1
|
Tribst JPM, Dal Piva AMDO, Muris J, Kleverlaan CJ, Feilzer AJ. One-piece endodontic crown fixed partial denture: Is it possible? J Prosthet Dent 2024; 131:1118-1125. [PMID: 36801103 DOI: 10.1016/j.prosdent.2023.01.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 01/18/2023] [Accepted: 01/18/2023] [Indexed: 02/18/2023]
Abstract
STATEMENT OF PROBLEM Whether the replacement of a missing tooth with a fixed partial denture supported by an endodontically treated abutment could be improved with 1-piece endodontic crowns is unclear. PURPOSE The purpose of the study was to evaluate the mechanical behavior of a fixed partial denture (FPD) according to the preparation of the abutment teeth (1-piece endodontic crown or complete crown) in terms of stress magnitude in the prosthesis, cement layer, and tooth. MATERIAL AND METHODS A posterior model with 2 abutment teeth (first molar and first premolar) was modeled with a computer-aided design (CAD) software program for conducting a 3-dimensional finite element analysis (FEA). To replace the missing second premolar, the model was replicated in different possible FPDs according to the abutment preparation design (complete crown [Conventional], 2 1-piece endodontic crowns [EC]) or a 1-piece endodontic crown on one of the abutment teeth (first molar [ECM] and first premolar [ECP]) for a total of 4 designs. All FPDs were in lithium disilicate. The solids were imported to an analysis software program (ANSYS 19.2) in the standard for the exchange of product data (STEP) format. The mechanical properties were considered isotropic and the materials to show linear elastic and homogeneous behavior. An axial load (300 N) was applied at the occlusal surface of the pontic. The results were evaluated by colorimetric stress maps of von Mises and maximum principal stress in the prosthesis, maximum principal stress and shear stresses on the cement layer, and maximum principal stress in the abutment teeth. RESULTS The von Mises stresses revealed that all FPD designs behaved similarly and that, considering the maximum principal stress criteria, the pontic was the most stressed region. For the cement layer, the combined designs presented an intermediate behavior, with the ECM more suitable to reducing the stress peak. The conventional preparation allowed less stress concentration in both teeth, and higher stress concentration in the premolar was observed with a 1-piece endodontic crown. The 1-piece endodontic crown decreased the risk of fracture failure. Considering the risk of debonding failure for the prosthesis, the 1-piece endodontic crown preparation was only able to decrease the failure risk when the EC design was used and when only the shear stress was considered. CONCLUSIONS Performing 1-piece endodontic crown preparations to retain a 3-unit lithium disilicate FPD is an alternative to conventional complete crown preparations.
Collapse
Affiliation(s)
- João Paulo M Tribst
- Assistant Professor, Department of Oral Regenerative Medicine, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, the Netherlands
| | - Amanda Maria de O Dal Piva
- Assistant Professor, Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, the Netherlands.
| | - Joris Muris
- Assistant Professor, Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, the Netherlands
| | - Cornelis J Kleverlaan
- Professor, Department of Dental Materials Science, Academic Center for Dentistry Amsterdam (ACTA), University of Amsterdam & Vrije Universiteit, Amsterdam, the Netherlands
| | - Albert J Feilzer
- Professor, Department of Oral Regenerative Medicine, Academic Center for Dentistry Amsterdam (ACTA), University of Amsterdam & Vrije Universiteit, Amsterdam, the Netherlands
| |
Collapse
|
2
|
Al Qahtani WM. Comparative Finite Element Analysis of Endocrowns and Traditional Restorations for Endodontically Treated Mandibular First Molars. Med Sci Monit 2023; 29:e941314. [PMID: 37941316 PMCID: PMC10644702 DOI: 10.12659/msm.941314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Accepted: 08/24/2023] [Indexed: 11/10/2023] Open
Abstract
BACKGROUND This study evaluated 2 endocrown designs and traditional restoration with a conventional crown using post and core to find the best restoration design for endodontically treated mandibular first molars. MATERIAL AND METHODS Three 3D finite element models were constructed: (1) post and core restoration, (2) endocrown butt joint margin design, and (3) endocrown with shoulder finish line. The intact tooth geometry was extracted with computed tomography, then modified to the selected restoration designs. Bone and mucosa geometry was simplified and represented as 3 cylinders. Two loading cases were examined on E-max crowns as 400N and 200N vertically and 45º oblique, respectively, that were located at buccal cusp tips and central fossa by nodal force distributed on circular areas with 0.5-mm diameter in each location. RESULTS Traditional restoration kept crown deformation and stresses at lower levels than did endocrowns. Results of the butt joint margin design were comparable to that of shoulder finish line design. Cement had the lowest stress values under shoulder finish line design, while the remaining tooth indicated the superiority of butt joint margin design, with less stresses by 20% and 24%, compared with traditional and shoulder finish line restorations, respectively. CONCLUSIONS The 3 tested restoration designs worked well. Although the differences were small, according to stress analysis results, conventional restoration by post and core achieved the best performance, followed by butt joint margin, which ensures lowest level of stresses on dentine. Finally, the shoulder finish line endocrown can replace the other designs but with higher stress levels.
