1
|
Wu W, Tanweer S, Tapia-Orihuela RKA, Munjal P, Trivedi YV, Zhao S, Zafar H, Darapaneni H, Dasari VS, Lee C, Bhat RR, Kassab GS, Chatzizisis YS. Hemodynamic microenvironment of coronary stent strut malapposition. Comput Biol Med 2025; 184:109378. [PMID: 39549532 DOI: 10.1016/j.compbiomed.2024.109378] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2024] [Revised: 10/03/2024] [Accepted: 11/06/2024] [Indexed: 11/18/2024]
Abstract
OBJECTIVE This study aims to investigate the micro-hemodynamic effects of strut malapposition in patient-specific stented coronary bifurcations. METHODS Using the mapping-back technique, three-dimensional reconstructions of clinical post-stenting artery bifurcations with strut malapposition were accurately generated from optical coherence tomography scans of 9 patients. Computational fluid dynamics (CFD) simulations were then conducted with these models to examine the impact of strut malapposition on various fluid dynamic parameters, including flow patterns, vorticity, strain rates, viscosity, and wall shear stress (WSS). For statistical analysis, virtually apposed models were created to evaluate WSS metrics. Additionally, follow-up data for 5 out of the 9 patients were reviewed to assess evidence of late thrombosis and restenosis. RESULTS Malapposed struts induce significant alterations in flow dynamics, including the formation of recirculation regions and the transition from laminar to disturbed flow. The local curvature of the lumen also affects the development of these recirculation regions. Our study demonstrates, for the first time, that the vorticity on the abluminal side of malapposed struts exhibits an opposite sign compared to the surrounding region. The strain rate around these struts shows a distinct transition, with high values at the stent surface that rapidly diminish within the strut-lumen gap. This transition is accompanied by an increase in viscosity within these regions. Furthermore, as the malapposition distance increases, strain rates on the malapposed struts increase while viscosity decreases. Significant differences in WSS metrics were observed between clinically malapposed and virtually apposed scenarios. In clinical follow-up cases, no evidence of thrombosis was found despite the complex micro-hemodynamics in these patients. CONCLUSION There is complex interplay between stent malapposition and hemodynamics within a patient-specific bifurcation. The significant impact of local lumen curvature on flow dynamics underscores the limitations of idealized artery models. Moreover, the absence of thrombosis in subsequent clinical follow-up cases suggests that additional factors, such as antiplatelet medication, may play a significant role in mitigating these risks.
Collapse
Affiliation(s)
- Wei Wu
- Center for Digital Cardiovascular Innovations, Cardiovascular Division, Miller School of Medicine, Miami, FL, USA
| | - Sartaj Tanweer
- Center for Digital Cardiovascular Innovations, Cardiovascular Division, Miller School of Medicine, Miami, FL, USA
| | - Ruben K A Tapia-Orihuela
- Center for Digital Cardiovascular Innovations, Cardiovascular Division, Miller School of Medicine, Miami, FL, USA
| | - Parth Munjal
- Center for Digital Cardiovascular Innovations, Cardiovascular Division, Miller School of Medicine, Miami, FL, USA
| | - Yash Vardhan Trivedi
- Center for Digital Cardiovascular Innovations, Cardiovascular Division, Miller School of Medicine, Miami, FL, USA
| | - Shijia Zhao
- Center for Digital Cardiovascular Innovations, Cardiovascular Division, Miller School of Medicine, Miami, FL, USA
| | - Hammad Zafar
- Center for Digital Cardiovascular Innovations, Cardiovascular Division, Miller School of Medicine, Miami, FL, USA
| | - Haritha Darapaneni
- Center for Digital Cardiovascular Innovations, Cardiovascular Division, Miller School of Medicine, Miami, FL, USA
| | - Vineeth S Dasari
- Center for Digital Cardiovascular Innovations, Cardiovascular Division, Miller School of Medicine, Miami, FL, USA
| | - Changkye Lee
- Center for Digital Cardiovascular Innovations, Cardiovascular Division, Miller School of Medicine, Miami, FL, USA
| | - Rakshita Ramesh Bhat
- Center for Digital Cardiovascular Innovations, Cardiovascular Division, Miller School of Medicine, Miami, FL, USA
| | - Ghassan S Kassab
- California Medical Innovation Institute, San Diego, CA, 92121, USA
| | - Yiannis S Chatzizisis
- Center for Digital Cardiovascular Innovations, Cardiovascular Division, Miller School of Medicine, Miami, FL, USA.
