1
|
Fattahi Z, Hasanzadeh M. Nanotechnology-assisted microfluidic systems platform for chemical and bioanalysis. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116637] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
2
|
Walper SA, Lasarte Aragonés G, Sapsford KE, Brown CW, Rowland CE, Breger JC, Medintz IL. Detecting Biothreat Agents: From Current Diagnostics to Developing Sensor Technologies. ACS Sens 2018; 3:1894-2024. [PMID: 30080029 DOI: 10.1021/acssensors.8b00420] [Citation(s) in RCA: 76] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Although a fundamental understanding of the pathogenicity of most biothreat agents has been elucidated and available treatments have increased substantially over the past decades, they still represent a significant public health threat in this age of (bio)terrorism, indiscriminate warfare, pollution, climate change, unchecked population growth, and globalization. The key step to almost all prevention, protection, prophylaxis, post-exposure treatment, and mitigation of any bioagent is early detection. Here, we review available methods for detecting bioagents including pathogenic bacteria and viruses along with their toxins. An introduction placing this subject in the historical context of previous naturally occurring outbreaks and efforts to weaponize selected agents is first provided along with definitions and relevant considerations. An overview of the detection technologies that find use in this endeavor along with how they provide data or transduce signal within a sensing configuration follows. Current "gold" standards for biothreat detection/diagnostics along with a listing of relevant FDA approved in vitro diagnostic devices is then discussed to provide an overview of the current state of the art. Given the 2014 outbreak of Ebola virus in Western Africa and the recent 2016 spread of Zika virus in the Americas, discussion of what constitutes a public health emergency and how new in vitro diagnostic devices are authorized for emergency use in the U.S. are also included. The majority of the Review is then subdivided around the sensing of bacterial, viral, and toxin biothreats with each including an overview of the major agents in that class, a detailed cross-section of different sensing methods in development based on assay format or analytical technique, and some discussion of related microfluidic lab-on-a-chip/point-of-care devices. Finally, an outlook is given on how this field will develop from the perspective of the biosensing technology itself and the new emerging threats they may face.
Collapse
Affiliation(s)
- Scott A. Walper
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
| | - Guillermo Lasarte Aragonés
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
- College of Science, George Mason University Fairfax, Virginia 22030, United States
| | - Kim E. Sapsford
- OMPT/CDRH/OIR/DMD Bacterial Respiratory and Medical Countermeasures Branch, U.S. Food and Drug Administration, Silver Spring, Maryland 20993, United States
| | - Carl W. Brown
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
- College of Science, George Mason University Fairfax, Virginia 22030, United States
| | - Clare E. Rowland
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
- National Research Council, Washington, D.C. 20036, United States
| | - Joyce C. Breger
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
| | - Igor L. Medintz
- Center for Bio/Molecular Science and Engineering, Code 6900, U.S. Naval Research Laboratory, Washington, D.C. 20375, United States
| |
Collapse
|
3
|
Khodayari Bavil A, Kim J. A capillary flow-driven microfluidic system for microparticle-labeled immunoassays. Analyst 2018; 143:3335-3342. [DOI: 10.1039/c8an00898a] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
A simple and sensitive capillary-driven microfluidic platform is designed and demonstrated for direct and sandwich microparticle-labeled immunoassays.
Collapse
Affiliation(s)
| | - Jungkyu Kim
- Department of Mechanical Engineering
- Texas Tech University
- Lubbock
- USA
| |
Collapse
|
4
|
Lee JR, Choi J, Shultz TO, Wang SX. Small Molecule Detection in Saliva Facilitates Portable Tests of Marijuana Abuse. Anal Chem 2016; 88:7457-61. [PMID: 27434697 DOI: 10.1021/acs.analchem.6b01688] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
As medical and recreational use of cannabis, or marijuana, becomes more prevalent, law enforcement needs a tool to evaluate whether drivers are operating vehicles under the influence of cannabis, specifically the psychoactive substance, tetrahydrocannabinol (THC). However, the cutoff concentration of THC that causes impairment is still controversial, and current on-site screening tools are not sensitive enough to detect trace amounts of THC in oral fluids. Here we present a novel sensing platform that employs giant magnetoresistive (GMR) biosensors integrated with a portable reader system and smartphone to detect THC in saliva using competitive assays. With a simple saliva collection scheme, we have optimized the assay to measure THC in the range from 0 to 50 ng/mL, covering most cutoff values proposed in previous studies. This work facilitates on-site screening for THC and shows potential for testing of other small molecule drugs and analytes in point-of-care (POC) settings.
