Izuagbe S, Roy J, Chatila A, Hoang LQ, Ea V, Vaish B, Co CM, Ly A, Wu H, Tang L. A 3D in vitro model for assessing the influence of intraocular lens: Posterior lens capsule interactions on lens epithelial cell responses. Exp Eye Res 2024; 244:109940. [PMID: 38782178 DOI: 10.1016/j.exer.2024.109940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 05/19/2024] [Accepted: 05/21/2024] [Indexed: 05/25/2024]
Abstract
Posterior Capsule Opacification (PCO), the most frequent complication of cataract surgery, is caused by the infiltration and proliferation of lens epithelial cells (LECs) at the interface between the intraocular lens (IOL) and posterior lens capsule (PLC). According to the "no space, no cells, no PCO" theory, high affinity (or adhesion force) between the IOL and PLC would decrease the IOL: PLC interface space, hinder LEC migration, and thus reduce PCO formation. To test this hypothesis, an in vitro hemisphere-shaped simulated PLC (sPLC) was made to mimic the human IOL: PLC physical interactions and to assess their influence on LEC responses. Three commercially available IOLs with different affinities/adhesion forces toward the sPLC, including Acrylic foldable IOL, Silicone IOL, and PMMA IOL, were used in this investigation. Using the system, the physical interactions between IOLs and sPLC were quantified by measuring the adhesion force and interface space using an adhesion force apparatus and Optical Coherence Tomography, respectively. Our data shows that high adhesion force and tight binding between IOL and sPLC contribute to a small interface space (or "no space"). By introducing LECs into the in vitro system, we found that, with small interface space, among all IOLs, acrylic foldable IOLs permitted the least extent of LEC infiltration, proliferation, and differentiation (or "no cells"). Further statistical analyses using clinical data revealed that weak LEC responses are associated with low clinical PCO incidence rates (or "no PCO"). The findings support that the in vitro system could simulate IOL: PLC interplays and predict IOLs' PCO potential in support of the "no space, no cells, no PCO" hypothesis.
Collapse
Affiliation(s)
- Samira Izuagbe
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Joyita Roy
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Amjad Chatila
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Le Quynh Hoang
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Vicki Ea
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Bhavya Vaish
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Cynthia M Co
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Aaron Ly
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Hongli Wu
- Department of Pharmaceutical Sciences, College of Pharmacy, North Texas Eye Research Institute, University of North Texas Health Science Center, Fort Worth, TX, 76107, USA
| | - Liping Tang
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA.
| |
Collapse
|
2
|
Intra- and inter-operator concordance of the resonance frequency analysis. A cross-sectional and prospective clinical study. Clin Oral Investig 2022; 26:6521-6530. [PMID: 35804172 DOI: 10.1007/s00784-022-04601-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Accepted: 06/20/2022] [Indexed: 11/03/2022]
Abstract
OBJECTIVE Resonance frequency analysis (RFA) provides an evaluation of implant stability over time. This analysis is a non-invasive, precise, and objective method. Several studies compare the RFA system with other devices. However, few investigations analyze repeatability and reproducibility between different operators. The aim of this study was to evaluate the intra- and inter-operator concordance of the Osstell® ISQ. MATERIAL AND METHODS RFA measurements were performed with Osstell® ISQ in a total of 37 implants placed in 21 patients. At the time of implant placement, 6 measurements per implant were taken by three different experienced operators. Three measurements were carried out consecutively and three by removing and placing the SmartPeg-Osstell® to assess intra-operator and inter-operator agreement. RESULTS Intra-operator concordance according to the intraclass correlation coefficient (ICC) showed high concordance. The ICC values were higher than 0.9 (p < 0.0001) for consecutive measures and alternative measures, being almost perfect of Landis & Koch classification. For inter-operator concordance The ICC was 0.709 (p < 0.0001) and 0.670 (p < 0.0001) for consecutive and alternative measures, respectively, both estimates being in the substantial category. In torque and ISQ values, no statistically significant differences were observed when operators and measurements were compared. CONCLUSIONS Osstell® ISQ system was stable both in intra-operator and inter-operator measurements. This device has excellent repeatability and reproducibility, demonstrating reliability to measure the stability of dental implants. CLINICAL RELEVANCE Resonance frequency analysis (RFA) is a non-invasive, objective, and reliable diagnostic method to determine the ideal moment to load the implant, as well as to predict possible failures.
