Mäkinen H, Suhonen H, Siiskonen T, David C, Huotari S. Optimization of contrast and dose in x-ray phase-contrast tomography with a Talbot-Lau interferometer. Biomed Phys Eng Express 2024; 10:045045. [PMID: 38815565 DOI: 10.1088/2057-1976/ad5206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Accepted: 05/30/2024] [Indexed: 06/01/2024]
Abstract
X-ray phase-contrast imaging has become a valuable tool for biomedical research due to its improved contrast abilities over regular attenuation-based imaging. The recently emerged Talbot-Lau interferometer can provide quantitative attenuation, phase-contrast and dark-field image data, even with low-brilliance x-ray tube sources. Thus, it has become a valid option for clinical environments. In this study, we analyze the effects of x-ray tube voltage and total number of images on the contrast-to-noise ratio (CNR) and dose-weighted CNR (CNRD) calculated from tomographic transmission and phase-contrast data of a phantom sample. Constant counting statistics regardless of the voltage was ensured by adjusting the image exposure time for each voltage setting. The results indicate that the x-ray tube voltage has a clear effect on both image contrast and noise. This effect is amplified in the case of phase-contrast images, which is explained by the polychromatic x-ray spectrum and the dependence of interferometer visibility on the spectrum. CNRD is additionally affected by the total imaging time. While submerging the sample into a water container effectively reduces image artefacts and improves the CNR, the additional attenuation of the water must be compensated with a longer exposure time. This reduces dose efficiency. Both the CNR and CNRD are higher in the phase-contrast images compared to transmission images. For transmission images, and phase-contrast images without the water container, CNRD can be increased by using higher tube voltages (in combination with a lower exposure time). For phase-contrast images with the water container, CNRD is increased with lower tube voltages. In general, the CNRD does not strongly depend on the number of tomographic angles or phase steps used.
Collapse
Affiliation(s)
- Henrik Mäkinen
- Department of Physics, PO Box 64, FI-00014 University of Helsinki, Finland
| | - Heikki Suhonen
- Department of Physics, PO Box 64, FI-00014 University of Helsinki, Finland
| | - Teemu Siiskonen
- Department of Physics, PO Box 64, FI-00014 University of Helsinki, Finland
- Measurements and Environmental Monitoring, Radiation and Nuclear Safety Authority (STUK), Jokiniemenkuja 1, FI-01370 Vantaa, Finland
| | - Christian David
- Paul Scherrer Institute, Forschungsstrasse 111, CH-5232 Villigen, Switzerland
| | - Simo Huotari
- Department of Physics, PO Box 64, FI-00014 University of Helsinki, Finland
| |
Collapse
|
2
|
Tian Z, Tao S, Bai L, Xu Y, Liu X, Kuang C. A novel fusion method for X-ray phase contrast imaging based on fast adaptive bidimensional empirical mode decomposition. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2023; 31:1341-1362. [PMID: 37840465 DOI: 10.3233/xst-230180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/17/2023]
Abstract
BACKGROUNDS X-ray phase contrast imaging (XPCI) can separate the attenuation, refraction, and scattering signals of the object. The application of image fusion enables the concentration of distinctive information into a single image. Some methods have been applied in XPCI field, but wavelet-based decomposition approaches often result in loss of original data. OBJECTIVE To explore the application value of a novel image fusion method for XPCI system and computed tomography (CT) system. METHODS The means of fast adaptive bidimensional empirical mode decomposition (FABEMD) is considered for image decomposition to avoid unnecessary information loss. A parameter δ is proposed to guide the fusion of bidimensional intrinsic mode functions which contain high-frequency information, using a pulse coupled neural network with morphological gradients (MGPCNN). The residual images are fused by the energy attribute fusion strategy. Image preprocessing and enhancement are performed on the result to ensure its quality. The effectiveness of other image fusion methods has been compared, such as discrete wavelet transforms and anisotropic diffusion fusion. RESULTS The δ-guided FABEMD-MGPCNN method achieved either the first or second position in objective evaluation metrics with biological samples, as compared to other image fusion methods. Moreover, comparisons are made with other fusion methods used for XPCI. Finally, the proposed method applied in CT show expected results to retain the feature information. CONCLUSIONS The proposed δ-guided FABEMD-MGPCNN method shows potential feasibility and superiority over traditional and recent image fusion methods for X-ray differential phase contrast imaging and computed tomography systems.
