1
|
Kim J, Park JY, Lee JY, Kim DM, Lee J, Jung UW, Lim YJ, Cha JK. Randomized controlled trial on the efficacy of a custom-made, fully guided implant system for flapless crestal sinus floor elevation: Accuracy and patient-reported outcomes. Clin Oral Implants Res 2024. [PMID: 39101395 DOI: 10.1111/clr.14341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 07/10/2024] [Accepted: 07/23/2024] [Indexed: 08/06/2024]
Abstract
OBJECTIVE To compare fully guided flapless implant surgery using a light-cured surgical guide (FG group) with partially guided open flap surgery (PG group) in the posterior maxilla when performing simultaneous sinus floor elevation in terms of the accuracy, time requirements, and patient/clinician-reported outcomes (PROMs and CROMs). MATERIALS AND METHODS In this study, 56 tissue-level implants were placed with crestal sinus floor elevation in 56 patients at single-tooth sites, with 28 implants allocated to the PG group and 28 to the FG group. The deviations of the placed implants from the virtually planned positions were measured at the implant platform and apex and for the angular deviation. The presurgical preparation time and the duration of surgery were measured. PROMs and CROMs were made by administering questionnaires at multiple time points. RESULTS Horizontal deviations at the platform and apex and the angular deviation were significantly smaller in the FG group than the PG group (p < .05). Presurgical preparation and surgery times were significantly shorter in the FG group (p < .001). Patient satisfaction and willingness to receive repeat treatment were significantly better in the FG group than in the PG group (p < .005 and .025, respectively). Clinicians were more satisfied in the FG group than the PG group (p < .05). CONCLUSION When placing an implant with sinus floor elevation, the flapless approach using a fully guided surgical system can be more accurate, faster, and increase the satisfaction of both the clinician and patient compared to the partially guided surgery.
Collapse
Affiliation(s)
- Jongseung Kim
- Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry, Seoul, South Korea
| | - Jin-Young Park
- Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry, Seoul, South Korea
| | - Joo-Yeon Lee
- Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry, Seoul, South Korea
| | - Da-Mi Kim
- Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry, Seoul, South Korea
| | - Jungwon Lee
- One-Stop Specialty Center, Seoul National University Dental Hospital, Seoul, South Korea
| | - Ui-Won Jung
- Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry, Seoul, South Korea
| | - Young-Jun Lim
- Department of Prosthodontics and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, South Korea
| | - Jae-Kook Cha
- Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry, Seoul, South Korea
- Institute for Innovation in Digital Healthcare, Yonsei University, Seoul, South Korea
| |
Collapse
|
2
|
Song YW, Yoo SH, Jung UW. Effects of a modified surgical protocol on the positional accuracy of dental implants placed using fully guided implant surgery in the partially edentulous posterior ridge with distal extension: a dentiform model study. J Adv Prosthodont 2024; 16:1-11. [PMID: 38455680 PMCID: PMC10917626 DOI: 10.4047/jap.2024.16.1.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 01/02/2024] [Accepted: 02/06/2024] [Indexed: 03/09/2024] Open
Abstract
PURPOSE The present experiment aimed to evaluate the placement accuracy of fully guided implant surgery using a mucosa-supported surgical guide when the protocol of osteotomy and installation was modified (MP) compared to when the protocol was sequentially and conventionally carried out (CP). MATERIALS AND METHODS For 24 mandibular dentiform models, 12 dentists (6 experts and 6 beginners) performed fully guided implant placements two times at the right first and second molar sites using a mucosa-supported surgical guide, once by the CP (CP group) and at the other time by the MP (MP group). The presurgical and postsurgical stereolithographic images were superimposed, and the deviations between the virtually planned and actually placed implant positions and the procedure time were compared statistically (P < .05). RESULTS The accuracies were similar in the CP and MP groups. In the CP group, the mean platform and apex deviations at the second molar site for the beginners were +0.75 mm and +1.14 mm, respectively, which were significantly larger than those for the experts (P < .05). In the MP group, only the mean vertical deviation at the second molar site for the beginners (+0.53 mm) was significantly larger than that for the experts (P < .05). The procedure time was significantly longer for the MP group (+94.0 sec) than for the CP group (P < .05). CONCLUSION In fully guided implant surgery using a mucosa-supported guide, the MP may improve the placement accuracy when compared to the CP, especially at sites farther from the most-posterior natural tooth.
