1
|
Manousi N, Ntorkou M, Tzanavaras PD, Zacharis CK. A review of bioanalytical applications of microextraction techniques combined with derivatization. Bioanalysis 2023; 15:937-954. [PMID: 37638635 DOI: 10.4155/bio-2023-0121] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/29/2023] Open
Abstract
Microextraction techniques have attracted the attention of many researchers working in the field of bioanalysis due to their unique advantages, mainly in downsizing the scale of sample preparation steps. In parallel, analytical derivatization offers a powerful combination in terms of additional sensitivity, selectivity and compatibility with modern separation techniques. The aim of this review is to discuss the most recent advances in bioanalytical sample preparation based on the combination of microextraction and analytical derivatization. Both innovative fundamental reports and analyte-targeted applications are included and discussed. Dispersive liquid-liquid extraction and solid-phase microextraction are the most common techniques that typically combined with derivatization, while the development of novel and greener protocols is receiving substantial consideration in the field of analytical chemistry.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Pharmaceutical Analysis, School of Pharmacy, Aristotle University of Thessaloniki, Thessaloniki, GR-54124, Greece
| | - Marianna Ntorkou
- Laboratory of Pharmaceutical Analysis, School of Pharmacy, Aristotle University of Thessaloniki, Thessaloniki, GR-54124, Greece
| | - Paraskevas D Tzanavaras
- Laboratory of Analytical Chemistry, School of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, GR-54124, Greece
| | - Constantinos K Zacharis
- Laboratory of Pharmaceutical Analysis, School of Pharmacy, Aristotle University of Thessaloniki, Thessaloniki, GR-54124, Greece
| |
Collapse
|
2
|
Low-Dose Benzene Exposure Monitoring of Oil Refinery Workers: Inhalation and Biomarkers. ATMOSPHERE 2022. [DOI: 10.3390/atmos13030450] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Airborne benzene in workplaces has progressively decreased due to preventive actions and the redesigning of facility processes. Professionals who assess occupational exposure should select techniques to detect benzene levels comparable to ambient air exposure. Thus, sensitive biomarkers are needed to discriminate the effects of confounding factors, such as smoking or sorbic acid (SA). In order to identify sensitive biomarkers and to study their correlation with confounding factors, 23 oil refinery workers were enrolled in the study; their airborne benzene exposures and biomarkers were monitored. Urinary benzene (U-B), t,t-muconic acid (t,t-MA), and S-phenylmercapturic acid (SPMA) were quantified. Urinary cotinine (U-C) and t,t-sorbic acid (t,t-SA) were evaluated to flag smoking and SA intake, respectively. The benzene measured in personal inhalation sampling ranged from 0.6 to 83.5 (median 1.7) µg/m3. The concentration range of the biomarkers, U-B, t,t-MA, and SPMA, were 18–4893 ng/m3, <10–79.4 µg/g creatinine, and <0.5–3.96 µg/g creatinine, respectively. Pearson tests were carried out; the best correlations were between airborne benzene and U-B (µg/L r = 0.820, p < 0.001) and between benzene and SPMA (g/L r = 0.812, p < 0.001), followed by benzene and t,t-MA (mg/L r = 0.465, p = 0.039). From our study, U-B and SPMA result to be the most reliable biomarkers to assess the internal number of low doses of benzene exposure, thanks to their specificity and sensitivity.
Collapse
|
3
|
Dugheri S, Mucci N, Cappelli G, Trevisani L, Bonari A, Bucaletti E, Squillaci D, Arcangeli G. Advanced Solid-Phase Microextraction Techniques and Related Automation: A Review of Commercially Available Technologies. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY 2022; 2022:8690569. [PMID: 35154846 PMCID: PMC8837452 DOI: 10.1155/2022/8690569] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 01/05/2022] [Accepted: 01/07/2022] [Indexed: 06/14/2023]
Abstract
The solid-phase microextraction (SPME), invented by Pawliszyn in 1989, today has a renewed and growing use and interest in the scientific community with fourteen techniques currently available on the market. The miniaturization of traditional sample preparation devices fulfills the new request of an environmental friendly analytical chemistry. The recent upswing of these solid-phase microextraction technologies has brought new availability and range of robotic automation. The microextraction solutions propose today on the market can cover a wide variety of analytical fields and applications. This review reports on the state-of-the-art innovative solid-phase microextraction techniques, especially those used for chromatographic separation and mass-spectrometric detection, given the recent improvements in availability and range of automation techniques. The progressively implemented solid-phase microextraction techniques and related automated commercially available devices are classified and described to offer a valuable tool to summarize their potential combinations to face all the laboratories requirements in terms of analytical applications, robustness, sensitivity, and throughput.