Collapse
Affiliation(s)
- Zonghan Tian
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science & Engineering, Zhejiang University, Hangzhou, China
| | - Siwei Tao
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science & Engineering, Zhejiang University, Hangzhou, China
| | - Ling Bai
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science & Engineering, Zhejiang University, Hangzhou, China
| | - Yueshu Xu
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science & Engineering, Zhejiang University, Hangzhou, China
- ZJU-Hangzhou Global Scientific and Technological Innovation Center, Hangzhou, China
| | - Xu Liu
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science & Engineering, Zhejiang University, Hangzhou, China
- ZJU-Hangzhou Global Scientific and Technological Innovation Center, Hangzhou, China
- Ningbo Research Institute, Zhejiang University, Ningbo, China
- Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
| | - Cuifang Kuang
- State Key Laboratory of Extreme Photonics and Instrumentation, College of Optical Science & Engineering, Zhejiang University, Hangzhou, China
- ZJU-Hangzhou Global Scientific and Technological Innovation Center, Hangzhou, China
- Ningbo Research Institute, Zhejiang University, Ningbo, China
- Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, China
| |
Collapse
|
3
|
Low-density foreign body detection in food products using single-shot grid-based dark-field X-ray imaging. J FOOD ENG 2022. [DOI: 10.1016/j.jfoodeng.2022.111189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
4
|
Akstaller B, Schreiner S, Dietrich L, Rauch C, Schuster M, Ludwig V, Hofmann-Randall C, Michel T, Anton G, Funk S. X-ray Dark-Field Imaging for Improved Contrast in Historical Handwritten Literature. J Imaging 2022; 8:jimaging8090226. [PMID: 36135392 PMCID: PMC9501021 DOI: 10.3390/jimaging8090226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 08/12/2022] [Accepted: 08/18/2022] [Indexed: 11/18/2022] Open
Abstract
If ancient documents are too fragile to be opened, X-ray imaging can be used to recover the content non-destructively. As an extension to conventional attenuation imaging, dark-field imaging provides access to microscopic structural object information, which can be especially advantageous for materials with weak attenuation contrast, such as certain metal-free inks in paper. With cotton paper and different self-made inks based on authentic recipes, we produced test samples for attenuation and dark-field imaging at a metal-jet X-ray source. The resulting images show letters written in metal-free ink that were recovered via grating-based dark-field imaging. Without the need for synchrotron-like beam quality, these results set the ground for a mobile dark-field imaging setup that could be brought to a library for document scanning, avoiding long transport routes for valuable historic documents.
Collapse
Affiliation(s)
- Bernhard Akstaller
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erwin-Rommel-Str. 1, 91058 Erlangen, Germany
- Correspondence:
| | - Stephan Schreiner
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erwin-Rommel-Str. 1, 91058 Erlangen, Germany
| | - Lisa Dietrich
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erwin-Rommel-Str. 1, 91058 Erlangen, Germany
| | - Constantin Rauch
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erwin-Rommel-Str. 1, 91058 Erlangen, Germany
| | - Max Schuster
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erwin-Rommel-Str. 1, 91058 Erlangen, Germany
| | - Veronika Ludwig
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erwin-Rommel-Str. 1, 91058 Erlangen, Germany
| | - Christina Hofmann-Randall
- Universitätsbibliothek Handschriften und Graphische Sammlung, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 4, 91054 Erlangen, Germany
| | - Thilo Michel
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erwin-Rommel-Str. 1, 91058 Erlangen, Germany
| | - Gisela Anton
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erwin-Rommel-Str. 1, 91058 Erlangen, Germany
| | - Stefan Funk
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erwin-Rommel-Str. 1, 91058 Erlangen, Germany
| |
Collapse
|
5
|
Schreiner S, Akstaller B, Dietrich L, Meyer P, Neumayer P, Schuster M, Wolf A, Zielbauer B, Ludwig V, Michel T, Anton G, Funk S. Noise Reduction for Single-Shot Grating-Based Phase-Contrast Imaging at an X-ray Backlighter. J Imaging 2021; 7:178. [PMID: 34564104 PMCID: PMC8468938 DOI: 10.3390/jimaging7090178] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 08/26/2021] [Accepted: 09/02/2021] [Indexed: 11/21/2022] Open
Abstract
X-ray backlighters allow the capture of sharp images of fast dynamic processes due to extremely short exposure times. Moiré imaging enables simultaneously measuring the absorption and differential phase-contrast (DPC) of these processes. Acquiring images with one single shot limits the X-ray photon flux, which can result in noisy images. Increasing the photon statistics by repeating the experiment to gain the same image is not possible if the investigated processes are dynamic and chaotic. Furthermore, to reconstruct the DPC and transmission image, an additional measurement captured in absence of the object is required. For these reference measurements, shot-to-shot fluctuations in X-ray spectra and a source position complicate the averaging of several reference images for noise reduction. Here, two approaches of processing multiple reference images in combination with one single object image are evaluated regarding the image quality. We found that with only five reference images, the contrast-to-noise ratio can be improved by approximately 13% in the DPC image. This promises improvements for short-exposure single-shot acquisitions of rapid processes, such as laser-produced plasma shock-waves in high-energy density experiments at backlighter X-ray sources such as the PHELIX high-power laser facility.