| |
Collapse
|
2
|
Wang J, Fan Z, Liu J, Liu K, Yan C, Ye X, Deng X. Influence of stent strut and its associated injury on thrombus formation: A dissipative particle dynamics study. J Theor Biol 2024; 595:111929. [PMID: 39197677 DOI: 10.1016/j.jtbi.2024.111929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Revised: 08/17/2024] [Accepted: 08/19/2024] [Indexed: 09/01/2024]
Abstract
Vascular stent intervention is a pivotal treatment for coronary atherosclerosis, though in-stent thrombosis remains a significant postoperative complication with an unclear underlying mechanism. This study utilized dissipated particle dynamics analysis to investigate the impact of stent and its injury on platelet behavior. The findings suggest that thrombus formation upstream of the stent is mainly initiated by upstream arterial injury, which leads to increased platelet accumulation and activation in that area. While thrombosis downstream of the stent is more directly influenced by the stent itself. The morphology and size of in-stent thrombosis can vary significantly due to the different contributions of the stent and underlying injuries. Additionally, the volume of in-stent thrombosis is affected by the extent of the injury and the viscosity of platelets, showing a notable increase in volume with the lengthening of the injury area and rise in platelet viscosity. This study provides a novel theoretical framework for optimizing stent placement strategies and structural designs by examining the effects of stent struts and associated injuries on thrombus formation.
Collapse
Affiliation(s)
- Jian Wang
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, China
| | - Zhenmin Fan
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, China.
| | - Jiashuai Liu
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, China
| | - Kailei Liu
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, China
| | - ChaoJun Yan
- Cardiac Surgery Department, Southwest Hospital, Army Medical University, Chongqing 400038, China.
| | - Xia Ye
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, China
| | - Xiaoyan Deng
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou, Jiangsu 213001, China; Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China
| |
Collapse
|
3
|
Khairulin A, Kuchumov AG, Silberschmidt VV. In silico model of stent performance in multi-layered artery using 2-way fluid-structure interaction: Influence of boundary conditions and vessel length. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 255:108327. [PMID: 39018788 DOI: 10.1016/j.cmpb.2024.108327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 06/29/2024] [Accepted: 07/12/2024] [Indexed: 07/19/2024]
Abstract
BACKGROUND AND OBJECTIVE Atherosclerotic lesions of coronary arteries (stenosis) are caused by the buildup of lipids and blood-borne substances within the artery wall. Their qualitative and rapid assessment is still a challenging task. The primary therapy for this pathology involves implanting coronary stents, which help to restore the blood flow in atherosclerosis-prone arteries. In-stent restenosis is a stenting-procedure complication detected in about 10-40% of patients. A numerical study using 2-way fluid-structure interaction (FSI) assesses the stenting procedure quality and can decrease the number of negative post-operative results. Nevertheless, boundary conditions (BCs) used in simulation play a crucial role in implementation of an adequate computational analysis. METHODS Three CoCr stents designs were modelled with the suggested approach. A multi-layer structure describing the artery and plaque with anisotropic hyperelastic mechanical properties was adopted in this study. Two kinds of boundary conditions for a solid domain were examined - fixed support (FS) and remote displacement (RD) - to assess their impact on the hemodynamic parameters to predict restenosis. Additionally, the influence of artery elongation (short-artery model vs. long-artery model) on numerical results with the FS boundary condition was analyzed. RESULTS The comparison of FS and RD boundary conditions demonstrated that the variation of hemodynamic parameters values did not exceed 2%. The analysis of short-artery and long-artery models revealed that the difference in hemodynamic parameters was less than 5.1%, and in most cases, it did not exceed 2.5%. The RD boundary conditions were found to reduce the computation time by up to 1.7-2.0 times compared to FS. Simple stent model was shown to be susceptible to restenosis development, with maximum WSS values equal to 183 Pa, compared to much lower values for other two stents. CONCLUSIONS The study revealed that the stent design significantly affected the hemodynamic parameters as restenosis predictors. Moreover, the stress-strain state of the system artery-plaque-stent also depends on a proper choice of boundary conditions.
