1
|
Karger CP, Elter A, Dorsch S, Mann P, Pappas E, Oldham M. Validation of complex radiotherapy techniques using polymer gel dosimetry. Phys Med Biol 2024; 69:06TR01. [PMID: 38330494 DOI: 10.1088/1361-6560/ad278f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Accepted: 02/08/2024] [Indexed: 02/10/2024]
Abstract
Modern radiotherapy delivers highly conformal dose distributions to irregularly shaped target volumes while sparing the surrounding normal tissue. Due to the complex planning and delivery techniques, dose verification and validation of the whole treatment workflow by end-to-end tests became much more important and polymer gel dosimeters are one of the few possibilities to capture the delivered dose distribution in 3D. The basic principles and formulations of gel dosimetry and its evaluation methods are described and the available studies validating device-specific geometrical parameters as well as the dose delivery by advanced radiotherapy techniques, such as 3D-CRT/IMRT and stereotactic radiosurgery treatments, the treatment of moving targets, online-adaptive magnetic resonance-guided radiotherapy as well as proton and ion beam treatments, are reviewed. The present status and limitations as well as future challenges of polymer gel dosimetry for the validation of complex radiotherapy techniques are discussed.
Collapse
Affiliation(s)
- Christian P Karger
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - Alina Elter
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
- Department of Radiation Oncology, University Hospital Heidelberg, Im Neuenheimer Feld 400, D-69120 Heidelberg, Germany
| | - Stefan Dorsch
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - Philipp Mann
- Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, D-69120 Heidelberg, Germany
- National Center for Radiation Research in Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO), Heidelberg, Germany
| | - Evangelos Pappas
- Radiology & Radiotherapy Sector, Department of Biomedical Sciences, University of West Attica, Athens, Greece
| | - Mark Oldham
- Department of Radiation Oncology, Duke University Medical Center, Durham, NC, United States of America
| |
Collapse
|
2
|
da Silveira MA, Pavoni JF, Bruno AC, Arruda GV, Baffa O. Three-Dimensional Dosimetry by Optical-CT and Radiochromic Gel Dosimeter of a Multiple Isocenter Craniospinal Radiation Therapy Procedure. Gels 2022; 8:gels8090582. [PMID: 36135294 PMCID: PMC9498794 DOI: 10.3390/gels8090582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Revised: 09/07/2022] [Accepted: 09/07/2022] [Indexed: 11/30/2022] Open
Abstract
Craniospinal irradiation (CSI) is a complex radiation technique employed to treat patients with primitive neuroectodermal tumors such as medulloblastoma or germinative brain tumors with the risk of leptomeningeal spread. In adults, this technique poses a technically challenging planning process because of the complex shape and length of the target volume. Thus, it requires multiple fields and different isocenters to guarantee the primary-tumor dose delivery. Recently, some authors have proposed the use IMRT technique for this planning with the possibility of overlapping adjacent fields. The high-dose delivery complexity demands three-dimensional dosimetry (3DD) to verify this irradiation procedure and motivated this study. We used an optical CT and a radiochromic Fricke-xylenol-orange gel with the addition of formaldehyde (FXO-f) to evaluate the doses delivered at the field junction region of this treatment. We found 96.91% as the mean passing rate using the gamma analysis with 3%/2 mm criteria at the junction region. However, the concentration of fail points in a determined region called attention to this evaluation, indicating the advantages of employing a 3DD technique in complex dose-distribution verifications.
Collapse
Affiliation(s)
| | | | - Alexandre Colello Bruno
- Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto–USP, Ribeirão Preto 14015-010, Brazil
| | - Gustavo Viani Arruda
- Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto–USP, Ribeirão Preto 14015-010, Brazil
| | - Oswaldo Baffa
- Departamento de Física, FFCLRP—Universidade de São Paulo, Ribeirão Preto 14040-901, Brazil
| |
Collapse
|