Collapse
Affiliation(s)
- Stephan Schreiner
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander Universität Erlangen-Nürnberg, Erwin-Rommel-Straße 1, 91058 Erlangen, Germany; (B.A.); (L.D.); (M.S.); (A.W.); (V.L.); (T.M.); (G.A.); (S.F.)
| | - Bernhard Akstaller
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander Universität Erlangen-Nürnberg, Erwin-Rommel-Straße 1, 91058 Erlangen, Germany; (B.A.); (L.D.); (M.S.); (A.W.); (V.L.); (T.M.); (G.A.); (S.F.)
| | - Lisa Dietrich
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander Universität Erlangen-Nürnberg, Erwin-Rommel-Straße 1, 91058 Erlangen, Germany; (B.A.); (L.D.); (M.S.); (A.W.); (V.L.); (T.M.); (G.A.); (S.F.)
| | - Pascal Meyer
- Karlsruhe Institute of Technology, Institute of Microstructure Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany;
| | - Paul Neumayer
- GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstraße 1, 64291 Darmstadt, Germany; (P.N.); (B.Z.)
| | - Max Schuster
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander Universität Erlangen-Nürnberg, Erwin-Rommel-Straße 1, 91058 Erlangen, Germany; (B.A.); (L.D.); (M.S.); (A.W.); (V.L.); (T.M.); (G.A.); (S.F.)
| | - Andreas Wolf
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander Universität Erlangen-Nürnberg, Erwin-Rommel-Straße 1, 91058 Erlangen, Germany; (B.A.); (L.D.); (M.S.); (A.W.); (V.L.); (T.M.); (G.A.); (S.F.)
| | - Bernhard Zielbauer
- GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstraße 1, 64291 Darmstadt, Germany; (P.N.); (B.Z.)
| | - Veronika Ludwig
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander Universität Erlangen-Nürnberg, Erwin-Rommel-Straße 1, 91058 Erlangen, Germany; (B.A.); (L.D.); (M.S.); (A.W.); (V.L.); (T.M.); (G.A.); (S.F.)
| | - Thilo Michel
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander Universität Erlangen-Nürnberg, Erwin-Rommel-Straße 1, 91058 Erlangen, Germany; (B.A.); (L.D.); (M.S.); (A.W.); (V.L.); (T.M.); (G.A.); (S.F.)
| | - Gisela Anton
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander Universität Erlangen-Nürnberg, Erwin-Rommel-Straße 1, 91058 Erlangen, Germany; (B.A.); (L.D.); (M.S.); (A.W.); (V.L.); (T.M.); (G.A.); (S.F.)
| | - Stefan Funk
- Erlangen Centre for Astroparticle Physics (ECAP), Friedrich-Alexander Universität Erlangen-Nürnberg, Erwin-Rommel-Straße 1, 91058 Erlangen, Germany; (B.A.); (L.D.); (M.S.); (A.W.); (V.L.); (T.M.); (G.A.); (S.F.)
| |
Collapse
|
6
|
Graetz J, Balles A, Hanke R, Zabler S. Review and experimental verification of x-ray dark-field signal interpretations with respect to quantitative isotropic and anisotropic dark-field computed tomography. Phys Med Biol 2020; 65:235017. [PMID: 32916662 DOI: 10.1088/1361-6560/abb7c6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Talbot(-Lau) interferometric x-ray and neutron dark-field imaging has, over the past decade, gained substantial interest for its ability to provide insights into a sample's microstructure below the imaging resolution by means of ultra small angle scattering effects. Quantitative interpretations of such images depend on models of the signal origination process that relate the observable image contrast to underlying physical processes. A review of such models is given here and their relation to the wave optical derivations by Yashiro et al and Lynch et al as well as to small angle scattering is discussed. Fresnel scaling is introduced to explain the characteristic distance dependence observed in cone beam geometries. Moreover, a model describing the anisotropic signals of fibrous objects is derived. The Yashiro-Lynch model is experimentally verified both in radiographic and tomographic imaging in a monochromatic synchrotron setting, considering both the effects of material and positional dependence of the resulting dark-field contrast. The effect of varying sample-detector distance on the dark-field signal is shown to be non-negligible for tomographic imaging, yet can be largely compensated for by symmetric acquisition trajectories. The derived orientation dependence of the dark-field contrast of fibrous materials both with respect to variations in autocorrelation width and scattering cross section is experimentally validated using carbon fiber reinforced rods.