Collapse
|
3
|
Yoon Y, Lee MJ, Kang I, Oh S. Evaluation of Biomechanical Stability of Teeth Tissue According to Crown Materials: A Three-Dimensional Finite Element Analysis. MATERIALS (BASEL, SWITZERLAND) 2023; 16:4756. [PMID: 37445067 DOI: 10.3390/ma16134756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 06/18/2023] [Accepted: 06/27/2023] [Indexed: 07/15/2023]
Abstract
The biomechanical effects of dental tissue according to various dental crown materials were investigated using finite element analysis. Bone, prepared tooth, root canal, and periodontal ligament were modeled based on computed tomography. Depending on the characteristics of the crown material, it was classified into zirconia, hybrid ceramic, gold alloy, and acrylic resin. A loading force of 200 N was applied in the vertical direction to the occlusal surface of the crown, and analysis was performed under the condition that all interfaces were tied. The results demonstrate that the highest von Mises stress was shown in the prepared tooth of the acrylic resin model, which is a temporary prosthesis, and the pulpal pressure was also the highest. Additionally, among the final prosthesis, the highest stress was shown in the hybrid ceramic model prepared teeth. The properties of restoration materials can be a factor influencing the tooth structure. Thus, in order to make a correct decision when selecting a material for restorative treatment, it is necessary to understand, analyze, and evaluate the properties of these restoration materials.
Collapse
Affiliation(s)
- Youngjae Yoon
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Kyung Hee University, Seoul 02447, Republic of Korea
| | - Myung-Jin Lee
- Department of Dental Hygiene, Division of Health Science, Baekseok University, Cheonan 31065, Republic of Korea
| | - Inyeong Kang
- School of Mechanical Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Sanghwan Oh
- Department of Dental Hygiene, Konyang University, Daejeon 35365, Republic of Korea
| |
Collapse
|
4
|
Aldesoki M, Bourauel C, Morsi T, El-Anwar MI, Aboelfadl AK, Elshazly TM. Biomechanical behavior of endodontically treated premolars restored with different endocrown designs: Finite element study. J Mech Behav Biomed Mater 2022; 133:105309. [DOI: 10.1016/j.jmbbm.2022.105309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 05/31/2022] [Accepted: 06/02/2022] [Indexed: 10/18/2022]
|
5
|
Pantea M, Totan AR, Imre M, Petre AE, Țâncu AMC, Tudos C, Farcașiu AT, Butucescu M, Spînu TC. Biochemical Interaction between Materials Used for Interim Prosthetic Restorations and Saliva. MATERIALS (BASEL, SWITZERLAND) 2021; 15:226. [PMID: 35009373 PMCID: PMC8746092 DOI: 10.3390/ma15010226] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Revised: 12/17/2021] [Accepted: 12/24/2021] [Indexed: 11/23/2022]
Abstract
The purpose of this study was to analyze the oxidative stress level and inflammatory status of saliva in the presence of certain materials used for obtaining interim prosthetic restorations. Four types of interim resin materials were investigated: a pressure/heat-cured acrylic resin (Superpont C+B, SpofaDental a.s Czech Republic, /KaVo Kerr Group), a milled resin (Telio CAD polymethyl methacrylate, Ivoclar Vivadent AG, Liechtenstein), a 3D printed resin (NextDent C&B MFH, NextDent by 3D Systems, the Netherlands), and a pressure/heat-cured micro-filled indirect composite resin (SR Chromasit, Ivoclar Vivadent AG, Liechtenstein). The disk-shaped resin samples (30 mm diameter, 2 mm high) were obtained in line with the producers' recommendations. The resulting resin specimens were incubated with saliva samples collected from twenty healthy volunteers. In order to analyze the antioxidant activity of the tested materials, certain salivary parameters were evaluated before and after incubation: uric acid, gamma glutamyl transferase (GGT), oxidative stress responsive kinase-1 (OXSR-1), and total antioxidant capacity (TAC); the salivary levels of tumor necrosis factor (TNFα) and interleukin-6 (IL-6) (inflammatory markers) were measured as well. The obtained results are overall favorable, showing that the tested materials did not cause significant changes in the salivary oxidative stress level and did not influence the inflammatory salivary status.