Collapse
Affiliation(s)
- Jung-Rok Lee
- Department of Materials Science and Engineering, Stanford University , Stanford, California 94305, United States
| | - Joohong Choi
- Department of Electrical Engineering, Stanford University , Stanford, California 94305, United States
| | - Tyler O Shultz
- Department of Materials Science and Engineering, Stanford University , Stanford, California 94305, United States
| | - Shan X Wang
- Department of Materials Science and Engineering, Stanford University , Stanford, California 94305, United States.,Department of Electrical Engineering, Stanford University , Stanford, California 94305, United States
| |
Collapse
|
5
|
Turner AD, Higgins C, Higman W, Hungerford J. Potential Threats Posed by Tetrodotoxins in UK Waters: Examination of Detection Methodology Used in Their Control. Mar Drugs 2015; 13:7357-76. [PMID: 26690455 PMCID: PMC4699243 DOI: 10.3390/md13127070] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2015] [Revised: 11/30/2015] [Accepted: 12/07/2015] [Indexed: 12/27/2022] Open
Abstract
Tetrodotoxin is a neurotoxin responsible for many human fatalities, most commonly following the consumption of pufferfish. Whilst the source of the toxin has not been conclusively proven, it is thought to be associated with various species of marine bacteria. Whilst the toxins are well studied in fish and gastropods, in recent years, there have been a number of reports of tetrodotoxin occurring in bivalve shellfish, including those harvested from the UK and other parts of Europe. This paper reviews evidence concerning the prevalence of tetrodotoxins in the UK together with methodologies currently available for testing. Biological, biomolecular and chemical methods are reviewed, including recommendations for further work. With the recent development of quantitative chromatographic methods for these and other hydrophilic toxins, as well as the commercial availability of rapid testing kits, there are a number of options available to ensure consumers are protected against this threat.
Collapse
Affiliation(s)
- Andrew D Turner
- Centre for Environment Fisheries and Aquaculture Science (Cefas), Barrack Road, The Nothe, Weymouth, Dorset DT4 8UB, UK.
| | - Cowan Higgins
- Agri-food and Biosciences Institute (AFBI), Newforge Lane, Belfast BT9 5PX, UK.
| | - Wendy Higman
- Centre for Environment Fisheries and Aquaculture Science (Cefas), Barrack Road, The Nothe, Weymouth, Dorset DT4 8UB, UK.
| | - James Hungerford
- Pacific Laboratory Northwest, United States Food and Drug Administration (USFDA), 22201 23rd Dr, S.E., Bothell, WA 98021, USA.
