Julius LA, Torres Delgado SM, Mishra R, Kent N, Carthy E, Korvink JG, Mager D, Ducrée J, Kinahan DJ. Programmable fluidic networks on centrifugal microfluidic discs. Anal Chim Acta 2024; 1288:342159. [PMID: 38220291 DOI: 10.1016/j.aca.2023.342159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 12/08/2023] [Accepted: 12/16/2023] [Indexed: 01/16/2024]
Abstract
BACKGROUND Biomedical diagnostic and lab automation solutions built on the Lab-on-a-Disc (LoaD) platform has great potential due to their independence from specialised micro-pumps and their ease of integration, through direct pipetting, with manual or automated workflows. However, a challenge for all microfluidic chips is their cost of manufacture when each microfluidic disc must be customized for a specific application. In this paper, we present centrifugal discs with programmable fluidic networks. RESULTS Based on dissolvable film valves, we present two technologies. The first, based on recently introduced pulse-actuated dissolvable film valves, is a centrifugal disc which, depending on how it is loaded, is configured to perform either six sequential reagent releases through one reaction chamber or three sequential reagent releases through two reaction chambers. In the second approach, we use the previously introduced electronic Lab-on-a-Disc (eLoaD) wireless valve array, which can actuate up to 128 centrifugo-pneumatic dissolvable film valves in a pre-defined sequence. In this approach we present a disc which can deliver any one of 8 reagent washes to any one of four reaction chambers. We use identical discs to demonstrate the first four sequential washes through two reaction chambers and then two sequential washes through four reaction chambers. SIGNIFICANCE These programmable fluidic networks have the potential to allow a single disc architecture to be applied to multiple different assay types and so can offer a lower-cost and more integrated alternative to the standard combination of micro-titre plate and liquid handling robot. Indeed, it may even be possible to conduct multiple different assays concurrently. This can have the effect of reducing manufacturing costs and streamlining supply-chains and so results in a more accessible diagnostic platform.
Collapse
Affiliation(s)
- Lourdes An Julius
- Fraunhofer Project Center at Dublin City University (FPC@DCU), Dublin City University, Glasnevin, Dublin 9, Ireland; School of Physical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Sarai M Torres Delgado
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Lepolshafen, 76344, Germany
| | - Rohit Mishra
- Fraunhofer Project Center at Dublin City University (FPC@DCU), Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Nigel Kent
- School of Mechanical & Manufacturing Engineering, Dublin City University, Glasnevin, Dublin 9, Ireland; National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin 9, Ireland; Biodesign Europe, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Eadaoin Carthy
- School of Mechanical & Manufacturing Engineering, Dublin City University, Glasnevin, Dublin 9, Ireland; National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin 9, Ireland; Biodesign Europe, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Jan G Korvink
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Lepolshafen, 76344, Germany
| | - Dario Mager
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Lepolshafen, 76344, Germany
| | - Jens Ducrée
- School of Physical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland; National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin 9, Ireland; Biodesign Europe, Dublin City University, Glasnevin, Dublin 9, Ireland
| | - David J Kinahan
- School of Mechanical & Manufacturing Engineering, Dublin City University, Glasnevin, Dublin 9, Ireland; National Centre for Sensor Research, Dublin City University, Glasnevin, Dublin 9, Ireland; Biodesign Europe, Dublin City University, Glasnevin, Dublin 9, Ireland; I-Form, The SFI Research Centre for Advanced Manufacturing, Dublin City University, Dublin 9, Ireland.