Collapse
Affiliation(s)
- Mihaela Pantea
- Department of Fixed Prosthodontics and Occlusology, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 17-23 Plevnei Street, 020221 Bucharest, Romania; (M.P.); (A.E.P.); (T.C.S.)
| | - Alexandra Ripszky Totan
- Department of Biochemistry, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 17-23 Plevnei Street, 020021 Bucharest, Romania;
| | - Marina Imre
- Department of Complete Denture, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 17-23 Plevnei Street, 020221 Bucharest, Romania;
| | - Alexandru Eugen Petre
- Department of Fixed Prosthodontics and Occlusology, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 17-23 Plevnei Street, 020221 Bucharest, Romania; (M.P.); (A.E.P.); (T.C.S.)
| | - Ana Maria Cristina Țâncu
- Department of Complete Denture, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 17-23 Plevnei Street, 020221 Bucharest, Romania;
| | - Cristian Tudos
- Resident in General Dentistry, Emergency Hospital of Saint Pantelimon, 021661 Bucharest, Romania;
| | - Alexandru Titus Farcașiu
- Department of Removable Prosthodontics, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 17-23 Plevnei Street, 020221 Bucharest, Romania;
| | - Mihai Butucescu
- Department of Operative Dentistry, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 17-23 Plevnei Street, 020221 Bucharest, Romania
| | - Tudor Claudiu Spînu
- Department of Fixed Prosthodontics and Occlusology, Faculty of Dental Medicine, “Carol Davila” University of Medicine and Pharmacy, 17-23 Plevnei Street, 020221 Bucharest, Romania; (M.P.); (A.E.P.); (T.C.S.)
| |
Collapse
|
6
|
Stress Concentration of Endodontically Treated Molars Restored with Transfixed Glass Fiber Post: 3D-Finite Element Analysis. MATERIALS 2021; 14:ma14154249. [PMID: 34361443 PMCID: PMC8347937 DOI: 10.3390/ma14154249] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Revised: 06/30/2021] [Accepted: 07/02/2021] [Indexed: 01/08/2023]
Abstract
The loss of dental structure caused by endodontic treatment is responsible for a decrease in tooth resistance, which increases susceptibility to fracture. Therefore, it is important that minimally invasive treatments be performed to preserve the dental structure and increase the resistance to fracture of endodontically treated posterior teeth. To evaluate under axial loads, using the finite element method, the stress distribution in endodontically treated molars restored with both transfixed or vertical glass fiber posts (GFP) and resin composite. An endodontically treated molar 3D-model was analyzed using finite element analyses under four different conditions, class II resin composite (G1, control model), vertical glass fiber post (G2), transfixed glass fiber posts (G3) and vertical and transfixed glass fiber posts (G4). Ideal contacts were considered between restoration/resin composite and resin composite/tooth. An axial load (300 N) was applied to the occlusal surface. The resulting tensile stresses were calculated for the enamel and dentin tissue from five different viewports (occlusal, buccal, palatal, mesial and distal views). According to the stress maps, similar stress trends were observed, regardless of the glass fiber post treatment. In addition, for the G1 model (without GFP), a high-stress magnitude can be noticed in the proximal faces of enamel (7.7 to 14 MPa) and dentin (2.1 to 3.3 MPa) tissue. The use of transfixed glass fiber post is not indicated to reduce the stresses, under axial loads, in both enamel and dentin tissue in endodontically treated molar with a class II cavity.