Collapse
Affiliation(s)
- Aleksandr Khairulin
- Department of Computational Mathematics, Mechanics and Biomechanics, Perm National Research Polytechnic University, Komsomolskiy prospect 29, Perm 614990, Russia; Biofluids Laboratory, Perm National Research Polytechnic University, Komsomolskiy prospect 29, Perm 614990, Russia
| | - Alex G Kuchumov
- Department of Computational Mathematics, Mechanics and Biomechanics, Perm National Research Polytechnic University, Komsomolskiy prospect 29, Perm 614990, Russia; Biofluids Laboratory, Perm National Research Polytechnic University, Komsomolskiy prospect 29, Perm 614990, Russia.
| | - Vadim V Silberschmidt
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, Leicestershire LE11 3TU, United Kingdom
| |
Collapse
|
4
|
Liu J, Fan Z, Ye X, Zhang Y, Liu M, Deng X. Modelling of the in-stent thrombus formation by dissipative particle dynamics. J Theor Biol 2024; 582:111758. [PMID: 38336241 DOI: 10.1016/j.jtbi.2024.111758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2023] [Revised: 12/05/2023] [Accepted: 01/30/2024] [Indexed: 02/12/2024]
Abstract
BACKGROUND Stent implantation is a highly efficacious intervention for the treatment of coronary atherosclerosis. Nevertheless, stent thrombosis and other post-operative complications persist, and the underlying mechanism of adverse event remains elusive. METHODS In the present study, a dissipative particle dynamics model was formulated to simulate the motion, adhesion, activation, and aggregation of platelets, with the aim of elucidating the mechanisms of in-stent thrombosis. FINDINGS The findings suggest that stent thrombosis arises from a complex interplay of multiple factors, including endothelial injury resulting from stent implantation and alterations in the hemodynamic milieu. Furthermore, the results suggest a noteworthy association between in-stent thrombosis and both the length of the endothelial injured site and the degree of stent malposition. Specifically, the incidence of stent thrombosis appears to rise in tandem with the extent of the injured site, while moderate stent malposition is more likely to result in in-stent thrombosis compared to severe or minor malposition. INTERPRETATION This study offers novel research avenues for investigating the plasticity mechanism of stent thrombosis, while also facilitating the clinical prediction of stent thrombosis formation and the development of more precise treatment strategies.
Collapse
Affiliation(s)
- Jiashuai Liu
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou Jiangsu 213001, China
| | - Zhenmin Fan
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou Jiangsu 213001, China.
| | - Xia Ye
- School of Mechanical Engineering, Jiangsu University of Technology, Changzhou Jiangsu 213001, China
| | - Yingying Zhang
- Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, National Research Center for Rehabilitation Technical Aids, Beijing 100176, China.
