5.9%) compared to OTS (3.7%) implants [OR 1.23(95% CI 0.69-2.18)]. Manipulation under anesthesia (MUA) was higher in CIM (2.2%) compared to OTS (1.1%) group [OR 2.95(95% CI 0.95-9.13)] and complications rate was higher in CIM (5%) vs. OTS (4.5%) [OR 1.45(95% CI 0.53-3.96)] but neither reached statistical significance. Length of stay was significantly shorter in CIM group 2.9 days vs. 3.5 days [MD - 0.51(95% CI - 0.82 to - 0.20)]. Knee Society Score showed no difference between CIM and OTS groups for Knee 90.5 vs. 90.6 [MD - 0.27(95% CI - 4.27 to 3.73)] and Function 86.1 vs. 83.1 [MD 1.51(95% CI - 3.69 to 6.70)]. CONCLUSION CIM implants in TKA have theoretical benefits over OTS prostheses. However, in this present review, CIM implants were associated with higher revisions, MUA, and overall complication rates. There was no difference in outcome score and CIM implants did not improve overall target alignment; however, more CIM TKAs were found to be in the HKA target zone compared to OTS TKAs. The findings of this review do not support the general utilization of CIM over OTS implants in TKA.
Collapse
Affiliation(s)
- Abu Z Saeed
- The Robert Jones and Agnes Hunt Orthopaedic Hospital, Gobowen, Oswestry, SY10 7AG, UK.
| | - Tahir Khaleeq
- The Robert Jones and Agnes Hunt Orthopaedic Hospital, Gobowen, Oswestry, SY10 7AG, UK
| | - Usman Ahmed
- Worcestershire Acute Hospitals NHS Trust, Worcester, UK
| | - Randeep Ajula
- University Hospitals of Leicester NHS Trust, Leicester, UK
| | | | - Peter D'Alessandro
- Orthopaedic Research Foundation of Western Australia, Medical School, Discipline of Surgery, University of Western Australia, Perth, Australia
| | | |
Collapse
|
7
|
Kulkarni PG, Paudel N, Magar S, Santilli MF, Kashyap S, Baranwal AK, Zamboni P, Vasavada P, Katiyar A, Singh AV. Overcoming Challenges and Innovations in Orthopedic Prosthesis Design: An Interdisciplinary Perspective. BIOMEDICAL MATERIALS & DEVICES (NEW YORK, N.Y.) 2023:1-12. [PMID: 37363137 PMCID: PMC10180679 DOI: 10.1007/s44174-023-00087-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Accepted: 04/29/2023] [Indexed: 06/28/2023]
Abstract
Recent advances in the orthopedic prostheses design have significantly improved the quality of life for individuals with orthopedic disabilities. However, there are still critical challenges that need to be addressed to further enhance the functionality of orthopedic prostheses improving biocompatibility to promote better integration with natural tissues, enhancing durability to withstand the demands of daily use, and improving sensory feedback for better control of movement are the most pressing issues. To address these challenges, promising emerging solutions such as smart prosthetics, 3D printing, regenerative medicine, and artificial intelligence have been developed. These innovative technologies hold the potential to significantly enhance the functionality of orthopedic prostheses. Realizing the full potential of these next-generation orthopedic prostheses requires addressing several critical factors. These include interdisciplinary collaboration between experts in orthopedics, materials science, biology, and engineering, increased investment in research and development, standardization of components to ensure quality and reliability, and improved access to prosthetics. A comprehensive review of these challenges and considerations for future orthopedic prosthesis design is s provided in this paper addressing the further advances to the field. By addressing these issues, we can continue to improve the lives of individuals with orthopedic disabilities and further enhance the field of orthopedic prosthetics.