Collapse
Affiliation(s)
- Stefano Dugheri
- Industrial Hygiene and Toxicology Laboratory, University Hospital Careggi, Florence, Italy
| | - Nicola Mucci
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Giovanni Cappelli
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Lucia Trevisani
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | | | - Elisabetta Bucaletti
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Donato Squillaci
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Giulio Arcangeli
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| |
Collapse
|
4
|
Yue SW, Zhou YL, Peng XT, Zhao Q. Application of a novel nylon needle filter-based solid-phase extraction device to determination of 1-hydroxypyrene in urine. J Sep Sci 2022; 45:1262-1272. [PMID: 35029014 DOI: 10.1002/jssc.202100830] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 01/04/2022] [Accepted: 01/10/2022] [Indexed: 11/12/2022]
Abstract
In this work, a simple and miniaturized solid-phase extraction device was constructed by connecting a commercial nylon needle filter to a syringe, which was applied for extracting 1-hydroxypyrene from urine sample via hydrophobic and hydrogen bond interactions. The nylon membrane in the needle filter acted as the solid-phase extraction adsorbent, meanwhile, it filtered the particles in the urine sample. To obtain high extraction efficiency, key parameters influencing extraction recovery were investigated. The entire pretreatment process was accomplished within 5 min under the optimal conditions. By coupling HPLC-UV, a rapid, low-cost, and convenient nylon needle filter-based method was established for the analysis of 1-hydroxypyrene in complex urine matrix. Within the linearity range of 0.2-1000 μg/L, the method exhibited a satisfactory correlation coefficient (R = 0.9999). The limit of detection was 0.06 μg/L, and the recoveries from urine sample spiked with three concentrations (5, 20, and 100 μg/L) ranged from 105.8% to 113.1% with the relative standard deviations less than 6.7% (intra-day, n = 6) and 8.9% (inter-day, n = 4). Finally, the proposed method was successfully applied for detecting 1-hydroxypyrene in urine samples from college students, smokers, gas station workers, and chip factory workers. The detected concentration in actual urine samples ranged from 0.46 to 5.26 μg/L. Taken together, this simple and cost-effective nylon needle filter-based solid-phase extraction device showed an excellent application potential for pretreating hydrophobic analytes from aqueous samples. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Shi-Wen Yue
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Wuhan University of Science and Technology, Wuhan, 430074, China
| | - Yi-Lian Zhou
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Wuhan University of Science and Technology, Wuhan, 430074, China
| | - Xi-Tian Peng
- Institute of Agricultural Quality Standards and Testing Technology Research, Hubei Academy of Agricultural Sciences, Wuhan, 430074, China
| | - Qin Zhao
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, School of Public Health, Wuhan University of Science and Technology, Wuhan, 430074, China
| |
Collapse
|
5
|
Sun S, Mao W, Tao S, Zou X, Tian S, Qian S, Yao C, Zhang G, Chen M. Polycyclic Aromatic Hydrocarbons and the Risk of Kidney Stones in US Adults: An Exposure-Response Analysis of NHANES 2007-2012. Int J Gen Med 2021; 14:2665-2676. [PMID: 34188522 PMCID: PMC8232959 DOI: 10.2147/ijgm.s319779] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Accepted: 06/01/2021] [Indexed: 12/23/2022] Open
Abstract
Background Polycyclic aromatic hydrocarbons (PAHs) exposure may cause various diseases. However, the association between PAHs exposure and kidney stones remains unclear. The purpose of this study was to examine the relationship between PAHs and the risk of kidney stones in the US population. Methods The study included a total of 30,442 individuals (≥20 years) from the 2007–2012 National Health and Nutrition Examination Survey (NHANES). Nine urinary PAHs were included in this study. Logistic regression and dose–response curves were used to evaluate the association between PAHs and the risk of kidney stones. Results We selected 4385 participants. The dose–response curves showed a significant positive association between total PAHs, 2-hydroxynaphthalene, 1-hydroxyphenanthrene, 2-hydroxyphenanthrene, 9-hydroxyfluorene and the risk of kidney stones after adjusting for confounding factors. Compared with the low group, an increased risk of kidney stones was observed in the high group of total PAHs [OR (95% CI), 1.32 (1.06–1.64), P=0.013], 2-hydroxynaphthalene [OR (95% CI), 1.37 (1.10–1.71), P=0.005], 1-hydroxyphenanthrene [OR (95% CI), 1.24 (1.00–1.54), P=0.046] and 9-hydroxyfluorene [OR (95% CI), 1.36 (1.09–1.70), P=0.007]. Conclusion High levels of PAHs were positively associated with the risk of kidney stones in the US population.
