1
|
Bai X, Chen Y, Zhou T, Pow EHN, Tsoi JKH. The chemical and optical stability evaluation of injectable restorative materials under wet challenge. J Dent 2024; 146:105031. [PMID: 38710315 DOI: 10.1016/j.jdent.2024.105031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 04/08/2024] [Accepted: 04/27/2024] [Indexed: 05/08/2024] Open
Abstract
OBJECTIVES To investigate and compare the chemical and optical stability of four restorative composite materials: two injectable resins, one flowable resin and one compomer. METHODS Two injectable nano-filled composite resins: G-aenial Universal (GU) and Beautifil Injectable XSL (BI), a flowable composite resin: Filtek Supreme Flowable (FS) and a compomer: Dyract Flow (DF), in A2 shade were tested and compared. Water sorption and solubility were conducted according to ISO4049:2019 standard; ICP-OES and F-ion selective electrode were used to test the elemental release; Degree of conversion (DC) was obtained by using FTIR; water contact angle was obtained by static sessile drop method, and a spectrophotometer was used for optical properties (ΔE⁎, ΔL⁎ and TP). SPSS 28.0 was used for statistical analysis and the significant level was pre-set as α = 0.05. RESULTS GU performed the best in water sorption and solubility, FS had the lowest elemental release, the best colour stability, and the highest DCIM and DC24-h. DF, the compomer had the lowest, and GU and BI, the injectable composites had the largest water contact angle, respectively. Correlations were found between water sorption and water solubility. CONCLUSIONS The four composite restorative materials showed different chemical and optical behaviours. Overall, composite resins performed better than compomer, while additional laboratory and in vivo tests are necessary to obtain a more comprehensive comparison between injectable and flowable composite resins. Wsp and Wsl are influenced by many common factors, and the values are highly positively related. CLINICAL SIGNIFICANCE A comprehensive understanding of materials is crucial before selecting materials for clinical practice. Composite resins rather than compomers are recommended because of their exceptional properties, which make them eligible for a wide range of clinical applications and an elongated lifespan.
Collapse
Affiliation(s)
- Xuedong Bai
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Yanning Chen
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Tianyu Zhou
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Edmond Ho Nang Pow
- Prosthodontics, Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - James Kit Hon Tsoi
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China.
| |
Collapse
|
2
|
Trinca RB, Vela BF, Dos Santos Vilela H, Braga RR. Ion release mechanisms in composites containing CaP particles and hydrophilic monomers. Dent Mater 2024; 40:1047-1055. [PMID: 38772841 DOI: 10.1016/j.dental.2024.05.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 05/03/2024] [Accepted: 05/03/2024] [Indexed: 05/23/2024]
Abstract
OBJECTIVE To investigate the effect of hydrophilic/permeable polymer matrices on water sorption/solubility (WS/SL), Ca2+ release, mechanical properties and hydrolytic degradation of composites containing dicalcium phosphate dihydrate (DCPD) particles. METHODS Six composites were tested, all with 10 vol% of glass particles and either 30 vol% or 40 vol% DCPD. Composites containing 1BisGMA:1TEGDMA in mols (at both inorganic levels) were considered controls. Four materials were formulated where 0.25 or 0.5 of the BisGMA/TEGDMA was replaced by pyromellitic dianhydride glycerol dimethacrylate (PMGDM)/ polyethylene glycol dimethacrylate (PEGDMA). Composites were tested for degree of conversion (FTIR spectroscopy), WS/SL (ISO 4049) and Ca2+ release (inductively coupled plasma optical emission spectroscopy). Fracture toughness (FT) and biaxial flexural strength/modulus (BFS/FM) were determined after 24 h and 60 days in water. The contributions of diffusional and relaxational mechanisms to Ca2+ release kinetics were analyzed using the semi-empirical Salim-Peppas model. Data were analysed by ANOVA/Tukey test (alpha: 0.05). RESULTS WS/SL was higher for composites containing PMGDM/PEGDMA compared to the controls (p < 0.001). Only at 40% DCPD the 0.5 PMGDM/PEGDMA composite showed statistically higher Ca2+ release than the control. Relaxation diffusion was the main release mechanism. Initial FT was not negatively affected by matrix composition. BFS (both DCPD fractions) and FM (30% DCPD) were lower for composites with hydrophilic/permeable networks (p < 0.01). After 60 days in water, composites with PMGDM/PEGDMA presented significant reductions in FT, while all composites had reductions in BFS/FM. SIGNIFICANCE Increasing matrix hydrophilicity/permeability significantly increased Ca2+ release only at a high DCPD fraction.