Collapse
Affiliation(s)
- Young Woo Song
- Department of Periodontology, Dental Hospital, Veterans Health Service Medical Center, Seoul, Republic of Korea
| | - Seung Ha Yoo
- Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Ui-Won Jung
- Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry, Seoul, Republic of Korea
| |
Collapse
|
3
|
Takács A, Hardi E, Cavalcante BGN, Szabó B, Kispélyi B, Joób-Fancsaly Á, Mikulás K, Varga G, Hegyi P, Kivovics M. Advancing accuracy in guided implant placement: A comprehensive meta-analysis: Meta-Analysis evaluation of the accuracy of available implant placement Methods. J Dent 2023; 139:104748. [PMID: 37863173 DOI: 10.1016/j.jdent.2023.104748] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 10/16/2023] [Accepted: 10/18/2023] [Indexed: 10/22/2023] Open
Abstract
OBJECTIVES This meta-analysis aimed to determine the accuracy of currently available computer-assisted implant surgery (CAIS) modalities under in vitro conditions and investigate whether these novel techniques can achieve clinically acceptable accuracy. DATA In vitro studies comparing the postoperative implant position with the preoperative plan were included. Risk of bias was assessed using the Quality Assessment Tool For In Vitro Studies (QUIN Tool) and a sensitivity analysis was conducted using funnel plots. SOURCES A systematic search was performed on April 18, 2023, using the following three databases: MEDLINE (via PubMed), EMBASE, and Cochrane Central Register of Controlled Trials. No filters or restrictions were applied during the search. RESULTS A total of 5,894 studies were included following study selection. Robotic- and static CAIS (sCAIS) had the most accurate and clinically acceptable outcomes. sCAIS was further divided according to the guidance level. Among the sCAIS groups, fully guided implant placement had the greatest accuracy. Augmented reality-based CAIS (AR-based CAIS) had clinically acceptable results for all the outcomes except for apical global deviation. Dynamic CAIS (dCAIS) demonstrated clinically safe results, except for horizontal apical deviation. Freehand implant placement was associated with the greatest number of errors. CONCLUSIONS Fully guided sCAIS demonstrated the most predictable outcomes, whereas freehand sCAIS demonstrated the lowest accuracy. AR-based and robotic CAIS may be promising alternatives. CLINICAL SIGNIFICANCE To our knowledge, this is the first meta-analysis to evaluate the accuracy of robotic CAIS and investigate the accuracy of various CAIS modalities.
Collapse
Affiliation(s)
- Anna Takács
- Department of Community Dentistry, Semmelweis University, Szentkirályi utca 40. 1088 Budapest, Hungary; Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary
| | - Eszter Hardi
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary; Department of Oro-Maxillofacial Surgery and Stomatology, Semmelweis University, Mária utca 52. 1085 Budapest, Hungary
| | - Bianca Golzio Navarro Cavalcante
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary; Department of Oral Biology, Semmelweis University, Nagyvárad tér 4. 1089 Budapest, Hungary
| | - Bence Szabó
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary
| | - Barbara Kispélyi
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Szentkirályi utca 47. 1088 Budapest, Hungary
| | - Árpád Joób-Fancsaly
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary; Department of Oro-Maxillofacial Surgery and Stomatology, Semmelweis University, Mária utca 52. 1085 Budapest, Hungary
| | - Krisztina Mikulás
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Szentkirályi utca 47. 1088 Budapest, Hungary
| | - Gábor Varga
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary; Department of Oral Biology, Semmelweis University, Nagyvárad tér 4. 1089 Budapest, Hungary
| | - Péter Hegyi
- Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary; Institute for Translational Medicine, Szentágothai Research Centre, Medical School, University of Pécs, Szigeti út 12. 7624 Pécs, Hungary; Division of Pancreatic Diseases, Heart and Vascular Center, Semmelweis University, Városmajor utca 68. 1122 Budapest, Hungary
| | - Márton Kivovics
- Department of Community Dentistry, Semmelweis University, Szentkirályi utca 40. 1088 Budapest, Hungary; Centre for Translational Medicine, Semmelweis University, Üllői út 26. 1085 Budapest, Hungary.
| |
Collapse
|
4
|
Htay PEE, Leesungbok R, Lee SW, Jee YJ, Kang KL, Hong SO. Reliability of a chairside CAD-CAM surgical guide for dental implant surgery on the anterior maxilla: An in vitro study. J Adv Prosthodont 2023; 15:259-270. [PMID: 37936833 PMCID: PMC10625886 DOI: 10.4047/jap.2023.15.5.259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 10/20/2023] [Accepted: 10/25/2023] [Indexed: 11/09/2023] Open
Abstract
PURPOSE This study evaluated the reliability of the chair-side CAD-CAM surgical guide (CSG) in the anterior maxilla by comparing its accuracy with the laboratory 3D-printed surgical guide (3DSG) and manual surgical guide (MSG) concerning different levels of dentists' surgical experience. MATERIALS AND METHODS Ten surgical guides of each type (MSG, 3DSG, and CSG) were fabricated on a control study model with missing right and left central incisors. Sixty implants were placed in 30 study models by two dentists (one inexperienced and one experienced) using three different types of surgical guides. Horizontal deviations at shoulder and at apex, vertical, and angular deviations were measured after superimposing the planned and placed implant positions in the software. Kruskal-Wallis and Mann-Whitney U tests were used to compare the accuracy of three types of surgical guides in each dentist group and the accuracy of each surgical guide between two dentists (α = .05). RESULTS There were no significant differences in any deviations between CSG and 3DSG, apart from angular deviation, for both dentists' groups. Moreover, both CSG and 3DSG showed no significant differences in accuracy between the two dentists (P > .05). In contrast, MSG demonstrated significant differences from CSG and 3DSG and a significant difference in accuracy between the two dentists (P < .05). CONCLUSION CSG provides superior accuracy to MSG in implant placement in the maxillary anterior region and is comparable to 3DSG at different levels of surgical experience, while offering the benefits of shorter manufacturing time and reduced patient visits.