Collapse
Affiliation(s)
| | - Namuna Paudel
- Department of Chemistry, Amrit Campus, Institute of Science and Technology, Tribhuvan University, Lainchaur, Kathmandu, 44600 Nepal
| | - Shilpa Magar
- Seeta Nursing Home, Shivaji Nagar, Nashik, Maharashtra 422002 India
| | | | | | | | - Paolo Zamboni
- Chair Vascular Diseases Center, University of Ferrara, 44124 Ferrara, Italy
| | - Priyank Vasavada
- M.S. Ramaiah Medical College and Hospital, Bengaluru, 560054 India
| | - Aman Katiyar
- Jain University, Bengaluru, Karnataka 560069 India
| | - Ajay Vikram Singh
- Department of Chemical and Product Safety, German Federal Institute of Risk Assessment (BfR), Maxdohrnstrasse 8-10, 10589 Berlin, Germany
| |
Collapse
|
8
|
Le Stum M, Bertin T, Le Goff-Pronost M, Apremont C, Dardenne G, Rolland-Lozachmeur G, Stindel E. Three-Dimensional Printed Knee Implants: Insights into Surgeons' Points of View. J Pers Med 2023; 13:jpm13050811. [PMID: 37240981 DOI: 10.3390/jpm13050811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 05/05/2023] [Accepted: 05/06/2023] [Indexed: 05/28/2023] Open
Abstract
Three-dimensional printing is a technology that has been developed and applied in several medical specialties, especially orthopedic surgery. Knee arthroplasty is the most commonly performed procedure. To fit the morphology of each knee, surgeons can choose between different standardized off-the-shelf implant sizes or opt for customized 3D-printed implants. However, routine adoption of the latter has been slow and faces several barriers. Existing studies focus on technical improvements or case studies and do not directly address the surgeon's perspective. Our study invited surgeons to express themselves freely and answer the question "What do you think about the manufacture of a prosthesis by 3D printing?". The questionnaire was completed by 90 surgeons. On average, they had more than 10 years of experience (52, 57.8% ± 10.2%), worked in public hospitals (54, 60% ± 10.1%), and performed between 0 and 100 prostheses per year (60, 66.7% ± 9.7%). They also reported not using planning software (47, 52.2% ± 9.7%), navigation systems, or robots (62, 68.9% ± 9.6%). Regarding the use of technological innovation, they agreed on the extra surgical time needed (67, 74.4% ± 9.0%). The answers obtained were classified according to two criteria: (i) opinions, and (ii) motivations. Among the respondents, 51 (70% ± 9.5%) had positive and 22 (30% ± 9.5%) had negative opinions about 3D printing. The motivations were distributed among seven categories (surgery, materials, costs, logistics, time, customization, and regulatory) and mainly related to "pre-surgery" and "post-surgery" concerns. Finally, the results showed that the use of navigation systems or robots may be associated with a more positive view of 3DP. The purpose of our study was to examine knee surgeons' perceptions of 3DP at a time of significant expansion of this technology. Our study showed that there was no opposition to its implementation, although some surgeons indicated that they were waiting for validated results. They also questioned the entire supply chain, including hospitals, insurance companies, and manufacturers. Although there was no opposition to its implementation, 3D printing is at a crucial point in its development and its full adoption will require advances in all areas of joint replacement.
Collapse
Affiliation(s)
- Mathieu Le Stum
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Faculté de Médecine de Brest, Université de Brest, Université de Bretagne Occidentale, 29200 Brest, France
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Institut National de la Santé et de la Recherche Médicale, INSERM, 29200 Brest, France
| | - Thomas Bertin
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Faculté de Médecine de Brest, Université de Brest, Université de Bretagne Occidentale, 29200 Brest, France
| | - Myriam Le Goff-Pronost
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, M@rsouin, Institut Mines-Telecom, IMT Atlantique, 29200 Brest, France
| | - Claire Apremont
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Faculté de Médecine de Brest, Université de Brest, Université de Bretagne Occidentale, 29200 Brest, France
| | - Guillaume Dardenne
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Centre Hospitalo-Universitaire de Brest, CHU Brest, 29200 Brest, France
| | - Ghislaine Rolland-Lozachmeur
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Faculté de Médecine de Brest, Université de Brest, Université de Bretagne Occidentale, 29200 Brest, France
| | - Eric Stindel
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Faculté de Médecine de Brest, Université de Brest, Université de Bretagne Occidentale, 29200 Brest, France
- Laboratoire de Traitement de l'Information Médicale (LATIM), UMR 1101, Centre Hospitalo-Universitaire de Brest, CHU Brest, 29200 Brest, France
| |
Collapse
|
9
|