Collapse
Affiliation(s)
- Rafael Bergamo Trinca
- University of São Paulo School of Dentistry, Department of Biomaterials and Oral Biology, Av. Prof. Lineu Prestes, 2227, São Paulo, SP 05508-000, Brazil
| | - Beatriz Fonseca Vela
- University of São Paulo School of Dentistry, Department of Biomaterials and Oral Biology, Av. Prof. Lineu Prestes, 2227, São Paulo, SP 05508-000, Brazil
| | - Handially Dos Santos Vilela
- University of São Paulo School of Dentistry, Department of Biomaterials and Oral Biology, Av. Prof. Lineu Prestes, 2227, São Paulo, SP 05508-000, Brazil
| | - Roberto Ruggiero Braga
- University of São Paulo School of Dentistry, Department of Biomaterials and Oral Biology, Av. Prof. Lineu Prestes, 2227, São Paulo, SP 05508-000, Brazil.
| |
Collapse
|
3
|
Chen Y, Bai X, Xu M, Zhou T, Loh YM, Wang C, Pow EHN, Tsoi JKH. The mechanical, wear, antibacterial properties and biocompatibility of injectable restorative materials under wet challenge. J Dent 2024; 146:105025. [PMID: 38697507 DOI: 10.1016/j.jdent.2024.105025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 04/08/2024] [Accepted: 04/24/2024] [Indexed: 05/05/2024] Open
Abstract
OBJECTIVES To evaluate the mechanical, wear, antibacterial properties, and biocompatibility of injectable composite materials. METHODS Two injectable composite resins (GU and BI), one flowable composite resin (FS), and one flowable compomer (DF), in A2 shade, were tested. Mechanical properties were tested via three-point bending test immediately after preparation and after 1-day, 7-day, 14-day, and 30-day water storage. Under water-PMMA slurry immersion, specimens were subjected to a 3-body wear test (10,000 cycles) against stainless steel balls, while the roughness, wear depth, and volume loss were recorded. After 1-day and 3-day MC3T3-E1 cell culture, cell viability was evaluated with CCK-8 test kits, while the cell morphology was observed under CLSM and SEM. Antibacterial properties on S. mutans were assessed via CFU counting, CLSM, and SEM observation. SPSS 26.0 was used for statistical analysis (α = 0.05). RESULTS The mechanical properties were material-dependent and sensitive to water storage. Flexural strength ranked GU > FS > BI > DF at all testing levels. Three nanocomposites had better wear properties than DF. No significant difference on 1-day cell viability was found, but DF showed significantly lower cell proliferation than nanocomposites on 3-day assessment. GU and FS had more favourable cell adhesion and morphology. CFU counting revealed no significant difference, while FS presented a slightly thicker biofilm and BI showed relatively lower bacteria density. CONCLUSIONS Injectable nanocomposites outperformed the compomer regarding mechanical properties, wear resistance, and biocompatibility. The tested materials presented comparable antibacterial behaviours. Flowable resin-based composites' performances are affected by multiple factors, and their compositions can be attributed. CLINICAL SIGNIFICANCE A profound understanding of the mechanical, wear, and biological properties of the restorative material is imperative for the clinical success of dental restorations. The current study demonstrated superior properties of highly filled injectable composite resins, which imply their wider indications and better long-term clinical performances.