Collapse
Affiliation(s)
- J Graetz
- Lehrstuhl für Röntgenmikroskopie, Universität Würzburg, Josef-Martin-Weg 63, 97074 Würzburg, Germany. Fraunhofer IIS, division EZRT, Flugplatzstraße 75, 90768 Fürth / Josef-Martin-Weg 63, 97074 Würzburg, Germany
| | | | | | | |
Collapse
|
7
|
Shi Z, Jefimovs K, Romano L, Stampanoni M. Towards the Fabrication of High-Aspect-Ratio Silicon Gratings by Deep Reactive Ion Etching. MICROMACHINES 2020; 11:E864. [PMID: 32961900 PMCID: PMC7570153 DOI: 10.3390/mi11090864] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 09/10/2020] [Accepted: 09/17/2020] [Indexed: 01/02/2023]
Abstract
The key optical components of X-ray grating interferometry are gratings, whose profile requirements play the most critical role in acquiring high quality images. The difficulty of etching grating lines with high aspect ratios when the pitch is in the range of a few micrometers has greatly limited imaging applications based on X-ray grating interferometry. A high etching rate with low aspect ratio dependence is crucial for higher X-ray energy applications and good profile control by deep reactive ion etching of grating patterns. To achieve this goal, a modified Coburn-Winters model was applied in order to study the influence of key etching parameters, such as chamber pressure and etching power. The recipe for deep reactive ion etching was carefully fine-tuned based on the experimental results. Silicon gratings with an area of 70 × 70 mm2, pitch size of 1.2 and 2 μm were fabricated using the optimized process with aspect ratio α of ~67 and 77, respectively.
Collapse
Affiliation(s)
- Zhitian Shi
- Paul Scherrer Institut, 5232 Villigen PSI, Switzerland; (K.J.); (L.R.); (M.S.)
- Department of Information Technology and Electrical Engineering, ETH Zürich, 8092 Zürich, Switzerland
| | - Konstantins Jefimovs
- Paul Scherrer Institut, 5232 Villigen PSI, Switzerland; (K.J.); (L.R.); (M.S.)
- Department of Information Technology and Electrical Engineering, ETH Zürich, 8092 Zürich, Switzerland
| | - Lucia Romano
- Paul Scherrer Institut, 5232 Villigen PSI, Switzerland; (K.J.); (L.R.); (M.S.)
- Department of Information Technology and Electrical Engineering, ETH Zürich, 8092 Zürich, Switzerland
- Department of Physics and CNR-IMM-University of Catania, 64 via S. Sofia, 95123 Catania, Italy
| | - Marco Stampanoni
- Paul Scherrer Institut, 5232 Villigen PSI, Switzerland; (K.J.); (L.R.); (M.S.)
- Department of Information Technology and Electrical Engineering, ETH Zürich, 8092 Zürich, Switzerland
| |
Collapse
|
8
|
Abstract
The X-ray dark-field signal can be measured with a grating-based Talbot-Lau interferometer. It measures small angle scattering of micrometer-sized oriented structures. Interestingly, the signal is a function not only of the material, but also of the relative orientation of the sample, the X-ray beam direction, and the direction of the interferometer sensitivity. This property is very interesting for potential tomographically reconstructing structures below the imaging resolution. However, tomographic reconstruction itself is a substantial challenge. A key step of the reconstruction algorithm is the inversion of a forward projection model. In this work, we propose a very general 3-D projection model. We derive the projection model under the assumption that the observed scatter distribution has a Gaussian shape. We theoretically show the consistency of our model with existing, more constrained 2-D models. Furthermore, we experimentally show the compatibility of our model with simulations and real dark-field measurements. We believe that this 3-D projection model is an important step towards more flexible trajectories and, by extension, dark-field imaging protocols that are much better applicable in practice.
