1
|
Ngum LF, Matsushita Y, El-Mashtoly SF, Fath El-Bab AMR, Abdel-Mawgood AL. Separation of microalgae from bacterial contaminants using spiral microchannel in the presence of a chemoattractant. BIORESOUR BIOPROCESS 2024; 11:36. [PMID: 38647805 PMCID: PMC11016047 DOI: 10.1186/s40643-024-00746-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Accepted: 02/29/2024] [Indexed: 04/25/2024] Open
Abstract
Cell separation using microfluidics has become an effective method to isolate biological contaminants from bodily fluids and cell cultures, such as isolating bacteria contaminants from microalgae cultures and isolating bacteria contaminants from white blood cells. In this study, bacterial cells were used as a model contaminant in microalgae culture in a passive microfluidics device, which relies on hydrodynamic forces to demonstrate the separation of microalgae from bacteria contaminants in U and W-shaped cross-section spiral microchannel fabricated by defocusing CO2 laser ablation. At a flow rate of 0.7 ml/min in the presence of glycine as bacteria chemoattractant, the spiral microfluidics devices with U and W-shaped cross-sections were able to isolate microalgae (Desmodesmus sp.) from bacteria (E. coli) with a high separation efficiency of 92% and 96% respectively. At the same flow rate, in the absence of glycine, the separation efficiency of microalgae for U- and W-shaped cross-sections was 91% and 96%, respectively. It was found that the spiral microchannel device with a W-shaped cross-section with a barrier in the center of the channel showed significantly higher separation efficiency. Spiral microchannel chips with U- or W-shaped cross-sections were easy to fabricate and exhibited high throughput. With these advantages, these devices could be widely applicable to other cell separation applications, such as separating circulating tumor cells from blood.
Collapse
Affiliation(s)
- Leticia F Ngum
- Institute of Basic and Applied Sciences, Biotechnology Program, Egypt-Japan University of Science and Technology, Alexandria, 21934, Egypt
| | - Y Matsushita
- Institute of Basic and Applied Sciences, Nanoscience Program, Egypt-Japan University of Science and Technology, Alexandria, 21934, Egypt
| | - Samir F El-Mashtoly
- Institute of Basic and Applied Sciences, Biotechnology Program, Egypt-Japan University of Science and Technology, Alexandria, 21934, Egypt
| | - Ahmed M R Fath El-Bab
- Mechatronics and Robotics Engineering Department, Egypt-Japan University of Science and Technology, Alexandria, 21934, Egypt
| | - Ahmed L Abdel-Mawgood
- Institute of Basic and Applied Sciences, Biotechnology Program, Egypt-Japan University of Science and Technology, Alexandria, 21934, Egypt.
| |
Collapse
|
2
|
Zhang T, Di Carlo D, Lim CT, Zhou T, Tian G, Tang T, Shen AQ, Li W, Li M, Yang Y, Goda K, Yan R, Lei C, Hosokawa Y, Yalikun Y. Passive microfluidic devices for cell separation. Biotechnol Adv 2024; 71:108317. [PMID: 38220118 DOI: 10.1016/j.biotechadv.2024.108317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 12/27/2023] [Accepted: 01/06/2024] [Indexed: 01/16/2024]
Abstract
The separation of specific cell populations is instrumental in gaining insights into cellular processes, elucidating disease mechanisms, and advancing applications in tissue engineering, regenerative medicine, diagnostics, and cell therapies. Microfluidic methods for cell separation have propelled the field forward, benefitting from miniaturization, advanced fabrication technologies, a profound understanding of fluid dynamics governing particle separation mechanisms, and a surge in interdisciplinary investigations focused on diverse applications. Cell separation methodologies can be categorized according to their underlying separation mechanisms. Passive microfluidic separation systems rely on channel structures and fluidic rheology, obviating the necessity for external force fields to facilitate label-free cell separation. These passive approaches offer a compelling combination of cost-effectiveness and scalability when compared to active methods that depend on external fields to manipulate cells. This review delves into the extensive utilization of passive microfluidic techniques for cell separation, encompassing various strategies such as filtration, sedimentation, adhesion-based techniques, pinched flow fractionation (PFF), deterministic lateral displacement (DLD), inertial microfluidics, hydrophoresis, viscoelastic microfluidics, and hybrid microfluidics. Besides, the review provides an in-depth discussion concerning cell types, separation markers, and the commercialization of these technologies. Subsequently, it outlines the current challenges faced in the field and presents a forward-looking perspective on potential future developments. This work hopes to aid in facilitating the dissemination of knowledge in cell separation, guiding future research, and informing practical applications across diverse scientific disciplines.