Collapse
Affiliation(s)
- Yanning Chen
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Xuedong Bai
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Mengxiao Xu
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Tianyu Zhou
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - Yee Man Loh
- State Key Laboratory of Ultra-precision Machining Technology, Department of Industrial and Systems Engineering, The Hong Kong Polytechnic University, Hong Kong, PR China
| | - Chunjin Wang
- State Key Laboratory of Ultra-precision Machining Technology, Department of Industrial and Systems Engineering, The Hong Kong Polytechnic University, Hong Kong, PR China
| | - Edmond Ho Nang Pow
- Prosthodontics, Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China
| | - James Kit Hon Tsoi
- Dental Materials Science, Applied Oral Sciences and Community Dental Care, Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, PR China.
| |
Collapse
|
4
|
Prodan D, Moldovan M, Cuc S, Sarosi C, Petean I, Filip M, Carpa R, Doukeh R, Mirica IC. Advanced Dentistry Biomaterials Containing Graphene Oxide. Polymers (Basel) 2024; 16:1743. [PMID: 38932093 PMCID: PMC11207353 DOI: 10.3390/polym16121743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2024] [Revised: 06/12/2024] [Accepted: 06/17/2024] [Indexed: 06/28/2024] Open
Abstract
The aim of this study was to obtain three experimental resin-based cements containing GO and HA-Ag for posterior restorations. The samples (S0, S1, and S2) shared the same polymer matrix (BisGMA, TEGDMA) and powder mixture (bioglass (La2O3 and Sr-Zr), quartz, GO, and HA-Ag), with different percentages of graphene oxide (0%, 0.1%, 0.2% GO) and silver-doped hydroxyapatite (10%, 9.9%, 9.8% HA-Ag). The physical-chemical properties (water absorption, degree of conversion), mechanical properties (DTS, CS, FS), structural properties (SEM, AFM), and antibacterial properties (Staphylococcus aureus, Enterococcus faecalis, Streptococcus mutans, Porphyromonas gingivalis, and Escherichia coli) were investigated. The results showed that the mechanical properties, except for the diametral tensile test, increased with the rise in the %GO. After 28 days, water absorption increased with the rise in the %GO. The surface structure of the samples did not show major changes after water absorption for 28 days. The antibacterial effects varied depending on the samples and bacterial strains tested. After increasing the %GO and decreasing the %HA-Ag, we observed a more pronounced antibacterial effect. The presence of GO, even in very small percentages, improved the properties of the tested experimental cements.
Collapse
Affiliation(s)
- Doina Prodan
- Raluca Ripan Institute for Research in Chemistry, Babeș-Bolyai University, 30 Fantanele Str., 400294 Cluj-Napoca, Romania; (D.P.); (M.M.); (S.C.); (M.F.)
| | - Marioara Moldovan
- Raluca Ripan Institute for Research in Chemistry, Babeș-Bolyai University, 30 Fantanele Str., 400294 Cluj-Napoca, Romania; (D.P.); (M.M.); (S.C.); (M.F.)
| | - Stanca Cuc
- Raluca Ripan Institute for Research in Chemistry, Babeș-Bolyai University, 30 Fantanele Str., 400294 Cluj-Napoca, Romania; (D.P.); (M.M.); (S.C.); (M.F.)
| | - Codruţa Sarosi
- Raluca Ripan Institute for Research in Chemistry, Babeș-Bolyai University, 30 Fantanele Str., 400294 Cluj-Napoca, Romania; (D.P.); (M.M.); (S.C.); (M.F.)
| | - Ioan Petean
- Faculty of Chemistry and Chemical Engineering, Babes-Bolyai University, 11 Arany János Str., 400028 Cluj-Napoca, Romania;
| | - Miuța Filip
- Raluca Ripan Institute for Research in Chemistry, Babeș-Bolyai University, 30 Fantanele Str., 400294 Cluj-Napoca, Romania; (D.P.); (M.M.); (S.C.); (M.F.)
