1
|
Michaud F, Mouzo F, Dopico D, Cuadrado J. A Sensorized 3D-Printed Knee Test Rig for Preliminary Experimental Validation of Patellar Tracking and Contact Simulation. SENSORS (BASEL, SWITZERLAND) 2024; 24:3042. [PMID: 38793897 PMCID: PMC11125272 DOI: 10.3390/s24103042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 05/03/2024] [Accepted: 05/08/2024] [Indexed: 05/26/2024]
Abstract
Experimental validation of computational simulations is important because it provides empirical evidence to verify the accuracy and reliability of the simulated results. This validation ensures that the simulation accurately represents real-world phenomena, increasing confidence in the model's predictive capabilities and its applicability to practical scenarios. The use of musculoskeletal models in orthopedic surgery allows for objective prediction of postoperative function and optimization of results for each patient. To ensure that simulations are trustworthy and can be used for predictive purposes, comparing simulation results with experimental data is crucial. Although progress has been made in obtaining 3D bone geometry and estimating contact forces, validation of these predictions has been limited due to the lack of direct in vivo measurements and the economic and ethical constraints associated with available alternatives. In this study, an existing commercial surgical training station was transformed into a sensorized test bench to replicate a knee subject to a total knee replacement. The original knee inserts of the training station were replaced with personalized 3D-printed bones incorporating their corresponding implants, and multiple sensors with their respective supports were added. The recorded movement of the patella was used in combination with the forces recorded by the pressure sensor and the load cells, to validate the results obtained from the simulation, which was performed by means of a multibody dynamics formulation implemented in a custom-developed library. The utilization of 3D-printed models and sensors facilitated cost-effective and replicable experimental validation of computational simulations, thereby advancing orthopedic surgery while circumventing ethical concerns.
Collapse
Affiliation(s)
- Florian Michaud
- Laboratory of Mechanical Engineering, Centro de Investigación en Tecnologías Navales e Industriales (CITENI), Campus Industrial de Ferrol, University of La Coruña, 15403 Ferrol, Spain; (F.M.); (D.D.); (J.C.)
| | | | | | | |
Collapse
|
2
|
Sass JO, Johnson K, Darques JB, Buerstenbinder L, Soodmand I, Bader R, Kebbach M. Influence of posterior cruciate ligament tension on tibiofemoral and patellofemoral joint contact mechanics in cruciate-retaining total knee replacement: a combined musculoskeletal multibody and finite-element simulation. Comput Methods Biomech Biomed Engin 2024:1-13. [PMID: 38511844 DOI: 10.1080/10255842.2024.2329946] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Accepted: 03/08/2024] [Indexed: 03/22/2024]
Abstract
The influence of posterior cruciate ligament (PCL) tension on the clinical outcome of cruciate-retaining total knee replacement (CR-TKR) remains controversial. Various numerical approaches have been used to study this influence systematically, but the models used are limited by certain assumptions and simplifications. Therefore, the objective of this computational study was to develop a combined musculoskeletal multibody and finite-element simulation during a squat motion to 90° knee flexion with a CR-TKR design to overcome previous limitations regarding model inputs. In addition, different PCL tensions (tight, lax, resected) were modeled and the influence on tibiofemoral and resurfaced patellofemoral joint dynamics and contact stresses was evaluated. The effect of the PCL on knee joint dynamics and contact stresses was more pronounced at higher flexion angles. Tibiofemoral joint dynamics were influenced and a tight PCL induced increased posterior femoral translation during flexion. The maximum contact stress in the tibial insert increased from 20.6 MPa to 22.5 MPa for the resected and tightest PCL at 90° knee flexion. Patellofemoral joint dynamics were only slightly affected by PCL tension. However, the maximum contact stress in the patellar component decreased from 58.0 MPa to 53.7 MPa for the resected and tightest PCL at 90° knee flexion. The combination of musculoskeletal multibody and finite-element simulation is a sufficient method to comprehensively investigate knee joint dynamics and contact stresses in CR-TKR. The PCL tension after CR-TKR affects joint dynamics and contact stresses at the articulating implant surfaces.