| |
Collapse
|
2
|
Carthy É, Hughes B, Higgins E, Early P, Merne C, Walsh D, Parle-McDermott A, Kinahan DJ. Automated solid phase DNA extraction on a lab-on-a-disc with two-degrees of freedom instrumentation. Anal Chim Acta 2023; 1280:341859. [PMID: 37858565 DOI: 10.1016/j.aca.2023.341859] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Revised: 09/15/2023] [Accepted: 09/29/2023] [Indexed: 10/21/2023]
Abstract
BACKGROUND Lab-on-a-disc (LoaD) technology has emerged as a transformative approach for point-of-care diagnostics and high-throughput testing. The promise of integrating multiple laboratory functions onto a single integrated platform has significant implications for healthcare, especially in resource-limited settings. However, one of the primary challenges faced in the design and manufacture of LoaD devices is the integration of effective valving mechanisms. These valves are essential for fluid control and routing, but their intricacy often leads to complexities in design and increased vulnerability to failure. This emphasizes the need for improved designs and manufacturing processes without complex, integrated valving mechanisms. (96) RESULTS: We describe a fully automated biological workflow and reagent actuation on a LoaD device without an integrated valving system. The Two Degrees-of-Freedom (2DoF) custom centrifuge alters the centre of rotation, facilitating fluid flow direction changes on the microfluidic platform through a custom programmed interface. A novel 360-degree fluid manipulation approach via secondary planetary gear motion enabled sequential assay reagent actuation without embedded valve triggering, with the addition of infinite incubation times and efficient use of platform realty. The simplified LoaD platform uses clever design, with intermediate flow chambers to avoid cross contamination between reagent steps. Notably, the optimized LoaD platform demonstrated a two-fold DNA yield at higher HEK-293 cell concentrations compared to commercially available spin-column kits. This significantly simplified LoaD platform successfully automated a common, complex workflow without inhibiting DNA purification. (129) SIGNIFICANCE: This system exhibits the clever coupling of both 2DoF and centrifugal microfluidics to create an autonomous testing package capable of eradicating the need for complex valving systems to automate biological workflows on LoaDs. This automated system has outperformed commercially available DNA extraction kits for higher cell counts. The platform's elimination of valve requirements ensures unlimited sample incubation times and enhances reliability, making it a straightforward option for automated biological workflows, particularly in diagnostics. (73).
Collapse
Affiliation(s)
- Éadaoin Carthy
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland; National Centre for Sensor Research (NCSR), Dublin City University, Dublin, Ireland; Biodesign Europe, Dublin City University, Dublin, Ireland.
| | - Brian Hughes
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland
| | - Eimear Higgins
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland
| | - Phil Early
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland
| | - Cian Merne
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland
| | - Darren Walsh
- School of Biotechnology, Dublin City University, Glasnevin, Dublin, Ireland
| | - Anne Parle-McDermott
- National Centre for Sensor Research (NCSR), Dublin City University, Dublin, Ireland; School of Biotechnology, Dublin City University, Glasnevin, Dublin, Ireland
| | - David J Kinahan
- School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland; National Centre for Sensor Research (NCSR), Dublin City University, Dublin, Ireland; Biodesign Europe, Dublin City University, Dublin, Ireland
| |
Collapse
|
3
|
Mishra R, Julius LA, Condon J, Pavelskopfa P, Early PL, Dorrian M, Mrvova K, Henihan G, Mangwanya F, Dreo T, Ducrée J, Macdonald NP, Schoen C, Kinahan DJ. Plant pathogen detection on a lab-on-a-disc using solid-phase extraction and isothermal nucleic acid amplification enabled by digital pulse-actuated dissolvable film valves. Anal Chim Acta 2023; 1258:341070. [PMID: 37087288 DOI: 10.1016/j.aca.2023.341070] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 03/06/2023] [Accepted: 03/07/2023] [Indexed: 03/21/2023]
Abstract
By virtue of its ruggedness, portability, rapid processing times, and ease-of-use, academic and commercial interest in centrifugal microfluidic systems has soared over the last decade. A key advantage of the LoaD platform is the ability to automate laboratory unit operations (LUOs) (mixing, metering, washing etc.) to support direct translation of 'on-bench' assays to 'on-chip'. Additionally, the LoaD requires just a low-cost spindle motor rather than specialized and expensive microfluidic pumps. Furthermore, when flow control (valves) is implemented through purely rotational changes in this same spindle motor (rather than using additional support instrumentation), the LoaD offers the potential to be a truly portable, low-cost and accessible platform. Current rotationally controlled valves are typically opened by sequentially increasing the disc spin-rate to a specific opening frequency. However, due lack of manufacturing fidelity these specific opening frequencies are better described as spin frequency 'bands'. With low-cost motors typically having a maximum spin-rate of 6000 rpm (100 Hz), using this 'analogue' approach places a limitation on the number of valves, which can be serially actuated thus limiting the number of LUOs that can be automated. In this work, a novel flow control scheme is presented where the sequence of valve actuation is determined by architecture of the disc while its timing is governed by freely programmable 'digital' pulses in its spin profile. This paradigm shift to 'digital' flow control enables automation of multi-step assays with high reliability, with full temporal control, and with the number of LUOs theoretically only limited by available space on the disc. We first describe the operational principle of these valves followed by a demonstration of the capability of these valves to automate complex assays by screening tomato leaf samples against plant pathogens. Reagents and lysed sample are loaded on-disc and then, in a fully autonomous fashion using only spindle-motor control, the complete assay is automated. Amplification and fluorescent acquisition take place on a custom spin-stand enabling the generation of real-time LAMP amplification curves using custom software. To prevent environmental contamination, the entire discs are sealed from atmosphere following loading with internal venting channels permitting easy movement of liquids about the disc. The disc was successfully used to detect the presence of thermally inactivated Clavibacter michiganensis. Michiganensis (CMM) bacterial pathogen on tomato leaf samples.