Aseptic revision total knee arthroplasty outcomes were equivalent to patients' own pre-failure state but inferior to patients without revision. Knee Surg Sports Traumatol Arthrosc 2023; 31:822-829. [PMID: 34676450 DOI: 10.1007/s00167-021-06776-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 10/13/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE The purpose of this study was to (1) longitudinally compare the patient-reported outcome measures (PROMs) of the same patients who underwent primary TKA and revision TKA, and (2) compared the results of these revision TKA with a matched cohort of well-functioning primary TKA. The hypothesis was revision TKA could result in equivalent outcomes to patients' own primary TKA or the primary TKA of patients who did not require revision. METHODS Prospectively collected data of 123 patients who underwent primary TKA and subsequently aseptic revision TKA ("revised group"), were matched using nearest-neighbor method to 123 well-functioning primary TKA that did not require revision ("control group"). Preoperative (prior to primary TKA), at time of failure (prior to revision TKA), postoperative 6-month and 2-year PROMs included Knee Society scores (KSS), Oxford Knee Score (OKS) and Short Form-36 (SF-36). Minimal clinically important difference (MCID) attainment was analyzed. Wilcoxon and McNemar's tests were used to compare outcomes within the revised group (primary vs revision), Mann-Whitney U test and Chi-Square test for the revised and control groups. RESULTS The revised group had poorer KSS objective (p = 0.045), KSS functional (p < 0.001), OKS (p = 0.011) and SF-36 PCS (p < 0.001) at time of failure (prior to revision TKA), compared to their preoperative PROMs (prior to primary TKA). Revision TKA resulted in restoration of KSS objective, OKS and SF-36 PCS (NS) that were equivalent to their primary TKA, but poorer KSS functional (p < 0.050). Patients in the revised group had a lower proportion of MCID attainment in KSS objective (p = 0.014) and OKS (p < 0.001) at 2-year after primary TKA when compared to the control group. Revision TKA also led to poorer KSS objective, KSS functional and SF-36 PCS (p < 0.050) when compared to primary TKA of the control group. CONCLUSION Outcomes following aseptic revision were equivalent to patients' own pre-failure state but inferior to patients with non-revised implants. An individualized approach toward goal setting and assessing adequacy of aseptic revision TKA can be adopted based on patients' pre-failure outcomes. LEVEL OF EVIDENCE III.
Collapse
|
10
|
Schelker BL, Moret CS, von Eisenhart-Rothe R, Graichen H, Arnold MP, Leclercq V, Huegli RW, Hirschmann MT. The impact of different alignment strategies on bone cuts for neutral knee phenotypes in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2022; 31:1267-1275. [PMID: 36326877 PMCID: PMC10050061 DOI: 10.1007/s00167-022-07209-7] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Accepted: 10/24/2022] [Indexed: 11/06/2022]
Abstract
PURPOSE The purpose of this study was to simulate and visualise the influence of the alignment strategy on bone resection in neutral knee phenotypes. It was hypothesised that different amounts of bone resection would be required depending on the alignment strategy chosen. The hypothesis was that by visualising the corresponding bone cuts, it would be possible to assess which of the different alignment strategies required the least change to the soft tissues for the chosen phenotype but still ensured acceptable component alignment and could, therefore, be considered the most ideal alignment strategy. METHODS Simulations of the different alignment strategies (mechanical, anatomical, restricted kinematic and unrestricted kinematic) regarding their bone resections were performed on four common exemplary neutral knee phenotypes. NEUHKA0° VARFMA 90° VALTMA90°, NEUHKA0° NEUFMA 93° NEUTMA87°, NEUHKA0° VALFMA 96° NEUTMA87° and NEUHKA0° VALFMA 99° VARTMA84°. The phenotype system used categorises knees based on overall limb alignment (i.e. hip knee angle) but also considers joint line obliquity (i.e. TKA and FMA) and has been used globally since its introduction in 2019. These simulations are based on long leg weightbearing radiographs. It is assumed that a change of 1° in the alignment of the joint line corresponds to correspond to 1 mm of distal condyle offset. RESULTS In the most common neutral phenotype NEUHKA0° NEUFMA 93° NEUTMA87°, with a prevalence of 30%, bone cuts remain below 4 mm regardless of alignment strategy. The greatest changes in the obliquity of the joint line can be expected for the mechanical alignment of the phenotype NEUHKA0° VALFMA 99° VARTMA84° where the medial tibia is raised by 6 mm and the lateral femur is shifted distally by 9 mm. In contrast, the NEUHKA0° VARFMA 90° VALTMA90° phenotype requires no change in joint line obliquity if the mechanical alignment strategy is used. CONCLUSION Illustrations of alignment strategies help the treating surgeon to estimate the postoperative joint line obliquity. When considering the alignment strategy, it seems reasonable to prefer a strategy where the joint line obliquity is changed as little as possible. Although for the most common neutral knee phenotype the choice of alignment strategy seems to be of negligible importance, in general, even for neutral phenotypes, large differences in bone cuts can be observed depending on the choice of alignment strategy.