Collapse
Affiliation(s)
- Jan-Oliver Sass
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Center, Rostock, Germany
| | - Kurt Johnson
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Center, Rostock, Germany
| | - Jean-Baptiste Darques
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Center, Rostock, Germany
- Polytech Marseille, école d'ingénieurs d'Aix Marseille Université, Marseille, France
| | - Lucas Buerstenbinder
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Center, Rostock, Germany
| | - Iman Soodmand
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Center, Rostock, Germany
| | - Rainer Bader
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Center, Rostock, Germany
| | - Maeruan Kebbach
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
3
|
Yang B, Yuan FZ, Wang HJ, Gong X, Chang YH, Yu JK. Femoral anterior condyle height decreases as the distal anteroposterior size increases in total knee arthroplasty: A comparative study. PLoS One 2024; 19:e0297634. [PMID: 38408088 PMCID: PMC10896507 DOI: 10.1371/journal.pone.0297634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Accepted: 01/08/2024] [Indexed: 02/28/2024] Open
Abstract
PURPOSE The anterior flange height of the current femoral component increases with an increasing distal femoral anteroposterior dimension. During total knee arthroplasty (TKA), we have observed that a large femur may have a thinner anterior condyle, whereas a small femur may have a thicker anterior condyle. The first purpose of this study was to examine whether the femoral anterior condyle height decreases as the distal femoral anteroposterior size increases and whether gender differences exist in anterior condyle height. METHODS A total of 1218 knees undergoing TKA intraoperative and computed tomography scans from 303 healthy knees were used to measure the anterior lateral condylar height (ALCH), anterior medial condylar height (AMCH), and the lateral anteroposterior (LAP) and medial anteroposterior (MAP) dimensions of distal femurs. The LAP and MAP measurements were used for adjustments to determine whether gender differences exist in anterior condyle heights. Linear regression analysis was performed to determine correlations between ALCH and LAP or between AMCH and MAP. RESULTS There were significant differences between males and females in ALCH in both the CT and TKA groups and AMCH in the CT group (all P<0.01). After adjusting for LAP and MAP, there were significant gender differences in the lateral and medial condylar heights in both groups (P<0.01). There were significant negative correlations between ALCH and LAP values and between AMCH and MAP values in both CT and TKA measurements, with the LAP and MAP values increasing as ALCH and AMCH decreased. CONCLUSIONS The results demonstrate that femoral anterior condylar height decreased with increasing anteroposterior dimension in both the medial and lateral condyle. In addition, this study also showed that anterior condylar heights are highly variable, with gender differences. The data may provide an important reference for designing femoral anterior flange thickness to precisely match the natural anterior condylar anatomy.
Collapse
Affiliation(s)
- Bo Yang
- Sports Medicine Department, Beijing Key Laboratory of Sports Injuries, Peking University Third Hospital, Beijing, China
- Department of Orthopaedics, Shaanxi Provincial People's Hospital, The Third Affiliated hospital of Xi'an jiaotong University, Xi'an, China
| | - Fu-Zhen Yuan
- Sports Medicine Department, Beijing Key Laboratory of Sports Injuries, Peking University Third Hospital, Beijing, China
| | - Hai-Jun Wang
- Sports Medicine Department, Beijing Key Laboratory of Sports Injuries, Peking University Third Hospital, Beijing, China
| | - Xi Gong
- Sports Medicine Department, Beijing Key Laboratory of Sports Injuries, Peking University Third Hospital, Beijing, China
| | - Yan-Hai Chang
- Department of Orthopaedics, Shaanxi Provincial People's Hospital, The Third Affiliated hospital of Xi'an jiaotong University, Xi'an, China
| | - Jia-Kuo Yu
- Sports Medicine Department, Beijing Key Laboratory of Sports Injuries, Peking University Third Hospital, Beijing, China
- Orthopaedic Sports Medicine Center, Beijing Tsinghua Changgung Hospital, Affiliated Hospital of Tsinghua University, Changping District, Beijing, China
| |
Collapse
|
4
|
Michaud F, Luaces A, Mouzo F, Cuadrado J. Use of patellofemoral digital twins for patellar tracking and treatment prediction: comparison of 3D models and contact detection algorithms. Front Bioeng Biotechnol 2024; 12:1347720. [PMID: 38481569 PMCID: PMC10935559 DOI: 10.3389/fbioe.2024.1347720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Accepted: 02/13/2024] [Indexed: 03/17/2024] Open
Abstract
Introduction: Poor patellar tracking can result in painful contact pressures, patella subluxation, or dislocation. The use of musculoskeletal models and simulations in orthopedic surgeries allows for objective predictions of post-treatment function, empowering clinicians to explore diverse treatment options for patients. Although a promising approach for managing knee surgeries, the high computational cost of the Finite Element Method hampers its clinical usability. In anticipation of minimal elastic deformations in the involved bodies, the exploration of the Multibody Dynamics approach emerged as a viable solution, providing a computationally efficient methodology to address clinical concerns related to the knee joint. Methods: This work, with a focus on high-performance computing, achieved the simulation of the patellofemoral joint through rigid-body multibody dynamics formulations. A comparison was made between two collision detection algorithms employed in the simulation of contact between the patellar and femoral implants: a generic mesh-to-mesh collision detection algorithm, which identifies potential collisions between bodies by checking for proximity or overlap between their discretized mesh surface elements, and an analytical contact algorithm, which uses a mathematical model to provide closed-form solutions for specific contact problems, but cannot handle arbitrary geometries. In addition, different digital twins (3D model geometries) of the femoral implant were compared. Results: Computational efficiency was considered, and histories of position, orientation, and contact force of the patella during the motion were compared with experimental measurements obtained from a sensorized 3D-printed test bench under pathological and treatment scenarios. The best results were achieved through a purely analytical contact detection algorithm, allowing for clinical usability and optimization of clinical outcomes.
