1
|
Abounassif FM, Alfaraj A, Gadah T, Yang CC, Chu TMG, Lin WS. Color stability of precolored and extrinsically colored monolithic multilayered polychromatic zirconia: Effects of surface finishing and aging. J Prosthodont 2024. [PMID: 38923252 DOI: 10.1111/jopr.13875] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Accepted: 05/13/2024] [Indexed: 06/28/2024] Open
Abstract
PURPOSE To explore the impact of zirconia types, coloring methods, and surface finishing on the color stability of monolithic multilayered polychromatic zirconia after artificial aging, including thermocycling and simulated toothbrushing. MATERIALS AND METHODS Eighty square-shaped zirconia samples were divided into 2 types (M3Y-TZP and M6Y-PSZ), further categorized based on coloring methods (precolored and extrinsically colored) and surface finishing techniques (mechanical polishing or glazing). The color stability was assessed using the CIEDE2000 formula. Artificial aging was simulated via thermocycling and toothbrushing. All samples were analyzed with a spectrophotometer to determine the post-aging color changes (ΔE00). The ΔE00 were interpreted and classified using the 50:50% perceptibility threshold (PT) and the 50:50% acceptability threshold (AT). Comparisons between groups for ΔE00 differences were performed using three-way ANOVA, with pairwise comparisons facilitated by Fisher's protected least significant difference test, α = 0.05. RESULTS The study results indicated significant impacts of zirconia type, coloring method, and surface finishing on color stability. The M6Y groups experienced significantly greater color changes (6.61 ± 1.63) compared to the M3Y groups (3.40 ± 2.24), p < 0.0001. For both types of zirconia, extrinsically colored samples exhibited significantly higher ΔE00 when mechanically polished (p = 0.004). However, surface finishing had no significant effect on ΔE00 in precolored samples of either zirconia material (p = 1.000). The evaluation and categorization of ΔE00 variations indicated that nearly all color changes in the M6Y groups, regardless of being precolored, extrinsically colored, polished, or glazed, were deemed extremely unacceptable (Grade 1). In contrast, the M3Y groups showed more acceptable results, with the majority of color changes classified as moderately unacceptable (Grade 3). CONCLUSIONS The color stability of multilayered polychromatic zirconia is influenced by the type of material, extrinsic coloring, and the chosen surface treatment post-artificial aging. The translucent 6Y-PSZ exhibited lower color stability, especially with only mechanical polishing. For the fabrication of M3Y-TZP and 6Y-PSZ monolithic multilayered polychromatic zirconia restorations, extrinsic coloring should be paired with glazing to maintain color stability. Conversely, in the absence of extrinsic coloring, both glazing and mechanical polishing are effective in preserving color stability.
Collapse
Affiliation(s)
- Feras M Abounassif
- Dental Department, Al Imam Abdulrahman Bin Faisal Hospital, National Guard Health Affairs, Dammam, Saudi Arabia
| | - Amal Alfaraj
- Department of Prosthodontics, College of Dentistry, King Faisal University, Al Ahsa, Saudi Arabia
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA
| | - Thuraya Gadah
- Department of Prosthodontics, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Chao-Chieh Yang
- Advanced Education Program in Prosthodontics, Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA
| | - Tien-Min G Chu
- Department of Biomedical Sciences and Comprehensive Care, Indiana University School of Dentistry, Indianapolis, Indiana, USA
| | - Wei-Shao Lin
- Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA
| |
Collapse
|
2
|
Samra N, Madina MM, El-Negoly SAER, Dawood L. The effect of restorative material selection and cementation procedures on the durability of endocrowns in the anterior teeth: an in-vitro study. BMC Oral Health 2024; 24:670. [PMID: 38851731 PMCID: PMC11161972 DOI: 10.1186/s12903-024-04381-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Accepted: 05/17/2024] [Indexed: 06/10/2024] Open
Abstract
OBJECTIVE To investigate the fracture resistance and failure modalities of anterior endocrown restorations fabricated employing diverse ceramic materials, and bonded using various cementation methodologies. MATERIALS AND METHODS Forty maxillary central incisors were divided into two main groups based on the ceramic materials used; GroupI (Zir): zirconia endocrwons (Zolid HT+, Ceramill, Amanngirrbach) and GroupII (E-Max): e-max endocrowns (IPS e.max CAD, Ivoclar Vivadent). Both groups were further split into two subgroups depending on the cementation protocols; subgroup IA "ZirMDP": endocowns cemented with MDP primer + MDP resin cement, subgroup IB (ZirNon-MDP): cemented with MDP primer + non-MDP resin cement, subgroup IIA (E-maxMDP): cemented with MDP primer + MDP resin cement, subgroup IIB (E-maxNon-MDP): cemented with MDP primer + non-MDP resin cement. (n = 10/subgroup). Endocrowns were manufactured using CAD/ CAM. Teeth were subjected to 10,000 thermal cycles. The fracture test was performed at 45o with a palatal force direction until the fracture occurred. Test results were recorded in Newton. The failure mode was examined using a stereomicroscope. A One-way ANOVA test was utilized to compare different groups regarding fracture strength values. Tukey`s Post Hoc was utilized for multiple comparisons. RESULTS The comparative analysis of fracture strength across the diverse groups yielded non-significant differences, as indicated by a p-value exceeding 0.05. Nonetheless, an observable trend emerged regarding the mode of failure. Specifically, a statistically significant prevalence was noted in fractures localized within the endocrown/tooth complex below the cementoenamel junction (CEJ) across all groups, except for Group IIB, "E-max Non-MDP," where fractures within the endocrown/tooth complex occurred above the CEJ. CONCLUSIONS Combining an MDP-based primer with an MDP-based resin cement did not result in a significant effect on the anterior endocrown fracture strength. CLINICAL RELEVANCE Regardless of the presence of the MDP monomer in its composition, adhesive resin cement achieved highly successful fracture strength when used with MDP-based ceramic primers. Additionally, ceramic materials exhibiting elastic moduli surpassing those of dentin are discouraged due to their propensity to induce catastrophic fractures within the tooth structure.
