1
|
Mao Y, Patel AA, Meade S, Benzel E, Steinmetz MP, Mroz T, Habboub G. Review of mechanisms of expandable spine surgery devices. Expert Rev Med Devices 2024; 21:381-390. [PMID: 38557229 DOI: 10.1080/17434440.2024.2337295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Accepted: 03/27/2024] [Indexed: 04/04/2024]
Abstract
INTRODUCTION Expandable devices such as interbody cages, vertebral body reconstruction cages, and intravertebral body expansion devices are frequently utilized in spine surgery. Since the introduction of expandable implants in the early 2000s, the variety of mechanisms that drive expansion and implant materials have steadily increased. By examining expandable devices that have achieved commercial success and exploring emerging innovations, we aim to offer an in-depth evaluation of the different types of expandable cages used in spine surgery and the underlying mechanisms that drive their functionality. AREAS COVERED We performed a review of expandable spinal implants and devices by querying the National Library of Medicine MEDLINE database and Google Patents database from 1933 to 2024. Five major types of mechanical jacks that drive expansion were identified: scissor, pneumatic, screw, ratchet, and insertion-expansion. EXPERT OPINION We identified a trend of screw jack mechanism being the predominant machinery in vertebral body reconstruction cages and scissor jack mechanism predominating in interbody cages. Pneumatic jacks were most commonly found in kyphoplasty devices. Critically reviewing the mechanisms of expansion and identifying trends among effective and successful cages allows both surgeons and medical device companies to properly identify future areas of development.
Collapse
Affiliation(s)
- Yuncong Mao
- Center for Spine Health, Cleveland Clinic Foundation, Cleveland Clinic Lerner College of Medicine, Cleveland, OH, USA
| | - Arpan A Patel
- Department of Neurosurgery, Cleveland Clinic Foundation, Cleveland Clinic Lerner College of Medicine, Cleveland, OH, USA
| | - Seth Meade
- Case Western Reserve University School of Medicine, Cleveland, OH, USA
| | - Edward Benzel
- Center for Spine Health, Cleveland Clinic Foundation, Cleveland Clinic Lerner College of Medicine, Cleveland, OH, USA
- Department of Neurosurgery, Cleveland Clinic Foundation, Cleveland Clinic Lerner College of Medicine, Cleveland, OH, USA
| | - Michael P Steinmetz
- Center for Spine Health, Cleveland Clinic Foundation, Cleveland Clinic Lerner College of Medicine, Cleveland, OH, USA
- Department of Neurosurgery, Cleveland Clinic Foundation, Cleveland Clinic Lerner College of Medicine, Cleveland, OH, USA
| | - Thomas Mroz
- Center for Spine Health, Cleveland Clinic Foundation, Cleveland Clinic Lerner College of Medicine, Cleveland, OH, USA
- Department of Neurosurgery, Cleveland Clinic Foundation, Cleveland Clinic Lerner College of Medicine, Cleveland, OH, USA
| | - Ghaith Habboub
- Center for Spine Health, Cleveland Clinic Foundation, Cleveland Clinic Lerner College of Medicine, Cleveland, OH, USA
- Department of Neurosurgery, Cleveland Clinic Foundation, Cleveland Clinic Lerner College of Medicine, Cleveland, OH, USA
| |
Collapse
|
2
|
Begagić E, Pugonja R, Bečulić H, Selimović E, Skomorac R, Saß B, Pojskić M. The New Era of Spinal Surgery: Exploring the Use of Exoscopes as a Viable Alternative to Operative Microscopes-A Systematic Review and Meta-Analysis. World Neurosurg 2024; 182:144-158.e1. [PMID: 37951465 DOI: 10.1016/j.wneu.2023.11.026] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 11/04/2023] [Accepted: 11/06/2023] [Indexed: 11/14/2023]
Abstract
BACKGROUND The growing interest in exoscopic (EX) technology has prompted a comprehensive evaluation of its clinical, functional, and financial outcomes in neurosurgery. This systematic review and meta-analysis aimed to explore the utilization of EX in spine surgery and assess their safety, efficacy, and impact on surgical outcomes. METHODS A thorough literature review was conducted using PubMed, Scopus, and Embase databases in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The study focused on articles concerning the application of EXs in spinal surgical procedures. The inclusion criteria encompassed various study designs presenting clinical data and intraoperative experiences related to EX utilization in spine surgery. RESULTS The meta-analysis included studies examining various aspects of EX utilization, such as intraoperative complications, video/image quality, surgical field visualization, ease of manipulation, ergonomic characteristics, educational utility, surgical duration, and team involvement. Findings indicated that EXs offered superior video quality and favorable ergonomic features. Comparable outcomes were observed in surgical duration, intraoperative blood loss, time to discharge, and postoperative pain levels between EX and conventional microscope approaches. CONCLUSIONS This study provides valuable insights into the utilization of EXs in spine surgery, demonstrating their potential advantages and comparable outcomes with conventional microscopes.