Collapse
Affiliation(s)
- Florian Michaud
- Laboratory of Mechanical Engineering, CITENI, Campus Industrial de Ferrol, University of La Coruña, Ferrol, Spain
| | | | | | | |
Collapse
|
5
|
Henke P, Ruehrmund L, Bader R, Kebbach M. Exploration of the Advanced VIVO TM Joint Simulator: An In-Depth Analysis of Opportunities and Limitations Demonstrated by the Artificial Knee Joint. Bioengineering (Basel) 2024; 11:178. [PMID: 38391664 PMCID: PMC10886281 DOI: 10.3390/bioengineering11020178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 01/31/2024] [Accepted: 02/09/2024] [Indexed: 02/24/2024] Open
Abstract
In biomechanical research, advanced joint simulators such as VIVOTM offer the ability to test artificial joints under realistic kinematics and load conditions. Furthermore, it promises to simplify testing with advanced control approaches and the ability to include virtual ligaments. However, the overall functionality concerning specific test setup conditions, such as the joint lubrication or control algorithm, has not been investigated in-depth so far. Therefore, the aim of this study was to analyse the basic functionality of the VIVOTM joint simulator with six degrees of freedom in order to highlight its capabilities and limitations when testing a total knee endoprostheses using a passive flexion-extension movement. For this, different test setup conditions were investigated, e.g., the control method, repeatability and kinematic reproducibility, waveform frequency, lubrication, and implant embedding. The features offered by the VIVOTM joint simulator are useful for testing joint endoprostheses under realistic loading scenarios. It was found that the results were highly influenced by the varying test setup conditions, although the same mechanical load case was analysed. This study highlights the difficulties encountered when using six degrees of freedom joint simulators, contributes to their understanding, and supports users of advanced joint simulators through functional and tribological analysis of joint endoprostheses.
Collapse
Affiliation(s)
- Paul Henke
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, 18057 Rostock, Germany
| | - Leo Ruehrmund
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, 18057 Rostock, Germany
| | - Rainer Bader
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, 18057 Rostock, Germany
| | - Maeruan Kebbach
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Doberaner Straße 142, 18057 Rostock, Germany
| |
Collapse
|
6
|
Guitteny S, Aissaoui R, Dumas R. Can a Musculoskeletal Model Adapted to Knee Implant Geometry Improve Prediction of 3D Contact Forces and Moments? Ann Biomed Eng 2023:10.1007/s10439-023-03216-y. [PMID: 37101092 DOI: 10.1007/s10439-023-03216-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Accepted: 04/19/2023] [Indexed: 04/28/2023]
Abstract
Tibiofemoral contact loads are crucial parameters in the onset and progression of osteoarthrosis. While contact loads are frequently estimated from musculoskeletal models, their customization is often limited to scaling musculoskeletal geometry or adapting muscle lines. Moreover, studies have usually focused on superior-inferior contact force without investigating three-dimensional contact loads. Using experimental data from six patients with instrumented total knee arthroplasty (TKA), this study customized a lower limb musculoskeletal model to consider the positioning and the geometry of the implant at knee level. Static optimization was performed to estimate tibiofemoral contact forces and contact moments as well as musculotendinous forces. Predictions from both a generic and a customized model were compared to the instrumented implant measurements. Both models accurately predict superior-inferior (SI) force and abduction-adduction (AA) moment. Notably, the customization improves prediction of medial-lateral (ML) force and flexion-extension (FE) moments. However, there is subject-dependent variability in the prediction of anterior-posterior (AP) force. The customized models presented here predict loads on all joint axes and in most cases improve prediction. Unexpectedly, this improvement was more limited for patients with more rotated implants, suggesting a need for further model adaptations such as muscle wrapping or redefinition of hip and ankle joint centers and axes.
Collapse
Affiliation(s)
- Sacha Guitteny
- Univ Lyon, Univ Claude Bernard Lyon 1, Univ Gustave Eiffel, LBMC UMR_T 9406, 69622, Lyon, France
| | - Rachid Aissaoui
- Laboratoire de Recherche en Imagerie Et Orthopédie (LIO), Département Génie des Systèmes, Ecole de Technologie Supérieure, Montréal, Canada
| | - Raphael Dumas
- Univ Lyon, Univ Claude Bernard Lyon 1, Univ Gustave Eiffel, LBMC UMR_T 9406, 69622, Lyon, France.
