1
|
Kandaswamy E, Harsha M, Joshi VM. Titanium corrosion products from dental implants and their effect on cells and cytokine release: A review. J Trace Elem Med Biol 2024; 84:127464. [PMID: 38703537 DOI: 10.1016/j.jtemb.2024.127464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2024] [Revised: 04/17/2024] [Accepted: 04/22/2024] [Indexed: 05/06/2024]
Abstract
INTRODUCTION Titanium is considered to be an inert material owing to the ability of the material to form a passive titanium oxide layer. However, once the titanium oxide layer is lost, it can lead to exposure of the underlying titanium substructure and can undergo corrosion. SUMMARY The article explores the role of titanium ions and particles from dental implants on cells, cytokine release, and on the systemic redistribution of these particles as well as theories proposed to elucidate the effects of these particles on peri-implant inflammation based on evidence from in-vitro, human, and animal studies. Titanium particles and ions have a pro-inflammatory and cytotoxic effect on cells and promote the release of pro-inflammatory mediators like cytokines. Three theories to explain etiopathogenesis have been proposed, one based on microbial dysbiosis, the second based on titanium particles and ions and the third based on a synergistic effect between microbiome and titanium particles on the host. CONCLUSION There is clear evidence from in-vitro and limited human and animal studies that titanium particles released from dental implants have a detrimental effect on cells directly and through the release of pro-inflammatory cytokines. Future clinical and translational studies are required to clarify the role of titanium particles and ions in peri-implant inflammation and the etiopathogenesis of peri-implantitis.
Collapse
Affiliation(s)
- Eswar Kandaswamy
- Department of Periodontics, LSUHSC, School of Dentistry, 100 Florida Avenue, New Orleans, LA 70119, USA
| | - M Harsha
- Department of Oral Pathology & Microbiology, Yogita Dental College & Hospital, Naringi Riverside, At Post Tal Dist. SH104, Khed, Maharashtra 415709, India
| | - Vinayak M Joshi
- Department of Periodontics, LSUHSC, School of Dentistry, 100 Florida Avenue, New Orleans, LA 70119, USA.
| |
Collapse
|
2
|
Jalaluddin M, Subramanian D, Mathew J, Mailankote S, Almuraikhi T, Daghriri A. Evaluation of the Impact of Different Surface Treatments on Implant Surface: An In Vitro Study. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES 2024; 16:S1132-S1135. [PMID: 38882791 PMCID: PMC11174287 DOI: 10.4103/jpbs.jpbs_1092_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 11/13/2023] [Accepted: 11/14/2023] [Indexed: 06/18/2024] Open
Abstract
Aim The current study was conducted to assess the effects of various surface treatments on the implant surface. Materials and Methods A total of 45 dental implants measuring 16 mm in length and 5 mm in diameter were used, along with the appropriate abutments. Depending on the surface treatment used, the samples were randomly split into three groups, with 15 implants in each group: Group 1: Control, Group 2: UV light-treated, Group 3: Sandblasted and acid-etched (SLA)-treated. After surface treatment, a scanning electron microscope (SEM) was used to assess the test samples' surface properties. All sample images were captured using a 3000× magnification. After all three groups' surfaces were treated, the surface roughness was measured using a digital optical profilometer with a stylus speed of 0.5 mm/s that was connected to computer software. Results The maximum surface roughness was found in the group treated with SLA (0.714 ± 0.12), followed by the group treated with UV light (0.692 ± 0.09) and the control group (0.516 ± 0.12). There was a significant difference found between different surface treatment methods. Conclusion The present study concluded that the group that received the SLA treatment had the highest surface roughness when compared to the UV light and control groups.
