1
|
Lee CH, Lee SH, Kwak HS, Kwak YG, Rosenson RS, Cho YI, Jeong SK. Validation of Signal Intensity Gradient from TOF-MRA for Wall Shear Stress by Phase-Contrast MR. JOURNAL OF IMAGING INFORMATICS IN MEDICINE 2024; 37:1248-1258. [PMID: 38332403 PMCID: PMC11169296 DOI: 10.1007/s10278-024-00991-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 11/30/2023] [Accepted: 12/13/2023] [Indexed: 02/10/2024]
Abstract
To validate the correlation between the signal intensity gradient (SIG) from time-of-flight magnetic resonance angiography (TOF-MRA) and wall shear stress (WSS) determined by phase contrast magnetic resonance (PC-MR), we conducted both experimental and human studies. In the experimental study, we measured WSS in four tubes of different sizes with variable flow rates using PC-MR and TOF-MRA. The flow rates of water in the experimental study ranged from 0.06 to 12.75 mL/s, resulting in PC-WSS values between 0.1 and 1.6 dyne/cm2. The correlation between PC-WSS and SIG was statistically significant, showing a coefficient of 0.86 (P < 0.001, R2 = 0.75). The line fit provided the conversion equation as Y = 1.6287X - 1.1563 (Y = PC-WSS, X = SIG). For the human study, 28 subjects underwent TOF-MRA and PC-MR examinations of carotid and vertebral arteries. Arterial PC-WSS and SIG were determined in the same segment for each subject. The arterial PC-WSS ranged from 1.9 to 21.0 dyne/cm2. Both carotid and vertebral arteries showed significant correlations between PC-WSS and SIG, with coefficients of 0.85, 0.86, 0.91, and 0.81 in the right and left carotid and vertebral arteries, respectively. Our results show that SIG from TOF-MRA and SIG-WSS derived from the conversion equation provide concurrent in vivo hemodynamic information on arterial shear stress. This study was registered on ClinicalTrials.gov with the identifier NCT04585971 on October 14, 2020.
Collapse
Affiliation(s)
- Chan-Hyuk Lee
- Department of Neurology, Asan Medical Center, Seoul, Republic of Korea
- Department of Neurology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, Republic of Korea
| | - Sang Hyuk Lee
- Equipment Qualification Center for Nuclear Power Plants, Korea Institute of Machinery and Materials, Daejeon, Republic of Korea
| | - Hyo-Sung Kwak
- Department of Radiology and Research Institute of Clinical Medicine of Jeonbuk National University, Biomedical Research Institute of Jeonbuk National University Hospital, Jeonju, Republic of Korea
| | - Yeong-Gon Kwak
- Department of Radiotechnology, Wonkwang Health Science University, Iksan, Republic of Korea
| | - Robert S Rosenson
- Mount Sinai Heart, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Young I Cho
- Department of Mechanical Engineering and Mechanics, Drexel University, Philadelphia, PA, USA
| | - Seul-Ki Jeong
- Seul-Ki Jeong Neurology Clinic, 233, Gucheonmyeon-ro, Gangdong-gu, Seoul, 05326, Republic of Korea.
| |
Collapse
|
2
|
El Sayed R, Lucas CJ, Cebull HL, Nahab FB, Haussen DC, Allen JW, Oshinski JN. Subjects with carotid webs demonstrate pro-thrombotic hemodynamics compared to subjects with carotid atherosclerosis. Sci Rep 2024; 14:10092. [PMID: 38698141 PMCID: PMC11066020 DOI: 10.1038/s41598-024-60666-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Accepted: 04/25/2024] [Indexed: 05/05/2024] Open
Abstract
Carotid artery webs (CaW) are non-atherosclerotic projections into the vascular lumen and have been linked to up to one-third of cryptogenic strokes in younger patients. Determining how CaW affects local hemodynamics is essential for understanding clot formation and stroke risk. Computational fluid dynamics simulations were used to investigate patient-specific hemodynamics in carotid artery bifurcations with CaW, bifurcations with atherosclerotic lesions having a similar degree of lumen narrowing, and with healthy carotid bifurcations. Simulations were conducted using segmented computed tomography angiography geometries with inlet boundary conditions extracted from 2D phase contrast MRI scans. The study included carotid bifurcations with CaW (n = 13), mild atherosclerosis (n = 7), and healthy bifurcation geometries (n = 6). Hemodynamic parameters associated with vascular dysfunction and clot formation, including shear rate, oscillatory shear index (OSI), low velocity, and flow stasis were calculated and compared between the subject groups. Patients with CaW had significantly larger regions containing low shear rate, high OSI, low velocity, and flow stasis in comparison to subjects with mild atherosclerosis or normal bifurcations. These abnormal hemodynamic metrics in patients with CaW are associated with clot formation and vascular dysfunction and suggest that hemodynamic assessment may be a tool to assess stroke risk in these patients.