Collapse
Affiliation(s)
- Emir Begagić
- Department of General Medicine, School of Medicine, University of Zenica, Zenica, Bosnia and Herzegovina.
| | - Ragib Pugonja
- Department of General Medicine, School of Medicine, University of Zenica, Zenica, Bosnia and Herzegovina; Department of Anatomy, School of Medicine, University of Zenica, Zenica, Bosnia and Herzegovina
| | - Hakija Bečulić
- Department of Anatomy, School of Medicine, University of Zenica, Zenica, Bosnia and Herzegovina; Department of Neurosurgery, Canton Hospital Zenica, Zenica, Bosnia and Herzegovina
| | - Edin Selimović
- Department of Surgery, School of Medicine, University of Zenica, Zenica, Bosnia and Herzegovina
| | - Rasim Skomorac
- Department of Neurosurgery, Canton Hospital Zenica, Zenica, Bosnia and Herzegovina; Department of Surgery, School of Medicine, University of Zenica, Zenica, Bosnia and Herzegovina
| | - Benjamin Saß
- Clinic of Neurosurgery, University of Marburg, Marburg, Germany
| | - Mirza Pojskić
- Clinic of Neurosurgery, University of Marburg, Marburg, Germany
| |
Collapse
|
3
|
Darwich A, Vogel J, Dally FJ, Hetjens S, Gravius S, Faymonville C, Bludau F. Cervical vertebral body replacement using a modern in situ expandable and angulable corpectomy cage system: early clinical and radiological outcome. Br J Neurosurg 2023; 37:1101-1111. [PMID: 35361031 DOI: 10.1080/02688697.2022.2054946] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Accepted: 03/13/2022] [Indexed: 11/17/2022]
Abstract
PURPOSE Vertebral body replacement (VBR) cages are commonly implanted to reconstruct the cervical vertebrae in cases of tumour, trauma, spondylodiscitis, and degeneration. Expandable cages have been widely used for this purpose; however, the lacking congruence at the implant-bone interface and consequent implant displacement were considered as a serious drawback of such systems. Aim of this study is to evaluate the early clinical and radiological outcome of a modern in situ not only expandable but also angulable cervical corpectomy cage system. METHODS A total of 42 patients who underwent a single or multilevel cervical VBR procedure were included and retrospectively evaluated in this single-centre case series. The neurological status was assessed using American Spinal Injury Association (ASIA) score. Complications were categorized into surgical (including implant-associated) and general medical. Radiographic parameters included regional angulation, segmental height, and coronal alignment. RESULTS Mean age was 59.5 ± 20.6 years. The recorded ASIA score improved postoperatively by 10 points (p 0.0001). Surgical including implant-associated complication rates were 19.05%. Radiographic evaluation showed a height gain of 11.2 mm (p < 0.0001), lordotic correction of 7° (p < 0.0001), and coronal alignment of 3° (p < 0.0001). At the last follow-up, loss of angulation correction of 1.9° (p 0.0002), subsidence of 1.92 mm (p 0.0006), and fusion rates of 68.42% were observed. CONCLUSIONS The use of an in situ angulable and expandable cage system in cervical VBR seems to offer better results compared to conventional static or expandable cages regarding segmental height gain, lordotic correction, and clinical improvement as well as low complication and revision rates. Significant height gain in multilevel surgeries is associated with higher rates of implant-associated complications.