Collapse
Affiliation(s)
- Nehal Samra
- Prosthodontic Department, Faculty of Dentistry, Kafr Elsheikh University, Kafr Elsheikh, Egypt.
| | - Manal M Madina
- Fixed Prosthodontic department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | | | - Lamia Dawood
- Fixed Prosthodontic department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| |
Collapse
|
3
|
Lee J, Park HM, Kim YW. Comparative Analysis of Plaque Removal and Wear between Electric-Mechanical and Bioelectric Toothbrushes. Bioengineering (Basel) 2024; 11:474. [PMID: 38790341 PMCID: PMC11117528 DOI: 10.3390/bioengineering11050474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Revised: 04/28/2024] [Accepted: 05/01/2024] [Indexed: 05/26/2024] Open
Abstract
Effective oral care is important for maintaining a high quality of life. Therefore, plaque control can prevent the development and recurrence of periodontitis. Brushing with a toothbrush and toothpaste is a common way to remove plaque; however, excessive brushing or brushing with abrasive toothpaste can cause wear and tear on the dental crown. Hence, we aimed to quantitatively compare the plaque-removal efficiency and tooth wear of toothbrushes using the bioelectric effect (BE) with those of electric-mechanical toothbrushes. To generate the BE signal, an electronic circuit was developed and embedded in a toothbrush. Further, typodonts were coated with cultured artificial plaques and placed in a brushing simulator. A toothpaste slurry was applied, and the typodonts were eluted with tap water after brushing. The plaques of the typodonts were captured, and the images were quantified. For the tooth wear experiment, polymethyl methacrylate disk resin blocks were brushed twice a day, and the thickness of the samples was measured. Subsequently, statistical differences between the experimental toothbrushes and typical toothbrushes were analyzed. The BE toothbrush had a higher plaque-removal efficiency and could minimize tooth wear. This study suggests that the application of BE may be a new solution for oral care.
Collapse
Affiliation(s)
- Jihyun Lee
- Department of Periodontology, Ulsan University Hospital, College of Medicine, University of Ulsan, 877 Bangeojinsunhwando-ro, Dong-gu, Ulsan 44033, Republic of Korea;
| | - Hyun M. Park
- PAIST (ProxiHealthcare Institute for Science and Technology), ProxiHealthcare Inc., Seoul 08507, Republic of Korea
| | - Young Wook Kim
- PAIST (ProxiHealthcare Institute for Science and Technology), ProxiHealthcare Inc., Seoul 08507, Republic of Korea
| |
Collapse
|
4
|
Myagmar G, Daher R, Yeo ISL, Ahn JS, Han JS, Lee JH. Color and surface stainability of additively and subtractively manufactured interim restorative materials against mouth rinses. J Prosthet Dent 2023; 130:927-934. [PMID: 35850874 DOI: 10.1016/j.prosdent.2022.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 06/07/2022] [Accepted: 06/07/2022] [Indexed: 11/17/2022]
Abstract
STATEMENT OF PROBLEM Interim restorations are often used along with mouth rinses during the healing period following surgical procedures. However, evidence regarding the color and surface properties of digitally fabricated interim restorations after oral rinsing is lacking. PURPOSE The purpose of this in vitro study was to evaluate whether different mouth rinses could affect the color and surface roughness of milled and printed interim restorations after simulated oral rinsing. MATERIAL AND METHODS Disk-shaped specimens (Ø15×2 mm; N=180) were fabricated by using conventional (Jet Tooth Shade), milled (Yamahachi PMMA Disk), and printed (NextDent C&B) resin materials. All resin specimens were divided into 3 different groups according to the rinsing material: distilled water, whitening mouth rinse (Listerine Healthy White), and conventional mouth rinse (Listerine Cool Mint). The specimens were further allocated into short- and long-term subgroups, and oral rinsing simulation was performed (n=10). Short-term rinsing simulated the conditions in a usual interim restoration period, and long-term rinsing was performed to evaluate the properties of the interim materials. The color differences (CIEDE2000, ΔE00) between the baseline and each time point were determined by using a spectrophotometer. The surface roughness of the tested specimens was measured by using a confocal laser scanning microscope. Kruskal-Wallis and Friedman tests with nonparametric pairwise comparisons were used to analyze the data (α=.05). RESULTS On simulation of a 6-month use of the mouth rinse, the color change in the milled resin did not differ from that in the conventional resin (P>.334), but the printed resin showed a significantly greater color change than the other resins (P<.007). The greatest color change with the printed resin was observed when a conventional mouth rinse was used. However, all color changes were below a perceptible threshold of 1.30. When daily rinsing for 14 years was simulated, all resin groups showed a perceptible color change when conventional mouth rinse was used, and the printed resin showed the greatest median ±interquartile range ΔE00 (2.24 ±0.2). In both short- and long-term simulations, the printed resin rinsed with the conventional mouth rinse showed significantly greater roughness than that rinsed with distilled water (P<.009). CONCLUSIONS The printed resin showed higher stainability than the conventional resin, and the color change was greatest with the conventional mouth rinse. However, in 6 months of daily mouth rinse simulation, all the tested resin materials exhibited imperceptible color change and clinically acceptable surface roughness.