Collapse
Affiliation(s)
- Mohammad Jalaluddin
- Department of Periodontics and Oral Implantology, Kalinga Institute of Dental Sciences, KIIT Deemed to be University, Bhubaneswar, Odisha, India
| | - Deepa Subramanian
- Department of Prosthodontics, RVS Dental College and Hospital, Sulur, Coimbatore, Tamil Nadu, India
| | - Joel Mathew
- Department of Pediatric and Preventive Dentistry, Mar Baselios Dental College, Kothamangalam, Ernakulam, Kerala, India
| | - Shilpa Mailankote
- Department of Public Health Dentistry, AB Shetty Memorial Institute of Dental Sciences (ABSMIDS), Nitte (Deemed to be University), Mangalore, Karnataka, India
| | - Turki Almuraikhi
- Department of Prosthodontics, College of Dentistry, Majmaah University, AL-Majmaah, Saudi Arabia
| | - Alhussain Daghriri
- Department of Prosthodontics, College of Dentistry, Majmaah University, AL-Majmaah, Saudi Arabia
| |
Collapse
|
3
|
Calazans Neto JV, Ferreira I, Ramos AP, Bolfarini C, Batalha RL, Dos Reis AC, Valente MLDC. Comparative analysis of the physical, chemical, and microbiological properties of Ti-6Al-4V disks produced by different methods and subjected to surface treatments. J Prosthet Dent 2024; 131:742.e1-742.e8. [PMID: 38383281 DOI: 10.1016/j.prosdent.2024.01.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 01/16/2024] [Accepted: 01/18/2024] [Indexed: 02/23/2024]
Abstract
STATEMENT OF PROBLEM To improve the osseointegration of dental implants and reduce microbiological growth, different micro- and nanoscale surface topographies can be used. PURPOSE The purpose of this in vitro study was to evaluate the influence of Ti-6Al-4V with 4 surfaces, machined (DU), machined+hydroxyapatite (DUHAp), machined+acid-alkali treatment (DUAA), and additive manufacturing (DMA), on the physical, chemical, and microbiological properties. MATERIAL AND METHODS The topography of Ti-6Al-4V disks with the 4 surfaces was evaluated by scanning electron microscopy (SEM), the chemical composition by energy dispersive X-ray spectroscopy (EDS), and the crystalline structure by X-ray diffraction (XRD). Physical and chemical properties were analyzed by using wettability and surface free energy, roughness, and microbial adhesion against Staphylococcus aureus by colony forming units (CFU). One-way ANOVA analysis of variance and the Tukey multiple comparisons test were applied to evaluate the data, except CFU, which was submitted to the Kruskal-Wallis nonparametric test (α=.05). RESULTS DU photomicrographs showed a topography characteristic of a polished machined surface, DUHAp and DUAA exhibited patterns corresponding to the surface modifications performed, and in DMA the presence of partially fused spherical particles was observed. The EDS identified chemical elements inherent in the Ti-6Al-4V, and the DUHAp and DUAA disks also had the ions from the treatments applied. XRD patterns revealed similarities between DU and DMA, as well as characteristic peaks of hydroxyapatite (HA) in the DUHAp disk and the DUAA. Compared with DU and DMA the DUHAp and DUAA groups showed hydrophilic behavior with smaller contact angles and higher surface free energy (P<.05). DMA showed a higher mean value of roughness, different from the others (P<.05), and a higher CFU for S. aureus (P=.006). CONCLUSIONS DUHAp and DUAA showed similar behaviors regarding wettability, surface free energy, and bacterial adhesion. Among the untreated groups, DMA exhibited higher roughness, bacterial adhesion, and lower wettability and surface free energy.
Collapse
Affiliation(s)
- João Vicente Calazans Neto
- Master's student, Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, University of São Paulo (USP), Ribeirão Preto, Brazil
| | - Izabela Ferreira
- Master's student, Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, University of São Paulo (USP), Ribeirão Preto, Brazil
| | - Ana Paula Ramos
- Professor, Department of Chemistry, Faculty of Philosophy, Sciences and Letters of Ribeirão Preto, University of São Paulo, (USP), Ribeirão Preto, Brazil
| | - Claudemiro Bolfarini
- Professor, Professor, Federal University of São Carlos (UFSCar), São Carlos, Brazil
| | - Rodolfo Lisboa Batalha
- Researcher, Materials and Technologies, Department of Research, Development and Innovation, Institute of Welding and Quality (ISQ), Porto Salvo, Oeiras, Portugal
| | - Andréa Cândido Dos Reis
- Professor, Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, University of São Paulo (USP), Ribeirão Preto, Brazil
| | - Mariana Lima da Costa Valente
- Professor, Department of Dental Materials and Prosthodontics, Ribeirão Preto Dental School, University of São Paulo (USP), Ribeirão Preto, Brazil.