Collapse
Affiliation(s)
- Si Sun
- Department of Urology, Zhongda Hospital, Southeast University, Nanjing, 210009, People's Republic of China
| | - Weipu Mao
- Department of Urology, Zhongda Hospital, Southeast University, Nanjing, 210009, People's Republic of China.,Surgical Research Center, Institute of Urology, Southeast University Medical School, Nanjing, 210009, People's Republic of China.,Department of Urology, Nanjing Lishui District People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, Nanjing, 211200, People's Republic of China
| | - Shuchun Tao
- Department of Urology, Zhongda Hospital, Southeast University, Nanjing, 210009, People's Republic of China
| | - Xiangyu Zou
- Department of Urology, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, 200127, People's Republic of China
| | - Shengwei Tian
- Department of Urology, Zhongda Hospital, Southeast University, Nanjing, 210009, People's Republic of China
| | - Siwei Qian
- Department of Urology, Zhongda Hospital, Southeast University, Nanjing, 210009, People's Republic of China
| | - Chi Yao
- Department of Urology, Zhongda Hospital, Southeast University, Nanjing, 210009, People's Republic of China
| | - Guangyuan Zhang
- Department of Urology, Zhongda Hospital, Southeast University, Nanjing, 210009, People's Republic of China.,Surgical Research Center, Institute of Urology, Southeast University Medical School, Nanjing, 210009, People's Republic of China
| | - Ming Chen
- Department of Urology, Zhongda Hospital, Southeast University, Nanjing, 210009, People's Republic of China.,Surgical Research Center, Institute of Urology, Southeast University Medical School, Nanjing, 210009, People's Republic of China.,Department of Urology, Nanjing Lishui District People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, Nanjing, 211200, People's Republic of China
| |
Collapse
|
6
|
Daryanavard SM, Zolfaghari H, Abdel-Rehim A, Abdel-Rehim M. Recent applications of microextraction sample preparation techniques in biological samples analysis. Biomed Chromatogr 2021; 35:e5105. [PMID: 33660303 DOI: 10.1002/bmc.5105] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 01/26/2021] [Accepted: 02/05/2021] [Indexed: 12/11/2022]
Abstract
Analysis of biological samples is affected by interfering substances with chemical properties similar to those of the target analytes, such as drugs. Biological samples such as whole blood, plasma, serum, urine and saliva must be properly processed for separation, purification, enrichment and chemical modification to meet the requirements of the analytical instruments. This causes the sample preparation stage to be of undeniable importance in the analysis of such samples through methods such as microextraction techniques. The scope of this review will cover a comprehensive summary of available literature data on microextraction techniques playing a key role for analytical purposes, methods of their implementation in common biological samples, and finally, the most recent examples of application of microextraction techniques in preconcentration of analytes from urine, blood and saliva samples. The objectives and merits of each microextration technique are carefully described in detail with respect to the nature of the biological samples. This review presents the most recent and innovative work published on microextraction application in common biological samples, mostly focused on original studies reported from 2017 to date. The main sections of this review comprise an introduction to the microextraction techniques supported by recent application studies involving quantitative and qualitative results and summaries of the most significant, recently published applications of microextracion methods in biological samples. This article considers recent applications of several microextraction techniques in the field of sample preparation for biological samples including urine, blood and saliva, with consideration for extraction techniques, sample preparation and instrumental detection systems.