Collapse
Affiliation(s)
- Gerelmaa Myagmar
- PhD candidate, Department of Prosthodontics, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - René Daher
- Senior Lecturer, Division of Cariology and Endodontology, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland
| | - In-Sung Luke Yeo
- Professor, Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Jin-Soo Ahn
- Professor, Department of Dental Biomaterials Science and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Jung-Suk Han
- Professor, Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea
| | - Jae-Hyun Lee
- Assistant Professor, Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea.
| |
Collapse
|
5
|
Park HM, Ryu S, Jo E, Yoo SK, Kim YW. A Study on the Biofilm Removal Efficacy of a Bioelectric Toothbrush. Bioengineering (Basel) 2023; 10:1184. [PMID: 37892914 PMCID: PMC10604395 DOI: 10.3390/bioengineering10101184] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2023] [Revised: 10/07/2023] [Accepted: 10/11/2023] [Indexed: 10/29/2023] Open
Abstract
Effective oral care is a critical requirement to maintain a high quality of life. Most oral diseases are caused by plaque (oral biofilm), which is also correlated with systemic diseases. A common method to remove biofilm is brushing teeth with toothpaste. However, 3.5 billion people in the world have oral diseases, meaning that more efficient methods of removing biofilms are needed. We have developed a toothbrush that applies a bioelectric effect (BE) utilizing an electric force for biofilm removal. It demonstrated significantly higher biofilm removal efficiency than non-BE manual toothbrushes. Tests were performed in saline and toothpaste conditions using various pressures. Results showed that the BE toothbrush had a significantly higher biofilm removal efficiency in saline (0.5 N: 215.43 ± 89.92%, 2.5 N: 116.77 ± 47.02%) and in a toothpaste slurry (0.5 N: 104.96 ± 98.93%, 2.5 N: 96.23 ± 35.16%) than non-BE manual toothbrushes. Results also showed that BE toothbrushes were less dependent on toothpaste. This study suggests that the application of BE can be a new solution to plaque problems in oral care.
Collapse
Affiliation(s)
- Hyun Mok Park
- PAIST (ProxiHealthcare Advanced Institute for Science and Technology), Seoul 04513, Republic of Korea; (H.M.P.); (S.R.); (E.J.)
- Graduate Program of Biomedical Engineering, Yonsei University, Seoul 03722, Republic of Korea
- Department of Medical Engineering, Yonsei University College of Medicine, Seoul 03722, Republic of Korea
| | - Seungjae Ryu
- PAIST (ProxiHealthcare Advanced Institute for Science and Technology), Seoul 04513, Republic of Korea; (H.M.P.); (S.R.); (E.J.)
| | - Eunah Jo
- PAIST (ProxiHealthcare Advanced Institute for Science and Technology), Seoul 04513, Republic of Korea; (H.M.P.); (S.R.); (E.J.)
| | - Sun Kook Yoo
- Graduate Program of Biomedical Engineering, Yonsei University, Seoul 03722, Republic of Korea
- Department of Medical Engineering, Yonsei University College of Medicine, Seoul 03722, Republic of Korea
| | - Young Wook Kim
- PAIST (ProxiHealthcare Advanced Institute for Science and Technology), Seoul 04513, Republic of Korea; (H.M.P.); (S.R.); (E.J.)
| |
Collapse
|
6
|
Al-Angari NS, Quwayhis S, Almayouf N, Meaigel S, Aldahash A, Al-Angari SS. Effect of staining and whitening systems on color stability of computer aided design/computer aided manufacturing lithium disilicate glass ceramic. Saudi Dent J 2023; 35:359-364. [DOI: 10.1016/j.sdentj.2023.03.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Revised: 03/26/2023] [Accepted: 03/27/2023] [Indexed: 04/03/2023] Open
|
7
|
Biomimetic Whitening Effect of Polyphosphate-Bleaching Agents on Dental Enamel. Biomimetics (Basel) 2022; 7:biomimetics7040183. [PMID: 36412711 PMCID: PMC9680262 DOI: 10.3390/biomimetics7040183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 10/23/2022] [Accepted: 10/24/2022] [Indexed: 12/14/2022] Open
Abstract
This in vitro study investigated the extrinsic tooth-whitening effect of bleaching products containing polyphosphates on the dental enamel surface compared to 10% carbamide peroxide (CP). Eighty human molars were randomly allocated into four whitening-products groups. Group A (control) was treated with 10% CP (Opalescence). The other groups with non-CP over-the-counter (OTC) products were group B = polyphosphates (iWhiteWhitening-Kit); group C = polyphosphates+fluoride (iWhite-toothpaste); and group D = sodium bicarbonate (24K-Whitening-Pen). L*, a*, b* color-parameters were spectrophotometer-recorded at baseline (T0), one day (T1), and one month (T2) post-treatment. Changes in teeth color (ΔEab) were calculated. Data were analyzed using ANOVA and the Bonferroni test (α = 0.05). Groups A, B, and D showed significant differences in ΔL*&Δa* parameters at T1, but not in Δb* at T0. Group C showed no difference for ΔL*, Δa*, Δb* at T0 and T1. Group A showed differences for ΔL*, Δa*, Δb*, at T2, while groups B, C, and D had no difference in any parameters at T0. At T1, ΔEab values = A > D> B > C (ΔEab = 13.4 > 2.4 > 2.1 > 1.2). At T2, ΔEab values increased = A > B > C > D (ΔEab = 12.2 > 10.6 > 9.2 > 2.4). In conclusion, the 10% CP and Biomimetic polyphosphate extrinsic whitening kit demonstrated the highest color change, while simulated brushing with dark stain toothpaste and a whitening pen demonstrated the lowest color change at both measurement intervals.