| |
Collapse
|
4
|
Vilarrasa J, Àlvarez G, Soler-Ollé A, Gil J, Nart J, Blanc V. Bacterial Adhesion of TESPSA and Citric Acid on Different Titanium Surfaces Substrate Roughness: An In Vitro Study with a Multispecies Oral Biofilm Model. MATERIALS (BASEL, SWITZERLAND) 2023; 16:4592. [PMID: 37444905 DOI: 10.3390/ma16134592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Revised: 06/11/2023] [Accepted: 06/23/2023] [Indexed: 07/15/2023]
Abstract
This in vitro study analyzed the influence of substrate roughness on biofilm adhesion and cellular viability over triethoxysilylpropyl succinic anhydride silane (TESPSA)- and citric acid (CA)-coated surfaces at 12 and 24 h, respectively. A multispecies biofilm composed of S. oralis, A. naslundii, V. parvula, F. nucleatum, P. intermedia, P. gingivalis, P. endodontalis and F. alocis was developed over titanium discs grouped depending on their roughness (low, medium, high) and antibacterial coating (low-TESPSA, medium-TESPSA, high-TESPSA, and CA). The biofilm was quantified by means of quantitative polymerase chain reaction (PCR) and viability PCR and assessed through confocal laser scanning microscope (CLSM). Quantitative PCR revealed no significant differences in bacterial adhesion and biofilm mortality. CA was the surface with the lowest bacterial counts and highest mortality at 12 and 24 h, respectively, while high harbored the highest amount of biofilm at 24 h. By CLSM, CA presented significant amounts of dead cells compared to medium-TESPSA and high-TESPSA. A significantly greater volume of dead cells was found at 12 h in low-TESPSA compared to medium-TESPSA, while CA also presented significant amounts of dead cells compared to medium-TESPSA and high-TESPSA. With regard to the live/dead ratio, low-TESPSA presented a significantly higher ratio at 12 h compared to medium-TESPSA and high-TESPSA. Similarly, CA exhibited a significantly higher live/dead ratio compared to medium-TESPSA and high-TESPSA at 12 h. This multispecies in vitro biofilm did not evidence clear antiadhesive and bactericidal differences between surfaces, although a tendency to reduce adhesion and increase antibacterial effect was observed in the low-TESPSA and CA.
Collapse
Affiliation(s)
- Javi Vilarrasa
- Department of Periodontology, Universitat Internacional de Catalunya, 08195 Barcelona, Spain
| | - Gerard Àlvarez
- Department of Microbiology, DENTAID Research Center, 08290 Cerdanyola del Vallès, Spain
| | - Agnès Soler-Ollé
- Department of Microbiology, DENTAID Research Center, 08290 Cerdanyola del Vallès, Spain
| | - Javier Gil
- Bioengineering Institute of Technology, Universitat Internacional de Catalunya, 08195 Sant Cugat del Vallés, Spain
| | - José Nart
- Department of Periodontology, Universitat Internacional de Catalunya, 08195 Barcelona, Spain
| | - Vanessa Blanc
- Department of Microbiology, DENTAID Research Center, 08290 Cerdanyola del Vallès, Spain
| |
Collapse
|
5
|
Tardelli JDC, Bagnato VS, Reis ACD. Bacterial Adhesion Strength on Titanium Surfaces Quantified by Atomic Force Microscopy: A Systematic Review. Antibiotics (Basel) 2023; 12:994. [PMID: 37370313 DOI: 10.3390/antibiotics12060994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Revised: 12/04/2022] [Accepted: 12/05/2022] [Indexed: 06/29/2023] Open
Abstract
Few studies have been able to elucidate the correlation of factors determining the strength of interaction between bacterial cells and substrate at the molecular level. The aim was to answer the following question: What biophysical factors should be considered when analyzing the bacterial adhesion strength on titanium surfaces and its alloys for implants quantified by atomic force microscopy? This review followed PRISMA. The search strategy was applied in four databases. The selection process was carried out in two stages. The risk of bias was analyzed. One thousand four hundred sixty-three articles were found. After removing the duplicates, 1126 were screened by title and abstract, of which 57 were selected for full reading and 5 were included; 3 had a low risk of bias and 2 moderated risks of bias. (1) The current literature shows the preference of bacteria to adhere to surfaces of the same hydrophilicity. However, this fact was contradicted by this systematic review, which demonstrated that hydrophobic bacteria developed hydrogen bonds and adhered to hydrophilic surfaces; (2) the application of surface treatments that induce the reduction of areas favorable for bacterial adhesion interfere more in the formation of biofilm than surface roughness; and (3) bacterial colonization should be evaluated in time-dependent studies as they develop adaptation mechanisms, related to time, which are obscure in this review.
