1
|
Ellakany P, Aly NM, Alghamdi MM, Alameer ST, Alshehri T, Akhtar S, Madi M. Effect of Different Scaling Methods on the Surface Topography of Different CAD/CAM Ceramic Compositions. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2974. [PMID: 37109810 PMCID: PMC10143924 DOI: 10.3390/ma16082974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/16/2023] [Revised: 03/25/2023] [Accepted: 04/03/2023] [Indexed: 06/19/2023]
Abstract
This study evaluated the effect of ultrasonic and manual scaling using different scaler materials on the surface topography of computer-aided designing and computer-aided manufacturing (CAD/CAM) ceramic compositions. After scaling with manual and ultrasonic scalers, the surface properties of four classes of CAD/CAM ceramic discs: lithium disilicate (IPE), leucite-reinforced (IPS), advanced lithium disilicate (CT), and zirconia-reinforced lithium silicate (CD) of 1.5 mm thickness were evaluated. Surface roughness was measured before and after treatment, and scanning electron microscopy was used to evaluate the surface topography following the performed scaling procedures. Two-way ANOVA was conducted to assess the association of the ceramic material and scaling method with the surface roughness. There was a significant difference in the surface roughness between the ceramic materials subjected to different scaling methods (p < 0.001). Post-hoc analyses revealed significant differences between all groups except for IPE and IPS where no significant differences were detected between them. CD showed the highest surface roughness values, while CT showed the lowest surface roughness values for the control specimens and after exposure to different scaling methods. Moreover, the specimens subjected to ultrasonic scaling displayed the highest roughness values, while the least surface roughness was noted with the plastic scaling method.
Collapse
Affiliation(s)
- Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Nourhan M. Aly
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria 21527, Egypt
| | - Maram M. Alghamdi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Shahad T. Alameer
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Turki Alshehri
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Sultan Akhtar
- Department of Biophysics, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam 31441, Saudi Arabia
| | - Marwa Madi
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| |
Collapse
|
2
|
Grande F, Pozzan MC, Marconato R, Mollica F, Catapano S. Evaluation of Load Distribution in a Mandibular Model with Four Implants Depending on the Number of Prosthetic Screws Used for OT-Bridge System: A Finite Element Analysis (FEA). MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15227963. [PMID: 36431449 PMCID: PMC9699052 DOI: 10.3390/ma15227963] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 11/09/2022] [Accepted: 11/09/2022] [Indexed: 05/28/2023]
Abstract
In full-arch implant rehabilitations, when the anterior screw abutment channel compromises the aesthetic of the patient, the OT-Bridge system used with its Seeger rings may provide the necessary retention of the prosthesis. However, no studies have evaluated the forces generated at the Seeger level during loading. This Finite Element Analysis aims to investigate the mechanical behavior of Seeger rings in a mandibular model with four implants and an OT-Bridge system, used without one or two anterior prosthetic screws. A 400 N unilateral load was virtually applied on a 7 mm distal cantilever. Two different variables were considered: the constraint conditions using two or three screws instead of four and the three different framework materials (fiberglass reinforced resin, cobalt-chrome, TiAl6V4). The FEA analysis exhibited tensile and compressive forces on the Seeger closest to the loading point. With the resin framework, a tension force on abutment 3.3 generates a displacement from 5 to 10 times greater than that respectively expressed in metal framework materials. In a full-arch rehabilitation with four implants, the case with three prosthetic screws seems to be a safer and more predictable configuration instead of two. Considering the stress value exhibited and the mechanical properties of the Seeger, the presence of only two prosthetic screws could lead to permanent deformation of the Seeger in the screwless abutment closest to the loading point.
Collapse
Affiliation(s)
- Francesco Grande
- Department of Prosthodontics, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Via Nizza, 230, 10126 Torino, Italy
| | - Mario Cesare Pozzan
- Department of Prosthodontics, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy
| | - Raul Marconato
- Department of Prosthodontics, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy
| | - Francesco Mollica
- Department of Engineering, University of Ferrara, 44121 Ferrara, Italy
| | - Santo Catapano
- Department of Prosthodontics, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy
| |
Collapse
|
3
|
Chuchulska B, Hristov I, Dochev B, Raychev R. Changes in the Surface Texture of Thermoplastic (Monomer-Free) Dental Materials Due to Some Minor Alterations in the Laboratory Protocol-Preliminary Study. MATERIALS (BASEL, SWITZERLAND) 2022; 15:6633. [PMID: 36233975 PMCID: PMC9570521 DOI: 10.3390/ma15196633] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Revised: 09/16/2022] [Accepted: 09/20/2022] [Indexed: 06/16/2023]
Abstract
Contemporary thermoplastic monomer-free prosthetic materials are widely used nowadays, and there are a great variety available on the market. These materials are of interest in terms of the improvement of the quality features of the removable dentures. The aim of this study is to establish how minimal changes in the laboratory protocol of polyamide prosthetic base materials influence the surface texture. Two polyamide materials intended for the fabrication of removable dentures bases were used-Perflex Biosens (BS) and VertexTM ThermoSens (TS). A total number of 20 coin-shaped samples were prepared. They were injected under two different modes-regular, as provided by the manufacturer, and modified, proposed by the authors of this study. Scanning electronic microscopy (SEM) under four magnifications-×1000, ×3000, ×5000, and ×10,000-was conducted. With minimal alterations to the melting temperature (5 °C) and the pressure (0.5 Bar), in Biosens, no changes in terms of surface improvement were found, whereas in ThermoSens, the surface roughness of the material significantly changed in terms of roughness reduction. By modifying the technological mode during injection molding, a smoother surface was achieved in one of the studied materials.