Collapse
|
8
|
Abdulla MA, Hasan RH. Shear Bond Strength of Two Repair Systems to Zirconia Ceramic by Different Surface Treatments. J Lasers Med Sci 2022; 13:e31. [PMID: 36743152 PMCID: PMC9841374 DOI: 10.34172/jlms.2022.31] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Accepted: 06/29/2022] [Indexed: 11/22/2022]
Abstract
Introduction: Intraoral repair has been suggested as a treatment option to repair the chipping or fracture of veneered zirconia; the success of the procedure is mainly determined by the bonding between zirconia and composite resin. The present study aimed to investigate and compare the shear bond strength (SBS) of two intraoral repair systems to zirconia ceramic treated with a laser or air-abrasion surface modification. Methods: Ninety tube-shaped samples (diameter of 10 mm and height of 4 mm) were divided into three main groups: Group I (zirconia 100%, n=30); Group II (veneer ceramic 100% n=30); Group III (zirconia with a veneer ceramic n=30). Each main group was subdivided into two subgroups (n=15): Subgroup A: samples repaired with Ceramic Repair N; Subgroup B: samples repaired with the Cimara Repair System. The subgroup samples were further subdivided based on the treated surface (n=5 samples): Control (no surface modification), Er,Cr:YSGG laser surface modification, and air-abrasion surface modification. The SBS was employed using a universal testing machine. The mode of failure was observed using a stereomicroscope. Results: Significant differences were observed in the mean SBS values between the different surface modifications (P˂0.05). Tukey's post hoc test showed that the air-abrasion surface modification of the veneer ceramic repaired with the Ceramic repair N system had the highest mean value (13.74 MPa) among the different groups, while no surface modification of zirconia repaired with the Cimara repair system had the lowest mean value (2.84 MPa). The control group (no surface modification) had the lowest mean value among all the treated groups. Conclusion: The SBS is surface modification-dependent, and higher SBS is obtained by air-abrasion than Er, Cr:YSGG laser surface modifications with the selected parameters. The Ceramic repair N system had significantly higher SBS for all surface-treated substrates than the Cimara repair system.
Collapse
|
9
|
Effect of Over-The-Counter Tooth-Whitening Products on Enamel Surface Roughness and Microhardness. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12146930] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background: To evaluate the efficacy of new over-the-counter tooth-whitening products on enamel surface roughness and microhardness. Methods: A total of 120 enamel specimens were prepared and randomly allocated into six groups. Group A was treated with 10% carbamide peroxide; Group B was immersed in distilled water; Group C was treated with hydrated silica, sodium hexametaphosphate toothpaste; Group D was treated with sodium bicarbonate; Group E was treated with 0.25% citric acid; and Group F was treated with hydrated silica, charcoal powder. Results: A, B, and D demonstrated decreased Ra, whereas Groups C, E, and F showed an increased Ra after whitening. The changes in Ra from T0 to T1 in each group was statistically significant (p < 0.001) except for Group B (p = 0.85). The groups showed decreased KHN after whitening, except for specimens in Group B (distilled water). The KHN from T0 to T1 decreased significantly for groups A, C, E, and F (p = 0.001). Significant difference was observed at T1 (p < 0.0001). Conclusion: Within the limitations of this study, it could be demonstrated that surface roughness and enamel microhardness changes were influenced by the type, composition, and exposure time of the whitening product.
Collapse
|
10
|
Li M, Yang Z, Huang Y, Li Y, Zhou Z. In vitro effect of resin infiltrant on resistance of sound enamel surfaces in permanent teeth to demineralization. PeerJ 2022; 9:e12008. [PMID: 35047244 PMCID: PMC8759355 DOI: 10.7717/peerj.12008] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Accepted: 07/27/2021] [Indexed: 12/20/2022] Open
Abstract
OBJECTIVE To investigate the effect of resin infiltrant on resistance of sound permanent enamel surfaces to demineralization. METHOD Eighty healthy premolars were sectioned to obtain enamel blocks from the buccal surface. Specimens with baseline surface microhardness values of 320-370 were selected. The experimental group were treated with resin infiltrant, while the control group was not. Specimens from each group were artificially demineralized and the surface microhardness values were measured again. Confocal laser scanning microscopy was used to measure the depth of demineralization and detect the penetration ability of the resin infiltrant. The specimens were subjected to a simulated toothbrushing abrasion test. Scanning electron microscopy was used to observe changes in the surface morphology of specimens after each of these procedures. RESULTS No significant differences between the experimental and control groups were observed in the baseline microhardness values or in the experimental group after resin infiltration compared with the baseline conditions. After artificial demineralization, the microhardness value in the control group was significantly lower than that in the experimental group (266.0 (±34.5) compared with 304.0 (±13.0), P = 0.017). Confocal laser scanning microscopy results showed that the demineralization depth in the control group was significantly deeper than that in the experimental group (97.9 (±22.8) µm vs. 50.4 (±14.3) µm, P < 0.001), and that resin infiltrant completely penetrated the acid-etched demineralized area of the tooth enamel with a mean penetration depth of 31.6 (±9.0) µm. Scanning electron microscopy showed that the surface morphology was more uniform and smoother after simulated toothbrushing. The enamel surface structure was more severely destroyed in the control group after artificial demineralization compared with that of the experimental group. CONCLUSION Resin infiltrant can completely penetrate an acid-etched demineralized enamel area and improve resistance of sound enamel surfaces to demineralization. Our findings provide an experimental basis for preventive application of resin infiltrant to sound enamel surfaces to protect tooth enamel against demineralization.
Collapse
Affiliation(s)
- Meng Li
- Stomatological Hospital of Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China.,Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Zhengyan Yang
- Stomatological Hospital of Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China.,Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Yajing Huang
- Stomatological Hospital of Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China.,Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Yueheng Li
- Stomatological Hospital of Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China.,Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| | - Zhi Zhou
- Stomatological Hospital of Chongqing Medical University, Chongqing, China.,Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, China.,Chongqing Municipal Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing, China
| |
Collapse
|
11
|
Assessment of Knowledge, Attitude, and Practice of Iranian Nurses towards Toothbrush Maintenance and Use. Nurs Res Pract 2021; 2021:3694141. [PMID: 34950516 PMCID: PMC8692049 DOI: 10.1155/2021/3694141] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2021] [Accepted: 12/03/2021] [Indexed: 11/17/2022] Open
Abstract
Background Since nurses are considered a role model in society, they should have sufficient knowledge, attitude, and practice in the field of oral hygiene. This study was aimed to assess the nurses' knowledge, practice, and attitude towards toothbrush maintenance and use. Methods In this cross-sectional study, 325 nurses working in hospitals affiliated to Kermanshah University of Medical Sciences were randomly recruited. Data collection tools included a demographic information form and a researcher-made questionnaire on knowledge, attitude, and practice regarding toothbrush maintenance and use. Data were analyzed by SPSS software using descriptive and inferential statistics (Mann–Whitney U and Kruskal–Wallis H). Results The mean scores of nurses' knowledge, attitude, and practice were 59.2 ± 16.4, 64.2 ± 20.6, and 51.4 ± 17.0 out of 100, respectively. There was no statistically significant relation between nurses' knowledge, attitude, and practice and their gender, age, level of education, and work experience. Conclusions Nurses had moderate knowledge, attitude, and practice regarding toothbrush maintenance and use, which is not very desirable given their role model. Therefore, training courses are recommended to be held to increase the nurses' knowledge, attitude, and practice regarding toothbrush maintenance and use.