| | - Rahela Carpa
- Department of Molecular Biology and Biotechnology, Faculty of Biology and Geology, Babes Bolyai University, 1 M. Kogalniceanu Street, 400084 Cluj-Napoca, Romania;
| | - Rami Doukeh
- Department of Well Drilling, Extraction and Transport of Hydrocarbons, Faculty of Petroleum Refining and Petrochemistry, Petroleum-Gas University of Ploiesti, 39 Bucharest Blvd, 100680 Ploiesti, Romania
| | - Ioana-Codruta Mirica
- Department of Oral Health, Iuliu Hatieganu University of Medicine and Pharmacy, 15 Victor Babeș Str., 400347 Cluj-Napoca, Romania;
| |
Collapse
|
5
|
Alghazzawi TF. The effects of monomer type, filler size, and filler content of three resin cements on the color stability of laminate veneers exposed to accelerated aging. Dent Mater 2024:S0109-5641(24)00135-0. [PMID: 38902146 DOI: 10.1016/j.dental.2024.06.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 05/30/2024] [Accepted: 06/03/2024] [Indexed: 06/22/2024]
Abstract
STATEMENT OF PROBLEM Commercially available resin cements consist of various filler sizes, filler content and monomers, and it is unclear which of these factors have the greatest effect on the color stability of laminate veneers. OBJECTIVES To evaluate the color stability of lithium disilicate-reinforced laminate veneers inserted with three commercial resin cements with various filler sizes/contents and monomers upon accelerated aging. METHODS Veneers were fabricated and cemented on resin abutments using three commercially available resin cements comprised of two different monomers and varying filler sizes/contents: 1) triethylene glycol dimethacrylate, TEGDMA (RelyX™ Veneer = 0.6 µm/66 %, Calibra® Esthetic Light Cure =1.2 µm/65 %); and 2) urethane dimethacrylate, UDMA (Variolink Esthetic LC = 0.1 µm/38 %). A total of 60 specimens were fabricated (n = 20 for each cement). The relative number of particles (N) and relative surface area (A) were calculated for each filler size/content. Color coordinates (L*, a*, b*) were measured, and color change (ΔE00) was calculated after cementation and following aging at 150, 300, 450, and 600 h using xenon light. Differences in color coordinates and color change were determined using repeated measures ANOVA followed by Tukey's post hoc test (α = .05). A post-hoc power analysis was performed to confirm reliability of the results. RESULTS Based on a post-hoc power analysis of a repeated measures ANOVA with two between-factors and 1 within-factor, we had 89 % power to detect a difference of effect by cement type, 10 % power to detect a difference by shade, and 100 % power to detect a difference of effect by aging. The UDMA-based cement (0.1 µm/38 %) was least affected by aging, despite having the largest number of particles (N = 1010) and largest particle surface area (A = 7.02). The TEGDMA-based cements exhibited a significant color change, with 0.6 µm/66 % (A = 2.03, N = 8.12) producing a larger ΔE00 than 1.2 µm/65 % (A = 1.00, N = 1.00). CONCLUSIONS Among the commercial cements tested, UDMA-based resin (0.1 µm/38 %) provided better color stability than TEGDMA-based resin cements. The color change after aging was affected by the relative surface area and relative number of particles for the TEGDMA-based resin cement (0.6 µm/66 % and 1.2 µm/65 %), with a larger surface area and a higher relative number of particles, accelerated color change with aging. The present study demonstrates a novel approach to determine color stability for any resin cement with particulate filler. CLINICAL IMPLICATIONS The dental practitioner should be selective in choosing a commercial light cure cementation product for laminate veneers, as UDMA containing resin cement is more resistant to color changes over time than TEGDMA, regardless of the filler size/content.