Collapse
|
3
|
Evaluation of Implant Stability and Trephination Depth for Implant Removal-An In Vitro Study. MATERIALS 2022; 15:ma15124200. [PMID: 35744258 PMCID: PMC9227053 DOI: 10.3390/ma15124200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Revised: 05/25/2022] [Accepted: 06/08/2022] [Indexed: 02/04/2023]
Abstract
Malpositioned and broken implants are usually fully osseointegrated; hence, their removal, especially from the lower arch, can be very challenging. Implant removal techniques include reverse torque and trephination. Trephination is an invasive technique that can jeopardize vital structures, cause mandibular fatigue fractures, or lead to osteomyelitis. In this study, we aimed to assess the relationship between trephination depth and implant stability by recording implant stability quotient (ISQ) readings at varying trephination depths in vitro. Materials and methods: Forty-eight implants were inserted into dense synthetic polyurethane foam blocks as artificial bone. Primary implant stability was measured with a Penguin resonance frequency analysis (RFA) device. Implants of two designs with a diameter of 3.75 mm and a length of 13 or 8 mm were inserted. Twenty-four internal hexagon (IH) (Seven®) and twenty-four conical connection (CC) implants (C1®; MIS® Implants, Ltd., Misgav, Israel) were used. The primary implant stability was measured with the RFA device. Trephination was performed, and implant stability was recorded at depths of 0, 3, and 6 mm for the 8 mm implants and 0, 3, 6, 8, 10, and 11.5 mm for the 13 mm implants. Results: Linear regression revealed a significant relation between the trephination depth and the ISQ (F (1, 213) = 1113.192, p < 0.001, adjusted r2 = 0.839). The trephination depth significantly predicted the ISQ (β = −5.337, p < 0.001), and the ISQ decreased by −5.33 as the trephination depth increased by 1 mm. Conclusion: Implant stability reduction as measured using an RFA device during trephination may be a valuable guide to achieving safe reverse torque for implant removal. Further studies are needed to evaluate these data in clinical settings.
Collapse
|
4
|
Raz P, Meir H, Levartovsky S, Sebaoun A, Beitlitum I. Primary Implant Stability Analysis of Different Dental Implant Connections and Designs-An In Vitro Comparative Study. MATERIALS (BASEL, SWITZERLAND) 2022; 15:3072. [PMID: 35591407 PMCID: PMC9104754 DOI: 10.3390/ma15093072] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Revised: 03/23/2022] [Accepted: 04/21/2022] [Indexed: 02/05/2023]
Abstract
Primary implant stability can be evaluated at the time of placement by measuring the insertion torque (IT). However, another method to monitor implant stability over time is resonance frequency analysis (RFA). Our aim was to examine the effect of bone type, implant design, and implant length on implant primary stability as measured by IT and two RFA devices (Osstell and Penguin) in an in vitro model. Ninety-six implants were inserted by a surgical motor in an artificial bone material, resembling soft and dense bone. Two different implant designs-conical connection (CC) and internal hex (IH), with lengths of 13 and 8 mm, were compared. The results indicate that the primary stability as measured by RFA and IT is significantly increased by the quality of bone (dense bone), and implant length and design, where the influence of dense bone is similar to that of CC design. Both the Osstell and Penguin devices recorded higher primary implant stability for long implants in dense bone, favoring the CC over the IH implant design. The CC implant design may compensate for the low stability expected in soft bone, and dense bone may compensate for short implant length if required by the anatomical bone conditions.
Collapse
Affiliation(s)
- Perry Raz
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel; (H.M.); (A.S.); (I.B.)
| | - Haya Meir
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel; (H.M.); (A.S.); (I.B.)
| | - Shifra Levartovsky
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel;
| | - Alon Sebaoun
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel; (H.M.); (A.S.); (I.B.)
| | - Ilan Beitlitum
- Department of Periodontology and Dental Implants, The Maurice and Gabriela Goldschleger School of Dental Medicine, The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6139001, Israel; (H.M.); (A.S.); (I.B.)
| |
Collapse
|