Collapse
|
12
|
Lee WF, Iwasaki N, Peng PW, Takahashi H. Effect of toothbrushing on the optical properties and surface roughness of extrinsically stained high-translucency zirconia. Clin Oral Investig 2021; 26:3041-3048. [PMID: 34845525 DOI: 10.1007/s00784-021-04287-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Accepted: 11/01/2021] [Indexed: 12/17/2022]
Abstract
OBJECTIVES The effect of toothbrushing on the color, relative translucency, and surface roughness of extrinsically stained zirconia dental restorations is still unclear. The purpose of the present study was to evaluate the optical properties and surface textures of extrinsically stained or glazed partially stabilized zirconia with 5 mol% yttria (5Y-PSZ) after toothbrushing by determining changes in the color, translucency parameter (TP), and surface roughness. MATERIALS AND METHODS Specimens (2 mm thick; n = 50) were sectioned from 5Y-PSZ blanks. Three brands of powdered stains (namely VI, SH, IV) and a glaze (GL) were used to extrinsically stain the specimen surfaces (n = 10 per group). The specimens were subjected to 10,000-50,000 simulated toothbrushing strokes using a toothpaste slurry (Ora2 PREMIUM Stain clear paste). The color parameters were measured before staining or glazing and before and after simulated brushing. The color changes and TP values can be calculated before and after simulated brushing. The surface roughness was also evaluated. RESULTS Significant changes were found in the shade and TP values of 5Y-PSZ after extrinsic staining, but no significant changes were found after toothbrushing, irrespective of the staining brand (p > 0.05). The surface roughness of the characterized 5Y-PSZ specimens decreased after toothbrushing, whereas that of the non-characterized 5Y-PSZ group increased. CONCLUSIONS Toothbrushing markedly affects the surface roughness of extrinsically stained or glazed 5Y-PSZ specimens, whereas no impacts on the color or translucency were observed. CLINICAL RELEVANCE For esthetic reasons, clinicians and dental technicians prefer to apply extrinsic stains to zirconia restorations, which profoundly affects its appearance. The limited influence of toothbrushing on color and translucency of 5Y-PSZ is promising for clinical applications.
Collapse
Affiliation(s)
- Wei-Fang Lee
- School of Dental Technology, Taipei Medical University, Taipei, 11031, Taiwan
| | - Naohiko Iwasaki
- Department of Oral Biomaterials Development Engineering, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, 113-8549, Japan
| | - Pei-Wen Peng
- School of Dental Technology, Taipei Medical University, Taipei, 11031, Taiwan.
| | - Hidekazu Takahashi
- Department of Oral Biomaterials Development Engineering, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, 113-8549, Japan.
| |
Collapse
|
13
|
Al-Angari SS, Meaigel S, Almayouf N, Quwayhis S, Aldahash A, Al-Angari NS. The Effects of a coffee beverage and whitening systems on surface roughness and gloss of CAD/CAM lithium disilicate glass ceramics. J Appl Biomater Funct Mater 2021; 19:22808000211058866. [PMID: 34816765 DOI: 10.1177/22808000211058866] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
OBJECTIVES To investigate the effects of a coffee beverage and two whitening systems on the surface roughness and gloss of glazed Lithium Disilicate Glass-Ceramics (LDGC) for computer-aided design/computer-aided manufacturing (CAD/CAM) systems. METHODS Sixty-eight LDGC disks (12 × 10 × 2 mm) were prepared from blocks of CAD/CAM systems (IPS e.max CAD ceramic). Baseline measurements for surface roughness (Ra) and gloss (GU) were taken using a 3-D optical profilometer and a glossmeter, respectively; then specimens were randomized into four groups (n = 17). All specimens were immersed in a coffee solution (24 h × 12 days) then subjected to two whitening systems. G1-negative control (kept moist × 7 days); G2-positive control (brushed with distilled water, 200 g/load, 2 min twice daily × 7 days); G3-whitening toothpaste (Colgate optic white; relative dentin abrasivity (RDA) = 100, 200 g/load, 2 min twice daily × 7 days); and G4-simulated at-home bleaching protocol (Opalescence,15% carbamide peroxide (CP), 6 h/day × 7 days). The study outcomes were measured at baseline and after the treatments. Data were analyzed using paired T-test and one-way ANOVA (α = 0.05). RESULTS The mean surface roughness significantly increased (p ⩽ 0.002) for all groups after the designated treatment protocols. Among groups, the mean surface roughness of G2 and G3 were significantly higher (p ⩽ 0.001) (Ra: 0.51 and 0.57 μm, respectively) compared to the control group (Ra: 0.23 μm), and were not significantly different from G4 (Ra: 0.46 μm). Surface gloss decreased with no significant change within or among groups after treatment. CONCLUSION All glazed LDGC had a significant increase in surface roughness after being subjected to simulated 1 year of coffee drinking and whitening systems (15% CP and whitening toothpaste), and the greatest change was associated with brushing (simulating 8 months). However, coffee beverages and whitening systems had no significant effect on the surface gloss.