Collapse
Affiliation(s)
- Tariq F Alghazzawi
- Department of Substitutive Dental Sciences, Taibah University, Madinah 42353, Kingdom of Saudi Arabia; Department of Mechanical and Materials Engineering, The University of Alabama at Birmingham, Birmingham, AL 35294, USA.
| |
Collapse
|
6
|
Chen S, Zhu J, Yu M, Jin C, Huang C. Effect of aging and bleaching on the color stability and surface roughness of a recently introduced single-shade composite resin. J Dent 2024; 143:104917. [PMID: 38431188 DOI: 10.1016/j.jdent.2024.104917] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 02/26/2024] [Accepted: 02/28/2024] [Indexed: 03/05/2024] Open
Abstract
OBJECTIVES To assess the effects of aging and bleaching procedures on the color stability and surface roughness of a new single-shade composite versus multi-shade composite resins. METHODS A single-shade composite resin (Charisma Diamond One, CDO) and 3 multi-shade composite resins (Tetric NCeram, Filtek Z350 XT, Clearfil Majesty Posterior) were tested. Thirty specimens of each material were subjected to one of the aging procedures respectively: immersion in distilled water (12 days/37 °C), immersion in coffee (12 days/37 °C), or water thermocycling (10,000 cycles/5-55 °C). All specimens underwent in-office bleaching after aging. Kruskal-Wallis tests and analysis of variance were used for statistical analysis (α=0.05). RESULTS All materials exhibited a change of color (ΔE00), translucency (RTP), whiteness (WID) and surface roughness parameters (Sa,Sv) after aging and bleaching procedures. CDO showed the highest ΔE00 among all resins with the highest RTP value, regardless of the aging procedures. Immersion in coffee led to the significantly highest ∆E00 values and lowest RTP values for nearly all resins. Positive ΔWID1 (WID(bleaching)-WID(baseline)) values were found in distilled water immersion and thermocycling groups, while negative ΔWID1 values were found in the coffee immersion group for all materials. Besides, positive ΔWID2 (WID(bleaching)-WID(aging)) values were found in all aging groups for nearly all materials. All materials showed an increasing trend in Sa and Sv after bleaching. CONCLUSIONS CDO showed more pronounced discoloration than multi-shade composite resins. Although the whiteness of all resins increased after bleaching, none was completely restored in the coffee immersion group. Bleaching significantly increased the surface roughness of all materials. CLINICAL SIGNIFICANCE Charisma Diamond One is more susceptible to discoloration, which may affect its long-term success rate. Bleaching could partially reduce the color change of the composite resins but did not return them completely to their original state. The roughness of the resins increased after bleaching, prompting dentists to repolish them after bleaching.
Collapse
Affiliation(s)
- Siyang Chen
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) & Key Laboratory of Oral Biomedicine Ministry of Education, School & Hospital of Stomatology, Wuhan University, Luoyu Road 237, Wuhan, Hubei 430079, PR China
| | - Jiakang Zhu
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) & Key Laboratory of Oral Biomedicine Ministry of Education, School & Hospital of Stomatology, Wuhan University, Luoyu Road 237, Wuhan, Hubei 430079, PR China
| | - Miaoyang Yu
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) & Key Laboratory of Oral Biomedicine Ministry of Education, School & Hospital of Stomatology, Wuhan University, Luoyu Road 237, Wuhan, Hubei 430079, PR China
| | - Chunxiao Jin
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) & Key Laboratory of Oral Biomedicine Ministry of Education, School & Hospital of Stomatology, Wuhan University, Luoyu Road 237, Wuhan, Hubei 430079, PR China
| | - Cui Huang
- The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) & Key Laboratory of Oral Biomedicine Ministry of Education, School & Hospital of Stomatology, Wuhan University, Luoyu Road 237, Wuhan, Hubei 430079, PR China.