Collapse
Affiliation(s)
- Benjamin L Schelker
- Department of Orthopedic Surgery and Traumatology, Head Knee Surgery and DKF Head of Research, Kantonsspital Baselland, Bruderholz, 4101, Bottmingen, Switzerland.,Department of Clinical Research, Regenerative Medicine & Biomechanics, Research Group Michael T. Hirschmann, University of Basel, 4001, Basel, Switzerland
| | - Céline S Moret
- Department of Orthopedic Surgery and Traumatology, Head Knee Surgery and DKF Head of Research, Kantonsspital Baselland, Bruderholz, 4101, Bottmingen, Switzerland.,Department of Clinical Research, Regenerative Medicine & Biomechanics, Research Group Michael T. Hirschmann, University of Basel, 4001, Basel, Switzerland
| | - Rüdiger von Eisenhart-Rothe
- Department of Orthopedics and Sports Orthopedics, Klinikum Rechts Der Isar, Technical University Munich, Ismaningerstr. 22, 81675, Munich, Germany
| | - Heiko Graichen
- Department of Arthroplasty, Sports Medicine and Traumatology, Orthopaedic Hospital Lindenlohe, Indanone 18, 92421, Schwandorf, Germany
| | - Markus P Arnold
- LEONARDO, Hirslanden Klinik Birshof, Münchenstein, Switzerland
| | | | - Rolf W Huegli
- Institute of Radiology and Nuclear Medicine, Kantonsspital Baselland, Bruderholz, 4101, Bottmingen, Switzerland
| | - Michael T Hirschmann
- Department of Orthopedic Surgery and Traumatology, Head Knee Surgery and DKF Head of Research, Kantonsspital Baselland, Bruderholz, 4101, Bottmingen, Switzerland. .,Department of Clinical Research, Regenerative Medicine & Biomechanics, Research Group Michael T. Hirschmann, University of Basel, 4001, Basel, Switzerland.
| |
Collapse
|
11
|
Custom TKA combined with personalised coronal alignment yield improvements that exceed KSS substantial clinical benefits. Knee Surg Sports Traumatol Arthrosc 2022; 30:2958-2965. [PMID: 35182169 DOI: 10.1007/s00167-022-06867-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 12/31/2021] [Indexed: 10/19/2022]
Abstract
PURPOSE The purpose of this study was to report Knee Society Scores (KSS) at 12-month follow-up in a series of 266 knees that received custom TKA. The hypothesis was that custom TKA combined with personalised alignment would yield improvements greater than substantial clinical benefits (SCB) of KSS Knee and Function. METHODS From a consecutive series of 905 patients (918 knees) that received primary TKAs, 261 (29%) patients (266 knees) received computed tomography (CT)-based posterior-stabilised cemented custom TKA. Knees were aligned aiming to preserve or restore constitutional alignment within predetermined limits of 85°-95° for femoral mechanical angle (FMA) and tibial mechanical angle (TMA), and 175°-183° for hip knee ankle (HKA) angle. The KSS Knee and Function were collected preoperatively and 12 months postoperatively, to determine if patients achieved SCB. Uni- and multivariable analyses were performed to determine associations between KSS scores (Knee and Function) and patient demographics as well as pre- and postoperative radiographic alignments. RESULTS Of the initial cohort of 261 patients, 4 (1.8%) were reoperated for patellar resurfacing, 1 (0.4%) for lavage to treat infection, and 1 (0.4%) had arthroscopy to treat a stiff knee with < 90° range of motion. Complete clinical records were available for 227 patients (232 knees, 87%) that comprised 102 men (5 bilateral) and 125 women. At 12-month follow-up, mean improvements in KSS Knee and Function scores were, respectively, 61.0 ± 13.0 and 42.7 ± 16.7, which exceeded the SCB of KSS. Comparison of knees inside versus outside the target zone revealed no differences in KSS Knee (94.1 ± 9.1 versus 94.3 ± 9.0, n.s.) and Function (96.1 ± 9.2 versus 96.3 ± 8.9, n.s.). Multivariable analysis revealed worse KSS Knee in knees with preoperative FMA > 95° (β = - 6.21; p = 0.023), but no association between KSS Function and patient demographics or pre- and postoperative radiographic alignments. CONCLUSIONS Custom TKA combined with personalised alignment yielded improvements that exceeded substantial clinical benefits of KSS Knee and Function scores. These findings demonstrate the feasibility of custom TKA with 'personalised alignment' and encourage further investigations using comparative studies at longer follow-up. LEVEL OF EVIDENCE IV, case series.