| |
Collapse
|
6
|
Reverté L, de la Iglesia P, del Río V, Campbell K, Elliott CT, Kawatsu K, Katikou P, Diogène J, Campàs M. Detection of Tetrodotoxins in Puffer Fish by a Self-Assembled Monolayer-Based Immunoassay and Comparison with Surface Plasmon Resonance, LC-MS/MS, and Mouse Bioassay. Anal Chem 2015; 87:10839-47. [PMID: 26424329 DOI: 10.1021/acs.analchem.5b02158] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
The increasing occurrence of puffer fish containing tetrodotoxin (TTX) in the Mediterranean could represent a major food safety risk for European consumers and threaten the fishing industry. The work presented herein describes the development of a new enzyme linked immunosorbent assay (mELISA) based on the immobilization of TTX through dithiol monolayers self-assembled on maleimide plates, which provides an ordered and oriented antigen immobilization and favors the antigen-antibody affinity interaction. The mELISA was found to have a limit of detection (LOD) of TTX of 0.23 mg/kg of puffer fish matrix. The mELISA and a surface plasmon resonance (SPR) immunosensor previously developed were employed to establish the cross-reactivity factors (CRFs) of 5,6,11-trideoxy-TTX, 5,11-deoxy-TTX, 11-nor-TTX-6-ol, and 5,6,11-trideoxy-4-anhydro-TTX, as well as to determine TTX equivalent contents in puffer fish samples. Results obtained by both immunochemical tools were correlated (R(2) = 0.977). The puffer fish samples were also analyzed using liquid chromatography-tandem mass spectrometry (LC-MS/MS), and the corresponding CRFs were applied to the individual TTX contents. Results provided by the immunochemical tools, when compared with those obtained by LC-MS/MS, showed a good degree of correlation (R(2) = 0.991 and 0.979 for mELISA and SPR, respectively). The mouse bioassay (MBA) slightly overestimated the CRF adjusted TTX content of samples when compared with the data obtained from the other techniques. The mELISA has been demonstrated to be fit for the purpose for screening samples in monitoring programs and in research activities.
Collapse
Affiliation(s)
- Laia Reverté
- IRTA , Carretera Poble Nou km 5.5, 43540 Sant Carles de la Ràpita, Tarragona, Spain
| | - Pablo de la Iglesia
- IRTA , Carretera Poble Nou km 5.5, 43540 Sant Carles de la Ràpita, Tarragona, Spain
| | - Vanessa del Río
- IRTA , Carretera Poble Nou km 5.5, 43540 Sant Carles de la Ràpita, Tarragona, Spain
| | - Katrina Campbell
- Institute for Global Food Security, School of Biological Sciences, Queen's University , Stranmillis Road, Belfast BT9 5AG, Northern Ireland
| | - Christopher T Elliott
- Institute for Global Food Security, School of Biological Sciences, Queen's University , Stranmillis Road, Belfast BT9 5AG, Northern Ireland
| | - Kentaro Kawatsu
- Division of Bacteriology, Osaka Prefectural Institute of Public Health , 3-69, Nakamichi 1-chome, Higashinari-ku, Osaka 537-0025, Japan
| | - Panagiota Katikou
- National Reference Laboratory on Marine Biotoxins, Ministry of Rural Development and Food , 54627 Thessaloniki, Greece
| | - Jorge Diogène
- IRTA , Carretera Poble Nou km 5.5, 43540 Sant Carles de la Ràpita, Tarragona, Spain
| | - Mònica Campàs
- IRTA , Carretera Poble Nou km 5.5, 43540 Sant Carles de la Ràpita, Tarragona, Spain
| |
Collapse
|
7
|
Reverté L, Soliño L, Carnicer O, Diogène J, Campàs M. Alternative methods for the detection of emerging marine toxins: biosensors, biochemical assays and cell-based assays. Mar Drugs 2014; 12:5719-63. [PMID: 25431968 PMCID: PMC4278199 DOI: 10.3390/md12125719] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2014] [Revised: 11/11/2014] [Accepted: 11/11/2014] [Indexed: 12/02/2022] Open
Abstract
The emergence of marine toxins in water and seafood may have a considerable impact on public health. Although the tendency in Europe is to consolidate, when possible, official reference methods based on instrumental analysis, the development of alternative or complementary methods providing functional or toxicological information may provide advantages in terms of risk identification, but also low cost, simplicity, ease of use and high-throughput analysis. This article gives an overview of the immunoassays, cell-based assays, receptor-binding assays and biosensors that have been developed for the screening and quantification of emerging marine toxins: palytoxins, ciguatoxins, cyclic imines and tetrodotoxins. Their advantages and limitations are discussed, as well as their possible integration in research and monitoring programs.
