1
|
Lup VM, Malvicini G, Gaeta C, Grandini S, Ciavoi G. Glide Path in Endodontics: A Literature Review of Current Knowledge. Dent J (Basel) 2024; 12:257. [PMID: 39195101 DOI: 10.3390/dj12080257] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2024] [Revised: 08/09/2024] [Accepted: 08/13/2024] [Indexed: 08/29/2024] Open
Abstract
The introduction of nickel-titanium rotary instruments revolutionized shaping procedures as they were able to produce a well-tapered preparation while reducing operator fatigue. The major drawback of rotary instruments was the high risk of fracture due to bending and torsional stress. Thus, the creation of a glide path has been advocated and recommended by most rotary instrument manufacturers. The aim of the present review is to summarize existing knowledge on glide path preparation and identify areas where further research is needed. The primary goal is to provide a comprehensive overview of the techniques and instruments used in glide path preparation, highlighting their advantages and limitations. The secondary goal is to explore the effect of glide path creation on the overall success of endodontic treatment, particularly in terms of reducing procedural errors and improving treatment outcomes. An online search on PubMed, ScienceDirect, UCLA, and Scopus databases was conducted, and 116 articles were identified. Eligible articles were divided into nine categories based on what they researched and compared. The categories included centering ability and/or root canal transportation, cyclic fatigue resistance, glide path and shaping time, tortional stress resistance, apical extrusion of debris and/or bacteria, defects in dentine walls, file separation, postoperative pain assessment, and scouting ability and performance. Establishing a glide path reduces root canal transportation, especially with rotary methods. Reciprocating and heat-treated files offer higher fatigue resistance and shorter preparation time. Instruments with shorter pitch lengths have greater torsional strength. Preparation and coronal preflaring reduce apical debris and bacteria. Glide paths do not affect dentine microcracks, file separation, or defects but reduce immediate postoperative pain and improve cutting ability. Randomized trials are needed to assess their impact on treatment outcomes.
Collapse
Affiliation(s)
- Vlad Mircea Lup
- Doctoral School of Biomedical Sciences, University of Oradea, 410 087 Oradea, Romania
| | - Giulia Malvicini
- Unit of Endodontics and Restorative Dentistry, Department of Medical Biotechnologies, University of Siena, 53100 Siena, Italy
| | - Carlo Gaeta
- Unit of Endodontics and Restorative Dentistry, Department of Medical Biotechnologies, University of Siena, 53100 Siena, Italy
| | - Simone Grandini
- Unit of Endodontics and Restorative Dentistry, Department of Medical Biotechnologies, University of Siena, 53100 Siena, Italy
| | - Gabriela Ciavoi
- Faculty of Medicine and Pharmacy, University of Oradea, 410 087 Oradea, Romania
| |
Collapse
|
2
|
Torsional Fracture Resistance of Niti Rotary Glide Path Files under Flexural Stress. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12126214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
This study aimed to evaluate the effects of flexural stress on the torsional fracture resistance of NiTi glide path files. PathFile #16/02, RaCe #15/04, RaCe Evo #15/04, HyFlex EDM #15/03, TruNatomy Glider #17/02, and V Taper 2H #17/04 were examined by scanning electron microscopy (SEM) (n = 3/brand) and subjected to differential scanning calorimetry (n = 2/brand). Torsional fracture resistance testing was performed in straight (ISO 3630-1) and flexural modes (n = 15/brand/mode). Flexural mode testing involved instruments rotating within a stainless-steel artificial double-curved canal. Ultimate strength and distortion angle until failure were recorded, and fractured instruments were examined by SEM. Statistical analyses involved independent sample t-test and one-way analysis of variance with Games–Howell pots hoc test. Austenitic transformation- finishing temperatures of heat-treated files were above body temperature. For RaCe Evo, HyFlex EDM, TruNatomy Glider, and V Taper 2H, the flexural mode resulted in a significantly higher distortion angle compared to the straight mode (p < 0.05). The maximum torque of RaCe Evo, HyFlex EDM increased with the flexural stress (p < 0.05). V taper 2H showed the highest distortion angle and ultimate strength. SEM showed typical patterns of torsional fracture for all tested files. The flexural stress positively affected distortion angle of heat-treated NiTi glide path files.