Collapse
|
12
|
Serikova-Esengeldina D, Glushkova N, Abdushukurova G, Mussakhanova A, Mukhamejanova A, Khismetova Z, Bokov D, Ivankov A, Goremykina M, Semenova Y. Cost-utility analysis of total knee arthroplasty alone and in comparison with post-surgical rehabilitation and conservative treatment in the Republic of Kazakhstan. COST EFFECTIVENESS AND RESOURCE ALLOCATION 2022; 20:47. [PMID: 36050692 PMCID: PMC9438142 DOI: 10.1186/s12962-022-00379-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Accepted: 08/11/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Despite ample international knowledge on cost-effectiveness of total knee arthroplasty (TKA), it has never been a subject of investigation in Kazakhstan or other post-Soviet economies. Our study aimed to carry-out the cost-utility analysis of TKA alone and in comparison with post-surgical rehabilitation and conservative treatment at health care facilities of Kazakhstan. METHODS Two hundred and forty four patients with knee osteoarthritis (KOA) who underwent TKA in orthopedic departments of Almaty, Nur-Sultan and Semey hospitals between January 1, 2019 and September 30, 2019 were followed-up for 12 months. The health-related quality of life was measured by the EQ-5D utility and Western Ontario and McMaster Universities Osteoarthritis Index was used to measure the patients' health status. The costs were estimated from the view of health care provider. We calculated the cost per QALY, the Cost-Utility Ratio and the Incremental Cost-Effectiveness Ratio. RESULTS At the time of 12-month follow-up patients who received TKA alone or with the course of rehabilitation showed benefit over patients from the group of conservative treatment in terms of overall health status. Mean QALY gained at 12 months constituted 1.66 for the group that received TKA with rehabilitation, 1.48 for the group that received TKA alone and 0.24 for the group that received conservative treatment. Mean cost per QALY gained was USD 30 795.75 for KOA patients under conservative treatment, USD 6 323.69 for KOA patients subjected to TKA and USD 2 670.32 for KOA patients with rehabilitation course after TKA. CONCLUSION Both TKA and TKA with rehabilitation could be considered as highly cost-effective interventions. The data obtained could be of interest for policy makers, medical professionals and KOA patients.
Collapse
Affiliation(s)
| | - Natalya Glushkova
- Faculty of Medicine and Healthcare, Al-Farabi Kazakh National University, Almaty, Kazakhstan
| | - Gulzada Abdushukurova
- Institute of Higher Medical Postgraduate Education, Akhmet Yassawi University, Turkestan, Kazakhstan
| | - Akmaral Mussakhanova
- Department of Public Health and Management, Astana Medical University, Nur-Sultan, Kazakhstan
| | - Ainur Mukhamejanova
- Department of Family Medicine #2, Astana Medical University, Nur-Sultan, Kazakhstan
| | - Zaituna Khismetova
- Department of Public Health, Semey Medical University, Semey, Kazakhstan
| | - Dmitry Bokov
- Institute of Pharmacy, Sechenov First Moscow State Medical University, Moscow, Russia.,Laboratory of Food Chemistry, Federal Research Center of Nutrition, Biotechnology and Food Safety, Moscow, Russia
| | | | - Maiya Goremykina
- Department of Rheumatology and Noncommunicable Diseases, Semey Medical University, Semey, Kazakhstan
| | - Yuliya Semenova
- School of Medicine, Nazarbayev University, Nur-Sultan, Kazakhstan.
| |
Collapse
|
13
|
Gautam S, Bhatnagar D, Bansal D, Batra H, Goyal N. Recent advancements in nanomaterials for biomedical implants. BIOMEDICAL ENGINEERING ADVANCES 2022. [DOI: 10.1016/j.bea.2022.100029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
14
|
Capuani S, Malgir G, Chua CYX, Grattoni A. Advanced Strategies to Thwart Foreign Body Response to Implantable Devices. Bioeng Transl Med 2022; 7:e10300. [PMID: 36176611 PMCID: PMC9472022 DOI: 10.1002/btm2.10300] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 01/21/2022] [Accepted: 01/24/2022] [Indexed: 11/10/2022] Open
Abstract
Mitigating the foreign body response (FBR) to implantable medical devices (IMDs) is critical for successful long‐term clinical deployment. The FBR is an inevitable immunological reaction to IMDs, resulting in inflammation and subsequent fibrotic encapsulation. Excessive fibrosis may impair IMDs function, eventually necessitating retrieval or replacement for continued therapy. Therefore, understanding the implant design parameters and their degree of influence on FBR is pivotal to effective and long lasting IMDs. This review gives an overview of FBR as well as anti‐FBR strategies. Furthermore, we highlight recent advances in biomimetic approaches to resist FBR, focusing on their characteristics and potential biomedical applications.