Collapse
Affiliation(s)
| | - Hesane Zolfaghari
- Department of Chemistry, Faculty of Science, University of Hormozgan, Bandar-Abbas, Iran
| | - Abbi Abdel-Rehim
- Department of Chemical Engineering and Biotechnology, Cambridge University, Cambridge, UK
| | - Mohamed Abdel-Rehim
- Functional Materials Division, Department of Applied Physics, School of Engineering Sciences, KTH Royal Institute of Technology, Stockholm, Sweden.,Department of Clinical Neuroscience, Centre for Psychiatry Research, Karolinska Institutet, Solna, Sweden
| |
Collapse
|
7
|
Kim U, Karthikraj R. Solid‐phase microextraction for the human biomonitoring of environmental chemicals: Current applications and future perspectives. J Sep Sci 2020; 44:247-273. [DOI: 10.1002/jssc.202000830] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 10/18/2020] [Accepted: 11/13/2020] [Indexed: 01/09/2023]
Affiliation(s)
- Un‐Jung Kim
- Department of Earth & Environmental Sciences University of Texas at Arlington Arlington Texas USA
| | | |
Collapse
|
8
|
Gan D, Huang D, Yang J, Zhang L, Ou S, Feng Y, Peng Y, Peng X, Zhang Z, Zou Y. Assessment of kitchen emissions using a backpropagation neural network model based on urinary hydroxy polycyclic aromatic hydrocarbons. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2020; 265:114915. [PMID: 32535415 DOI: 10.1016/j.envpol.2020.114915] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 05/17/2020] [Accepted: 05/29/2020] [Indexed: 06/11/2023]
Abstract
Kitchen emissions are mixed indoor air pollutants with adverse health effects, but the large-scale assessment is limited by costly equipment and survey methods. This study aimed to discuss the application of backpropagation (BP) neural network models in the assessment of kitchen emissions based on the exposure marker. A total of 3686 participants were recruited for the kitchen survey, and their sleep quality was measured by the Pittsburgh sleep quality index (PSQI). After excluding the confounders, 365 participants were selected to assess their urinary hydroxy polycyclic aromatic hydrocarbons (OH-PAHs) concentrations by ultra-high-performance liquid chromatography/tandem mass spectrometry. Two BP neural network models were then set up using the survey and detection data from the 365 participants and used to predict the total urinary OH-PAHs concentrations of all participants. The total urinary OH-PAHs and 1-hydroxy-naphthalene (1-OHNap) concentrations were significantly higher among the 365 participants with poor sleep quality (global PSQI score > 5; P < 0.05). Results from internal and external validation showed that our model has high credibility (model 2). Further, the participants with higher predicted total urinary OH-PAHs concentrations were associated with the global PSQI score of >5 (odds ratio (OR) = 1.284, 95% confidence interval (CI) = 1.082-1.525 for participants with predicted total urinary OH-PAHs concentrations of over 1.897 μg/mmol creatinine in model 1, and OR = 1.467, 95% CI = 1.240-1.735 for participants with predicted total urinary OH-PAHs concentrations of over 2.253 μg/mmol creatinine in model 2) after adjusting for the confounders. Findings suggest that the BP neural network model is suitable for assessing kitchen emissions, and the urinary OH-PAHs concentrations can be taken as the model outlay.
Collapse
Affiliation(s)
- Dong Gan
- Department of Toxicology, School of Public Health, Guangxi Medical University, Nanning, 530021, China; Guangxi Colleges and Universities Key Laboratory of Prevention and Control of Highly Prevalent Diseases, Guangxi Medical University, Nanning, 530021, China
| | - Daizheng Huang
- Department of Biomedical Engineering, School of Preclinical Medicine, Guangxi Medical University, Nanning, 530021, China
| | - Jie Yang
- Department of Toxicology, School of Public Health, Guangxi Medical University, Nanning, 530021, China; Guangxi Colleges and Universities Key Laboratory of Prevention and Control of Highly Prevalent Diseases, Guangxi Medical University, Nanning, 530021, China
| | - Li'e Zhang
- Department of Occupational and Environmental Health, School of Public Health, Guangxi Medical University, Nanning, 530021, China; Guangxi Colleges and Universities Key Laboratory of Prevention and Control of Highly Prevalent Diseases, Guangxi Medical University, Nanning, 530021, China
| | - Songfeng Ou
- Department of Toxicology, School of Public Health, Guangxi Medical University, Nanning, 530021, China
| | - Yumeng Feng
- Department of Toxicology, School of Public Health, Guangxi Medical University, Nanning, 530021, China
| | - Yang Peng
- Department of Occupational and Environmental Health, School of Public Health, Guangxi Medical University, Nanning, 530021, China; Guangxi Colleges and Universities Key Laboratory of Prevention and Control of Highly Prevalent Diseases, Guangxi Medical University, Nanning, 530021, China
| | - Xiaowu Peng
- Center for Environmental Health Research, South China Institute of Environmental Sciences, Ministry of Environmental Protection, Guangzhou, 510655, China
| | - Zhiyong Zhang
- School of Public Health, Guilin Medical University, Guilin, 541004, China
| | - Yunfeng Zou
- Department of Toxicology, School of Public Health, Guangxi Medical University, Nanning, 530021, China; Guangxi Colleges and Universities Key Laboratory of Prevention and Control of Highly Prevalent Diseases, Guangxi Medical University, Nanning, 530021, China.