Collapse
Affiliation(s)
- Ali Darwich
- Department of Orthopedic and Trauma Surgery, University Medical Centre Mannheim, Medical Faculty Mannheim of the University of Heidelberg, Mannheim, Germany
| | - Johannes Vogel
- Department of Orthopedic and Trauma Surgery, University Medical Centre Mannheim, Medical Faculty Mannheim of the University of Heidelberg, Mannheim, Germany
| | - Franz-Joseph Dally
- Department of Orthopedic and Trauma Surgery, University Medical Centre Mannheim, Medical Faculty Mannheim of the University of Heidelberg, Mannheim, Germany
| | - Svetlana Hetjens
- Institute of medical statistics and biomathematics, University Medical Centre, Medical Faculty Mannheim of the University of Heidelberg, Mannheim, Germany
| | - Sascha Gravius
- Department of Orthopedic and Trauma Surgery, University Medical Centre Mannheim, Medical Faculty Mannheim of the University of Heidelberg, Mannheim, Germany
| | - Christoph Faymonville
- Department of Orthopedic and Trauma Surgery, University Medical Centre Mannheim, Medical Faculty Mannheim of the University of Heidelberg, Mannheim, Germany
| | - Frederic Bludau
- Department of Orthopedic and Trauma Surgery, University Medical Centre Mannheim, Medical Faculty Mannheim of the University of Heidelberg, Mannheim, Germany
| |
Collapse
|
4
|
Byvaltsev VA, Kalinin AA, Belykh EG, Aliyev MA, Sanzhin BB, Kukharev AV, Dyussembekov YK, Shepelev VV, Riew KD. Clinical and radiological outcomes of one-level cervical corpectomy with an expandable cage for three-column uncomplicated subaxial type «B» injures: a multicenter retrospective study. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2023; 32:1644-1654. [PMID: 36976341 DOI: 10.1007/s00586-023-07648-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 03/01/2023] [Accepted: 03/09/2023] [Indexed: 03/29/2023]
Abstract
PURPOSE To evaluate the clinical and radiological results of the operative management of three-column uncomplicated type «B» subaxial injures treated with a one-level cervical corpectomy with an expandable cage. METHODS This study included 72 patients with a three-column uncomplicated type «B» subaxial injures who met the inclusion criteria, underwent a one-level cervical corpectomy with an expandable cage at one of three neurosurgical departments between 2005 and 2020, and were followed up for clinical and radiological outcomes at a minimum 3-yr follow-up. RESULTS There was a decrease in the VAS pain score from an average of 80 mm to 7 mm (p = 0.03); a decrease in the average NDI score from 62 to 14% (p = 0.01); excellent and good outcomes according to Macnab's scale were 93% (n = 67/72). There was an average change in the cervical lordosis (Cobb method) from -9.10 to -15.40 (p = 0.007), without significant loss of lordosis (p = 0.27). There was no significant degeneration of the adjacent levels by 3 years post-op. The fusion rate, using the Cervical Spine Research Society criteria, was poor: it was 62.5% (n = 45/72), and using the CT criteria, it was 65.3% (n = 47/72). 15.4% patients (n = 11/72) suffered complications. Statistical difference between the fusion and pseudoarthrosis (according to X-ray criteria) subgroups showed that there were no statistically significant differences in the smoking status, diabetes, chronic steroid use, cervical injury level, subtypes of AO type B subaxial injuries and types of expandable cage systems. CONCLUSIONS One-level cervical corpectomy with an expandable cage, despite a poor fusion rate, can be considered a feasible and relatively safe method for treating three-column uncomplicated subaxial type «B» injures, with the benefit of immediate stability, anatomical reduction, and direct decompression of the spinal cord. While no one in our series had any catastrophic complications, we did note a high complication rate.
Collapse
Affiliation(s)
- Vadim A Byvaltsev
- Department of Neurosurgery, Irkutsk State Medical University, Irkutsk, Russia.
- Department of Neurosurgery, Railway Clinical Hospital, Irkutsk, Russia.
- Department of Traumatology, Orthopedic and Neurosurgery, Irkutsk State Medical Academy of Postgraduate Education, Irkutsk, Russia.
| | - Andrei A Kalinin
- Department of Neurosurgery, Irkutsk State Medical University, Irkutsk, Russia
- Department of Neurosurgery, Railway Clinical Hospital, Irkutsk, Russia
| | - Evgenii G Belykh
- Department of Neurosurgery, New Jersey Medical School, Rutgers University, New York, USA
| | - Marat A Aliyev
- Asfendiyarov Kazakh National Medical University, Almaty, Kazakhstan
- Department of Neurosurgery, City Clinical Hospital No. 7, Almaty, Kazakhstan
| | - Bair B Sanzhin
- Department of Neurosurgery, Irkutsk State Medical University, Irkutsk, Russia
| | | | | | - Valerii V Shepelev
- Department of Neurosurgery, Irkutsk State Medical University, Irkutsk, Russia
- Department of Neurosurgery, 1477 Clinical Hospital, Vladivostok, Russia
| | - K Daniel Riew
- Department of Orthopedic Surgery, Columbia University, New York, NY, USA
- Department of Neurological Surgery, Weill Cornell Medical School, New York, USA
| |
Collapse
|
5
|
Seervi MK, Jain S, Purohit DK, Meena US. Evaluation of Radiological and Neurological Outcomes after Anterior Cervical Corpectomy with Fusion using Expandable Cage Alone and Expandable Cage with Anterior Cervical Plating. Asian J Neurosurg 2023; 18:91-100. [PMID: 37056906 PMCID: PMC10089757 DOI: 10.1055/s-0043-1761238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023] Open
Abstract
Abstract
Objective After anterior cervical corpectomy expandable cage were used with or without using anterior cervical plate for structural support are being preferred over autologous bone graft and other types of cages. Nowadays, the preferable type of cages and application of anterior cervical plate remain a debatable topic with studies giving divergent results. The purpose of this study is to evaluate the outcomes of expandable cages used alone or expandable cage used with anterior cervical plate following anterior cervical corpectomy.
