1
|
Socoliuc V, Avdeev MV, Kuncser V, Turcu R, Tombácz E, Vékás L. Ferrofluids and bio-ferrofluids: looking back and stepping forward. NANOSCALE 2022; 14:4786-4886. [PMID: 35297919 DOI: 10.1039/d1nr05841j] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Ferrofluids investigated along for about five decades are ultrastable colloidal suspensions of magnetic nanoparticles, which manifest simultaneously fluid and magnetic properties. Their magnetically controllable and tunable feature proved to be from the beginning an extremely fertile ground for a wide range of engineering applications. More recently, biocompatible ferrofluids attracted huge interest and produced a considerable increase of the applicative potential in nanomedicine, biotechnology and environmental protection. This paper offers a brief overview of the most relevant early results and a comprehensive description of recent achievements in ferrofluid synthesis, advanced characterization, as well as the governing equations of ferrohydrodynamics, the most important interfacial phenomena and the flow properties. Finally, it provides an overview of recent advances in tunable and adaptive multifunctional materials derived from ferrofluids and a detailed presentation of the recent progress of applications in the field of sensors and actuators, ferrofluid-driven assembly and manipulation, droplet technology, including droplet generation and control, mechanical actuation, liquid computing and robotics.
Collapse
Affiliation(s)
- V Socoliuc
- Romanian Academy - Timisoara Branch, Center for Fundamental and Advanced Technical Research, Laboratory of Magnetic Fluids, Mihai Viteazu Ave. 24, 300223 Timisoara, Romania.
| | - M V Avdeev
- Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, Joliot-Curie Str. 6, 141980 Dubna, Moscow Reg., Russia.
| | - V Kuncser
- National Institute of Materials Physics, Bucharest-Magurele, 077125, Romania
| | - Rodica Turcu
- National Institute for Research and Development of Isotopic and Molecular Technologies (INCDTIM), Donat Str. 67-103, 400293 Cluj-Napoca, Romania
| | - Etelka Tombácz
- University of Szeged, Faculty of Engineering, Department of Food Engineering, Moszkvai krt. 5-7, H-6725 Szeged, Hungary.
- University of Pannonia - Soós Ernő Water Technology Research and Development Center, H-8800 Zrínyi M. str. 18, Nagykanizsa, Hungary
| | - L Vékás
- Romanian Academy - Timisoara Branch, Center for Fundamental and Advanced Technical Research, Laboratory of Magnetic Fluids, Mihai Viteazu Ave. 24, 300223 Timisoara, Romania.
- Politehnica University of Timisoara, Research Center for Complex Fluids Systems Engineering, Mihai Viteazul Ave. 1, 300222 Timisoara, Romania
| |
Collapse
|
2
|
Wei X, Wang Y, Cao Z, Mbemba D, Iqbal A, Wu Z. Large Aberration Correction by Magnetic Fluid Deformable Mirror with Model-Based Wavefront Sensorless Control Algorithm. Int J Mol Sci 2019; 20:E3697. [PMID: 31357727 PMCID: PMC6695980 DOI: 10.3390/ijms20153697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Revised: 07/23/2019] [Accepted: 07/24/2019] [Indexed: 11/16/2022] Open
Abstract
Magnetic fluid is a stable colloidal suspension of nano-sized, single-domain ferri/ferromagnetic particles dispersed in a liquid carrier. The liquid can be magnetized by the ferromagnetic particles aligned with the external magnetic field, which can be used as a wavefront corrector to correct the large aberrations up to more than 100 µm in adaptive optics (AO) systems. Since the measuring range of the wavefront sensor is normally small, the application of the magnetic fluid deformable mirror (MFDM) is limited with the WFS based AO system. In this paper, based on the MFDM model and the relationship between the second moment (SM) of the aberration gradients and the far-field intensity distribution, a model-based wavefront sensorless (WFSless) control algorithm is proposed for the MFDM. The correction performance of MFDM using the model-based control algorithm is evaluated in a WFSless AO system setup with a prototype MFDM, where a laser beam with unknown aberrations is supposed to produce a focused spot on the CCD. Experimental results show that the MFDM can be used to effectively compensate for unknown aberrations in the imaging system with the proposed model-based control algorithm.
Collapse
Affiliation(s)
- Xiang Wei
- Department of Precision Mechanical Engineering, Shanghai University, Shanghai 200444, China
| | - Yuanyuan Wang
- Department of Precision Mechanical Engineering, Shanghai University, Shanghai 200444, China
| | - Zhan Cao
- Department of Precision Mechanical Engineering, Shanghai University, Shanghai 200444, China
| | - Dziki Mbemba
- Department of Precision Mechanical Engineering, Shanghai University, Shanghai 200444, China
| | - Azhar Iqbal
- Dunlap Institute for Astronomy and Astrophysics, University of Toronto, Toronto, ON M5S 3H4, Canada
| | - Zhizheng Wu
- Department of Precision Mechanical Engineering, Shanghai University, Shanghai 200444, China.
| |
Collapse
|