| |
Collapse
|
7
|
Tischer T, Geier A, Lutter C, Enz A, Bader R, Kebbach M. Patella height influences patellofemoral contact and kinematics following cruciate-retaining total knee replacement. J Orthop Res 2023; 41:793-802. [PMID: 35949157 DOI: 10.1002/jor.25425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Revised: 06/02/2022] [Accepted: 08/09/2022] [Indexed: 02/04/2023]
Abstract
The role of patella height is discussed controversially in total knee arthroplasty (TKA). Therefore, this computational study aims to systematically analyze the biomechanical effect of different patella heights on patellofemoral (PF) forces and kinematics after cruciate-retaining (CR) TKA. We implemented a CR bicondylar TKA with a dome patellar button in a validated dynamic musculoskeletal multibody model of a male human knee joint. Retropatellar dynamics (contact force [N], shear force [N], patellar shift [mm], tilt [°], and rotation [°]) were evaluated during dual-limb squat motion (flexion from 0° to 90°) with simulated active muscle forces and the effects of different patella heights (Blackburne-Peel [BP] ratio of 0.39, 0.49, 0.65, 0.85, 1.01, and 1.1 were systematically examined). As active knee flexion increased, PF contact force also increased. Patella alta (BP = 1.1) resulted in higher PF contact forces compared to normal patella height (BP = 0.65) by up to 16%. Contrarily, patella baja was associated with decreased PF forces by 7%. Compared to patella baja (BP = 0.39), patella alta (BP = 1.1) considerably increased the contact force by up to 25%. Different patellar heights mainly affected PF shear forces during early knee flexion. Concerning PF kinematics, patella alta (BP = 1.1) yielded a greater lateral tilt of more than 4° and higher patellar rotation by up to 3° during deep knee flexion, compared to normal patella height (BP = 0.65). Our computational study indicates that patella alta is associated with the highest PF contact and shear force after the implantation of a CR bicondylar TKA. This should be considered in PF disorders following TKA.
Collapse
Affiliation(s)
- Thomas Tischer
- Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Andreas Geier
- Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Christoph Lutter
- Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Andreas Enz
- Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Rainer Bader
- Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| | - Maeruan Kebbach
- Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
8
|
Kebbach M, Geier A, Darowski M, Krueger S, Schilling C, Grupp TM, Bader R. Computer-based analysis of different component positions and insert thicknesses on tibio-femoral and patello-femoral joint dynamics after cruciate-retaining total knee replacement. Knee 2023; 40:152-165. [PMID: 36436384 DOI: 10.1016/j.knee.2022.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 08/29/2022] [Accepted: 11/03/2022] [Indexed: 11/27/2022]
Abstract
BACKGROUND Positioning of the implant components and tibial insert thickness constitute critical aspects of total knee replacement (TKR) that influence the postoperative knee joint dynamics. This study aimed to investigate the impact of implant component positioning (anterior-posterior and medio-lateral shift) and varying tibial insert thickness on the tibio-femoral (TF) and patello-femoral (PF) joint kinematics and contact forces after cruciate-retaining (CR)-TKR. METHOD A validated musculoskeletal multibody simulation (MMBS) model with a fixed-bearing CR-TKR during a squat motion up to 90° knee flexion was deployed to calculate PF and TF joint dynamics for varied implant component positions and tibial insert thicknesses. Evaluation was performed consecutively by comparing the respective knee joint parameters (e.g. contact force, quadriceps muscle force, joint kinematics) to a reference implant position. RESULTS The PF contact forces were mostly affected by the anterior-posterior as well as medio-lateral positioning of the femoral component (by 3 mm anterior up to 31 % and by 6 mm lateral up to 14 %). TF contact forces were considerably altered by tibial insert thickness (24 % in case of + 4 mm increase) and by the anterior-posterior position of the femoral component (by 3 mm posterior up to 16 %). Concerning PF kinematics, a medialised femoral component by 6 mm increased the lateral patellar tilt by more than 5°. CONCLUSIONS Our results indicate that regarding PF kinematics and contact forces the positioning of the femoral component was more critical than the tibial component. The positioning of the femoral component in anterior-posterior direction on and PF contact force was evident. Orthopaedic surgeons should strictly monitor the anterior-posterior as well as the medio-lateral position of the femoral component and the insert thickness.
Collapse
Affiliation(s)
- Maeruan Kebbach
- Department of Orthopaedics, Rostock University Medical Center, Germany.