| |
Collapse
|
7
|
Saber EH, Abielhassan MH, Abed YA, Fahim SE. Color Stability of Bioactive Restorative Material vs Nanohybrid Resin Composite: An In Vitro Study. J Contemp Dent Pract 2024; 25:221-225. [PMID: 38690693 DOI: 10.5005/jp-journals-10024-3654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Abstract
AIM This study aimed to assess the color stability of bioactive restorative materials vs nanohybrid resin composites after 3 months of immersion in three frequently consumed beverages. MATERIALS AND METHODS Thirty disk-shaped specimens of Giomer dental restorative material (Shofu, Japan) and nanohybrid resin composite (Tokuyama, Japan) were performed using a Teflon mold. Super-Snap system (Shofu, Japan) was utilized to finish and polish the specimens to be preserved for 24 hours in distilled water at 37°C. The samples had been divided into three subgroups (Coffee, tea, Pepsi) (n = 5). The initially displayed color measurements of the samples were performed using a spectrophotometer (VITA Easyshade® V). After 7 days, 30 days, and 90 days, color measurements were repeated, and the E of each sample was estimated. E of each sample was calculated. RESULTS The Giomer group showed statistically significant higher E values than the nanohybrid resin composite where the p-value was ≤0.0001. Tea subgroup showed the highest statistically significant E values in both groups where the p-value was ≤ 0.0001. The highest statistically significant color change was recorded at 3 months. CONCLUSION The color of bioactive restorative material is less stable if compared with nanohybrid resin composite. CLINICAL SIGNIFICANCE As tea and coffee are popular beverages, particularly in Middle Eastern nations, dentists must advise patients about the color change of resin restorations. Patients are advised to brush their teeth immediately after consuming these beverages. How to cite this article: Saber EH, Abielhassan MH, Abed YA, et al. Color Stability of Bioactive Restorative Material vs Nanohybrid Resin Composite: An In Vitro Study. J Contemp Dent Pract 2024;25(3):221-225.
Collapse
Affiliation(s)
- Esraa H Saber
- Department of Conservative Dentistry, Faculty of Dentistry, October 6 University, Giza, Egypt, Phone: +00201010200882, e-mail: , Orcid: https://orcid.org/0009-0004-3752-0533
| | - Mohsen H Abielhassan
- Department of Conservative Dentistry, Faculty of Dentistry, October 6 University, Giza, Egypt, Orcid: https://orcid.org/0000-0002-8169-5793
| | - Yasser A Abed
- Department of Conservative Dentistry, Faculty of Dentistry, October 6 University, Giza, Egypt, Orcid: https://orcid.org/0009-0002-8738-7238
| | - Shereen E Fahim
- Department of Conservative Dentistry, Faculty of Dentistry, October 6 University, Giza, Egypt, Orcid: https://orcid.org/0000-0002-0597-5662
| |
Collapse
|
8
|
Wulff J, Rauch A, Schmidt MB, Rosentritt M. Biaxial Flexural Strength of Printed Splint Materials. MATERIALS (BASEL, SWITZERLAND) 2024; 17:1112. [PMID: 38473585 PMCID: PMC10934272 DOI: 10.3390/ma17051112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 01/14/2024] [Accepted: 02/27/2024] [Indexed: 03/14/2024]
Abstract
One therapeutical alternative in the treatment of functional disorders is the use of printed oral splints. The mechanical properties of these materials are highly essential to their clinical effectiveness, and their performance may vary depending on factors such as cleaning, post-polymerization, or their orientation during construction. The objective of this in vitro investigation is to evaluate the effectiveness of the selected materials in terms of their biaxial flexural strength in relation to the criteria listed above. Splint materials were used in the printing of 720 discs. The printing process was carried out in different orientations in relation to the building platform. Either an automatic or manual cleaning process was performed on the samples. For post-polymerization, either an LED or Xenon light was utilized. A piston-on-three-ball test was used to measure the biaxial flexural strength (BFS) of the materials after they were stored in water for either 24 h or 60 days. The homogeneity of the data was controlled by employing the Levene method, and the differences between the groups were analyzed using the ANOVA and Bonferroni methods. After being stored for twenty-four hours, the mean BFS ranged anywhere from 79 MPa to 157 MPa. Following a period of sixty hours, the BFS exhibited a substantial drop and revealed values that ranged from 72 to 127 MPa. There was no significant difference that could be identified between the materials or between the various cleaning processes. The results of post-polymerization showed that the LED light produced higher means than the Xenon light did. In terms of position, the mean values varied greatly, with 0°'s mean value being 101 MPa, 45°'s mean value being 102 MPa, and 90°'s mean value being 115 MPa. The use of a build orientation of 90° and post-polymerization with LED light resulted in significantly increased biaxial flexural strength. According to this study, this design should be implemented in order to ensure that splint materials have the highest possible strength.