Collapse
Affiliation(s)
- Phyo Ei Ei Htay
- Department of Prosthodontics, College of Dentistry, Kyung Hee University, Seoul, Republic of Korea
| | - Richard Leesungbok
- Department of Biomaterials and Prosthodontics, Kyung Hee University College of Dentistry, Kyung Hee University Dental Hospital at Gangdong, Seoul, Republic of Korea
| | - Suk Won Lee
- Department of Biomaterials and Prosthodontics, Kyung Hee University College of Dentistry, Kyung Hee University Dental Hospital at Gangdong, Seoul, Republic of Korea
| | - Yu-Jin Jee
- Department of Oral and Maxillofacial Surgery, Kyung Hee University College of Dentistry, Kyung Hee University Dental Hospital at Gangdong, Seoul, Republic of Korea
| | - Kyung Lhi Kang
- Department of Periodontics, Kyung Hee University College of Dentistry, Kyung Hee University Dental Hospital at Gangdong, Seoul, Republic of Korea
| | - Sung Ok Hong
- Department of Oral and Maxillofacial Surgery, Kyung Hee University College of Dentistry, Kyung Hee University Dental Hospital at Gangdong, Seoul, Republic of Korea
| |
Collapse
|
5
|
Song YW, Park JY, Jung JY, Kim JN, Hu KS, Lee JS. Does the fixture thread depth affect the accuracy of implant placement during fully guided immediate implant placement?: A human cadaver study. Clin Oral Implants Res 2023; 34:116-126. [PMID: 36458928 DOI: 10.1111/clr.14023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 10/26/2022] [Accepted: 11/16/2022] [Indexed: 12/04/2022]
Abstract
BACKGROUND The fixture thread depth reportedly influences the primary stability of dental implant, but its effect on the positional accuracy in immediate implant placement has not been reported previously. MATERIALS AND METHODS Fifty-six single-rooted, anterior and premolar teeth were extracted from six human cadavers, followed by installing either regular-threaded implants (RT group, N = 30) or deep-threaded implants (DT group, N = 26) completely relying on the surgical guide. Optical impressions taken after osteotomy and fixture installation were superimposed with the preoperative virtual planning data to measure the vertical, angular, platform and apex deviations that occurred during osteotomy and installation. RESULTS While the osteotomy deviations were similar between the two groups, the angular and apex deviation of the DT group (2.67 ± 2.56°; 1.04 ± 0.49 mm, respectively) were significantly larger than those of the RT group (1.61 ± 1.04°; 0.67 ± 0.41 mm, respectively) during installation (p < .05). When the installation deviations were analysed in the anterior and premolar areas separately, the angular, platform and apex deviations of the DT group (3.05 ± 3.26°; 0.75 ± 0.32 mm; 1.08 ± 0.56 mm, respectively) were significantly larger than those of the RT group (1.56 ± 0.73°, 0.59 ± 0.28 mm; 0.62 ± 0.38 mm, respectively) in the anterior site (p < .05), whereas there was no significant intergroup difference in the premolar site. CONCLUSION In immediate-implant surgery, using an implant with a deeper thread might increase the deviations during installation, especially in the anterior area.
Collapse
Affiliation(s)
- Young Woo Song
- Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry, Seoul, South Korea.,Innovation Research and Support Center for Dental Science, Yonsei University Dental Hospital, Seoul, South Korea
| | - Jin-Young Park
- Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry, Seoul, South Korea.,Innovation Research and Support Center for Dental Science, Yonsei University Dental Hospital, Seoul, South Korea
| | - Ji-Young Jung
- Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry, Seoul, South Korea.,Innovation Research and Support Center for Dental Science, Yonsei University Dental Hospital, Seoul, South Korea
| | - Joo-Nyeon Kim
- Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry, Seoul, South Korea.,Innovation Research and Support Center for Dental Science, Yonsei University Dental Hospital, Seoul, South Korea
| | - Kyung-Seok Hu
- Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry, Seoul, South Korea
| | - Jung-Seok Lee
- Department of Periodontology, Research Institute for Periodontal Regeneration, Yonsei University College of Dentistry, Seoul, South Korea.,Innovation Research and Support Center for Dental Science, Yonsei University Dental Hospital, Seoul, South Korea
| |
Collapse
|