| | - Andreas Geier
- Department of Orthopaedics, Rostock University Medical Center, Germany; Department of Modern Mechanical Engineering, Waseda University, Tokyo, Japan
| | - Martin Darowski
- Department of Orthopaedics, Rostock University Medical Center, Germany
| | - Sven Krueger
- Aesculap AG, Research and Development, Tuttlingen, Germany
| | | | - Thomas M Grupp
- Aesculap AG, Research and Development, Tuttlingen, Germany; Ludwig Maximilians University Munich, Department of Orthopaedic Surgery, Physical Medicine and Rehabilitation, Campus Grosshadern, Munich, Germany
| | - Rainer Bader
- Department of Orthopaedics, Rostock University Medical Center, Germany
| |
Collapse
|
9
|
陈 瑱, 张 志, 高 永, 张 静, 郭 磊, 靳 忠. [Musculoskeletal multibody dynamics investigation of posterior-stabilized total knee prosthesis]. SHENG WU YI XUE GONG CHENG XUE ZA ZHI = JOURNAL OF BIOMEDICAL ENGINEERING = SHENGWU YIXUE GONGCHENGXUE ZAZHI 2022; 39:651-659. [PMID: 36008328 PMCID: PMC10957355 DOI: 10.7507/1001-5515.202203023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 04/24/2022] [Indexed: 06/15/2023]
Abstract
Posterior-stabilized total knee prostheses have been widely used in orthopedic clinical treatment of knee osteoarthritis, but the patients and surgeons are still troubled by the complications, for example severe wear and fracture of the post, as well as prosthetic loosening. Understanding the in vivo biomechanics of knee prostheses will aid in the decrease of postoperative prosthetic revision and patient dissatisfaction. Therefore, six different designs of posterior-stabilized total knee prostheses were used to establish the musculoskeletal multibody dynamics models of total knee arthroplasty respectively, and the biomechanical differences of six posterior-stabilized total knee prostheses were investigated under three simulated physiological activities: walking, right turn and squatting. The results showed that the post contact forces of PFC Sigma and Scorpio NGR prostheses were larger during walking, turning right, and squatting, which may increase the risk of the fracture and wear as well as the early loosening. The post design of Gemini SL prosthesis was more conductive to the knee internal-external rotation and avoided the edge contact and wear. The lower conformity design in sagittal plane and the later post-cam engagement resulted in the larger anterior-posterior translation. This study provides a theoretical support for guiding surgeon selection, improving posterior-stabilized prosthetic design and reducing the prosthetic failure.
Collapse
Affiliation(s)
- 瑱贤 陈
- 长安大学 工程机械学院(西安 710064)School of Construction Machinery, Chang'an University, Xi’an 710064, P. R. China
| | - 志峰 张
- 长安大学 工程机械学院(西安 710064)School of Construction Machinery, Chang'an University, Xi’an 710064, P. R. China
| | - 永昌 高
- 长安大学 工程机械学院(西安 710064)School of Construction Machinery, Chang'an University, Xi’an 710064, P. R. China
| | - 静 张
- 长安大学 工程机械学院(西安 710064)School of Construction Machinery, Chang'an University, Xi’an 710064, P. R. China
| | - 磊 郭
- 长安大学 工程机械学院(西安 710064)School of Construction Machinery, Chang'an University, Xi’an 710064, P. R. China
| | - 忠民 靳
- 长安大学 工程机械学院(西安 710064)School of Construction Machinery, Chang'an University, Xi’an 710064, P. R. China
| |
Collapse
|
10
|
Cherian NJ, Ohnoutka C, Peissig EJ, Hsing TM, Aggarwal A, Keeney JA. Cemented Patellar Implant Malposition: A Non-Issue for the Painful Total Knee Arthroplasty. J Arthroplasty 2022; 37:S859-S863. [PMID: 35151808 DOI: 10.1016/j.arth.2022.02.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 01/24/2022] [Accepted: 02/04/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Non-optimal patellofemoral relationships may influence treatment decisions during revision total knee arthroplasty (TKA). We performed this study to determine whether patellar implant malposition or patellar tilt is associated with inferior patient-reported outcome scores or patient satisfaction after primary TKA. METHODS We identified 396 TKA patients (439 knees) from an institutional registry who had undergone patellar resurfacing, with preoperative and 6-week postoperative radiographs available, and patient-reported outcome measures (PROMs) completed at least 1 year after surgery (mean 505 days). Preoperative patient demographic characteristics, patient-reported expectations, National Institutes of Health - Patient Reported Outcomes Measurements Instrument Systems global health, Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, and University of California Los Angeles activity scores were compared between 60 TKAs performed with non-optimal patellofemoral relationships (36 patellar implant malposition, 24 patellar tilt) and 379 TKAs performed with optimal patellar implant placement. RESULTS There were no differences between the 2 cohorts regarding demographic features, preoperative radiographic disease severity, expectations, and PROMs; or postoperative tibiofemoral component alignment, PROMs, and patient-reported satisfaction (P = .48). Knee Injury and Osteoarthritis Outcome Score for Joint Replacement improved similarly (P = .62) for patients with optimal resurfacing (48.5-77.6 points) and non-optimal resurfacing (47.7-76.6 points). A similar proportion of optimal and suboptimal resurfaced patients reported being satisfied with their TKA (92.7% vs 88.1%, P = .29). CONCLUSION Although suboptimal patellofemoral relationships may prompt treatment considerations during revision TKA, the data obtained from this study do not suggest that patellar implant malposition or patellar tilt independently contribute to postoperative pain, functional limitation, or dissatisfaction. LEVEL OF EVIDENCE This is a level III, retrospective cohort study.