Collapse
Affiliation(s)
- Sarah S Al-Angari
- Department of Restorative Dental Science, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Shahad Meaigel
- Department of Prosthodontics, King Abdulaziz Medical City, National Guard Health Affairs, Riyadh, Saudi Arabia.,King Abdullah International Medical Research Center, Riyadh, Saudi Arabia.,Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, King Saud bin Abdulaziz University for Health Sciences (KSAU-HS), Riyadh, Saudi Arabia
| | - Nouf Almayouf
- King Abdullah International Medical Research Center, Riyadh, Saudi Arabia
| | - Shahad Quwayhis
- Department of Prosthodontics, King Abdulaziz Medical City, National Guard Health Affairs, Riyadh, Saudi Arabia.,King Abdullah International Medical Research Center, Riyadh, Saudi Arabia.,Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, King Saud bin Abdulaziz University for Health Sciences (KSAU-HS), Riyadh, Saudi Arabia
| | - Abdulelah Aldahash
- Department of Prosthodontics, King Abdulaziz Medical City, National Guard Health Affairs, Riyadh, Saudi Arabia.,King Abdullah International Medical Research Center, Riyadh, Saudi Arabia.,Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, King Saud bin Abdulaziz University for Health Sciences (KSAU-HS), Riyadh, Saudi Arabia
| | - Nadia S Al-Angari
- Department of Prosthodontics, King Abdulaziz Medical City, National Guard Health Affairs, Riyadh, Saudi Arabia.,King Abdullah International Medical Research Center, Riyadh, Saudi Arabia.,Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, King Saud bin Abdulaziz University for Health Sciences (KSAU-HS), Riyadh, Saudi Arabia
| |
Collapse
|
14
|
Aldosari LI, Alshadidi AA, Porwal A, Al Ahmari NM, Al Moaleem MM, Suhluli AM, Shariff M, Shami AO. Surface roughness and color measurements of glazed or polished hybrid, feldspathic, and Zirconia CAD/CAM restorative materials after hot and cold coffee immersion. BMC Oral Health 2021; 21:422. [PMID: 34461868 PMCID: PMC8404315 DOI: 10.1186/s12903-021-01770-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2020] [Accepted: 08/11/2021] [Indexed: 11/25/2022] Open
Abstract
Background The purpose of this study evaluates and compares the effect of surface roughness (Ra) and color stability on computer-aided design/computer-aided manufacturing (CAD/CAM) hybrid resin (Vita Enamic), feldspathic (Vitablocs® Mark II), and lithium disilicate Zirconia (Vita Suprinity) glazed or polished ceramics immersed in hot Arabic Qahwa and cold coffee. Methods A total of 96 standardized samples were prepared from CAD/CAM restorative materials. Half of the samples were polished as per the manufacturer’s instructions using a porcelain polishing kit, and the other half were glazed. Samples were distributed and immersed in hot Arabian Qahwa and cold coffee followed by thermocycling. Ra measurements and color changes were conducted before and after immersion. SEM images were captured from each type of glazed or polished ceramic. One-way ANOVA paired Student’s t-test, and Bonferroni test were conducted to detect significant difference between the groups. P > 0.05 was a significant level. Results Of all the tested samples, Ra increased without any significant difference; however, mean color changes (ΔE*) showed significant differences. An increase in Ra was noted for all the glazed and polished samples after immersion and thermocycling. However, differences were significant only in VM II. In addition, ΔE* was significant only in Vita Suprinity (VS) samples. For immersion groups, significant Ra changes were noticed in glazed samples, only in Vita Enamic (VE) with no ΔE*. In polished samples, mean Ra changes were observed in VM II and VS samples. Significant differences were also noticed in polished VE and VS subgroups of ΔE*. Conclusions Ra affects all the tested samples, providing higher values on the polished specimens. The ΔE* caused by hot Arabic Qahwa and cold coffee on glazed or polished CAD/CAM restorative materials were clinically acceptable.
Collapse
Affiliation(s)
- Lujain I Aldosari
- Prosthetic Department, College of Dentistry, King Khalid University, Abha, Kingdom of Saudi Arabia
| | | | - Amit Porwal
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan, 45142, Kingdom of Saudi Arabia
| | - Nasser M Al Ahmari
- Prosthetic Department, College of Dentistry, King Khalid University, Abha, Kingdom of Saudi Arabia
| | - Mohammed M Al Moaleem
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan, 45142, Kingdom of Saudi Arabia.
| | - Ahmed M Suhluli
- Intern Department, College of Dentistry, Jazan University, Jazan, Kingdom of Saudi Arabia
| | - Mansoor Shariff
- Prosthetic Department, College of Dentistry, King Khalid University, Abha, Kingdom of Saudi Arabia
| | - Ahmed O Shami
- Intern Department, College of Dentistry, Jazan University, Jazan, Kingdom of Saudi Arabia
| |
Collapse
|
15
|
Lee JH, Jang HY, Lee SY. Finite Element Analysis of Dental Implants with Zirconia Crown Restorations: Conventional Cement-Retained vs. Cementless Screw-Retained. MATERIALS 2021; 14:ma14102666. [PMID: 34069608 PMCID: PMC8160992 DOI: 10.3390/ma14102666] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 05/15/2021] [Accepted: 05/17/2021] [Indexed: 11/16/2022]
Abstract
The present study was designed to compare the stress distributions in two restoration types of implants and the surrounding bone. The first restoration type was a conventional cement-retained zirconia crown, and the second was a novel cementless screw-retained zirconia crown with a base abutment. A three-dimensional finite element method was used to model the implants, restorations, and supporting bone. A comparative study of the two implants was performed under two masticatory loads: a vertical load of 100 N and a 30-degree oblique load of 100 N. Under both loading conditions, the maximum von Mises stress and strain values in the implant and supporting bone were higher in the conventional cement-retained restoration model than in the cementless screw-retained model. In terms of stress distribution, the cementless screw-retained zirconia crown with base abutment may be considered a superior restoration option compared to the conventional cement-retained zirconia crown.