Collapse
Affiliation(s)
- Rohit Mishra
- Fraunhofer Project Centre at Dublin City University, Dublin City University, Glasnevin, Dublin, Ireland; School of Physical Sciences, Dublin City University, Dublin, Ireland; National Centre for Sensor Research (NCSR), Dublin City University, Dublin, Ireland; Biodesign Europe, Dublin City University, Dublin, Ireland.
| | - Lourdes An Julius
- Fraunhofer Project Centre at Dublin City University, Dublin City University, Glasnevin, Dublin, Ireland
| | - Jack Condon
- Fraunhofer Project Centre at Dublin City University, Dublin City University, Glasnevin, Dublin, Ireland
| | - Patricija Pavelskopfa
- Fraunhofer Project Centre at Dublin City University, Dublin City University, Glasnevin, Dublin, Ireland
| | - Philip L Early
- Fraunhofer Project Centre at Dublin City University, Dublin City University, Glasnevin, Dublin, Ireland; School of Physical Sciences, Dublin City University, Dublin, Ireland; School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland
| | - Matthew Dorrian
- Fraunhofer Project Centre at Dublin City University, Dublin City University, Glasnevin, Dublin, Ireland
| | - Katarina Mrvova
- Fraunhofer Project Centre at Dublin City University, Dublin City University, Glasnevin, Dublin, Ireland
| | - Grace Henihan
- Fraunhofer Project Centre at Dublin City University, Dublin City University, Glasnevin, Dublin, Ireland
| | - Faith Mangwanya
- Fraunhofer Project Centre at Dublin City University, Dublin City University, Glasnevin, Dublin, Ireland
| | - Tanya Dreo
- National Institute of Biology, Ljubljana, Slovenia
| | - Jens Ducrée
- School of Physical Sciences, Dublin City University, Dublin, Ireland
| | - Niall P Macdonald
- Fraunhofer Project Centre at Dublin City University, Dublin City University, Glasnevin, Dublin, Ireland
| | - Cor Schoen
- Wageningen University Research, Wageningen, the Netherlands
| | - David J Kinahan
- Fraunhofer Project Centre at Dublin City University, Dublin City University, Glasnevin, Dublin, Ireland; National Centre for Sensor Research (NCSR), Dublin City University, Dublin, Ireland; Biodesign Europe, Dublin City University, Dublin, Ireland; School of Mechanical and Manufacturing Engineering, Dublin City University, Glasnevin, Dublin, Ireland.