| | - Mingyuan Liu
- Department of Vascular Surgery, Beijing Friendship Hospital, Capital Medical University, Beijing Center of Vascular Surgery, Beijing 100050, China
| | - Xiaoyan Deng
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100191, China
| |
Collapse
|
5
|
Liu W, Wang X, Feng Y. Restoring endothelial function: shedding light on cardiovascular stent development. Biomater Sci 2023. [PMID: 37161519 DOI: 10.1039/d3bm00390f] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Complete endothelialization is highly important for maintaining long-term patency and avoiding subsequent complications in implanting cardiovascular stents. It not only refers to endothelial cells (ECs) fully covering the inserted stents, but also includes the newly formed endothelium, which could exert physiological functions, such as anti-thrombosis and anti-stenosis. Clinical outcomes have indicated that endothelial dysfunction, especially the insufficiency of antithrombotic and barrier functions, is responsible for stent failure. Learning from vascular pathophysiology, endothelial dysfunction on stents is closely linked to the microenvironment of ECs. Evidence points to inflammatory responses, oxidative stress, altered hemodynamic shear stress, and impaired endothelial barrier affecting the normal growth of ECs, which are the four major causes of endothelial dysfunction. The related molecular mechanisms and efforts dedicated to improving the endothelial function are emphasized in this review. From the perspective of endothelial function, the design principles, advantages, and disadvantages behind current stents are introduced to enlighten the development of new-generation stents, aiming to offer new alternatives for restoring endothelial function.
Collapse
Affiliation(s)
- Wen Liu
- School of Chemical Engineering and Technology, Tianjin University, Yaguan Road 135, Tianjin 300350, P. R. China.
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin), Weijin Road 92, Tianjin 300072, P. R. China
| | - Xiaoyu Wang
- School of Chemical Engineering and Technology, Tianjin University, Yaguan Road 135, Tianjin 300350, P. R. China.
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin), Weijin Road 92, Tianjin 300072, P. R. China
| | - Yakai Feng
- School of Chemical Engineering and Technology, Tianjin University, Yaguan Road 135, Tianjin 300350, P. R. China.
- Collaborative Innovation Center of Chemical Science and Chemical Engineering (Tianjin), Weijin Road 92, Tianjin 300072, P. R. China
- Key Laboratory of Systems Bioengineering (Ministry of Education), Tianjin University, Weijin Road 92, Tianjin 300072, P. R. China
- Frontiers Science Center for Synthetic Biology, Tianjin University, Weijin Road 92, Tianjin 300072, China
| |
Collapse
|
6
|
Finite Element Analysis of Fluid–Structure Interaction in a Model of an L-Type Mg Alloy Stent-Stenosed Coronary Artery System. METALS 2022. [DOI: 10.3390/met12071176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The coronary stent deployment and subsequent service process is a complex geometric/physical nonlinear and fluid–structure coupling system. Analyzing the distribution of stress–strain on the stent is of great significance in studying the deformation and failure behavior. A coupled system dynamics model comprising stenotic coronary artery vessels and L-type Mg alloy stents was established by applying the polynomial hyperelastic constitutive theory. The nonlinear, significant deformation behavior of the stent was systematically studied. The stress–strain distribution of the coupling system during stent deployment was analyzed. The simulation results show that the edges of the supporting body fixed without a bridge are the weakest zone. The stress changes on the inside of the wave of the supporting body are very large, and the residual stress accumulated in this area is the highest. The peak stress of the plaque and the arterial wall was lower than the damage threshold. The velocity of the blood between the wave crest of the supporting body is large and the streamline distribution is concentrated. In addition, the inner surface pressure on the stent is evenly distributed along its axial dimension. The maximum arterial wall shear stress always appears on the inside of the wave crest of the supporting body fixed with a bridge, and, as such, the largest obstacle to the blood flow is in this zone.