Collapse
Affiliation(s)
- Jae-Hyun Lee
- Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul 03080, Korea;
| | - Ho Yeol Jang
- Private Dental Clinic, 130 Cheongsa-ro, Seo-gu, Daejeon 35220, Korea;
| | - Su Young Lee
- Department of Prosthodontics, Seoul St. Mary’s Dental Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul 06591, Korea
- Correspondence: ; Tel.: +82-2-2258-6309
| |
Collapse
|
16
|
Do “cut out-rescan” procedures have an impact on the accuracy of intraoral digital scans? J Prosthet Dent 2021; 125:89-94. [DOI: 10.1016/j.prosdent.2019.11.018] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Revised: 11/16/2019] [Accepted: 11/18/2019] [Indexed: 11/23/2022]
|
17
|
Al Moaleem MM, AlSanosy R, Al Ahmari NM, Shariff M, Alshadidi AA, Alhazmi HA, Khalid A. Effects of Khat on Surface Roughness and Color of Feldspathic and Zirconia Porcelain Materials under Simulated Oral Cavity Conditions. MEDICINA (KAUNAS, LITHUANIA) 2020; 56:E234. [PMID: 32414190 PMCID: PMC7279326 DOI: 10.3390/medicina56050234] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Revised: 04/08/2020] [Accepted: 04/13/2020] [Indexed: 11/28/2022]
Abstract
Background and Objectives: Khat chewing is considered as a daily habit that is practiced by more than five million people globally. The effect of khat chewing on the surface roughness and the color stability of natural teeth and the material used in the fabrication of dental prosthesis remains unknown. This study was conducted to explore and compare the effect of khat homogenate (KH) on the surface roughness (Ra) and the average color changes (ΔE*) amongst natural teeth and selected shades from different porcelain types, namely, feldspathic metal ceramic (MC) VM13, computer-aided design/computer assisted manufacture (CAD/CAM) feldspathic (Vitablocs Mark II), and multilayer zirconia (Ceramill Zolid PS) porcelains. Materials and Methods: Seventy samples were prepared from natural teeth, feldspathic MC, CAD/CAM Vitablocs Mark II, and zirconia porcelain. The Ra values were measured using a profilometer and expressed in micrometers, whereas the ΔE* values were measured using VITA Easyshade® V spectrophotometer for all samples before and after frequent immersion and thermocycling in KH for 30 days. The surface topography was used to assess the materials surfaces (glazed or polished) after KH immersion by using a white light interferometry machine. Results: Results revealed that the Ra and the ΔE* values of the different types of tested porcelain were influenced by KH. The order of surface roughness values was glazed or polished MC > polished Zircon > polished Vitablocs Mark II > natural teeth. The lowest ΔE* values were recorded for glazed Vitablocs Mark II and MC, and the values could be arranged as polished zircon > natural teeth > glazed zircon > polished MC > polished Vitablocs Mark II. P values were significantly varied (< 0.001) among all the tested groups, except the zircon group (>0.05) for both Ra and ΔE*. Conclusion: KH significantly affected both surface parameter and color of glazed or polished porcelain materials and natural teeth.
Collapse
Affiliation(s)
- Mohammed M. Al Moaleem
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia
| | - Rashad AlSanosy
- Substance Abuse and Toxicology Research Center, Jazan 45142, Saudi Arabia; (R.A.); (H.A.A.); (A.K.)
| | - Nasser M. Al Ahmari
- Prosthetic Department, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia; (N.M.A.A.); (M.S.)
| | - Mansoor Shariff
- Prosthetic Department, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia; (N.M.A.A.); (M.S.)
| | | | - Hassan A. Alhazmi
- Substance Abuse and Toxicology Research Center, Jazan 45142, Saudi Arabia; (R.A.); (H.A.A.); (A.K.)
- Department of Pharmaceutical Chemistry, College of Pharmacy, Jazan University, Jazan 45142, Saudi Arabia
| | - Asaad Khalid
- Substance Abuse and Toxicology Research Center, Jazan 45142, Saudi Arabia; (R.A.); (H.A.A.); (A.K.)
- Medicinal and Aromatic Plants Research Institute, National Center for Research, Khartoum 11123, Sudan
| |
Collapse
|
18
|
Kontonasaki E, Rigos AE, Ilia C, Istantsos T. Monolithic Zirconia: An Update to Current Knowledge. Optical Properties, Wear, and Clinical Performance. Dent J (Basel) 2019; 7:dj7030090. [PMID: 31480688 PMCID: PMC6784470 DOI: 10.3390/dj7030090] [Citation(s) in RCA: 72] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2019] [Revised: 07/22/2019] [Accepted: 08/20/2019] [Indexed: 01/09/2023] Open
Abstract
The purpose of this paper was to update the knowledge concerning the wear, translucency, as well as clinical performance of monolithic zirconia ceramics, aiming at highlighting their advantages and weaknesses through data presented in recent literature. New ultra-translucent and multicolor monolithic zirconia ceramics present considerably improved aesthetics and translucency, which, according to the literature reviewed, is similar to those of the more translucent lithium disilicate ceramics. A profound advantage is their high strength at thin geometries preserving their mechanical integrity. Based on the reviewed articles, monolithic zirconia ceramics cause minimal wear of antagonists, especially if appropriately polished, although no evidence still exists regarding the ultra-translucent compositions. Concerning the survival of monolithic zirconia restorations, the present review demonstrates the findings of the existing short-term studies, which reveal promising results after evaluating their performance for up to 5 or 7 years. Although a significant increase in translucency has been achieved, new translucent monolithic zirconia ceramics have to be further evaluated both in vitro and in vivo for their long-term potential to preserve their outstanding properties. Due to limited studies evaluating the wear properties of ultra-translucent material, no sound conclusions can be made, whereas well-designed clinical studies are urgently needed to enlighten issues of prognosis and long-term survival.