Collapse
Affiliation(s)
- Nathan J Cherian
- Department of Orthopaedic Surgery, University of Missouri, Columbia, MO
| | - Cole Ohnoutka
- Department of Orthopaedic Surgery, University of Missouri, Columbia, MO
| | - Evan J Peissig
- Department of Orthopaedic Surgery, University of Missouri, Columbia, MO
| | - Thomas M Hsing
- Department of Orthopaedic Surgery, University of Missouri, Columbia, MO
| | - Ajay Aggarwal
- Department of Orthopaedic Surgery, University of Missouri, Columbia, MO
| | - James A Keeney
- Department of Orthopaedic Surgery, University of Missouri, Columbia, MO
| |
Collapse
|
11
|
Ren X, Lutter C, Kebbach M, Bruhn S, Yang Q, Bader R, Tischer T. Compensatory Responses During Slip-Induced Perturbation in Patients With Knee Osteoarthritis Compared With Healthy Older Adults: An Increased Risk of Falls? Front Bioeng Biotechnol 2022; 10:893840. [PMID: 35782515 PMCID: PMC9240265 DOI: 10.3389/fbioe.2022.893840] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Accepted: 05/30/2022] [Indexed: 02/03/2023] Open
Abstract
Background: Functional impairment of the knee joint affected by osteoarthritis and loss of muscle strength leads to a significant increase in the number of falls. Nevertheless, little is known about strategies for coping with gait perturbations in patients with knee osteoarthritis (KOA). Thus, this study aimed to examine the compensatory strategies of patients with KOA in response to a backward slip perturbation compared with healthy older adults. Methods: An automated perturbation program was developed by using D-Flow software based on the Gait Real-time Analysis Interactive Lab, and an induced backward slip perturbation was implemented on nine patients with severe KOA (68.89 ± 3.59 years) and 15 age-matched healthy older adults (68.33 ± 3.29 years). Step length, gait speed, range of motion, vertical ground reaction forces, lower extremity joint angles, and joint moments were computed and analyzed. Results: Compared with older adults, patients with KOA had significantly lower step length, gait speed, and vertical ground reaction forces in both normal walking and the first recovery step following backward slip perturbations. Inadequate flexion and extension of joint angles and insufficient generation of joint moments predispose patients with KOA to fall. Hip extension angle and flexion moment, knee range of motion, and vertical ground reaction forces are key monitoring variables. Conclusion: The risk of falls for patients with KOA in response to backward slip perturbations is higher. Patients with KOA should focus not only on quadriceps muscle strength related to knee range of motion but also on improving hip extensor strength and activation through specific exercises. Targeted resistance training and perturbation-based gait training could be better options.
Collapse
Affiliation(s)
- Xiping Ren
- College of Physical Education and Health Sciences, Zhejiang Normal University, Jinhua, China
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Center, Rostock, Germany
| | - Christoph Lutter
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Center, Rostock, Germany
| | - Maeruan Kebbach
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Center, Rostock, Germany
| | - Sven Bruhn
- Institute of Sport Science, Faculty of Philosophy, University of Rostock, Rostock, Germany
| | - Qining Yang
- Department of Joint Surgery, The affiliated Jinhua Hospital, Zhejiang University School of Medicine, Jinhua, China
| | - Rainer Bader
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Center, Rostock, Germany
| | - Thomas Tischer
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopedics, Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
12
|
Kinematics and kinetics comparison of ultra-congruent versus medial-pivot designs for total knee arthroplasty by multibody analysis. Sci Rep 2022; 12:3052. [PMID: 35197496 PMCID: PMC8866513 DOI: 10.1038/s41598-022-06909-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Accepted: 02/08/2022] [Indexed: 12/18/2022] Open
Abstract
Nowadays, several configurations of total knee arthroplasty (TKA) implants are commercially available whose designs resulted from clinical and biomechanical considerations. Previous research activities led to the development of the so-called medial-pivot (MP) design. However, the actual benefits of the MP, with respect to other prosthesis designs, are still not well understood. The present work compares the impact of two insert geometries, namely the ultra-congruent (UC) and medial-pivot (MP), on the biomechanical behaviour of a bicondylar total knee endoprosthesis. For this purpose, a multibody model of a lower limb was created alternatively integrating the two implants having the insert geometry discretized. Joint dynamics and contact pressure distributions were evaluated by simulating a squat motion. Results showed a similar tibial internal rotation range of about 3.5°, but an early rotation occurs for the MP design. Furthermore, the discretization of the insert geometry allowed to efficiently derive the contact pressure distributions, directly within the multibody simulation framework, reporting peak pressure values of 33 MPa and 20 MPa for the UC and MP, respectively. Clinically, the presented findings confirm the possibility, through a MP design, to achieve a more natural joint kinematics, consequently improving the post-operative patient satisfaction and potentially reducing the occurrence of phenomena leading to the insert loosening.