Collapse
|
7
|
Colombo M, Corti A, Gallo D, Colombo A, Antognoli G, Bernini M, McKenna C, Berceli S, Vaughan T, Migliavacca F, Chiastra C. Superficial femoral artery stenting: Impact of stent design and overlapping on the local hemodynamics. Comput Biol Med 2022; 143:105248. [PMID: 35124437 DOI: 10.1016/j.compbiomed.2022.105248] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Revised: 01/14/2022] [Accepted: 01/18/2022] [Indexed: 11/03/2022]
Abstract
BACKGROUND Superficial femoral arteries (SFAs) treated with self-expanding stents are widely affected by in-stent restenosis (ISR), especially in case of long lesions and multiple overlapping devices. The altered hemodynamics provoked by the stent is considered as a promoting factor of ISR. In this context, this work aims to analyze the impact of stent design and stent overlapping on patient-specific SFA hemodynamics. METHODS Through a morphing technique, single or multiple stents were virtually implanted within two patient-specific, post-operative SFA models reconstructed from computed tomography. The stented domains were used to perform computational fluid dynamics simulations, quantifying wall shear stress (WSS) based descriptors including time-averaged WSS (TAWSS), oscillatory shear index (OSI), transverse WSS (transWSS), and WSS ratio (WSSRATIO). Four stent designs (three laser-cut - EverFlex, Zilver and S.M.A.R.T. - and one prototype braided stent), and three typical clinical scenarios accounting for different order of stent implantation and overlapping length were compared. RESULTS The main hemodynamic differences were found between the two types of stent designs (i.e. laser-cut vs. braided stents). The braided stent presented lower median transWSS and higher median WSSRATIO than the laser-cut stents (p < 0.0001). The laser-cut stents presented comparable WSS-based descriptor values, except for the Zilver, exhibiting a median TAWSS ∼30% higher than the other stents. Stent overlapping provoked an abrupt alteration of the WSS-based descriptors. The overlapping length, rather than the order of stent implantation, highly and negatively impacted the hemodynamics. CONCLUSION The proposed computational workflow compared different SFA stent designs and stent overlapping configurations, highlighting those providing the most favorable hemodynamic conditions.
Collapse
Affiliation(s)
- Monika Colombo
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy; Institute for Chemical and Bioengineering, ETH Zurich, Zurich, Switzerland
| | - Anna Corti
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Diego Gallo
- PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Andrea Colombo
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Giacomo Antognoli
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Martina Bernini
- Biomechanics Research Centre (BioMEC), National University of Ireland Galway, Ireland
| | - Ciara McKenna
- Biomechanics Research Centre (BioMEC), National University of Ireland Galway, Ireland
| | - Scott Berceli
- Department of Surgery, University of Florida, Gainesville, FL, USA; Malcom Randall VAMC, Gainesville, FL, USA
| | - Ted Vaughan
- Biomechanics Research Centre (BioMEC), National University of Ireland Galway, Ireland
| | - Francesco Migliavacca
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Claudio Chiastra
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy; PoliTo(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.
| |
Collapse
|
8
|
Chiastra C, Mazzi V, Lodi Rizzini M, Calò K, Corti A, Acquasanta A, De Nisco G, Belliggiano D, Cerrato E, Gallo D, Morbiducci U. Coronary Artery Stenting Affects Wall Shear Stress Topological Skeleton. J Biomech Eng 2022; 144:1131202. [PMID: 35015058 DOI: 10.1115/1.4053503] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Indexed: 01/09/2023]
Abstract
Despite the important advancements in the stent technology for the treatment of diseased coronary arteries, major complications still affect the post-operative long-term outcome. The stent-induced flow disturbances, and especially the altered wall shear stress (WSS) profile at the strut level, play an important role in the pathophysiological mechanisms leading to stent thrombosis (ST) and in-stent restenosis (ISR). In this context, the analysis of the WSS topological skeleton is gaining more and more interest by extending the current understanding of the association between local hemodynamics and vascular diseases. The present study aims to analyze the impact that a deployed coronary stent has on the WSS topological skeleton. Computational fluid dynamics simulations were performed in three stented human coronary artery geometries reconstructed from clinical images. The selected cases presented stents with different designs (i.e., two contemporary drug eluting stents and one bioresorbable scaffold) and included regions with stent malapposition or overlapping. A recently proposed Eulerian-based approach was applied to analyze the WSS topological skeleton features. The results highlighted that the presence of single or multiple stents within a coronary artery markedly impacts the WSS topological skeleton. In particular, repetitive patterns of WSS divergence were observed at the luminal surface, highlighting a WSS contraction action proximal to the struts and a WSS expansion action distal to the struts. This WSS action pattern was independent from the stent design. In conclusions, these findings could contribute to a deeper understanding of the hemodynamic-driven processes underlying ST and ISR.