Collapse
Affiliation(s)
- Eleana Kontonasaki
- Department of Prosthodontics, School of Dentistry, Faculty of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.
| | | | | | | |
Collapse
|
19
|
Muntean A, Sava S, Delean AG, Mihailescu AM, Dumitrescu LS, Moldovan M, Festila DG. Toothpaste Composition Effect on Enamel Chromatic and Morphological Characteristics: In Vitro Analysis. MATERIALS 2019; 12:ma12162610. [PMID: 31426296 PMCID: PMC6720655 DOI: 10.3390/ma12162610] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Revised: 08/06/2019] [Accepted: 08/10/2019] [Indexed: 12/21/2022]
Abstract
The aim of this in vitro study was to assess the effect of toothpastes, with different compositions, on optical and morphological features of sound and demineralized enamel. We selected twenty-five teeth, recently extracted for orthodontic purposes, for this in vitro study. The teeth were caries free, without stains, fissures, filling or hypoplasia observed at inspection under standard conditions. Teeth were brushed (for 2–3 min, twice a day, for 21 days), with five different toothpastes (four commercially available and an experimental one) containing fluoride and hydroxyapatite. After that, teeth were demineralized with 37% orthophosforic acid (Ultra Etch®, Ultradent Products Inc., South Jordan, UT, USA) for 60 s. We repeated the brushing protocol for another 21 days on demineralized enamel. Enamel vestibular surfaces were examined using a spectrophotometer (Vita EasyShade -Vita Zahnfabrik, Bad Sackingen, Germany) and a Scanning Electron Microscope (Inspect S®, FEI Company, Hillsboro, OR, USA). Differences were statistically significant for colour parameters L* and ΔE*. SEM evaluation reveals demineralized enamel mineral gain after brushing with selected toothpastes. Toothpastes with specific ingredients can represent a balance between aesthetic and mineralization, and an oral hygiene correct algorithm is able to preserve enamel characteristics during ortodontic treatement with fixed appliances.
Collapse
Affiliation(s)
- Alexandrina Muntean
- Paediatric Dentistry Department 2, Iuliu Hatieganu University of Medicine and Pharmacy, 31 A. Iancu Street, 400083 Cluj-Napoca, Romania
| | - Sorina Sava
- Prosthodontics and Dental Materials Department 4, Iuliu Hatieganu University of Medicine and Pharmacy, 15 V. Babes Street, 400012 Cluj-Napoca, Romania.
| | - Ada Gabriela Delean
- Conservative Dentistry Department 2, Iuliu Hatieganu University of Medicine and Pharmacy, 33 Motilor Street, 400001 Cluj-Napoca, Romania
| | - Ana Maria Mihailescu
- Oral Rehabilitation Department 3, Iuliu Hatieganu University of Medicine and Pharmacy, 15 V. Babes Street, 400012 Cluj-Napoca, Romania
| | - Laura Silaghi Dumitrescu
- Department of Polymeric Composites, Babes-Bolyai University, Institute of Chemistry Raluca Ripan, 30 Fantanele Str., 400294 Cluj-Napoca, Romania
| | - Marioara Moldovan
- Department of Polymeric Composites, Babes-Bolyai University, Institute of Chemistry Raluca Ripan, 30 Fantanele Str., 400294 Cluj-Napoca, Romania
| | - Dana Gabriela Festila
- Orthodontics Department 1, Iuliu Haţieganu University of Medicine and Pharmacy, 31 A. Iancu Street, 400083 Cluj-Napoca, Romania
| |
Collapse
|
20
|
Scaminaci Russo D, Cinelli F, Sarti C, Giachetti L. Adhesion to Zirconia: A Systematic Review of Current Conditioning Methods and Bonding Materials. Dent J (Basel) 2019; 7:dj7030074. [PMID: 31374820 PMCID: PMC6784479 DOI: 10.3390/dj7030074] [Citation(s) in RCA: 64] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Revised: 06/13/2019] [Accepted: 07/06/2019] [Indexed: 11/16/2022] Open
Abstract
Background. Reliable bonding between resin composite cements and high strength ceramics is difficult to achieve because of their chemical inertness and lack of silica content that makes etching impossible. The purpose of this review is to classify and analyze the existing methods and materials suggested to improve the adhesion of zirconia to dental substrate by using composite resins, in order to explore current trends in surface conditioning methods with predictable results. Methods. The current literature, examining the bond strength of zirconia ceramics, and including in vitro studies, clinical studies, and a systematic review, was analyzed. The research in the literature was carried out using PubMed and Cochrane Library databases, only papers in English, published online from 2013 to 2018. The following keywords and their combinations were used: Zirconia, 3Y-TZP, Adhesion, Adhesive cementation, Bonding, Resin, Composite resin, Composite material, Dentin, Enamel. Results. Research, in PubMed and Cochrane Library databases, provided 390 titles with abstracts. From these, a total of 93 publications were chosen for analysis. After a full text evaluation, seven articles were discarded. Therefore, the final sample was 86, including in vitro, clinical studies, and one systematic review. Various adhesive techniques with different testing methods were examined. Conclusions. Airborne-particle abrasion and tribo-chemical silica coating are the pre-treatment methods with more evidence in the literature. Increased adhesion could be expected after physico-chemical conditioning of zirconia. Surface contamination has a negative effect on adhesion. There is no evidence to support a universal adhesion protocol.
Collapse
Affiliation(s)
- Daniele Scaminaci Russo
- Department of Experimental and Clinical Medicine-Unit of Dentistry, University of Florence, Via del Ponte di Mezzo, 48-50127 Firenze, Italy
| | - Francesca Cinelli
- Department of Experimental and Clinical Medicine-Unit of Dentistry, University of Florence, Via del Ponte di Mezzo, 48-50127 Firenze, Italy
| | - Chiara Sarti
- Department of Experimental and Clinical Medicine-Unit of Dentistry, University of Florence, Via del Ponte di Mezzo, 48-50127 Firenze, Italy
| | - Luca Giachetti
- Department of Experimental and Clinical Medicine-Unit of Dentistry, University of Florence, Via del Ponte di Mezzo, 48-50127 Firenze, Italy.
| |
Collapse
|