| |
Collapse
|
4
|
A novel method for inward fluid displacement in centrifugal microdevices for highly integrated nucleic acid processing with long-term reagent storage. Anal Chim Acta 2022; 1221:340063. [DOI: 10.1016/j.aca.2022.340063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 05/20/2022] [Accepted: 06/06/2022] [Indexed: 11/18/2022]
|
5
|
Ducrée J. Systematic review of centrifugal valving based on digital twin modeling towards highly integrated lab-on-a-disc systems. MICROSYSTEMS & NANOENGINEERING 2021; 7:104. [PMID: 34987859 PMCID: PMC8677742 DOI: 10.1038/s41378-021-00317-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 09/16/2021] [Accepted: 09/27/2021] [Indexed: 05/07/2023]
Abstract
Current, application-driven trends towards larger-scale integration (LSI) of microfluidic systems for comprehensive assay automation and multiplexing pose significant technological and economical challenges to developers. By virtue of their intrinsic capability for powerful sample preparation, centrifugal systems have attracted significant interest in academia and business since the early 1990s. This review models common, rotationally controlled valving schemes at the heart of such "Lab-on-a-Disc" (LoaD) platforms to predict critical spin rates and reliability of flow control which mainly depend on geometries, location and liquid volumes to be processed, and their experimental tolerances. In absence of larger-scale manufacturing facilities during product development, the method presented here facilitates efficient simulation tools for virtual prototyping and characterization and algorithmic design optimization according to key performance metrics. This virtual in silico approach thus significantly accelerates, de-risks and lowers costs along the critical advancement from idea, layout, fluidic testing, bioanalytical validation, and scale-up to commercial mass manufacture.
Collapse
Affiliation(s)
- Jens Ducrée
- School of Physical Sciences, Dublin City University, Dublin, Ireland
| |
Collapse
|
6
|
Design Optimization of Centrifugal Microfluidic “Lab-on-a-Disc” Systems towards Fluidic Larger-Scale Integration. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11135839] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Enhancing the degree of functional multiplexing while assuring operational reliability and manufacturability at competitive costs are crucial ingredients for enabling comprehensive sample-to-answer automation, e.g., for use in common, decentralized “Point-of-Care” or “Point-of-Use” scenarios. This paper demonstrates a model-based “digital twin” approach, which efficiently supports the algorithmic design optimization of exemplary centrifugo-pneumatic (CP) dissolvable-film (DF) siphon valves toward larger-scale integration (LSI) of well-established “Lab-on-a-Disc” (LoaD) systems. Obviously, the spatial footprint of the valves and their upstream laboratory unit operations (LUOs) have to fit, at a given radial position prescribed by its occurrence in the assay protocol, into the locally accessible disc space. At the same time, the retention rate of a rotationally actuated CP-DF siphon valve and, most challengingly, its band width related to unavoidable tolerances of experimental input parameters need to slot into a defined interval of the practically allowed frequency envelope. To accomplish particular design goals, a set of parametrized metrics is defined, which are to be met within their practical boundaries while (numerically) minimizing the band width in the frequency domain. While each LSI scenario needs to be addressed individually on the basis of the digital twin, a suite of qualitative design rules and instructive showcases structures are presented.
Collapse
|
7
|
Ducrée J. Secure Air Traffic Control at the Hub of Multiplexing on the Centrifugo-Pneumatic Lab-on-a-Disc Platform. MICROMACHINES 2021; 12:700. [PMID: 34203926 PMCID: PMC8232791 DOI: 10.3390/mi12060700] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 06/01/2021] [Accepted: 06/10/2021] [Indexed: 12/14/2022]
Abstract
Fluidic larger-scale integration (LSI) resides at the heart of comprehensive sample-to-answer automation and parallelization of assay panels for frequent and ubiquitous bioanalytical testing in decentralized point-of-use/point-of-care settings. This paper develops a novel "digital twin" strategy with an emphasis on rotational, centrifugo-pneumatic flow control. The underlying model systematically connects retention rates of rotationally actuated valves as a key element of LSI to experimental input parameters; for the first time, the concept of band widths in frequency space as the decisive quantity characterizing operational robustness is introduced, a set of quantitative performance metrics guiding algorithmic optimization of disc layouts is defined, and the engineering principles of advanced, logical flow control and timing are elucidated. Overall, the digital twin enables efficient design for automating multiplexed bioassay protocols on such "Lab-on-a-Disc" (LoaD) systems featuring high packing density, reliability, configurability, modularity, and manufacturability to eventually minimize cost, time, and risk of development and production.