Collapse
Affiliation(s)
| | | | | | - Martin Rosentritt
- Department of Prosthetic Dentistry, UKR University Hospital Regensburg, 93042 Regensburg, Germany; (J.W.); (A.R.); (M.B.S.)
| |
Collapse
|
9
|
Abuljadayel R, Mushayt A, Al Mutairi T, Sajini S. Evaluation of Bioactive Restorative Materials' Color Stability: Effect of Immersion Media and Thermocycling. Cureus 2023; 15:e43038. [PMID: 37674947 PMCID: PMC10479958 DOI: 10.7759/cureus.43038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/06/2023] [Indexed: 09/08/2023] Open
Abstract
OBJECTIVES One of the most important aspects that determines the clinical lifetime of aesthetic restorations, is the color stability (CS) over the long term. This study aims to assess the effect of artificial aging and thermocycling in different staining solutions on the CS of bioactive restorative materials compared to conventional ones. METHODS The following four material groups were investigated: ACTIVA™ Bioactive (AB) (Pulpdent Corporation, Massachusetts, United States), Beautifil II (BF) (SHOFU Inc., Kyoto, Japan), Fuji II (FJ) (GC Corporation, Tokyo Japan), and Filtek™ Z350 XT (FT) (3M, Minnesota, United States). A total of 100 specimens were fabricated using an acrylic mold and then immersed in five staining solutions groups: coffee, black tea, Cola, mixed berry juice, and saline. Baseline shade (T0) was recorded using two spectro-photometer devices, VITA Easyshade® Advance (VITA Zahnfabrik, Baden-Wurttemberg, Germany) and Color-Eye® 7000A (X-Rite, Inc., Grand Rapids, Michigan, United States). Following this, the shade was recorded at 30 days (T1), three months (T2), and after 5000 thermocycles (5C-55C) (T3). CIE L*a*b* (International Commission on Illumination color space) data was used to calculate ΔE for each group. RESULTS All samples showed a significant color change (P<0.001) following one and three months of storage and after thermocycling. AB and BF showed the highest CS over time, whereas FT and FJ showed the least CS. CONCLUSION The CS of restorative materials is mostly determined by their type, followed by staining solution type and thermocycling. The most potent solutions were coffee, tea, and berry juice.
Collapse
Affiliation(s)
- Roaa Abuljadayel
- Restorative and Aesthetic Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, SAU
| | - Ali Mushayt
- General Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, SAU
| | - Talal Al Mutairi
- General Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, SAU
| | - Shara Sajini
- Restorative and Aesthetic Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, SAU
| |
Collapse
|
10
|
Zubrzycki J, Klepka T, Marchewka M, Zubrzycki R. Tests of Dental Properties of Composite Materials Containing Nanohybrid Filler. MATERIALS (BASEL, SWITZERLAND) 2022; 16:348. [PMID: 36614687 PMCID: PMC9821974 DOI: 10.3390/ma16010348] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 12/20/2022] [Accepted: 12/21/2022] [Indexed: 06/17/2023]
Abstract
Complex composite materials are used in many areas of dentistry. Initially, chemically hardened materials were also used, and in this group nanohybrid composites are highly valued. They are often used today, mainly for the direct reconstruction of damaged hard tooth tissue materials for rebuilding damaged tissues using indirect adhesive techniques. The research was conducted to determine the mechanical properties of materials with nanofillers. The article focuses on methods of important test methods for dental prosthetics: resilience, abrasion, wear test, impact strength, hardness, SEM, and chemical analysis. As part of this work, five different series of hybrid composites with nano-fillers were tested. The mechanical properties of composites, such as compressive strength, microhardness, flexural strength, and modulus of elasticity, depend mainly on the type, particle size, and amount of filler introduced. The obtained test results showed that the type and amount of nanofiller have a significant influence on the mechanical and tribological properties. The introduction of nanofillers allowed us to obtain higher mechanical properties compared to classic materials discussed by other researchers. The study observed a change in vibrations in the IR spectrum, which allowed a comparison of the organic structures of the studied preparations.