Collapse
Affiliation(s)
- Laia Reverté
- IRTA, Carretera Poble Nou km 5.5, 43540 Sant Carles de la Ràpita, Spain.
| | - Lucía Soliño
- IRTA, Carretera Poble Nou km 5.5, 43540 Sant Carles de la Ràpita, Spain.
| | - Olga Carnicer
- IRTA, Carretera Poble Nou km 5.5, 43540 Sant Carles de la Ràpita, Spain.
| | - Jorge Diogène
- IRTA, Carretera Poble Nou km 5.5, 43540 Sant Carles de la Ràpita, Spain.
| | - Mònica Campàs
- IRTA, Carretera Poble Nou km 5.5, 43540 Sant Carles de la Ràpita, Spain.
| |
Collapse
|
8
|
Yakes BJ, Kanyuck KM, DeGrasse SL. First Report of a Direct Surface Plasmon Resonance Immunosensor for a Small Molecule Seafood Toxin. Anal Chem 2014; 86:9251-5. [DOI: 10.1021/ac502271y] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Affiliation(s)
- Betsy Jean Yakes
- U.S. Food and Drug Administration, Center for
Food Safety and Applied Nutrition, 5100 Paint Branch Parkway, College Park, Maryland 20740, United States
| | - Kelsey M. Kanyuck
- Joint
Institute for Food Safety and Applied Nutrition (JIFSAN), University of Maryland, College Park, Maryland 20742, United States
| | - Stacey L. DeGrasse
- U.S. Food and Drug Administration, Center for
Food Safety and Applied Nutrition, 5100 Paint Branch Parkway, College Park, Maryland 20740, United States
| |
Collapse
|
9
|
Tekin HC, Gijs MAM. Ultrasensitive protein detection: a case for microfluidic magnetic bead-based assays. LAB ON A CHIP 2013; 13:4711-39. [PMID: 24145920 DOI: 10.1039/c3lc50477h] [Citation(s) in RCA: 104] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
We review the use of magnetic micro- and nanoparticles ('magnetic beads') in microfluidic systems for ultrasensitive protein detection. During recent years magnetic beads have been used frequently in immunoassays, either as mobile substrates on which the target antigen is captured, as detection labels, or simultaneously as substrates and labels. The major part of the reviewed work has as application the detection of antibodies or disease biomarkers in serum or of biotoxins from food samples. Several of the most sensitive assays allow protein detection down to fg mL(-1) concentrations. We benchmark the performance of these microfluidic magnetic bead-based assays with the most promising earlier work and with alternative solutions.
Collapse
Affiliation(s)
- H Cumhur Tekin
- Laboratory of Microsystems, Ecole Polytechnique Fédérale de Lausanne (EPFL), CH-1015, Lausanne, Switzerland.
| | | |
Collapse
|
10
|
Yakes BJ, Deeds J, White K, Degrasse SL. Evaluation of surface plasmon resonance biosensors for detection of tetrodotoxin in food matrices and comparison to analytical methods. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY 2011; 59:839-46. [PMID: 21192708 DOI: 10.1021/jf103779k] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Tetrodotoxin (TTX) is a low molecular weight neurotoxin found in a number of animal species, including pufferfish. One emerging method for TTX detection employs surface plasmon resonance (SPR) immunosensors. SPR, an optical technique that allows for label-free, real-time, multiplexed analysis, can have detection limits that rival many of the conventional transduction methods. Preliminary SPR approaches for TTX were successful, yet suffered from low throughput and used noncommercial instrumentation. To advance this method for broader use, the immunoassay was transferred to a commercial instrument and optimized for improved detection. This manuscript outlines the assay development and results for complex matrices relevant to seafood safety (pufferfish) and food adulteration (milk, apple juice). In addition, results are compared to those obtained using receptor binding assay, ELISA, HPLC-FD, and LC/MS/MS detection techniques. Results highlight the advantages of SPR assays, including rapid screening capability with low reagent consumption and low- to subppb detection limits.
Collapse
Affiliation(s)
- Betsy Jean Yakes
- Center for Food Safety and Applied Nutrition, U.S. Food and Drug Administration, College Park, Maryland 20740, USA.
| | | | | | | |
Collapse
|