Collapse
Affiliation(s)
- Jens Ducrée
- School of Physical Sciences, Dublin City University, Glasnevin, Dublin 9, Ireland
| |
Collapse
|
8
|
Abstract
Lab-on-a-Disc (LoaD) biosensors are increasingly a promising solution for many biosensing applications. In the search for a perfect match between point-of-care (PoC) microfluidic devices and biosensors, the LoaD platform has the potential to be reliable, sensitive, low-cost, and easy-to-use. The present global pandemic draws attention to the importance of rapid sample-to-answer PoC devices for minimising manual intervention and sample manipulation, thus increasing the safety of the health professional while minimising the chances of sample contamination. A biosensor is defined by its ability to measure an analyte by converting a biological binding event to tangible analytical data. With evolving manufacturing processes for both LoaDs and biosensors, it is becoming more feasible to embed biosensors within the platform and/or to pair the microfluidic cartridges with low-cost detection systems. This review considers the basics of the centrifugal microfluidics and describes recent developments in common biosensing methods and novel technologies for fluidic control and automation. Finally, an overview of current devices on the market is provided. This review will guide scientists who want to initiate research in LoaD PoC devices as well as providing valuable reference material to researchers active in the field.
Collapse
|
9
|
Hess JF, Zehnle S, Juelg P, Hutzenlaub T, Zengerle R, Paust N. Review on pneumatic operations in centrifugal microfluidics. LAB ON A CHIP 2019; 19:3745-3770. [PMID: 31596297 DOI: 10.1039/c9lc00441f] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Centrifugal microfluidics allows for miniaturization, automation and parallelization of laboratory workflows. The fact that centrifugal forces are always directed radially outwards has been considered a main drawback for the implementation of complex workflows leading to the requirement of additional actuation forces for pumping, valving and switching. In this work, we review and discuss the combination of centrifugal with pneumatic forces which enables transport of even complex liquids in any direction on centrifugal systems, provides actuation for valving and switching, offers alternatives for mixing and enables accurate and precise metering and aliquoting. In addition, pneumatics can be employed for timing to carry out any of the above listed unit operations in a sequential and cascaded manner. Firstly, different methods to generate pneumatic pressures are discussed. Then, unit operations and applications that employ pneumatics are reviewed. Finally, a tutorial section discusses two examples to provide insight into the design process. The first tutorial explains a comparatively simple implementation of a pneumatic siphon valve and provides a workflow to derive optimum design parameters. The second tutorial discusses cascaded pneumatic operations consisting of temperature change rate actuated valving and subsequent pneumatic pumping. In conclusion, combining pneumatic actuation with centrifugal microfluidics allows for the design of robust fluidic networks with simple fluidic structures that are implemented in a monolithic fashion. No coatings are required and the overall demands on manufacturing are comparatively low. We see the combination of centrifugal forces with pneumatic actuation as a key enabling technology to facilitate compact and robust automation of biochemical analysis.
Collapse
Affiliation(s)
- J F Hess
- Laboratory for MEMS Applications, Department of Microsystems Engineering - IMTEK, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany
| | - S Zehnle
- Hahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany.
| | - P Juelg
- Hahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany.
| | - T Hutzenlaub
- Laboratory for MEMS Applications, Department of Microsystems Engineering - IMTEK, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany and Hahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany.
| | - R Zengerle
- Laboratory for MEMS Applications, Department of Microsystems Engineering - IMTEK, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany and Hahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany.
| | - N Paust
- Laboratory for MEMS Applications, Department of Microsystems Engineering - IMTEK, University of Freiburg, Georges-Koehler-Allee 103, 79110 Freiburg, Germany and Hahn-Schickard, Georges-Koehler-Allee 103, 79110 Freiburg, Germany.