Collapse
Affiliation(s)
- Claudio Chiastra
- PoliToBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Valentina Mazzi
- PoliToBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Maurizio Lodi Rizzini
- PoliToBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Karol Calò
- PoliToBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Anna Corti
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Alessandro Acquasanta
- PoliToBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Giuseppe De Nisco
- PoliToBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Davide Belliggiano
- Cardiology Division, San Luigi Gonzaga University Hospital, Orbassano, Turin, Italy
| | - Enrico Cerrato
- Interventional Cardiology Unit, San Luigi Gonzaga University Hospital, Orbassano, and Rivoli Infermi Hospital, Rivoli, Turin, Italy
| | - Diego Gallo
- PoliToBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Umberto Morbiducci
- PoliToBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| |
Collapse
|
9
|
Gamage PT, Dong P, Lee J, Gharaibeh Y, Zimin VN, Dallan LAP, Bezerra HG, Wilson DL, Gu L. Hemodynamic alternations following stent deployment and post-dilation in a heavily calcified coronary artery: In silico and ex-vivo approaches. Comput Biol Med 2021; 139:104962. [PMID: 34715552 DOI: 10.1016/j.compbiomed.2021.104962] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 10/16/2021] [Accepted: 10/17/2021] [Indexed: 01/16/2023]
Abstract
In this work, hemodynamic alterations in a patient-specific, heavily calcified coronary artery following stent deployment and post-dilations are quantified using in silico and ex-vivo approaches. Three-dimensional artery models were reconstructed from OCT images. Stent deployment and post-dilation with various inflation pressures were performed through both the finite element method (FEM) and ex vivo experiments. Results from FEM agreed very well with the ex-vivo measurements, interms of lumen areas, stent underexpansion, and strut malapposition. In addition, computational fluid dynamics (CFD) simulations were performed to delineate the hemodynamic alterations after stent deployment and post-dilations. A pressure time history at the inlet and a lumped parameter model (LPM) at the outlet were adopted to mimic the aortic pressure and the distal arterial tree, respectively. The pressure drop across the lesion, pertaining to the clinical measure of instantaneous wave-free flow ratio (iFR), was investigated. Results have shown that post-dilations are necessary for the lumen gain as well as the hemodynamic restoration towards hemostasis. Malapposed struts induced much higher shear rate, flow disturbances and lower time-averaged wall shear stress (TAWSS) around struts. Post-dilations mitigated the strut malapposition, and thus the shear rate. Moreover, stenting induced larger area of low TAWSS (<0.4 Pa) and lager volume of high shear rate (>2000 s-1), indicating higher risks of in-stent restenosis (ISR) and stent thrombosis (ST), respectively. Oscillatory shear index (OSI) and relative residence time (RRT) indicated the wall regions more prone to ISR are located near the malapposed stent struts.
Collapse
Affiliation(s)
- Peshala T Gamage
- Department of Biomedical and Chemical Engineering and Sciences, Florida Institute of Technology, Melbourne, FL, 32901, USA
| | - Pengfei Dong
- Department of Biomedical and Chemical Engineering and Sciences, Florida Institute of Technology, Melbourne, FL, 32901, USA.
| | - Juhwan Lee
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Yazan Gharaibeh
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Vladislav N Zimin
- Cardiovascular Imaging Core Laboratory, Harrington Heart & Vascular Institute, University Hospitals Cleveland Medical Center, Cleveland, OH, 44106, USA
| | - Luis A P Dallan
- Cardiovascular Imaging Core Laboratory, Harrington Heart & Vascular Institute, University Hospitals Cleveland Medical Center, Cleveland, OH, 44106, USA
| | - Hiram G Bezerra
- Interventional Cardiology Center, Heart and Vascular Institute, The University of South Florida, Tampa, FL, 33606, USA
| | - David L Wilson
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Linxia Gu
- Department of Biomedical and Chemical Engineering and Sciences, Florida Institute of Technology, Melbourne, FL, 32901, USA.
| |
Collapse
|