Collapse
Affiliation(s)
- Jarosław Zubrzycki
- Department of Computerization and Robotization of Production, Lublin University of Technology, 20-618 Lublin, Poland
| | - Tomasz Klepka
- Department of Technology and Polymer Processing, Lublin University of Technology, 20-618 Lublin, Poland
| | - Magdalena Marchewka
- Department of Computerization and Robotization of Production, Lublin University of Technology, 20-618 Lublin, Poland
| | - Robert Zubrzycki
- Department of Dentistry, Medical University of Lublin, 20-059 Lublin, Poland
| |
Collapse
|
11
|
Lee SY, Lim JH, Kim D, Lee DH, Kim SG, Kim JE. Evaluation of the color stability of 3D printed resin according to the oxygen inhibition effect and temperature difference in the post-polymerization process. J Mech Behav Biomed Mater 2022; 136:105537. [PMID: 36327665 DOI: 10.1016/j.jmbbm.2022.105537] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 10/15/2022] [Accepted: 10/19/2022] [Indexed: 11/06/2022]
Abstract
The aim of this study was to determine the color stability of 3D printed resin according to the post-curing conditions (polymerization conditions and temperature). Specimens were post-polymerized under different conditions of oxygen inhibition, such as on glycerin immersion (GLY), medium-low vacuum environment (VA), and oxygen contact (CON, the control group), and temperature (35 °C, 60 °C, and 80 °C). The degree of conversion (DC), water sorption (Wsp) and solubility (Wsl), surface roughness (Ra) were measured. Additionally, surface free energy (SFE), pH values of colorants were measured. Grape juice (grape), coffee, and curry were used as the colorants, and distilled water (DW) was used as a control. And the color value was measured before and after immersion using a spectrophotometer. Then, Calculated the color change. For statistical methods, The Shapiro-Wilk test performed to check for normality revealed that the data presented a normal distribution (p>0.05). ΔE values were analyzed using three-way ANOVA. DC, Wsp, Wsl, SFE, and Ra were analyzed using two-way ANOVA. To confirm the linear correlation, Pearson's correlation coefficient was determined. The threshold for significance (p) was set at 0.05 (95% confidence interval) for all tests. DC was the highest at 80 °C in the GLY group (95.08 ± 4.88%). And Wsl decreased with increasing temperature, and was lowest at 80 °C in the GLY group (0.46 ± 0.30 um/mm3). After the colorants were immersed for 30 days, as the temperature increased, ΔE decreased in the GLY group but not in the VA and CON groups, and was the lowest at 80 °C in the GLY group: (DW, 0.95 ± 0.45 [mean± SD]; grape, 6.45± 0.69; coffee, 4.50± 0.56; curry, 9.37± 1.40). There was also a significant inverse relation between DC and ΔE. A significant inverse relation was found between Wsl and DC, and a significant positive correlation was found between Wsl and ΔE. Wsp, SFE, and Ra did not affect color stability. In the post-polymerization process, increasing the temperature and GLY were effective in reducing ΔE, which was lowest at 80 °C in the GLY group. It was also observed that a complex mechanism between the DC, Wsl of 3D printed resin affects ΔE of the resin.
Collapse
Affiliation(s)
- Sang-Yub Lee
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea; Department of Prosthodontics, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Ilwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Jung-Hwa Lim
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Dohyun Kim
- Department of Conservative Dentistry, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
| | - Dong-Hwan Lee
- Department of Prosthodontics, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Ilwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Seok Gyu Kim
- Department of Prosthodontics, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Ilwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea
| | - Jong-Eun Kim
- Department of Prosthodontics, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea.
| |
Collapse
|