| |
Collapse
|
10
|
Wu HC, Chen YH, Shih CH. Disk-based enzyme-linked immunosorbent assays using the liquid-aliquoting and siphoning-evacuation technique. BIOMICROFLUIDICS 2018; 12:054101. [PMID: 30271516 PMCID: PMC6136921 DOI: 10.1063/1.5047281] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Accepted: 08/28/2018] [Indexed: 06/08/2023]
Abstract
A cost-effective way to carry out multiple enzyme-linked immunosorbent assays (ELISAs) on a centrifugal platform using the liquid-aliquoting and siphoning-evacuation (LASE) technique was developed in this paper. Instead of preloading all the reagents in the reservoirs before testing, each reagent was loaded only one time during testing. The reagent was distributed into equal aliquots and delivered into reaction chambers by the aliquoting fluidic function. In addition, a siphoning-evacuation technique was developed to improve the washing efficiency and simplify the assay protocol. Furthermore, the entire assay protocol can be conducted using a two-step spinning protocol, which greatly reduces the cost of the motor control system. With the LASE technique, a low-cost and user-friendly ELISA system can be achieved.
Collapse
Affiliation(s)
- Ho-Chin Wu
- Department of Chemical Engineering, Feng Chia University, 40724 Taichung, Taiwan
| | - Yen-Hao Chen
- Department of Chemical Engineering, Feng Chia University, 40724 Taichung, Taiwan
| | - Chih-Hsin Shih
- Department of Chemical Engineering, Feng Chia University, 40724 Taichung, Taiwan
| |
Collapse
|
11
|
Miyazaki CM, Kinahan DJ, Mishra R, Mangwanya F, Kilcawley N, Ferreira M, Ducrée J. Label-free, spatially multiplexed SPR detection of immunoassays on a highly integrated centrifugal Lab-on-a-Disc platform. Biosens Bioelectron 2018; 119:86-93. [PMID: 30103158 DOI: 10.1016/j.bios.2018.07.056] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2018] [Revised: 07/18/2018] [Accepted: 07/27/2018] [Indexed: 02/06/2023]
Abstract
As a direct, label-free method, Surface Plasmon Resonance (SPR) detection significantly reduces the needs for liquid handling and reagent storage compared to common enzyme-linked immunosorbent assays (ELISAs), thus enabling comprehensive multiplexing of bioassays on microfluidic sample-to-answer systems. This paper describes a highly integrated centrifugal Lab-on-a-Disc (LoaD) platform for automating the full process chain extending between plasma extraction and subsequent aliquoting to five parallelized reaction channels for quantitative SPR detection by an inexpensive smartphone camera. The entire, multi-step / multi-reagent operation completes within less than 1 h. While the emphasis of this work is on the fluidic automation and parallelization by previously introduced, very robust event-triggered valving and buoyancy-driven centripetal pumping schemes, we successfully implement an immunoglobulin G (IgG) assay; by specific functionalization of the detection surfaces, the same disc layout can readily be customised for immunoassays panels from whole blood.
Collapse
Affiliation(s)
- Celina M Miyazaki
- FPC@DCU - Fraunhofer Project Centre for Embedded Bioanalytical Systems at Dublin City University, School of Physical Sciences, Dublin City University, Ireland; Federal University of São Carlos, Sorocaba, SP, Brazil.
| | - David J Kinahan
- FPC@DCU - Fraunhofer Project Centre for Embedded Bioanalytical Systems at Dublin City University, School of Physical Sciences, Dublin City University, Ireland
| | - Rohit Mishra
- FPC@DCU - Fraunhofer Project Centre for Embedded Bioanalytical Systems at Dublin City University, School of Physical Sciences, Dublin City University, Ireland
| | - Faith Mangwanya
- FPC@DCU - Fraunhofer Project Centre for Embedded Bioanalytical Systems at Dublin City University, School of Physical Sciences, Dublin City University, Ireland
| | - Niamh Kilcawley
- FPC@DCU - Fraunhofer Project Centre for Embedded Bioanalytical Systems at Dublin City University, School of Physical Sciences, Dublin City University, Ireland
| | | | - Jens Ducrée
- FPC@DCU - Fraunhofer Project Centre for Embedded Bioanalytical Systems at Dublin City University, School of Physical Sciences, Dublin City University, Ireland.