Materials and Methods This study was conducted on 100 patients from January 2019 to December 2021 and all patients were undergone anterior cervical corpectomy and fusion and divided in two groups with expandable cage only (Group A) and expandable cage with anterior cervical plate (Group B). Various long-term benefits and radiological outcomes were studied in both groups.
Statistical Analysis and Results In this study, 100 patients were included and all patients underwent corpectomy followed by insertion of expandable cage alone or with anterior cervical plate. There was an improvement in C2–C7 Cobb's angle in group B was significantly higher than group A (p < 0.05) and decrease in Nurick's scale score in group B was significantly higher than group A (p < 0.05). The outcomes were measured with fusion rate (94%), subsidence rate (15%) and change in C2–C7 Cobb's angle was 4 degrees in this study.
Conclusion Expandable cage with or without anterior cervical plate was used after anterior cervical corpectomy for various cervical pathological conditions. In this study, we conclude the long-term benefits and radiological outcomes of two groups as expandable cage was used alone or with additional application of anterior cervical plate. In this study, the results were more in favor of additional application of anterior cervical plate as compared with expandable cage alone and more studies were required in future for more established long-term benefits and drawbacks.
Collapse
|
6
|
Efficacy of NHP66 Bioactive Cage on Patients with Cervical Spine Injury in Short-Track Speed Skating. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2022; 2022:6088398. [PMID: 35132331 PMCID: PMC8817875 DOI: 10.1155/2022/6088398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/03/2021] [Accepted: 12/09/2021] [Indexed: 11/17/2022]
Abstract
Background Short-track speed skating (STSS) is an extreme sport in pursuit of extreme speed and explosive force. In such a sport, once athletes fall down, they are susceptible to serious cervical spine injury (CSI) under the inertia of high-velocity movement. Nanohydroxyapatite/polyamide 66 (NHP66) bioactive cage is a high-tech product of nanotechnology in the medical field in recent years. With a structure similar to that of human cortical bone, NHP66 bioactive cage has extremely high toughness and strength, which tailors to the needs of STSS. Objective This study mainly analyzed the therapeutic effect of NHP66 on patients with CSI in STSS, aiming to provide new opportunities for the treatment of this patient population. Methods A total of 51 patients with CSI treated in our hospital were enrolled, including 19 cases of short-track speed skaters (observation group) and 32 cases of car accidents, falls from heights, or collision injuries (control group). The relevant surgical indicators (operation time, intraoperative blood loss, etc.), the incidence of adverse reactions, the Cobb angle of cervical lordosis before and after surgery, and the fusion segment height of the cage were observed and compared between the two groups. Postoperative pain was evaluated by the visual analog scale (VAS), improvement of spinal cord injury was assessed by the American Spinal Cord Injury Association (ASIA) Impairment Scale, and bone fusion, bone subsidence, and other motor functions were assessed by the Japanese Orthopaedic Association (JOA) score rating system. Results The operation time, intraoperative blood loss, and incidence of adverse reactions in the observation group were significantly lower than those in the control group. The Cobb angle of cervical lordosis and the fusion segment height of cage increased significantly higher in both groups after surgery. In addition, the VAS scores of the observation group 2 h and 3 d after operation were significantly lower than those of the control group. In terms of improvement of spinal cord injury, ASIA and JOA scores in the observation group were significantly higher than those before treatment and in the control group. There was no significant difference in bone fusion activity between the two groups. Conclusions In this study, it is found through experiments that NHP66 has higher safety and application value than autogenous iliac bone, confirming that NHP66 can achieve significant results as a cage for anterior cervical decompression and iliac bone graft fusion and internal fixation in short-track speed skaters after CSI.
Collapse
|