Collapse
|
3
|
Analysis of Torque and Force Induced by Rotary Nickel-Titanium Instruments during Root Canal Preparation: A Systematic Review. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11073079] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
The aim of this review was to provide a detailed literature analysis of torque and force generation during nickel-titanium rotary root canal instrumentation. We followed Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. An electronic search was performed using in PubMed and in journals for articles published in English from 1987 to June 2020 on studies that investigated dynamic torque and force in vivo or in vitro. We assessed article titles and abstracts to remove duplicates, and the titles and abstracts of the remaining articles were screened for eligibility. Full texts were read to verify eligibility by considering predetermined inclusion and exclusion criteria. Fifty-two out of 4096 studies met the inclusion criteria, from which we identified 26 factors that influence torque or force generation. Factors associated with higher torque or force generation and supported by multiple studies with mostly consistent results included convex triangle cross-sectional design, regressive taper, short pitch length, large instrument size, small canal size, single-length preparation technique, long preparation time, deep insertion depth, low rate of insertion, continuous rotation (torque), reciprocating motion (force), lower rotational speed and conventional alloy. However, several factors are interrelated, which obscured the independent effect of each factor, and there was insufficient scientific evidence supporting the influence of some factors.
Collapse
|
4
|
Campos DS, Rodrigues EA, Bueno CEDS, Fontana CE, da Silva EJNL, de Lima CO, De Martin AS. The ability of reciprocating glide path instruments to reach the full root canal working length. AUST ENDOD J 2021; 47:487-492. [PMID: 33754413 DOI: 10.1111/aej.12510] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/07/2021] [Indexed: 11/30/2022]
Abstract
This study evaluated the ability of reciprocating glide path instruments to reach the full working length (RFWL). Thirty mesial roots of mandibular molars were matched into 2 groups (n = 15 teeth, 30 root canals), according to the system used for glide path: WaveOne Gold Glider (WOGG) and R-Pilot. The samples with fractured instruments or when it was not possible to RFWL were scanned using micro-computed tomography. Fractured instruments were also visualised through a scanning electron microscopy to verify the type of fracture. The parameters were compared statistically by Fisher's and chi-square tests (P < 0.05). No instrument fractures were observed in the R-pilot, while 2 fractures occurred in the WOGG group (P > 0.05). RFLW was achieved in 29 canals (96.66%) and 28 canals (93.33%) with R-pilot and WOGG instruments, respectively (P > 0.05). The instruments are able to RFWL in mesial canals of mandibular molars. WOGG showed two fractures while no R-Pilot instruments fractured.
Collapse
Affiliation(s)
- Daniel Souza Campos
- Department of Endodontics, School of Dentistry, São Leopoldo Mandic Faculty, Campinas, Brazil
| | - Evaldo Almeida Rodrigues
- Department of Endodontics, School of Dentistry, State University of Feira de Santana (UEFS), Feira de Santana, Brazil
| | | | - Carlos Eduardo Fontana
- Department of Endodontics, School of Dentistry, São Leopoldo Mandic Faculty, Campinas, Brazil
| | - Emmanuel João Nogueira Leal da Silva
- Department of Endodontics, School of Dentistry, State University of Rio de Janeiro (UERJ), Rio de Janeiro, Brazil.,Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - Carolina Oliveira de Lima
- Department of Endodontics, School of Dentistry, State University of Rio de Janeiro (UERJ), Rio de Janeiro, Brazil
| | | |
Collapse
|
5
|
Seracchiani M, Miccoli G, Di Nardo D, Zanza A, Cantore M, Gambarini G, Testarelli L. Effect of Flexural Stress on Torsional Resistance of NiTi Instruments. J Endod 2020; 47:472-476. [PMID: 33096192 DOI: 10.1016/j.joen.2020.10.011] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Revised: 09/27/2020] [Accepted: 10/15/2020] [Indexed: 11/16/2022]
Abstract
INTRODUCTION Previously published studies have deeply investigated the characteristics of flexural and torsional resistance of nickel-titanium rotary instruments, but none of them investigated the relationship between the 2 stresses. The objective of the present study was to evaluate the influence of flexural stresses over torsional resistance. METHODS Sixty S-One 20.04 files (Fanta Dental, Shanghai, China) were used in the present study (N = 60) and divided into 3 test groups of 20 files. A customized device made of a mobile structure with a connection that holds the handpiece and the artificial canal was used for the experiment to make the measurements repeatable. The artificial canals were created with a 90° curvature, a 60° curvature, and lastly a straight canal. Each file was rotated at 300 rpm with a maximum torque value of 5.5 Ncm with the apical 2 mm firmly secured in a vise. The torque at fracture and the time to fracture were recorded by the software integrated in the handpiece and evaluated through statistical analysis. RESULTS Statistical analysis found significant differences in the values of torque to fracture (TtF) between these 3 groups (P < .05). The 90° curved canal group showed the highest TtF value, and the 60° curved canal group showed a higher TtF value than the straight canal group. CONCLUSIONS The results of the present study demonstrated a positive influence of flexural stresses over torque at fracture of rotary files. When nickel-titanium instruments were used in a 90° or 60° curvature, the values of torque at fracture increased compared with the same instruments that rotated in the straight canal.