| |
Collapse
|
12
|
Torres Delgado SM, Kinahan DJ, Nirupa Julius LA, Mallette A, Ardila DS, Mishra R, Miyazaki CM, Korvink JG, Ducrée J, Mager D. Wirelessly powered and remotely controlled valve-array for highly multiplexed analytical assay automation on a centrifugal microfluidic platform. Biosens Bioelectron 2018; 109:214-223. [PMID: 29567566 DOI: 10.1016/j.bios.2018.03.012] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Revised: 02/09/2018] [Accepted: 03/06/2018] [Indexed: 12/14/2022]
Abstract
In this paper we present a wirelessly powered array of 128 centrifugo-pneumatic valves that can be thermally actuated on demand during spinning. The valves can either be triggered by a predefined protocol, wireless signal transmission via Bluetooth, or in response to a sensor monitoring a parameter like the temperature, or homogeneity of the dispersion. Upon activation of a resistive heater, a low-melting membrane (Parafilm™) is removed to vent an entrapped gas pocket, thus letting the incoming liquid wet an intermediate dissolvable film and thereby open the valve. The proposed system allows up to 12 heaters to be activated in parallel, with a response time below 3 s, potentially resulting in 128 actuated valves in under 30 s. We demonstrate, with three examples of common and standard procedures, how the proposed technology could become a powerful tool for implementing diagnostic assays on Lab-on-a-Disc. First, we implement wireless actuation of 64 valves during rotation in a freely programmable sequence, or upon user input in real time. Then, we show a closed-loop centrifugal flow control sequence for which the state of mixing of reagents, evaluated from stroboscopically recorded images, triggers the opening of the valves. In our last experiment, valving and closed-loop control are used to facilitate centrifugal processing of whole blood.
Collapse
Affiliation(s)
- Saraí M Torres Delgado
- Laboratory for Simulation, Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges-Koehler-Allee 103, Freiburg im Breisgau 79110, Germany; Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen 76344, Germany
| | - David J Kinahan
- FPC@DCU - Fraunhofer Project Centre for Embedded Bioanalytical Systems at Dublin City University, Glasnevin, Dublin 9, Ireland.
| | - Lourdes Albina Nirupa Julius
- FPC@DCU - Fraunhofer Project Centre for Embedded Bioanalytical Systems at Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Adam Mallette
- FPC@DCU - Fraunhofer Project Centre for Embedded Bioanalytical Systems at Dublin City University, Glasnevin, Dublin 9, Ireland; Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, IN, United States
| | - David Sáenz Ardila
- Laboratory for Simulation, Department of Microsystems Engineering (IMTEK), University of Freiburg, Georges-Koehler-Allee 103, Freiburg im Breisgau 79110, Germany
| | - Rohit Mishra
- FPC@DCU - Fraunhofer Project Centre for Embedded Bioanalytical Systems at Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Celina M Miyazaki
- FPC@DCU - Fraunhofer Project Centre for Embedded Bioanalytical Systems at Dublin City University, Glasnevin, Dublin 9, Ireland; Science and Technology Centre for Sustainability, Federal University of São Carlos, Campus Sorocaba, SP, Brazil
| | - Jan G Korvink
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen 76344, Germany
| | - Jens Ducrée
- FPC@DCU - Fraunhofer Project Centre for Embedded Bioanalytical Systems at Dublin City University, Glasnevin, Dublin 9, Ireland
| | - Dario Mager
- Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen 76344, Germany
| |
Collapse
|
13
|
Oh KW. Multidisciplinary Role of Microfluidics for Biomedical and Diagnostic Applications: Biomedical Microfluidic Devices. MICROMACHINES 2017; 8:E343. [PMID: 30400533 PMCID: PMC6187927 DOI: 10.3390/mi8120343] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 11/24/2017] [Revised: 11/24/2017] [Accepted: 11/24/2017] [Indexed: 12/28/2022]
Abstract
Life scientists are closely working with engineers to solve biological and biomedical problems through the application of engineering tools.[...].
Collapse
Affiliation(s)
- Kwang W Oh
- SMALL (Sensors and MicroActuators Learning Lab), Department of Electrical Engineering & Department of Biomedical Engineering, University at Buffalo, State University of New York (SUNY-Buffalo), Buffalo, NY 14260, USA.
| |
Collapse
|