| |
Collapse
|
9
|
Jalili V, Barkhordari A, Ghiasvand A. Solid-phase microextraction technique for sampling and preconcentration of polycyclic aromatic hydrocarbons: A review. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104967] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
10
|
Bormann JL, Maibach HI. Effects of anatomical location on in vivo percutaneous penetration in man. Cutan Ocul Toxicol 2020; 39:213-222. [DOI: 10.1080/15569527.2020.1787434] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Jordan L. Bormann
- Sanford School of Medicine, University of South Dakota, Sioux Falls, SD, USA
| | | |
Collapse
|
11
|
George MJ, Madala NE, Dubery IA. Application of an agitation-assisted dispersed solvent microextraction for analysis of naphthalene and its derivatives from aqueous matrices. ENVIRONMENTAL MONITORING AND ASSESSMENT 2020; 192:494. [PMID: 32642872 DOI: 10.1007/s10661-020-08457-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Accepted: 06/23/2020] [Indexed: 06/11/2023]
Abstract
Agitation-assisted dispersive liquid-liquid extraction without a dispersing solvent is lately receiving considerable attention owing to the low to no solvent loss relative to its predecessor, which suffers severe extracting solvent loss. Herein, we report the application of a simple agitation-assisted dispersive liquid-liquid microextraction method, without a disperser solvent, for the extraction of naphthalene and its derivatives from aqueous solutions. Under the optimised conditions, namely, 25 μL 3:1 mixture of dichloroethane and ethylacetate with 20 s agitation, in 2-mL aqueous solutions containing 10% NaCl, the method demonstrated acceptable figures of merit: linearity-R2 ≥ 0.9914 in the concentration range 0.5-50 ng/mL, repeatability (%RSD ≤ 12.9 for n = 15) and limits of detection (0.034-0.081 ng/mL). The recoveries obtained from the spiked dam water sample were also satisfactory (94-103%). These parameters are comparable with those reported in literature, especially for dispersive liquid-liquid microextraction techniques albeit for different analytes. Despite only naphthol being detected in one of the three sampled sites, the method shows considerable promise for routine monitoring of river and dam water quality subject to accuracy validation using certified reference materials.
Collapse
Affiliation(s)
- Mosotho J George
- Department of Chemistry and Chemical Technology, National University of Lesotho, P.O. Roma, Roma, 180, Lesotho.
- Department of Biochemistry, University of Johannesburg, P.O. Box 524, Auckland Park, Johannesburg, Gauteng, 2006, South Africa.
| | - Ntakadzeni E Madala
- Department of Biochemistry, University of Johannesburg, P.O. Box 524, Auckland Park, Johannesburg, Gauteng, 2006, South Africa
- Department of Biochemistry, University of Venda, Thohoyandou, Limpopo, South Africa
| | - Ian A Dubery
- Department of Biochemistry, University of Johannesburg, P.O. Box 524, Auckland Park, Johannesburg, Gauteng, 2006, South Africa
| |
Collapse
|
12
|
Sun L, Zhu S, Zheng Z, Sun J, Zhao XE, Liu H. 9-Plex ultra high performance liquid chromatography tandem mass spectrometry determination of free hydroxyl polycyclic aromatic hydrocarbons in human plasma and urine. J Chromatogr A 2020; 1623:461182. [DOI: 10.1016/j.chroma.2020.461182] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Revised: 04/27/2020] [Accepted: 04/29/2020] [Indexed: 02/07/2023]
|
13
|
Dugheri S, Mucci N, Cappelli G, Bonari A, Campagna M, Arcangeli G, Bartolucci G. New fully automated gas chromatographic analysis of urinary S-phenylmercapturic acid in isotopic dilution using negative chemical ionization with isobutane as reagent gas. JOURNAL OF MASS SPECTROMETRY : JMS 2020; 55:e4481. [PMID: 31770470 DOI: 10.1002/jms.4481] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2019] [Revised: 11/19/2019] [Accepted: 11/22/2019] [Indexed: 06/10/2023]
Abstract
The determination of urinary S-phenylmercapturic acid (S-PMA) represents the most reliable biomarker to monitor the intake risk of airborne benzene. Recently, the European Chemical Agency deliberated new occupational exposure limits for benzene and recommended an S-PMA biological limit value of 2-μg/g creatinine. This limit is an order of magnitude lower than the previous one, and its determination constitutes a challenge in the analytical field. We developed and validated a method that allows the fully automated and sensitive determination of S-PMA by the use of gas-chromatography negative chemical ionization tandem mass spectrometry in isotopic dilution. For negative chemical ionization, we selected a mixture of 1% isobutane in argon as reactive gas, by studying its chemical ionization mechanism and optimal parameters compared with pure isobutane or pure methane. This gas mixture produces a more abundant signal of the target analyte than isobutane or methane, and it extended the operative lifetime of the ion source, enabling us to start a high-throughput approach of the S-PMA analysis. Moreover, energy-resolved mass spectrometry experiments were carried out to refine the MS/MS analysis conditions, testing nitrogen and argon as collision gases. The method optimization was pursued by a chemometric model by using the experimental design. The quantification limit for S-PMA was 0.10 μg/L. Accuracy (between 98.3% and 99.6%) and precision (ranging from 1.6% to 6.4%) were also evaluated. In conclusion, the newly developed assay represents a powerful tool for the robust, reliable, and sensitive quantification of urinary S-PMA, and because of its automation, it is well suited for application in large environmental and biological monitoring.