Collapse
Affiliation(s)
- Retta El Sayed
- Department of Biomedical Engineering, Georgia Institute of Technology, Emory University, 1364 Clifton Rd, Atlanta, GA, 30322, USA
- Department of Radiology and Imaging Sciences, Emory University, Atlanta, GA, USA
| | - Carissa J Lucas
- Department of Biomedical Engineering, Georgia Institute of Technology, Emory University, 1364 Clifton Rd, Atlanta, GA, 30322, USA
| | - Hannah L Cebull
- Department of Radiology and Imaging Sciences, Emory University, Atlanta, GA, USA
| | - Fadi B Nahab
- Department of Neurology, Emory University, Atlanta, GA, USA
| | | | - Jason W Allen
- Department of Radiology and Imaging Sciences, Indiana University, Indianapolis, IN, USA
| | - John N Oshinski
- Department of Biomedical Engineering, Georgia Institute of Technology, Emory University, 1364 Clifton Rd, Atlanta, GA, 30322, USA.
- Department of Radiology and Imaging Sciences, Emory University, Atlanta, GA, USA.
| |
Collapse
|
3
|
Corti M, Zingaro A, Dede' L, Quarteroni AM. Impact of atrial fibrillation on left atrium haemodynamics: A computational fluid dynamics study. Comput Biol Med 2022; 150:106143. [PMID: 36182758 DOI: 10.1016/j.compbiomed.2022.106143] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 08/30/2022] [Accepted: 09/18/2022] [Indexed: 11/28/2022]
Abstract
We analyse the haemodynamics of the left atrium, highlighting differences between healthy individuals and patients affected by atrial fibrillation. The computational study is based on patient-specific geometries of the left atria to simulate blood flow dynamics. We design a novel procedure to compute the boundary data for the 3D haemodynamic simulations, which are particularly useful in absence of data from clinical measurements. With this aim, we introduce a parametric definition of atrial displacement, and we use a closed-loop lumped parameter model of the whole cardiovascular circulation conveniently tuned on the basis of the patient's characteristics. We evaluate several fluid dynamics indicators for atrial haemodynamics, validating our numerical results in terms of clinical measurements; we investigate the impact of geometric and clinical characteristics on the risk of thrombosis. To highlight the correlation of thrombus formation with atrial fibrillation, according to medical evidence, we propose a novel indicator: age stasis. It arises from the combination of Eulerian and Lagrangian quantities. This indicator identifies regions where slow flow cannot properly rinse the chamber, accumulating stale blood particles, and creating optimal conditions for clots formation.
Collapse
Affiliation(s)
- Mattia Corti
- MOX-Dipartimento di Matematica, Politecnico di Milano, Piazza Leonardo da Vinci 32, Milan, 20133, Italy.
| | - Alberto Zingaro
- MOX-Dipartimento di Matematica, Politecnico di Milano, Piazza Leonardo da Vinci 32, Milan, 20133, Italy
| | - Luca Dede'
- MOX-Dipartimento di Matematica, Politecnico di Milano, Piazza Leonardo da Vinci 32, Milan, 20133, Italy
| | - Alfio Maria Quarteroni
- MOX-Dipartimento di Matematica, Politecnico di Milano, Piazza Leonardo da Vinci 32, Milan, 20133, Italy; Institute of Mathematics, École Polytechnique Fédérale de Lausanne, Station 8, Av. Piccard, Lausanne, CH-1015, Switzerland (Professor Emeritus)
| |
Collapse
|
4
|
Shields A, Setlur Nagesh SV, Chivukula V, Ionita C, Bednarek DR, Rudin S. Derivation of vascular wall shear stress from 1000 fps high-speed angiography (HSA) velocity distributions. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2022; 12036:120360C. [PMID: 36034106 PMCID: PMC9407022 DOI: 10.1117/12.2611175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Pathological changes in blood flow lead to altered hemodynamic forces, which are responsible for a number of conditions related to the remodeling and regeneration of the vasculature. More specifically, wall shear stress (WSS) has been shown to be a significant hemodynamic parameter with respect to aneurysm growth and rupture, as well as plaque activation leading to increased risk of stroke. In-vivo measurement of shear stress is difficult due to the stringent requirements on spatial resolution near the wall boundaries, as well as the deviation from the commonly assumed parabolic flow behavior at the wall. In this work, we propose an experimental method of in-vitro WSS calculations from high-temporal resolution velocity distributions, which are derived from 1000 fps high-speed angiography (HSA). The high-spatial and temporal resolution of our HSA detector makes such high-resolution velocity gradient measurements feasible. Presented here is the methodology for calculation of WSS in the imaging plane, as well as initial results for a variety of vascular geometries at physiologically realistic flow rates. Further, the effect of spatial resolution on the gradient calculation is explored using CFD-derived velocity data. Such angiographic-based analysis with HSA has the potential to provide critical hemodynamic feedback in an interventional setting, with the overarching objective of supporting clinical decision-making and improving patient outcomes.
