1
|
Kostretzis L, Martinov S, Lavigne M, Massé V, Vendittoli PA. Liner dissociation in a large-diameter ceramic-bearing acetabular component: a report of five cases. BMC Musculoskelet Disord 2022; 23:136. [PMID: 35139828 PMCID: PMC8829977 DOI: 10.1186/s12891-022-05082-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Accepted: 02/02/2022] [Indexed: 11/22/2022] Open
Abstract
Background Ceramic-on-ceramic (CoC) bearings for total hip arthroplasty (THA) have been offering very favorable results and survivorship since their introduction. In order to increase range of movement (ROM) and decrease dislocation rates, some manufacturers have introduced larger diameter head (LDH) CoC bearings. This has been achieved with the use of preassembled cup designs, in which the ceramic liner is already fitted into the metal backing and implanted as a monoblock component by the surgeon. In this report we present data from a series of 5 patients with ceramic liner dissociation from a monoblock cup. Case presentation All cases were overweight men with acetabular components of 56 or 58 mm. After a mean of 5.5 (range, 3.5-6.7) years, all patients reported sudden pain and audible noise when performing activities of daily living. Liner displacement was suspected on plain radiographs and confirmed by Ct-scan. Pneumarthrosis was present in all cases. Taper modular junction wear and corrosion signs were observed in the four revised patients. Conclusion Although one of our case is still treated conservatively, implant revision is probably inevitable. Further LDH CoC implant design should take in consideration this potential complication by avoiding bearing diameters over 40mm and/or improving locking mechanism or by providing a real monoblock acetabular implant.
Collapse
Affiliation(s)
- Lazaros Kostretzis
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada
| | - Sagi Martinov
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada
| | - Martin Lavigne
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada.,Clinique Orthopédique Duval, Laval, QC, Canada
| | - Vincent Massé
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada.,Clinique Orthopédique Duval, Laval, QC, Canada
| | - Pascal-André Vendittoli
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada. .,Clinique Orthopédique Duval, Laval, QC, Canada.
| |
Collapse
|
2
|
Special Issue "Novel Research about Biomechanics and Biomaterials Used in Hip, Knee and Related Joints". MATERIALS 2021; 14:ma14092222. [PMID: 33925899 PMCID: PMC8123477 DOI: 10.3390/ma14092222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Download PDF] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Accepted: 04/25/2021] [Indexed: 12/03/2022]
|