1
|
Moreta J, Gayoso Ó, Donaire-Hoyas D, Roces-García J, Gómez-Vallejo J, Moya-Gómez E, Raya-Roldán D, Albert-Ullibarri A, Marqués-López F, Albareda J. Orthopedic Surgeons' Accuracy When Orienting an Acetabular Cup. A Comparison with Untrained Individuals. MEDICINA (KAUNAS, LITHUANIA) 2022; 58:973. [PMID: 35888692 PMCID: PMC9317603 DOI: 10.3390/medicina58070973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 06/29/2022] [Accepted: 07/18/2022] [Indexed: 12/04/2022]
Abstract
Background and Objectives: Previous studies demonstrated a huge variability among surgeons when it comes to reproducing the position of an acetabular cup in total hip arthroplasty. Our main objective is to determine if orthopedic surgeons can replicate a given orientation on a pelvic model better than untrained individuals. Our secondary objective is to determine if experience has any influence on their ability for this task. Materials and Methods: A group of specialist orthopedic hip surgeons and a group of volunteers with no medical training were asked to reproduce three given (randomly generated) acetabular cup orientations (inclination and anteversion) on a pelvic model. Error was measured by means of a hip navigation system and comparisons between groups were made using the appropriate statistical methods. Results: The study included 107 individuals, 36 orthopedic surgeons and 71 untrained volunteers. The mean error among surgeons was slightly greater as regards both inclination (7.84 ± 5.53 vs. 6.70 ± 4.03) and anteversion (5.85 ± 4.52 vs. 5.48 ± 3.44), although statistical significance was not reached (p = 0.226 and p = 0.639, respectively). Similarly, although surgeons with more than 100 procedures a year obtained better results than those with less surgical experience (8.01 vs. 7.67 degrees of error in inclination and 5.83 vs. 5.87 in anteversion), this difference was not statistically significant, either (p = 0.852 and p = 0.981). Conclusions: No differences were found in the average error made by orthopedic surgeons and untrained individuals. Furthermore, the surgeons' cup orientation accuracy was not seen to improve significantly with experience.
Collapse
Affiliation(s)
- Jesús Moreta
- Department of Orthopedic Surgery and Traumatology, Hospital Galdakao-Usansolo, 48960 Galdakao, Spain
| | - Óscar Gayoso
- Department of Orthopedic Surgery and Traumatology, Hospital San Rafael, 15006 A Coruña, Spain;
| | - Daniel Donaire-Hoyas
- Department of Orthopedic Surgery and Traumatology, Hospital de Poniente, 04700 El Ejido, Spain; (D.D.-H.); (D.R.-R.); (A.A.-U.)
| | - Jorge Roces-García
- Department of Construction and Manufacturing Engineering, Polytechnic School of Engineering of Gijón, University of Oviedo, 33204 Gijón, Spain;
| | - Jesús Gómez-Vallejo
- Department of Orthopedic Surgery and Traumatology, Hospital Clínico Universitario Lozano Blesa, 50009 Zaragoza, Spain; (J.G.-V.); (J.A.)
| | - Esther Moya-Gómez
- Department of Orthopedic Surgery and Traumatology, Hospital de la Santa Cruz y San Pablo, 08025 Barcelona, Spain;
| | - David Raya-Roldán
- Department of Orthopedic Surgery and Traumatology, Hospital de Poniente, 04700 El Ejido, Spain; (D.D.-H.); (D.R.-R.); (A.A.-U.)
| | - Alberto Albert-Ullibarri
- Department of Orthopedic Surgery and Traumatology, Hospital de Poniente, 04700 El Ejido, Spain; (D.D.-H.); (D.R.-R.); (A.A.-U.)
| | - Fernando Marqués-López
- Department of Orthopedic Surgery and Traumatology, Parc de Salut Mar, 08003 Barcelona, Spain;
| | - Jorge Albareda
- Department of Orthopedic Surgery and Traumatology, Hospital Clínico Universitario Lozano Blesa, 50009 Zaragoza, Spain; (J.G.-V.); (J.A.)
| |
Collapse
|