Collapse
|
13
|
The Influence of Mathematical Definitions on Patellar Kinematics Representations. MATERIALS 2021; 14:ma14247644. [PMID: 34947239 PMCID: PMC8709478 DOI: 10.3390/ma14247644] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 12/08/2021] [Accepted: 12/09/2021] [Indexed: 12/11/2022]
Abstract
A correlation between patellar kinematics and anterior knee pain is widely accepted. However, there is no consensus on how they are connected or what profile of patellar kinematics would minimize anterior knee pain. Nevertheless, answering this question by merging existing studies is further complicated by the variety of ways to describe patellar kinematics. Therefore, this study describes the most frequently used conventions for defining patellar kinematics, focusing on the rotations. The similarities and differences between the Cardan sequences and angles calculated by projecting axes are analyzed. Additionally, a tool is provided to enable the conversion of kinematic data between definitions in different studies. The choice of convention has a considerable impact on the absolute values and the clinical characteristics of the patello-femoral angles. In fact, the angles that result from using different mathematical conventions to describe a given patello-femoral rotation from our analyses differ up to a Root Mean Squared Error of 111.49° for patellar flexion, 55.72° for patellar spin and 35.39° for patellar tilt. To compare clinical kinematic patello-femoral results, every dataset must follow the same convention. Furthermore, researchers should be aware of the used convention’s implications to ensure reproducibility when interpreting and comparing such data.
Collapse
|
14
|
Bansod YD, Kebbach M, Kluess D, Bader R, van Rienen U. Finite element analysis of bone remodelling with piezoelectric effects using an open-source framework. Biomech Model Mechanobiol 2021; 20:1147-1166. [PMID: 33740158 PMCID: PMC8154825 DOI: 10.1007/s10237-021-01439-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2020] [Accepted: 02/17/2021] [Indexed: 12/16/2022]
Abstract
Bone tissue exhibits piezoelectric properties and thus is capable of transforming mechanical stress into electrical potential. Piezoelectricity has been shown to play a vital role in bone adaptation and remodelling processes. Therefore, to better understand the interplay between mechanical and electrical stimulation during these processes, strain-adaptive bone remodelling models without and with considering the piezoelectric effect were simulated using the Python-based open-source software framework. To discretise numerical attributes, the finite element method (FEM) was used for the spatial variables and an explicit Euler scheme for the temporal derivatives. The predicted bone apparent density distributions were qualitatively and quantitatively evaluated against the radiographic scan of a human proximal femur and the bone apparent density calculated using a bone mineral density (BMD) calibration phantom, respectively. Additionally, the effect of the initial bone density on the resulting predicted density distribution was investigated globally and locally. The simulation results showed that the electrically stimulated bone surface enhanced bone deposition and these are in good agreement with previous findings from the literature. Moreover, mechanical stimuli due to daily physical activities could be supported by therapeutic electrical stimulation to reduce bone loss in case of physical impairment or osteoporosis. The bone remodelling algorithm implemented using an open-source software framework facilitates easy accessibility and reproducibility of finite element analysis made.
Collapse
Affiliation(s)
- Yogesh Deepak Bansod
- Institute of General Electrical Engineering, University of Rostock, 18051 Rostock, Germany
| | - Maeruan Kebbach
- Department of Orthopaedics, University Medicine Rostock, 18057 Rostock, Germany
- Department Life, Light & Matter, University of Rostock, 18051 Rostock, Germany
| | - Daniel Kluess
- Department of Orthopaedics, University Medicine Rostock, 18057 Rostock, Germany
- Department Life, Light & Matter, University of Rostock, 18051 Rostock, Germany
| | - Rainer Bader
- Department of Orthopaedics, University Medicine Rostock, 18057 Rostock, Germany
- Department Life, Light & Matter, University of Rostock, 18051 Rostock, Germany
- Department Ageing of Individuals and Society, University of Rostock, 18051 Rostock, Germany
| | - Ursula van Rienen
- Institute of General Electrical Engineering, University of Rostock, 18051 Rostock, Germany
- Department Life, Light & Matter, University of Rostock, 18051 Rostock, Germany
- Department Ageing of Individuals and Society, University of Rostock, 18051 Rostock, Germany
| |
Collapse
|
15
|
Special Issue "Novel Research about Biomechanics and Biomaterials Used in Hip, Knee and Related Joints". MATERIALS 2021; 14:ma14092222. [PMID: 33925899 PMCID: PMC8123477 DOI: 10.3390/ma14092222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Download PDF] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Accepted: 04/25/2021] [Indexed: 12/03/2022]
|
16
|
Oefner C, Herrmann S, Kebbach M, Lange HE, Kluess D, Woiczinski M. Reporting checklist for verification and validation of finite element analysis in orthopedic and trauma biomechanics. Med Eng Phys 2021; 92:25-32. [PMID: 34167708 DOI: 10.1016/j.medengphy.2021.03.011] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 02/11/2021] [Accepted: 03/29/2021] [Indexed: 10/21/2022]
Abstract
Finite element analysis (FEA) has become a fundamental tool for biomechanical investigations in the last decades. Despite several existing initiatives and guidelines for reporting on research methods and results, there are still numerous issues that arise when using computational models in biomechanical investigations. According to our knowledge, these problems and controversies lie mainly in the verification and validation (V&V) process as well as in the set-up and evaluation of FEA. This work aims to introduce a checklist including a report form defining recommendations for FEA in the field of Orthopedic and Trauma (O&T) biomechanics. Therefore, a checklist was elaborated which summarizes and explains the crucial methodologies for the V&V process. In addition, a report form has been developed which contains the most important steps for reporting future FEA. An example of the report form is shown, and a template is provided, which can be used as a uniform basis for future documentation. The future application of the presented report form will show whether serious errors in biomechanical investigations using FEA can be minimized by this checklist. Finally, the credibility of the FEA in the clinical area and the scientific exchange in the community regarding reproducibility and exchangeability can be improved.