Collapse
Affiliation(s)
- Simone Capuani
- Department of Nanomedicine Houston Methodist Research Institute Houston TX USA
- University of Chinese Academy of Science (UCAS) 19 Yuquan Road Beijing China
| | - Gulsah Malgir
- Department of Nanomedicine Houston Methodist Research Institute Houston TX USA
- Department of Biomedical Engineering University of Houston Houston TX USA
| | | | - Alessandro Grattoni
- Department of Nanomedicine Houston Methodist Research Institute Houston TX USA
- Department of Surgery Houston Methodist Hospital Houston TX USA
- Department of Radiation Oncology Houston Methodist Hospital Houston TX USA
| |
Collapse
|
15
|
Wendelspiess S, Kaelin R, Vogel N, Rychen T, Arnold MP. No difference in patient-reported satisfaction after 12 months between customised individually made and off-the-shelf total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2022; 30:2948-2957. [PMID: 35149877 PMCID: PMC9418302 DOI: 10.1007/s00167-022-06900-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Accepted: 01/16/2022] [Indexed: 11/27/2022]
Abstract
PURPOSE A subset of patients is usually not satisfied after a total knee arthroplasty (TKA). Customised individually made (CIM) TKA are deemed to overcome drawbacks of classical off-the-shelf (OTS) TKA, but evidence is still sparse. The aim of this study was to compare satisfaction of patients with CIM and OTS TKA. METHODS This prospective cohort study compared clinical and patient-reported outcome measures (PROM) between patients with CIM and OTS TKA. The primary outcome was patient satisfaction after 12 months. Secondary outcomes were the Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score (KOOS), the Forgotten Joint Score (FJS-12) and the EQ-5D-3L after 4 and 12 months. RESULTS Data were analysed from 74 CIM TKA and 169 OTS TKA between January 2017 and September 2020. Patients with CIM TKA were slightly younger, more often male, had a lower body mass index, a lower KSS and partially higher preoperative PROMs. Patient satisfaction after 12 months was high and comparable (CIM 87%, OTS 89%). All PROMs improved for both groups (p < 0.001) and did not differ after 12 months (p > 0.063). The majority of patients improved above the minimal important difference (range 65 to 89%) and reported a clear overall improvement (CIM 86%, OTS 87%). The postoperative KSS, notably regarding knee stability, was higher for CIM TKA (p < 0.001). CONCLUSION No difference was found in patient satisfaction between CIM and OTS TKA after 12 months. In both groups, patient satisfaction was high and PROMs improved considerably. LEVEL OF EVIDENCE II, prospective cohort study.
Collapse
Affiliation(s)
- Séverin Wendelspiess
- Practice LEONARDO, Hirslanden Clinic Birshof, Reinacherstrasse 28, 4142, Münchenstein, Switzerland
- Faculty of Medicine, University of Basel, Basel, Switzerland
| | - Raphael Kaelin
- Practice LEONARDO, Hirslanden Clinic Birshof, Reinacherstrasse 28, 4142, Münchenstein, Switzerland
| | - Nicole Vogel
- Practice LEONARDO, Hirslanden Clinic Birshof, Reinacherstrasse 28, 4142, Münchenstein, Switzerland.
- Faculty of Medicine, University of Basel, Basel, Switzerland.
| | - Thomas Rychen
- Practice LEONARDO, Hirslanden Clinic Birshof, Reinacherstrasse 28, 4142, Münchenstein, Switzerland
| | - Markus P Arnold
- Practice LEONARDO, Hirslanden Clinic Birshof, Reinacherstrasse 28, 4142, Münchenstein, Switzerland
- Faculty of Medicine, University of Basel, Basel, Switzerland
| |
Collapse
|
16
|
[Clinical studies in trauma surgery and orthopedics: read, interpret and implement]. Unfallchirurg 2021; 124:1007-1017. [PMID: 34761281 PMCID: PMC8579904 DOI: 10.1007/s00113-021-01101-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/06/2021] [Indexed: 12/01/2022]
Abstract
Für eine informierte, partizipative ärztliche Entscheidungsfindung müssen Sie neben Ihrem Erfahrungswissen aktuelle wissenschaftliche Daten berücksichtigen. Die digitale Informationsflut macht es im klinischen Alltag allerdings schwer, immer auf dem Stand des Wissens zu bleiben. Der Beitrag bietet einige Hilfen an, wie mit diesem Problem umgegangen werden kann. Ein grundlegendes Verständnis über Vor- und Nachwahrscheinlichkeiten sowie systematische Fehler (Bias) erleichtert die Abwägung zwischen Nutzen und Risiko z. B. einer (chirurgischen) Intervention im Vergleich zu einer nichtoperativen Therapie. Randomisierte Studien („randomized controlled trials“, RCT, mit allen modernen Modifikationen) liefern unverzerrte Ergebnisse, führen in Orthopädie und Unfallchirurgie evtl. zu einer stark selektierten, nichtrepräsentativen Stichprobe, und ihre Resultate müssen durch weitere, unabhängige RCT bestätigt oder widerlegt werden. Große beobachtende Datenmengen (z. B. aus Registern) können quasiexperimentell modelliert werden und RCT in der Gesundheitstechnologiebewertung flankieren.
