1
|
Martinez-Mondragon M, Urriolagoitia-Sosa G, Romero-Ángeles B, García-Laguna MA, Laguna-Canales AS, Pérez-Partida JC, Mireles-Hernández J, Carrasco-Hernández F, Urriolagoitia-Calderón GM. Biomechanical Fatigue Behavior of a Dental Implant Due to Chewing Forces: A Finite Element Analysis. MATERIALS (BASEL, SWITZERLAND) 2024; 17:1669. [PMID: 38612181 PMCID: PMC11012472 DOI: 10.3390/ma17071669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 03/20/2024] [Accepted: 03/26/2024] [Indexed: 04/14/2024]
Abstract
The use of titanium as a biomaterial for the treatment of dental implants has been successful and has become the most viable and common option. However, in the last three decades, new alternatives have emerged, such as polymers that could replace metallic materials. The aim of this research work is to demonstrate the structural effects caused by the fatigue phenomenon and the comparison with polymeric materials that may be biomechanically viable by reducing the stress shielding effect at the bone-implant interface. A numerical simulation was performed using the finite element method. Variables such as Young's modulus, Poisson's coefficient, density, yield strength, ultimate strength, and the S-N curve were included. Prior to the simulation, a representative digital model of both a dental implant and the bone was developed. A maximum load of 550 N was applied, and the analysis was considered linear, homogeneous, and isotropic. The results obtained allowed us to observe the mechanical behavior of the dental implant by means of displacements and von Mises forces. They also show the critical areas where the implant tends to fail due to fatigue. Finally, this type of non-destructive analysis proves to be versatile, avoids experimentation on people and/or animals, and reduces costs, and the iteration is unlimited in evaluating various structural parameters (geometry, materials, properties, etc.).
Collapse
Affiliation(s)
- Miguel Martinez-Mondragon
- Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Profesional Adolfo López Mateos Zacatenco, Edificio 5, 2do, Piso, Col. Lindavista, Del. Gustavo A. Madero, Ciudad de México C.P. 07320, Mexico; (B.R.-Á.)
| | - Guillermo Urriolagoitia-Sosa
- Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Profesional Adolfo López Mateos Zacatenco, Edificio 5, 2do, Piso, Col. Lindavista, Del. Gustavo A. Madero, Ciudad de México C.P. 07320, Mexico; (B.R.-Á.)
| | - Beatriz Romero-Ángeles
- Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Profesional Adolfo López Mateos Zacatenco, Edificio 5, 2do, Piso, Col. Lindavista, Del. Gustavo A. Madero, Ciudad de México C.P. 07320, Mexico; (B.R.-Á.)
| | - Miguel Angel García-Laguna
- Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Profesional Adolfo López Mateos Zacatenco, Edificio 5, 2do, Piso, Col. Lindavista, Del. Gustavo A. Madero, Ciudad de México C.P. 07320, Mexico; (B.R.-Á.)
| | - Aldo Saul Laguna-Canales
- Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Profesional Adolfo López Mateos Zacatenco, Edificio 5, 2do, Piso, Col. Lindavista, Del. Gustavo A. Madero, Ciudad de México C.P. 07320, Mexico; (B.R.-Á.)
| | - Juan Carlos Pérez-Partida
- Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Profesional Adolfo López Mateos Zacatenco, Edificio 5, 2do, Piso, Col. Lindavista, Del. Gustavo A. Madero, Ciudad de México C.P. 07320, Mexico; (B.R.-Á.)
| | - Jonatan Mireles-Hernández
- Universidad Abierta y a Distancia de México, División de Ciencias de la Salud, Biológicas y Ambientales, Av. Universidad 1200, Piso 1, Cuadrante 10, 1-2, Xoco, Alcaldía Benito Juárez, Ciudad de México C.P. 03330, Mexico
| | - Francisco Carrasco-Hernández
- Universidad Tecnológica de Durango, Mecatrónica y Energías Renovables, Carretera Durango-Mezquital, km 4.5 S/N, Gavino Santillán, Durango C.P. 34308, Mexico
| | - Guillermo Manuel Urriolagoitia-Calderón
- Instituto Politécnico Nacional, Escuela Superior de Ingeniería Mecánica y Eléctrica, Sección de Estudios de Posgrado e Investigación, Unidad Profesional Adolfo López Mateos Zacatenco, Edificio 5, 2do, Piso, Col. Lindavista, Del. Gustavo A. Madero, Ciudad de México C.P. 07320, Mexico; (B.R.-Á.)
| |
Collapse
|
2
|
Ahn S, Kim J, Baek S, Kim C, Jang H, Lee S. Toward Digital Twin Development for Implant Placement Planning Using a Parametric Reduced-Order Model. Bioengineering (Basel) 2024; 11:84. [PMID: 38247961 PMCID: PMC10813277 DOI: 10.3390/bioengineering11010084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2023] [Revised: 12/19/2023] [Accepted: 12/26/2023] [Indexed: 01/23/2024] Open
Abstract
Real-time stress distribution data for implants and cortical bones can aid in determining appropriate implant placement plans and improving the post-placement success rate. This study aims to achieve these goals via a parametric reduced-order model (ROM) method based on stress distribution data obtained using finite element analysis. For the first time, the finite element analysis cases for six design variables related to implant placement were determined simultaneously via the design of experiments and a sensitivity analysis. The differences between the minimum and maximum stresses obtained for the six design variables confirm that the order of their influence is: Young's modulus of the cancellous bone > implant thickness > front-rear angle > left-right angle > implant length. Subsequently, a one-dimensional (1-D) CAE solver was created using the ROM with the highest coefficient of determination and prognosis accuracy. The proposed 1-D CAE solver was loaded into the Ondemand3D program and used to implement a digital twin that can aid with dentists' decision making by combining various tooth image data to evaluate and visualize the adequacy of the placement plan in real time. Because the proposed ROM method does not rely entirely on the doctor's judgment, it ensures objectivity.
Collapse
Affiliation(s)
- Seokho Ahn
- Department of Digital Manufacturing, Hanbat National University, 125 Dongseo-daero, Yuseong-gu, Daejeon 34158, Republic of Korea; (S.A.); (S.L.)
| | - Jaesung Kim
- Department of Industry-Academic Convergence, Hanbat National University, 125 Dongseo-daero, Yuseong-gu, Daejeon 34158, Republic of Korea
| | - Seokheum Baek
- Digital Platform Team, DNDE Inc., Busan 48059, Republic of Korea;
| | - Cheolyong Kim
- Implant Research Laboratory, Cybermed 6-26, Yuseong-daro 1205 beon-gil, Yuseong-gu, Daejeon 34104, Republic of Korea; (C.K.); (H.J.)
| | - Hyunsoo Jang
- Implant Research Laboratory, Cybermed 6-26, Yuseong-daro 1205 beon-gil, Yuseong-gu, Daejeon 34104, Republic of Korea; (C.K.); (H.J.)
| | - Seojin Lee
- Department of Digital Manufacturing, Hanbat National University, 125 Dongseo-daero, Yuseong-gu, Daejeon 34158, Republic of Korea; (S.A.); (S.L.)
| |
Collapse
|