Collapse
|
7
|
Lithium Disilicate Ceramic Endocrown Biomechanical Response According to Different Pulp Chamber Extension Angles and Filling Materials. MATERIALS 2021; 14:ma14051307. [PMID: 33803194 PMCID: PMC7963147 DOI: 10.3390/ma14051307] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 03/02/2021] [Accepted: 03/04/2021] [Indexed: 12/28/2022]
Abstract
The purpose of this study is to evaluate the effect of pulp chamber extension angles and filling material mechanical properties on the biomechanical response of a ceramic endocrown. A 3D model of maxillary molar that underwent endodontically treatment was exported to computer aided design software to conduct finite element analysis (FEA). The endocrown model was modified considering different pulp chamber extension angles (right angle; 6°, 12° and 18° of axial divergence). The solids were imported into the computer aided engineering software in Standard for the Exchange of Product Data (STEP) format. Nine different filling materials were simulated to seal the orifice of the root canal system under each endocrown restoration (resin composite, bulk-fill resin composite, alkasite, flowable resin composite, glass ionomer cement, autocured resin-reinforced glass ionomer cement, resin cement, bulk-fill flowable resin composite, zinc oxide cement), totaling 36 models. An axial load (300 N) was applied at the occlusal surface. Results were determined by colorimetric graphs of von-Misses stress (VMS) and Maximum Principal Stress (MPS) on tooth, cement layer, and endocrown restorations. VMS distribution showed a similar pattern between the models, with more stress at the load region for the right-angled endocrowns. The MPS showed that the endocrown intaglio surface and cement layer showed different mechanical responses with different filing materials and pulp chamber angles. The stress peaks plotted in the dispersion plot showed that the filling material stiffness is proportional to the stress magnitude in the endocrown, cement layer and tooth adhesive surface. In addition, the higher the pulp chamber preparation angle, the higher the stress peak in the restoration and tooth, and the lower the stress in the cement layer. Therefore, 6° and 12° pulp chamber angles showed more promising balance between the stresses of the adhesive interface structures. Under the conditions of this study, rigid filling materials were avoided to seal the orifice of root canal system when an endocrown restoration was planned as rehabilitation. In addition, the pulp chamber axial walls were prepared between 6° and 12° of divergence to balance the stress magnitude in the adhesive interface for this treatment modality.
Collapse
|
8
|
Influence of Polymeric Restorative Materials on the Stress Distribution in Posterior Fixed Partial Dentures: 3D Finite Element Analysis. Polymers (Basel) 2021; 13:polym13050758. [PMID: 33670991 PMCID: PMC7957672 DOI: 10.3390/polym13050758] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 02/12/2021] [Accepted: 02/12/2021] [Indexed: 01/06/2023] Open
Abstract
Background: This study evaluated the effect of interim restorative materials (acrylic resin (AR), resin composite (RC) or polyetheretherketone (PEEK) for dental computer-aided design/computer-aided manufacturing (CAD/CAM)) on the stress distribution of a posterior three-unit fixed partial denture. Methods: The abutment teeth (first molar and first premolar) were modeled using the BioCAD protocol containing 1.5 mm of axial reduction and converging axial walls. A static structural analysis was performed in the computer-aided engineering software, and the Maximum Principal Stress criterion was used to analyze the prosthesis and the cement layers of both abutment teeth. The materials were considered isotropic, linearly elastic, homogeneous and with bonded contacts. An axial load (600 N) was applied to the occlusal surface of the second premolar. Results: Regardless of the restorative material, the region of the prosthetic connectors showed the highest tensile stress magnitude. The highest stress peak was observed with the use of RC (129 MPa) compared to PEEK and AR. For the cement layers, RC showed the lowest values in the occlusal region (7 MPa) and the highest values for the cervical margin (14 MPa) compared to PEEK (21 and 12 MPa) and AR (21 and 13 MPa). Conclusions: Different interim restorative materials for posterior fixed partial dentures present different biomechanical behavior. The use of resin composite can attenuate the stress magnitude on the cement layer, and the use of acrylic resin can attenuate the stress magnitude on the connector region.
Collapse
|