Collapse
|
9
|
Gustschin N, Gustschin A, Meyer P, Viermetz M, Riederer P, Herzen J, Mohr J, Pfeiffer F. Quality and parameter control of X-ray absorption gratings by angular X-ray transmission. OPTICS EXPRESS 2019; 27:15943-15955. [PMID: 31163783 DOI: 10.1364/oe.27.015943] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2018] [Accepted: 02/17/2019] [Indexed: 06/09/2023]
Abstract
Here we report on a non-destructive, spatially resolving and easy to implement quality and parameter control method for high aspect ratio X-ray absorption gratings. Based on angular X-ray transmission measurements, our proposed technique allows to determine the duty cycle, the transmittance, the height, as well as the local inclination of the absorbing grating structures. A key advantage of the presented method is a fast and extensive grating quality evaluation without the need of implementing an entire grating interferometer. In addition to the local and surface-based analysis using a scanning electron microscope, our non-destructive method provides global averaged macroscopic and spatially resolved grating structure information without the requirement of resolving individual grating lines.
Collapse
|
10
|
Ludwig V, Seifert M, Hauke C, Hellbach K, Horn F, Pelzer G, Radicke M, Rieger J, Sutter SM, Michel T, Anton G. Exploration of different x-ray Talbot-Lau setups for dark-field lung imaging examined in a porcine lung. Phys Med Biol 2019; 64:065013. [PMID: 30731447 DOI: 10.1088/1361-6560/ab051c] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
X-ray dark-field imaging is a promising technique for lung diagnosis. Due to the alveolar structure of lung tissue, a higher contrast is obtained by the dark-field image compared to the attenuation image. Animal studies indicate an enhancement regarding the detection of lung diseases in early stages. In this publication, we focus on the influence of different Talbot-Lau interferometer specifications while maintaining the x-ray source, sample magnification and detector system. By imaging the same porcine lung with three different grating sets, we analyze the contrast-to-noise ratio of the obtained dark-field images with respect to visibility and correlation length. We demonstrate that relatively large grating periods of the phase and of the analyzer grating are sufficient for high quality lung imaging at reasonable dose levels.
Collapse
Affiliation(s)
- Veronika Ludwig
- Erlangen Centre for Astroparticle Physics, Friedrich-Alexander-University Erlangen-Nuremberg, 91058 Erlangen, Germany
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Talbot-Lau x-ray phase-contrast setup for fast scanning of large samples. Sci Rep 2019; 9:4199. [PMID: 30862865 PMCID: PMC6414610 DOI: 10.1038/s41598-018-38030-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 12/10/2018] [Indexed: 02/07/2023] Open
Abstract
Compared to conventional attenuation x-ray radiographic imaging, the x-ray Talbot-Lau technique provides further information about the scattering and the refractive properties of the object in the beam path. Hence, this additional information should improve the diagnostic process concerning medical applications and non-destructive testing. Nevertheless, until now, due to grating fabrication process, Talbot-Lau imaging suffers from small grating sizes (70 mm diameter). This leads to long acquisition times for imaging large objects. Stitching the gratings is one solution. Another one consists of scanning Talbot-Lau setups. In this publication, we present a compact and very fast scanning setup which enables imaging of large samples. With this setup a maximal scanning velocity of 71.7 mm/s is possible. A resolution of 4.1 lines/mm can be achieved. No complex alignment procedures are necessary while the field of view comprises 17.5 × 150 cm2. An improved reconstruction algorithm concerning the scanning approach, which increases robustness with respect to mechanical instabilities, has been developed and is presented. The resolution of the setup in dependence of the scanning velocity is evaluated. The setup imaging qualities are demonstrated using a human knee ex-vivo as an example for a high absorbing human sample.
Collapse
|
12
|
Stromer D, Christlein V, Huang X, Zippert P, Hausotte T, Maier A. Virtual cleaning and unwrapping of non-invasively digitized soiled bamboo scrolls. Sci Rep 2019; 9:2311. [PMID: 30783154 PMCID: PMC6381128 DOI: 10.1038/s41598-019-39447-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2018] [Accepted: 01/24/2019] [Indexed: 11/12/2022] Open
Abstract
In ancient China, symbols and drawings captured on bamboo and wooden slips were used as main communication media. Those documents are very precious for cultural heritage and research, but due to aging processes, the discovered pieces are sometimes in a poor condition and contaminated by soil. Manual cleaning of excavated slips is a demanding and time-consuming task in which writings can be accidentally deleted. To counter this, we propose a novel approach based on conventional 3-D X-ray computed tomography to digitize such historical documents without before manual cleaning. By applying a virtual cleaning and unwrapping algorithm, the entire scroll surface is remapped into 2-D such that the hidden content becomes readable. We show that the technique also works for heavily soiled scrolls, enabling an investigation of the content by the naked eye without the need for manual labor. This digitization also allows for recovery of potentially erased writings and reconstruction of the original spatial information.
