Shen P, An Y, Hao C, Lyu J, Zhao H. Effectiveness and feasibility of 5G-based remote interactive ultrasound training in critical care.
BMC MEDICAL EDUCATION 2024;
24:514. [PMID:
38720299 PMCID:
PMC11080184 DOI:
10.1186/s12909-024-05485-0]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 04/29/2024] [Indexed: 05/12/2024]
Abstract
BACKGROUND
Ultrasound has widely used in various medical fields related to critical care. While online and offline ultrasound trainings are faced by certain challenges, remote ultrasound based on the 5G cloud platform has been gradually adopted in many clinics. However, no study has used the 5G remote ultrasound cloud platform operating system for standardized critical care ultrasound training. This study aimed to evaluate the feasibility and effectiveness of 5G-based remote interactive ultrasound training for standardized diagnosis and treatment in critical care settings.
METHODS
A 5G-based remote interactive ultrasound training system was constructed, and the course was piloted among critical care physicians. From July 2022 to July 2023, 90 critical care physicians from multiple off-site locations were enrolled and randomly divided into experimental and control groups. The 45 physicians in the experimental group were trained using the 5G-based remote interactive ultrasound training system, while the other 45 in the control group were taught using theoretical online videos. The theoretical and practical ultrasonic capabilities of both groups were evaluated before and after the training sessions, and their levels of satisfaction with the training were assessed as well.
RESULTS
The total assessment scores for all of the physicians were markedly higher following the training (80.7 ± 11.9) compared to before (42.1 ± 13.4) by a statistically significant margin (P < 0.001). Before participating in the training, the experimental group scored 42.2 ± 12.5 in the critical care ultrasound competency, and the control group scored 41.9 ± 14.3-indicating no significant differences in their assessment scores (P = 0.907). After participating in the training, the experimental group's assessment scores were 88.4 ± 6.7, which were significantly higher than those of the control group (72.9 ± 10.8; P < 0.001). The satisfaction score of the experimental group was 42.6 ± 2.3, which was also significantly higher than that of the control group (34.7 ± 3.1, P < 0.001).
CONCLUSION
The 5G-based remote interactive ultrasound training system was well-received and effective for critical care. These findings warrant its further promotion and application.
Collapse