Collapse
Affiliation(s)
- Tianlong Zhang
- College of Mechanical Engineering, Jiangsu University of Science and Technology, Zhenjiang 212100, China
| | - Dino Di Carlo
- Department of Bioengineering, University of California, Los Angeles, CA 90095, USA
| | - Chwee Teck Lim
- Department of Biomedical Engineering, National University of Singapore, Singapore 117583, Singapore
| | - Tianyuan Zhou
- College of Mechanical Engineering, Jiangsu University of Science and Technology, Zhenjiang 212100, China
| | - Guizhong Tian
- College of Mechanical Engineering, Jiangsu University of Science and Technology, Zhenjiang 212100, China.
| | - Tao Tang
- Department of Biomedical Engineering, National University of Singapore, Singapore 117583, Singapore
| | - Amy Q Shen
- Micro/Bio/Nanofluidics Unit, Okinawa Institute of Science and Technology Graduate University, Onna-son, Okinawa 904-0495, Japan
| | - Weihua Li
- School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Ming Li
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW 2052, Australia
| | - Yang Yang
- Institute of Deep-Sea Science and Engineering, Chinese Academy of Sciences, Sanya, Hainan 572000, China
| | - Keisuke Goda
- Department of Bioengineering, University of California, Los Angeles, CA 90095, USA; Department of Chemistry, University of Tokyo, Tokyo 113-0033, Japan; The Institute of Technological Sciences, Wuhan University, Wuhan 430072, China
| | - Ruopeng Yan
- The Institute of Technological Sciences, Wuhan University, Wuhan 430072, China
| | - Cheng Lei
- The Institute of Technological Sciences, Wuhan University, Wuhan 430072, China
| | - Yoichiroh Hosokawa
- Division of Materials Science, Nara Institute of Science and Technology, Nara 630-0192, Japan
| | - Yaxiaer Yalikun
- Division of Materials Science, Nara Institute of Science and Technology, Nara 630-0192, Japan.
| |
Collapse
|
3
|
Adel M, Allam A, Sayour AE, Ragai HF, Umezu S, Fath El-Bab AMR. Design and development of a portable low-cost QCM-based system for liquid biosensing. Biomed Microdevices 2024; 26:11. [PMID: 38236465 PMCID: PMC10796497 DOI: 10.1007/s10544-024-00696-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/04/2024] [Indexed: 01/19/2024]
Abstract
Quartz crystal microbalance (QCM) is a versatile sensing platform that has gained increasing attention for its use in bioapplications due to its high sensitivity, real-time measurement capabilities, and label-free detection. This article presents a portable QCM system for liquid biosensing that uses a modified Hartley oscillator to drive 14 mm-diameter commercial QCM sensors. The system is designed to be low-cost, easy to use, and highly sensitive, making it ideal for various bioapplications. A new flow cell design to deliver samples to the surface of the sensor has been designed, fabricated, and tested. For portability and miniaturization purposes, a micropump-based pumping system is used in the current system. The system has a built-in temperature controller allowing for accurate frequency measurements. In addition, the system can be used in benchtop mode. The capability of the present system to be used in liquid biosensing is demonstrated through an experimental test for sensitivity to changes in the viscosity of glycerol samples. It was found to have a sensitivity of 263.51 Hz/mPa.s using a 10 MHz QCM sensor. Future work regarding potential applications was suggested.
Collapse
Affiliation(s)
- Mohamed Adel
- Department of Mechatronics and Robotics Engineering, Egypt-Japan University of Science and Technology (E-JUST), Alexandria, 21934, Egypt.
- Mechanical Engineering Department, Helwan University, Cairo, 11792, Egypt.
| | - Ahmed Allam
- Department of Electronics and Communications Engineering, Egypt-Japan University of Science and Technology (E-JUST), Alexandria, 21934, Egypt
| | - Ashraf E Sayour
- Molecular Biomimetics Research Group, Animal Health Research Institute, Agricultural Research Center, Giza, 12618, Egypt
| | - Hani F Ragai
- Electronics and Communications Department, Faculty of Engineering, Ain Shams University, Cairo, 11517, Egypt
| | - Shinjiro Umezu
- Department of Modern Mechanical Engineering, Waseda University, 3-4-1 Okubo, Shinjuku-Ku, Tokyo, 169-8555, Japan
| | - Ahmed M R Fath El-Bab
- Department of Mechatronics and Robotics Engineering, Egypt-Japan University of Science and Technology (E-JUST), Alexandria, 21934, Egypt
| |
Collapse
|