Collapse
Affiliation(s)
- Daniel Stromer
- Pattern Recognition Lab, Computer Science, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, 91058, Germany.
| | - Vincent Christlein
- Pattern Recognition Lab, Computer Science, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, 91058, Germany
| | - Xiaolin Huang
- Institute of Image Processing and Pattern Recognition, Shanghai Jiao Tong University, Shanghai, 200240, P.R. China
| | - Patrick Zippert
- Institute of Manufacturing Metrology, Mechanical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, 91052, Germany
| | - Tino Hausotte
- Institute of Manufacturing Metrology, Mechanical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, 91052, Germany
| | - Andreas Maier
- Pattern Recognition Lab, Computer Science, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, 91058, Germany
| |
Collapse
|
13
|
Browsing through sealed historical manuscripts by using 3-D computed tomography with low-brilliance X-ray sources. Sci Rep 2018; 8:15335. [PMID: 30337644 PMCID: PMC6194115 DOI: 10.1038/s41598-018-33685-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Accepted: 10/03/2018] [Indexed: 12/04/2022] Open
Abstract
Severely damaged historical documents are extremely fragile. In many cases, their secrets remain concealed beneath their cover. Recently, non-invasive digitization approaches based on 3-D scanning have demonstrated the ability to recover single pages or letters without the need to open the manuscripts. This can even be achieved using conventional micro-CTs without the need for synchrotron hardware. However, not all manuscripts may be suited for such techniques due to their material and X-ray properties. In order to recommend which manuscripts and which inks are best suited for such a process, we investigate six inks that were commonly used in ancient times: malachite, three types of iron gall, Tyrian purple, and buckthorn. Image contrast is explored over the complete pipeline, from the X-ray CT scan and page extraction to the virtual flattening of the page image. We demonstrate, that all inks containing metallic particles are visible in the output, a decrease of the X-ray energy enhances the readability, and that the visibility highly depends on the X-ray attenuation of the ink’s metallic ingredients and their concentration. Based on these observations, we give recommendations on how to select the appropriate imaging parameters.
Collapse
|
14
|
Phase-Contrast and Dark-Field Imaging. J Imaging 2018. [DOI: 10.3390/jimaging4100113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Very early, in 1896, Wilhelm Conrad Röntgen, the founding father of X-rays, attempted to measure diffraction and refraction by this new kind of radiation, in vain. Only 70 years later, these effects were measured by Ulrich Bonse and Michael Hart who used them to make full-field images of biological specimen, coining the term phase-contrast imaging. Yet, another 30 years passed until the Talbot effect was rediscovered for X-radiation, giving rise to a micrograting based interferometer, replacing the Bonse–Hart interferometer, which relied on a set of four Laue-crystals for beam splitting and interference. By merging the Lau-interferometer with this Talbot-interferometer, another ten years later, measuring X-ray refraction and X-ray scattering full-field and in cm-sized objects (as Röntgen had attempted 110 years earlier) became feasible in every X-ray laboratory around the world. Today, now that another twelve years have passed and we are approaching the 125th jubilee of Röntgen’s discovery, neither Laue-crystals nor microgratings are a necessity for sensing refraction and scattering by X-rays. Cardboard, steel wool, and sandpaper are sufficient for extracting these contrasts from transmission images, using the latest image reconstruction algorithms. This advancement and the ever rising number of applications for phase-contrast and dark-field imaging prove to what degree our understanding of imaging physics as well as signal processing have advanced since the advent of X-ray physics, in particular during the past two decades. The discovery of the electron, as well as the development of electron imaging technology, has accompanied X-ray physics closely along its path, both modalities exploring the applications of new dark-field contrast mechanisms these days. Materials science, life science, archeology, non-destructive testing, and medicine are the key faculties which have already integrated these new imaging devices, using their contrast mechanisms in full. This special issue “Phase-Contrast and Dark-field Imaging” gives us a broad yet very to-the-point glimpse of research and development which are currently taking place in this very active field. We find reviews, applications reports, and methodological papers of very high quality from various groups, most of which operate X-ray scanners which comprise these new imaging modalities.
Collapse
|