Collapse
Affiliation(s)
- Marco Seracchiani
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Gabriele Miccoli
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Dario Di Nardo
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy.
| | - Alessio Zanza
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Marco Cantore
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Gianluca Gambarini
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Luca Testarelli
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
6
|
Cunha TC, Matos FDS, Paranhos LR, Bernardino ÍDM, Moura CCG. Influence of glide path kinematics during endodontic treatment on the occurrence and intensity of intraoperative and postoperative pain: a systematic review of randomized clinical trials. BMC Oral Health 2020; 20:175. [PMID: 32571285 PMCID: PMC7310418 DOI: 10.1186/s12903-020-01164-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Accepted: 06/12/2020] [Indexed: 01/14/2023] Open
Abstract
BACKGROUND Preliminary canal enlargement (glide path preparation) may play a significant role in the development of pain. The aim of this systematic review of randomized clinical trials was to assess the influence of glide path kinematics during endodontic treatment on the occurrence and intensity of intraoperative and postoperative pain. METHODS A search was performed in June 2019 in six electronic databases (PubMed, Scopus, LILACS, SciELO, Embase and Web of Science) and two grey literature databases (OpenGrey and OpenThesis). The bibliographic references of the eligible articles were also hand-searched. The included clinical studies assessed the occurrence and intensity of intraoperative and/or postoperative pain after root canal preparation without glide path preparation (WGP) or with glide path preparation using manual (M-GP), continuous rotary (CR-GP), or reciprocating (R-GP) instruments. The primary outcome was the occurrence and intensity of intraoperative and postoperative pain, while analgesic consumption was the secondary outcome. The full texts of the eligible studies were analyzed by two reviewers who performed calibration exercises to verify the risk of bias and quality of the individual studies using the Joanna Briggs Institute Critical Appraisal tool. RESULTS From 1283 identified articles, only six studies were included in the qualitative analysis of the results, with a total sample of 884 patients/teeth. Three studies presented a high risk of bias, while three studies presented a moderate risk. Two studies reported that CR-GP causes lower pain levels than M-GP and WGP, and three studies showed no differences between CR-GP and R-GP. Regarding analgesic consumption, two studies found no differences among glide path kinematics, and one study reported lower consumption for CR-GP than for M-GP. Because of the limited number of studies and methodological differences, no statistical analyses were performed for the glide path kinematics comparisons. CONCLUSIONS Compelling evidence indicating a significantly different occurrence and intensity of pain among glide path kinematics is lacking. The systematic review protocol was registered in the PROSPERO database [CRD42020139989].
Collapse
Affiliation(s)
- Thaís Christina Cunha
- Postgraduate Program in Dentistry, School of Dentistry, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | - Felipe de Souza Matos
- Postgraduate Program in Dentistry, School of Dentistry, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | - Luiz Renato Paranhos
- Department of Preventive and Community Dentistry, School of Dentistry, Federal University of Uberlândia, Av. Pará, 1720, Bloco 2G, sala 1, Umuarama, Uberlândia, MG, CEP 38405-320, Brazil.
| | | | | |
Collapse
|