Collapse
Affiliation(s)
- A Shields
- Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY
| | - S V Setlur Nagesh
- Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY
| | - V Chivukula
- Department of Biomedical Engineering, Florida Institute of Technology, Melbourne, FL
| | - C Ionita
- Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY
| | - D R Bednarek
- Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY
| | - S Rudin
- Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY
| |
Collapse
|
5
|
Lim SH, Mohd Adib MAH, Abdullah MS, Mohd Taib NH, Hassan R, Abd Aziz A. Investigate the Velocity Difference Between MRI Measurement and CFD Simulation on Patient-Specific Blood Flow Analysis. 6TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2021 2022:453-460. [DOI: 10.1007/978-3-030-90724-2_49] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
6
|
Ngo MT, Lee UY, Ha H, Jung J, Lee DH, Kwak HS. Improving Blood Flow Visualization of Recirculation Regions at Carotid Bulb in 4D Flow MRI Using Semi-Automatic Segmentation with ITK-SNAP. Diagnostics (Basel) 2021; 11:diagnostics11101890. [PMID: 34679588 PMCID: PMC8534781 DOI: 10.3390/diagnostics11101890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 10/06/2021] [Accepted: 10/10/2021] [Indexed: 11/16/2022] Open
Abstract
Assessment of carotid bulb hemodynamics using four-dimensional (4D) flow magnetic resonance imaging (MRI) requires accurate segmentation of recirculation regions that is frequently hampered by limited resolution. This study aims to improve the accuracy of 4D flow MRI carotid bulb segmentation and subsequent recirculation regions analysis. Time-of-flight (TOF) MRI and 4D flow MRI were performed on bilateral carotid artery bifurcations in seven healthy volunteers. TOF-MRI data was segmented into 3D geometry for computational fluid dynamics (CFD) simulations. ITK-SNAP segmentation software was included in the workflow for the semi-automatic generation of 4D flow MRI angiographic data. This study compared the velocities calculated at the carotid bifurcations and the 3D blood flow visualization at the carotid bulbs obtained by 4D flow MRI and CFD. By applying ITK-SNAP segmentation software, an obvious improvement in the 4D flow MRI visualization of the recirculation regions was observed. The 4D flow MRI images of the recirculation flow characteristics of the carotid artery bulbs coincided with the CFD. A reasonable agreement was found in terms of velocity calculated at the carotid bifurcation between CFD and 4D flow MRI. However, the dispersion of velocity data points relative to the local errors of measurement in 4D flow MRI remains. Our proposed strategy showed the feasibility of improving recirculation regions segmentation and the potential for reliable blood flow visualization in 4D flow MRI. However, quantitative analysis of recirculation regions in 4D flow MRI with ITK-SNAP should be enhanced for use in clinical situations.
Collapse
Affiliation(s)
- Minh Tri Ngo
- Department of Radiology of Hue Central Hospital, Hue, Thua Thien Hue 530000, Vietnam;
| | - Ui Yun Lee
- Division of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeon-ju 54896, Korea; (U.Y.L.); (J.J.)
| | - Hojin Ha
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon 24341, Korea;
| | - Jinmu Jung
- Division of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeon-ju 54896, Korea; (U.Y.L.); (J.J.)
- Hemorheology Research Institute, Jeonbuk National University, Jeon-ju 54896, Korea
| | - Dong Hwan Lee
- Division of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeon-ju 54896, Korea; (U.Y.L.); (J.J.)
- Hemorheology Research Institute, Jeonbuk National University, Jeon-ju 54896, Korea
- Correspondence: (D.H.L.); (H.S.K.); Tel.: +82-63-270-3998 (D.H.L.); +82-63-250-2582 (H.S.K.)
| | - Hyo Sung Kwak
- Department of Radiology and Research Institute of Clinical Medicine of Jeonbuk National University, Biomedical Research Institute of Jeonbuk National University Hospital, Jeon-ju 54907, Korea
- Correspondence: (D.H.L.); (H.S.K.); Tel.: +82-63-270-3998 (D.H.L.); +82-63-250-2582 (H.S.K.)
| |
Collapse
|