Momose H, Murayama A, Yamada N, Matsubayashi K, Matsuoka S, Ikebe E, Kuramitsu M, Muramatsu M, Kato T, Hamaguchi I. Performance evaluation of in vitro diagnostic kits for hepatitis B virus infection using the regional reference panel of Japan. Virol J 2023; 20:93. [PMID: 37165426 PMCID: PMC10170722 DOI: 10.1186/s12985-023-02054-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Accepted: 04/26/2023] [Indexed: 05/12/2023] Open
Abstract
BACKGROUND Hepatitis B virus (HBV) infection is a global public health concern. Precise and sensitive detection of viral markers, including HBV DNA and HBs antigen (Ag), is essential to determine HBV infection. METHODS The sensitivities and specificities of 5 HBV DNA and 14 HBsAg kits were evaluated using World Health Organization International Standards (WHO IS) and the Regional Reference Panel (RRP) consisting of 64 HBsAg-negative and 80 HBsAg-positive specimens. RESULTS All 5 HBV DNA kits detected HBV DNA in the WHO IS at a concentration of 10 IU/mL. The sensitivity and specificity to the RRP were 98.8-100% and 96.9-100%, respectively. HBV DNA titers were well correlated among the 5 kits regardless of HBV genotype. However, discordance of the HBV DNA titer was found in 5 specimens measured by CAP/CTM HBV v2.0. Among 12 automated HBsAg kits, the minimum detectable concentrations in the WHO IS varied from 0.01 to 0.1 IU/mL. Two lateral flow assays were positive for WHO IS concentrations greater than or equal to 1.0 and 0.1 IU/mL, respectively. When analyzed by the RRP, 12 automated kits exhibited a sensitivity of 98.8-100%, and 2 lateral flow assays showed sensitivities of 93.8% and 100%. The specificities of HBsAg kits were 100%. In the quantification of HBsAg, some kits showed a poor correlation of measurements with each other and showed up to a 1.7-fold difference in the regression coefficient of HBsAg titers. There were variations in the correlations of measurements among HBsAg kits when analyzed by genotype. CONCLUSIONS Five HBV DNA kits showed sufficient sensitivity and specificity to determine HBV infection. HBV DNA titers were compatible with each other irrespective of HBV genotypes. HBsAg kits had enough sensitivity and specificity to screen for HBV infection. One of the lateral flow assays had a nearly equivalent sensitivity to that of the automated HBsAg kit. HBsAg titers quantified by the evaluated kits were not compatible across the kits. Genotype-dependent amino acid variations might affect the quantification of HBsAg titers.
Collapse
Affiliation(s)
- Haruka Momose
- Research Center for Biological Products in the Next Generation, National Institute of Infectious Diseases, 4-7-1 Gakuen, Musashimurayama, Tokyo, 208-0011, Japan
| | - Asako Murayama
- Department of Virology II, National Institute of Infectious Diseases, 1-23-1 Toyama, Shinjuku-ku, Tokyo, 162-8640, Japan
| | - Norie Yamada
- Department of Virology II, National Institute of Infectious Diseases, 1-23-1 Toyama, Shinjuku-ku, Tokyo, 162-8640, Japan
| | - Keiji Matsubayashi
- Central Blood Institute, Blood Service Headquarters, Japanese Red Cross Society, 2-1-67 Tatsumi, Koto-ku, Tokyo, 135-8521, Japan
| | - Sahoko Matsuoka
- Research Center for Biological Products in the Next Generation, National Institute of Infectious Diseases, 4-7-1 Gakuen, Musashimurayama, Tokyo, 208-0011, Japan
| | - Emi Ikebe
- Research Center for Biological Products in the Next Generation, National Institute of Infectious Diseases, 4-7-1 Gakuen, Musashimurayama, Tokyo, 208-0011, Japan
| | - Madoka Kuramitsu
- Research Center for Biological Products in the Next Generation, National Institute of Infectious Diseases, 4-7-1 Gakuen, Musashimurayama, Tokyo, 208-0011, Japan
| | - Masamichi Muramatsu
- Department of Virology II, National Institute of Infectious Diseases, 1-23-1 Toyama, Shinjuku-ku, Tokyo, 162-8640, Japan
| | - Takanobu Kato
- Department of Virology II, National Institute of Infectious Diseases, 1-23-1 Toyama, Shinjuku-ku, Tokyo, 162-8640, Japan.
| | - Isao Hamaguchi
- Research Center for Biological Products in the Next Generation, National Institute of Infectious Diseases, 4-7-1 Gakuen, Musashimurayama, Tokyo, 208-0011, Japan.
| |
Collapse
|
2
|
Alinity m, a Random-Access System, for Hepatitis B Virus DNA Quantification in Plasma and Whole Blood Collected on Dried Blood Spots. mSphere 2022; 7:e0008222. [PMID: 35477312 PMCID: PMC9241498 DOI: 10.1128/msphere.00082-22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
The International Liver Association recommends the use of accurate and sensitive molecular methods for determination of hepatitis B virus (HBV) DNA levels in plasma or serum of chronic HBsAg carriers. The level of HBV replication represents the strongest predictive biomarker associated with disease progression and long-term outcome of chronic HBV infection. The purpose of this study was to evaluate the ability to the new Alinity m System to detect and quantify HBV DNA in plasma and whole blood collected on dried blood spots (DBS). Paired plasma and DBS samples from patients chronically infected with various HBV genotypes were tested in parallel for HBV DNA detection and quantification. There is a linear relationship between HBV DNA levels measured in plasma samples using the Alinity m HBV assay and the Xpert HBV viral load assay, used for comparison. A slight deviation (0.03 ± 0.31 log IU/mL) was observed within the quantitative range. In DBS, HBV DNA levels closely correlated with levels measured in plasma. All patients had detectable and quantifiable HBV DNA by DBS testing, except for one patient with a plasma HBV DNA level above 2,000 IU/mL. In conclusion, the newly developed real-time PCR-based assay Alinity m HBV assay can correctly detect HBV DNA in DBS, especially for patients with blood HBV DNA levels above 2,000 IU/mL, and also accurately quantify HBV DNA in plasma samples. IMPORTANCE Hepatitis B virus is one of the most prevalent blood-borne viruses affecting the liver and causing acute and chronic hepatitis. Only a small proportion of people with HBV infection are diagnosed. HBV DNA measurement is critical in clinical practice for the diagnosis and treatment decisions of patients requiring antiviral therapy. Dried blood spot (DBS) collection provides a simple, practical, and acceptable alternative to venous blood collection, especially in community settings. We have demonstrated high sensitivity and specificity for HBV DNA detection in DBS compared to plasma samples, especially when using clinically relevant cutoffs of 2,000 and 20,000 IU/mL. Results support the use of DBS in community-based settings.
Collapse
|