1
|
Jiang N, Zhang C, Li M, Li S, Hao Z, Li Z, Wu Z, Li C. The Fabrication of Amino Acid Incorporated Nanoflowers with Intrinsic Peroxidase-like Activity and Its Application for Efficiently Determining Glutathione with TMB Radical Cation as Indicator. MICROMACHINES 2021; 12:mi12091099. [PMID: 34577742 PMCID: PMC8467630 DOI: 10.3390/mi12091099] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 09/08/2021] [Accepted: 09/10/2021] [Indexed: 12/30/2022]
Abstract
The assessment of glutathione (GSH) levels is associated with early diagnostics and pathological analysis for various disorders. Among all kinds of techniques for detecting GSH, the colorimetric assay relying on the oxidation of 3,3′,5,5′-tetramethylbenzidine (TMB) catalyzed by many nanomaterials with peroxidase-like activity attracts increasing attention owing to its outstanding merits, such as high sensitivity and high selectivity. However, the aggregation between the nanomaterials severely hinders the entrance of TMB into the “active site” of these peroxidase mimics. To address this problem, the D-amino acid incorporated nanoflowers possessing peroxidase-like activity with a diameter of 10–15 μm, TMB and H2O2 were employed to establish the detection system for determining the level of glutathione. The larger diameter size of the hybrid nanoflowers substantially averts the aggregation between them. The results confirm that the hybrid nanoflowers detection system presents a low limit of detection, wide linear range, perfect selectivity, good storage stability and desired operational stability for the detection of GSH relying on the intrinsic peroxidase-like activity and favorable mechanical stability of the hybrid nanoflowers, indicating that the hybrid nanoflowers detection system has tremendous application potential in clinical diagnosis and treatment.
Collapse
Affiliation(s)
- Ning Jiang
- Key Laboratory of Zoonosis Research, Ministry of Education, Institute of Zoonosis, College of Veterinary Medicine, Jilin University, Changchun 130062, China; (N.J.); (Z.H.)
- Key Laboratory for Molecular Enzymology and Engineering of the Ministry of Education, College of Life Sciences, Jilin University, Changchun 130012, China; (C.Z.); (S.L.); (Z.L.)
| | - Chuang Zhang
- Key Laboratory for Molecular Enzymology and Engineering of the Ministry of Education, College of Life Sciences, Jilin University, Changchun 130012, China; (C.Z.); (S.L.); (Z.L.)
| | - Meng Li
- State Key Laboratory of Supramolecular Structure and Materials, College of Chemistry, Jilin University, Changchun 130012, China;
| | - Shuai Li
- Key Laboratory for Molecular Enzymology and Engineering of the Ministry of Education, College of Life Sciences, Jilin University, Changchun 130012, China; (C.Z.); (S.L.); (Z.L.)
| | - Zhili Hao
- Key Laboratory of Zoonosis Research, Ministry of Education, Institute of Zoonosis, College of Veterinary Medicine, Jilin University, Changchun 130062, China; (N.J.); (Z.H.)
| | - Zhengqiang Li
- Key Laboratory for Molecular Enzymology and Engineering of the Ministry of Education, College of Life Sciences, Jilin University, Changchun 130012, China; (C.Z.); (S.L.); (Z.L.)
| | - Zhuofu Wu
- Key Laboratory of Straw Biology and Utilization, The Ministry of Education, College of Life Science, Jilin Agricultural University, Changchun 130118, China
- Correspondence: (Z.W.); (C.L.); Tel.: +86-431-84532857 (Z.W.); +86-431-87836710 (C.L.)
| | - Chen Li
- Key Laboratory of Zoonosis Research, Ministry of Education, Institute of Zoonosis, College of Veterinary Medicine, Jilin University, Changchun 130062, China; (N.J.); (Z.H.)
- Correspondence: (Z.W.); (C.L.); Tel.: +86-431-84532857 (Z.W.); +86-431-87836710 (C.L.)
| |
Collapse
|
2
|
Shanko ES, Ceelen L, Wang Y, van de Burgt Y, den Toonder J. Enhanced Microfluidic Sample Homogeneity and Improved Antibody-Based Assay Kinetics Due to Magnetic Mixing. ACS Sens 2021; 6:2553-2562. [PMID: 34191498 PMCID: PMC8457298 DOI: 10.1021/acssensors.1c00050] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
![]()
Recent global events have distinctly demonstrated the need for fast diagnostic analysis
of targets in a liquid sample. However, microfluidic lab-on-a-chip devices for
point-of-care diagnostics can suffer from slow analysis due to poor mixing. Here, we
experimentally explore the mixing effect within a microfluidic chamber, as obtained from
superparamagnetic beads exposed to an out-of-plane (vertical) rotating magnetic field.
Various magnetic protocols are explored, and the level of sample homogeneity is measured
by determining the mixing efficiency index. In particular, we introduce a method to
induce effective mixing in a microfluidic chamber by the actuation of the same beads to
perform global swarming behavior, a collective motion of a large number of individual
entities often seen in nature. The microparticle swarming induces high fluid velocities
in initially stagnant fluids, and it can be externally controlled. The method is
pilot-tested using a point-of-care test featuring a bioluminescent assay for the
detection of antibodies. The mixing by the magnetic beads leads to increased assay
kinetics, which indeed reduces the time to sensor readout substantially. Magnetic
microparticle swarming is expected to be beneficial for a wide variety of point-of-care
devices, where fast homogeneity of reagents does play a role.
Collapse
Affiliation(s)
- Eriola-Sophia Shanko
- Microsystems Research Section, Department of Mechanical Engineering, and Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, P.O. Box 513, Eindhoven 5600MB, The Netherlands
| | - Lennard Ceelen
- Microsystems Research Section, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven 5600MB, The Netherlands
| | - Ye Wang
- Microsystems Research Section, Department of Mechanical Engineering, and Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, P.O. Box 513, Eindhoven 5600MB, The Netherlands
| | - Yoeri van de Burgt
- Microsystems Research Section, Department of Mechanical Engineering, and Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, P.O. Box 513, Eindhoven 5600MB, The Netherlands
| | - Jaap den Toonder
- Microsystems Research Section, Department of Mechanical Engineering, and Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, P.O. Box 513, Eindhoven 5600MB, The Netherlands
| |
Collapse
|