Collapse
Affiliation(s)
- Bozhana Chuchulska
- Department of Prosthetic Dental Medicine, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Ilian Hristov
- Department of Prosthetic Dental Medicine, Faculty of Dental Medicine, Medical University of Plovdiv, 4000 Plovdiv, Bulgaria
| | - Boyan Dochev
- Department of Mechanics, Faculty of Mechanical Engineering, Technical University of Sofia, Branch Plovdiv, 4000 Plovdiv, Bulgaria
| | - Raycho Raychev
- Department of Mechanics, Faculty of Mechanical Engineering, Technical University of Sofia, Branch Plovdiv, 4000 Plovdiv, Bulgaria
| |
Collapse
|
4
|
Alovisi M, Carossa M, Mandras N, Roana J, Costalonga M, Cavallo L, Pira E, Putzu MG, Bosio D, Roato I, Mussano F, Scotti N. Disinfection and Biocompatibility of Titanium Surfaces Treated with Glycine Powder Airflow and Triple Antibiotic Mixture: An In Vitro Study. MATERIALS 2022; 15:ma15144850. [PMID: 35888317 PMCID: PMC9319194 DOI: 10.3390/ma15144850] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 06/30/2022] [Accepted: 07/08/2022] [Indexed: 01/16/2023]
Abstract
The aim of this in vitro study was to compare three disinfection protocols of biofilm-coated machined (MAC) and acid etched (SLA) commercial pure Grade 4 Titanium disks. Samples were infected with a vial of polymicrobial biofilm to simulate peri-implantitis in vitro. Seventeen MAC and twenty SLA titanium disks were randomly assigned to: (1) glycine powder air-flow (GYPAP) for 1 min; (2) a local delivered triple paste antibiotic composed by a gel mixture with ciprofloxacin, metronidazole, and clarithromycin (3MIX) for 1 h; and (3) a combination of both (GYPAP + 3MIX). Biocompatibility of the titanium disks after each treatment protocol was assessed by measurement of adhesion and growth of adipose-derived mesenchymal stem cells (ASCs) after 24 and 72 h. A confocal laser scanning microscope (CLSM) assessed the antibacterial effect of each treatment. Data of the antibacterial efficacy and cell viability were presented as mean with standard deviation and calculated by one-way ANOVA with multiple comparisons via Bonferroni tests. Results were considered significant with p < 0.05. The higher cell viability was achieved by the 3MIX and GYPAP combination on the SLA surfaces after 72 h. CLSM analysis showed a mean ratio of dead bacteria statistically higher in the 3MIX + GYPAP group compared with the GYPAP and 3MIX subgroups (p < 0.05). In conclusion, data showed that the combination of GYPAP and 3MIX could be preferred to the other protocols, especially in presence of SLA titanium surface.
Collapse
Affiliation(s)
- Mario Alovisi
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (M.A.); (I.R.); (F.M.); (N.S.)
| | - Massimo Carossa
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (M.A.); (I.R.); (F.M.); (N.S.)
- Correspondence:
| | - Narcisa Mandras
- Department of Public Health and Pediatrics, University of Turin, 10126 Turin, Italy; (N.M.); (J.R.); (L.C.); (E.P.)
| | - Janira Roana
- Department of Public Health and Pediatrics, University of Turin, 10126 Turin, Italy; (N.M.); (J.R.); (L.C.); (E.P.)
| | - Massimo Costalonga
- Diagnostic and Biological Sciences, University of Minnesota, Minneapolis, MN 55455, USA;
| | - Lorenza Cavallo
- Department of Public Health and Pediatrics, University of Turin, 10126 Turin, Italy; (N.M.); (J.R.); (L.C.); (E.P.)
| | - Enrico Pira
- Department of Public Health and Pediatrics, University of Turin, 10126 Turin, Italy; (N.M.); (J.R.); (L.C.); (E.P.)
| | - Maria Grazia Putzu
- Unit of Occupational Medicine and Hospital Occupational Unit, A.O.U Città della Salute e della Scienza di Torino, 10126 Turin, Italy; (M.G.P.); (D.B.)
| | - Davide Bosio
- Unit of Occupational Medicine and Hospital Occupational Unit, A.O.U Città della Salute e della Scienza di Torino, 10126 Turin, Italy; (M.G.P.); (D.B.)
| | - Ilaria Roato
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (M.A.); (I.R.); (F.M.); (N.S.)
| | - Federico Mussano
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (M.A.); (I.R.); (F.M.); (N.S.)
| | - Nicola Scotti
- Department of Surgical Sciences, CIR Dental School, University of Turin, Via Nizza 230, 10126 Turin, Italy; (M.A.); (I.R.); (F.M.); (N.S.)
| |
Collapse
|
5
|
Full Digital Workflow for Prosthetic Full-Arch Immediate Loading Rehabilitation Using OT-Bridge System: A Case Report. PROSTHESIS 2022. [DOI: 10.3390/prosthesis4020021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Nowadays, digital technologies have brought very important advancements in clinical prosthetic dentistry. However, a full digital workflow is still considered to be challenging in the management of full-arch implant cases with immediate prosthetic loading. The aim of this case report is to show a full-digital workflow for the fabrication of an implant-prosthetic fixed provisional prosthesis for immediate loading on seven implants in the upper maxilla. The static guided implant surgery and the OT Bridge prosthetic system were used to rehabilitate the patient. In this way, the combination of a well-known surgical technique with a peculiar prosthetic system that allows for a certain degree of tolerance resulted in it being useful for full-arch immediate loading. Future research and studies are necessary to prove the reliability of this full-digital protocol.
Collapse
|