Collapse
|
17
|
Asbai-Ghoudan R, Ruiz de Galarreta S, Rodriguez-Florez N. Analytical model for the prediction of permeability of triply periodic minimal surfaces. J Mech Behav Biomed Mater 2021; 124:104804. [PMID: 34481309 DOI: 10.1016/j.jmbbm.2021.104804] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 07/22/2021] [Accepted: 08/27/2021] [Indexed: 12/22/2022]
Abstract
Triply periodic minimal surfaces (TPMS) are mathematically defined cellular structures whose geometry can be quickly adapted to target desired mechanical response (structural and fluid). This has made them desirable for a wide range of bioengineering applications; especially as bioinspired materials for bone replacement. The main objective of this study was to develop a novel analytical framework which would enable calculating permeability of TPMS structures based on the desired architecture, pore size and porosity. To achieve this, computer-aided designs of three TPMS structures (Fisher-Koch S, Gyroid and Schwarz P) were generated with varying cell size and porosity levels. Computational Fluid Dynamics (CFD) was used to calculate permeability for all models under laminar flow conditions. Permeability values were then used to fit an analytical model dependent on geometry parameters only. Results showed that permeability of the three architectures increased with porosity at different rates, highlighting the importance of pore distribution and architecture. The computed values of permeability fitted well with the suggested analytical model (R2>0.99, p<0.001). In conclusion, the novel analytical framework presented in the current study enables predicting permeability values of TPMS structures based on geometrical parameters within a difference <5%. This model, which could be combined with existing structural analytical models, could open new possibilities for the smart optimisation of TPMS structures for biomedical applications where structural and fluid flow properties need to be optimised.
Collapse
Affiliation(s)
- Reduan Asbai-Ghoudan
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018, San Sebastian, Spain.
| | - Sergio Ruiz de Galarreta
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018, San Sebastian, Spain
| | - Naiara Rodriguez-Florez
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018, San Sebastian, Spain; IKERBASQUE, Basque Foundation for Science, Plaza Euskadi 5, 48009, Bilbao, Spain
| |
Collapse
|
18
|
Müller JH, Liebensteiner M, Kort N, Stirling P, Pilot P, Demey G. No significant difference in early clinical outcomes of custom versus off-the-shelf total knee arthroplasty: a systematic review and meta-analysis. Knee Surg Sports Traumatol Arthrosc 2021; 31:1230-1246. [PMID: 34432095 DOI: 10.1007/s00167-021-06678-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Accepted: 07/18/2021] [Indexed: 01/25/2023]
Abstract
PURPOSE The purpose of this systematic review and meta-analysis was to collect, synthesise and critically appraise findings of clinical studies that report outcomes of custom total knee arthroplasty (TKA). The hypothesis was that, compared to off-the-shelf (OTS) TKA, custom TKA would yield better surgical, clinical and radiographic outcomes. METHODS This systematic review and meta-analysis was performed in accordance with the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). On 8 February 2021, two authors independently searched and screened articles using MEDLINE®, Embase® and the Cochrane Library without restriction on date of publication. Findings from eligible articles were narratively synthesised and tabulated, and when ≥ 3 comparative studies reported the same outcome, results were pooled and summarised in forest plots. Quality assessments of the studies were done according to the guidelines of the Joanna Briggs Institute (JBI) Checklists. RESULTS A total of 15 articles were eligible for data extraction, of which 9 were case-control studies reporting on 929 custom versus 998 OTS TKA, 5 were case series reporting on results of 587 custom TKA, and 1 was a cross-sectional study reporting on results of 44 custom versus 132 OTS TKA. Five studies that compared early revision rates found the overall effect in favour of OTS TKA (odds ratio (OR), 0.4; p = n.s.) but the result did not reach statistical significance. Four studies found no statistically significant difference in KSS knee (standardised mean difference (SMD), - 0.10; p = n.s.) and function (SMD, 0.03; p = n.s.), and five studies found no statistically significant difference in range of motion (SMD, 0.02; p = n.s.). One study that compared bone-implant fit between custom and three OTS tibial components found no overhang but revealed under-coverage of up to 18% in knees with custom tibial baseplates. CONCLUSION Custom TKA demonstrated no significant benefits compared to OTS TKA in terms of pooled clinical outcomes, but had considerably higher early revision rates. The findings of the present systematic review and meta-analysis suggest the need for studies with better comparable groups and standardisation of reporting outcomes amongst studies, that could increase the quality of evidence and enable pooling of results in future meta-analyses. LEVEL OF EVIDENCE Level IV.