Collapse
Affiliation(s)
- Juliana Dias Corpa Tardelli
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto 14040-904, Brazil
| | - Vanderlei Salvador Bagnato
- Department of Physics and Materials Science, São Carlos Institute of Physics, University of São Paulo (USP), São Carlos 13566-970, Brazil
| | - Andréa Cândido Dos Reis
- Department of Dental Materials and Prosthesis, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto 14040-904, Brazil
| |
Collapse
|
6
|
Rodriguez-González R, Monsalve-Guil L, Jimenez-Guerra A, Velasco-Ortega E, Moreno-Muñoz J, Nuñez-Marquez E, Pérez RA, Gil J, Ortiz-Garcia I. Relevant Aspects of Titanium Topography for Osteoblastic Adhesion and Inhibition of Bacterial Colonization. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16093553. [PMID: 37176435 PMCID: PMC10180273 DOI: 10.3390/ma16093553] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2023] [Revised: 04/27/2023] [Accepted: 05/04/2023] [Indexed: 05/15/2023]
Abstract
The influence of the surface topography of dental implants has been studied to optimize titanium surfaces in order to improve osseointegration. Different techniques can be used to obtain rough titanium, however, their effect on wettability, surface energy, as well as bacterial and cell adhesion and differentiation has not been studied deeply. Two-hundred disks made of grade 4 titanium were subjected to different treatments: machined titanium (MACH), acid-attacked titanium (AE), titanium sprayed with abrasive alumina particles under pressure (GBLAST), and titanium that has been treated with GBLAST and then subjected to AE (GBLAST + AE). The roughness of the different treatments was determined by confocal microscopy, and the wettability was determined by the sessile drop technique; then, the surface energy of each treatment was calculated. Osteoblast-like cells (SaOs-2) were cultured, and alkaline phosphatase was determined using a colorimetric test. Likewise, bacterial strains S. gordonii, S. oralis, A. viscosus, and E. faecalis were cultured, and proliferation on the different surfaces was determined. It could be observed that the roughness of the GBLAST and GBLAS + AE was higher, at 1.99 and 2.13 μm of Ra, with respect to the AE and MACH samples, which were 0.35 and 0.20 μm, respectively. The abrasive treated surfaces showed lower hydrophilicity but lower surface energy. Significant differences could be seen at 21 days between SaOS-2 osteoblastic cell adhesion for the blasted ones and higher osteocalcin levels. However, no significant differences in terms of bacterial proliferation were observed between the four surfaces studied, demonstrating the insensitivity of bacteria to topography. These results may help in the search for the best topographies for osteoblast behavior and for the inhibition of bacterial colonization.
Collapse
Affiliation(s)
- Raquel Rodriguez-González
- Bioengineering Institute of Technology, Faculty of Dentistry, Universitat Internacional de Catalunya, Sant Cugat del Vallé, 08198 Barcelona, Spain
| | | | | | | | | | | | - Roman A Pérez
- Bioengineering Institute of Technology, Faculty of Dentistry, Universitat Internacional de Catalunya, Sant Cugat del Vallé, 08198 Barcelona, Spain
| | - Javier Gil
- Bioengineering Institute of Technology, Faculty of Dentistry, Universitat Internacional de Catalunya, Sant Cugat del Vallé, 08198 Barcelona, Spain
| | | |
Collapse
|
7
|
Arakelyan M, Spagnuolo G, Iaculli F, Dikopova N, Antoshin A, Timashev P, Turkina A. Minimization of Adverse Effects Associated with Dental Alloys. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7476. [PMID: 36363067 PMCID: PMC9658402 DOI: 10.3390/ma15217476] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 10/17/2022] [Accepted: 10/21/2022] [Indexed: 06/16/2023]
Abstract
Metal alloys are one of the most popular materials used in current dental practice. In the oral cavity, metal structures are exposed to various mechanical and chemical factors. Consequently, metal ions are released into the oral fluid, which may negatively affect the surrounding tissues and even internal organs. Adverse effects associated with metallic oral appliances may have various local and systemic manifestations, such as mouth burning, potentially malignant oral lesions, and local or systemic hypersensitivity. However, clear diagnostic criteria and treatment guidelines for adverse effects associated with dental alloys have not been developed yet. The present comprehensive literature review aims (1) to summarize the current information related to possible side effects of metallic oral appliances; (2) to analyze the risk factors aggravating the negative effects of dental alloys; and (3) to develop recommendations for diagnosis, management, and prevention of pathological conditions associated with metallic oral appliances.