Collapse
Affiliation(s)
- Christoph Oefner
- Center for Research on Musculoskeletal Systems, Faculty of Medicine, Leipzig University, Semmelweisstrasse 14, 04103 Leipzig, Germany; Department of Orthopaedic Surgery, Traumatology and Plastic Surgery, Leipzig University, Liebigstrasse 18, 04103 Leipzig, Germany; Faculty of Engineering Sciences, Leipzig University of Applied Sciences, Karl-Liebknecht-Strasse 134, 04277 Leipzig, Germany.
| | - Sven Herrmann
- Institute for Biomechanics, BG Unfallklinik, Prof.-Küntscher-Strasse 8, 82418 Murnau am Staffelsee, Germany; Institute for Biomechanics, Paracelsus Medical University Salzburg (Austria), Prof.-Küntscher-Strasse 8, 82418 Murnau am Staffelsee, Germany
| | - Maeruan Kebbach
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Doberaner Strasse 142, 18057 Rostock, Germany
| | - Hans-E Lange
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Doberaner Strasse 142, 18057 Rostock, Germany
| | - Daniel Kluess
- Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, Rostock University Medical Center, Doberaner Strasse 142, 18057 Rostock, Germany
| | - Matthias Woiczinski
- Department of Orthopaedics, Physical Medicine and Rehabilitation, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany
| |
Collapse
|
17
|
Mercader A, Röttinger T, Bigdeli A, Lüth TC, Röttinger H. A patient-specific 3D model of the knee to compare the femoral rollback before and after total knee arthroplasty (TKA). J Exp Orthop 2021; 8:2. [PMID: 33394191 PMCID: PMC7782601 DOI: 10.1186/s40634-020-00319-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Accepted: 12/03/2020] [Indexed: 12/21/2022] Open
Abstract
Purpose Total knee arthroplasty (TKA) is nowadays performed as a standard procedure on a large number of patients suffering from arthrosis. Replacing the knee joint causes changes in the geometry and kinematics of the knee, which are unique to each individual. This research focuses on the method to detect these changes after TKA and on the impact on the knee movement. This approach could reduce complications in patients with post-operative pain and reduce the number of revisions. Methods A 3D model of a patient’s knee was made by measuring the movement with a medically certified infrared stereo camera. This measurement was combined with the 3D model of the patient’s bones, previously segmented from the CT scan. This model is printed in 3D, one part being the mechanism that follows the movement of the patient, and the other part being the 3D copy of the femur and tibia bones. The knee replacement operation is performed directly on the model and the resulting rollback is being measured before and after TKA. Results We observe a difference in the rollback before and after TKA on the 3D printed model. The variation in size and shape of the femoral implant compared to the natural femur condyles is one of the reasons for the changes in the rollback effect. The rollback is half as large after the prosthesis insertion, which confirms the fact that the femoral prosthesis geometry influences the knee kinematics. Conclusions In this study, a first 3D model combining the patient-specific kinematic and the geometry of his bones has been constructed. This model allows the surgeon to validate the plan of the operation, but also to understand the problems and consequences generated by the prosthesis insertion. The rollback is one of the most important motion of the knee joint and this behavior could be quantified, providing comparative analysis of the knee joint before and after the operation. As a future study, the model could be used to analyse more parameters of the TKA such as the impact of different implantation methods. Supplementary Information The online version contains supplementary material available at 10.1186/s40634-020-00319-6.
Collapse
Affiliation(s)
- Alexandra Mercader
- Technical University of Munich, Boltzmannstraße 15, 85748, Garching bei München, Germany
| | - Timon Röttinger
- The Munich Center for Arthroplasty, Chirurgisches Klinikum München Süd Am Isarkanal 30, 81379, Munich, Germany
| | - Amir Bigdeli
- The Munich Center for Arthroplasty, Chirurgisches Klinikum München Süd Am Isarkanal 30, 81379, Munich, Germany
| | - Tim C Lüth
- Technical University of Munich, Boltzmannstraße 15, 85748, Garching bei München, Germany
| | - Heinz Röttinger
- The Munich Center for Arthroplasty, Chirurgisches Klinikum München Süd Am Isarkanal 30, 81379, Munich, Germany.
| |
Collapse
|