Collapse
Affiliation(s)
| | - Michael Liebensteiner
- Department of Orthopaedics and Traumatology, Medical University of Innsbruck, Anichstraße 35, 6020, Innsbruck, Austria
| | - Nanne Kort
- CortoClinics, Schijndel, The Netherlands
| | | | | | - Guillaume Demey
- Lyon-Ortho-Clinic, Clinique de la Sauvegarde, Ramsay Santé, 29 Avenue des Sources, 69009, Lyon, France
| |
Collapse
|
19
|
Yao Y, Mo Z, Wu G, Guo J, Li J, Wang L, Fan Y. A personalized 3D-printed plate for tibiotalocalcaneal arthrodesis: Design, fabrication, biomechanical evaluation and postoperative assessment. Comput Biol Med 2021; 133:104368. [PMID: 33864971 DOI: 10.1016/j.compbiomed.2021.104368] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2020] [Revised: 03/09/2021] [Accepted: 03/28/2021] [Indexed: 12/11/2022]
Abstract
Personalized plates (P-Plates) could provide improved clinical outcomes in joint fusion by enabling perfect geometric matching between irregular bone and implants. However, there is no unified application framework for P-Plates for joint fusion. The objective of this study was to develop such a framework for P-Plates for tibiotalocalcaneal arthrodesis. A patient-specific bone model was constructed based on CT images, and the P-Plate was preliminarily designed to match the bones. Finite element method was used to optimize the stress distribution and to evaluate the biomechanical performance of the P-Plate by comparing it with a traditional plate (T-Plate). Then, the P-Plate was manufactured via electron beam melting and implanted into the foot of a patient. Increasing the size of the preliminary designed plate alleviated the stress concentration and reduced the risk of failure. The maximum stresses of the plate and screw (214.3 MPa, 99.05 MPa) and the maximum tensile force of the screw in the P-Plate (181.4 N) fixation system were lower than those in the T-Plate (217.4 MPa, 255.4 MPa, and 230.1 N, respectively). The P-Plate was well-matched to the bone, and no complications occurred. The P-Plate achieved American Orthopaedic Foot & Ankle Society and Short-Form-36 scores of 64 and 75, respectively, 36 months post operation, which suggests that it could improve clinical outcomes. The design and fabrication methods, as well as mechanical and postoperative performance evaluation methods, for the P-Plate were systematically developed and provide a reference for constructing a unified application framework for P-Plate use in tibiotalocalcaneal arthrodesis.
Collapse
Affiliation(s)
- Yan Yao
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, 100191, Beijing, China.
| | - Zhongjun Mo
- Key Laboratory of Human Motion Analysis and Rehabilitation Technology of the Ministry of Civil Affairs, Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, National Research Centre for Rehabilitation Technical Aids, 100176, Beijing, China.
| | - Gang Wu
- Key Laboratory of Human Motion Analysis and Rehabilitation Technology of the Ministry of Civil Affairs, Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, National Research Centre for Rehabilitation Technical Aids, 100176, Beijing, China; Rehabilitation Hospital, National Research Center for Rehabilitation Technical Aids, 100176, Beijing, China.
| | - Junchao Guo
- Key Laboratory of Human Motion Analysis and Rehabilitation Technology of the Ministry of Civil Affairs, Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, National Research Centre for Rehabilitation Technical Aids, 100176, Beijing, China.
| | - Jian Li
- Key Laboratory of Human Motion Analysis and Rehabilitation Technology of the Ministry of Civil Affairs, Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, National Research Centre for Rehabilitation Technical Aids, 100176, Beijing, China.
| | - Lizhen Wang
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, 100191, Beijing, China.
| | - Yubo Fan
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, 100191, Beijing, China; Key Laboratory of Human Motion Analysis and Rehabilitation Technology of the Ministry of Civil Affairs, Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, National Research Centre for Rehabilitation Technical Aids, 100176, Beijing, China; Rehabilitation Hospital, National Research Center for Rehabilitation Technical Aids, 100176, Beijing, China; School of Engineering Medicine, Beihang University, 100191, Beijing, China.
| |
Collapse
|