Collapse
Affiliation(s)
- Marianna Arakelyan
- Therapeutic Dentistry Department, Institute for Dentistry, Sechenov University, 119991 Moscow, Russia
| | - Gianrico Spagnuolo
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples “Federico II”, 80138 Napoli, Italy
| | - Flavia Iaculli
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples “Federico II”, 80138 Napoli, Italy
| | - Natalya Dikopova
- Therapeutic Dentistry Department, Institute for Dentistry, Sechenov University, 119991 Moscow, Russia
| | - Artem Antoshin
- Institute for Regenerative Medicine, Sechenov University, 119991 Moscow, Russia
- World-Class Research Center “Digital Biodesign and Personalized Healthcare”, Sechenov University, 119991 Moscow, Russia
| | - Peter Timashev
- Institute for Regenerative Medicine, Sechenov University, 119991 Moscow, Russia
- World-Class Research Center “Digital Biodesign and Personalized Healthcare”, Sechenov University, 119991 Moscow, Russia
- Chemistry Department, Lomonosov Moscow State University, 119234 Moscow, Russia
| | - Anna Turkina
- Therapeutic Dentistry Department, Institute for Dentistry, Sechenov University, 119991 Moscow, Russia
| |
Collapse
|
8
|
Jornet-García A, Sanchez-Perez A, Montoya-Carralero JM, Moya-Villaescusa MJ. Electrical Potentiometry with Intraoral Applications. MATERIALS 2022; 15:ma15155100. [PMID: 35897533 PMCID: PMC9331720 DOI: 10.3390/ma15155100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/23/2022] [Revised: 07/09/2022] [Accepted: 07/21/2022] [Indexed: 02/04/2023]
Abstract
Dental implants currently in use are mainly made of titanium or titanium alloys. As these metallic elements are immersed in an electrolytic medium, galvanic currents are produced between them or with other metals present in the mouth. These bimetallic currents have three potentially harmful effects on the patient: micro-discharges, corrosion, and finally, the dispersion of metal ions or their oxides, all of which have been extensively demonstrated in vitro. In this original work, a system for measuring the potentials generated in vivo is developed. Specifically, it is an electrogalvanic measurements system coupled with a periodontal probe that allows measurement of the potentials in the peri-implant sulcus. This device was tested and verified in vitro to guarantee its applicability in vivo. As a conclusion, this system is able to detect galvanic currents in vitro and it can be considered capable of being employed in vivo, so to assess the effects they may cause on dental implants.
Collapse
|
9
|
Corrosion Behavior of Titanium Dental Implants with Implantoplasty. MATERIALS 2022; 15:ma15041563. [PMID: 35208101 PMCID: PMC8875252 DOI: 10.3390/ma15041563] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 01/30/2022] [Accepted: 02/16/2022] [Indexed: 02/01/2023]
Abstract
The procedure generally used to remove bacterial biofilm adhering to the surface of titanium on dental implants is implantoplasty. This treatment is based on the machining of the titanium surface to remove bacterial plaque. In this study, we used 60 grade 4 titanium implants and performed the implantoplasty protocol. Using X-ray diffraction, we determined the stresses accumulated in each of the as-received, machined and debris implants. The resistance to corrosion in open circuit and potentiodynamically in physiological medium has been determined, and the corrosion potentials and intensities have been determined. Tests have been carried out to determine ion release by ICP-MS at different immersion times. The results show that the corrosion resistance and the release of titanium ions into the medium are related to the accumulated energy or the degree of deformation. The titanium debris exhibit compressive residual stresses of −202 MPa, the implant treated with implantoplasty −120 MPa, and as-received −77 MPa, with their corrosion behavior resulting in corrosion rates of 0.501, 0.77, and 0.444 mm/year, respectively. Debris is the material with the worst corrosion resistance and the one that releases the most titanium ions to the physiological medium (15.3 ppb after 21 days vs. 7 ppb for as-received samples). Pitting has been observed on the surface of the debris released into the physiological environment. This behavior should be taken into account by clinicians for the good long-term behavior of implants with implantoplasty.
Collapse
|