Collapse
Affiliation(s)
- Stefano Dugheri
- Industrial Hygiene and Toxicology Laboratory, Occupational Medicine Unit, Careggi University Hospital, Florence, Italy
| | - Nicola Mucci
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Giovanni Cappelli
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | | | - Marcello Campagna
- Department of Medical Science and Public Health, University of Cagliari, Monserrato, Italy
| | - Giulio Arcangeli
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Gianluca Bartolucci
- Department of Neurosciences, Psychology, Drug Research and Child Health, University of Florence, Sesto Fiorentino, Italy
| |
Collapse
|
14
|
|
15
|
Liu Y, Li Z, Zhang Z, Zhao T, Wang M, Wang X. Determination of Urinary Hydroxyl PAHs Using Graphene Oxide@Diatomite Based Solid-Phase Extraction and High-Performance Liquid Chromatography. Molecules 2019; 24:molecules24224186. [PMID: 31752256 PMCID: PMC6891718 DOI: 10.3390/molecules24224186] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Revised: 11/10/2019] [Accepted: 11/18/2019] [Indexed: 11/16/2022] Open
Abstract
A diatomite supported graphene oxide composite (GO@Dt–NH2) was fabricated and explored as a solid-phase extraction adsorbent coupled with high performance liquid chromatography to determine the trace hydroxyl polycyclic aromatic hydrocarbons (2-hydroxy-naphthalene, 2-hydroxy-fluorene, 1-hydroxy-phenanthrene, and 1-hydroxy-pyrene) in urine samples. The fabricated composites were characterized by X-ray powder diffractometry and scanning electron microscopy. GO@Dt–NH2 offered enhanced adsorption affinity towards the analytes compared with the bare diatomite. The amount of graphene oxide and the factors affecting solid-phase extraction were investigated in detail. Under the optimized conditions, the method gave good linearity (0.30–200 ng/mL) and a low detection limit (0.10–0.15 ng/mL) for the hydroxyl polycyclic aromatic hydrocarbons. The average recovery for spiked urine samples with three levels ranged from 90.6% to 100%. The intra-day and inter-day relative standard deviations were in the range of 1.8–6.4% and 2.7–11.8%, respectively. Besides, the GO@Dt–NH2 provided enrichment factors of 18–20 and superior purification ability. The developed method was successfully applied to the determination of hydroxyl polycyclic aromatic hydrocarbons in urine samples from smoking volunteers.
Collapse
Affiliation(s)
| | | | | | | | - Manman Wang
- Correspondence: (M.W.); (X.W.); Tel.: +86-031-5880-5576 (M.W.); +86-031-5880-5576 (X.W.)
| | - Xuesheng Wang
- Correspondence: (M.W.); (X.W.); Tel.: +86-031-5880-5576 (M.W.); +86-031-5880-5576 (X.W.)
| |
Collapse
|
16
|
Liu H, Wang X, Fan H, Dang S. Durable molybdenum oxide coated solid-phase microextraction fiber for highly selective and efficient extraction of polycyclic aromatic hydrocarbons in water. J Sep Sci 2019; 42:1878-1885. [PMID: 30839165 DOI: 10.1002/jssc.201801280] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2018] [Revised: 02/18/2019] [Accepted: 03/01/2019] [Indexed: 12/21/2022]
Abstract
A bonding method was developed for coating molybdenum oxides onto a steel wire substrate, which was used as a solid-phase microextraction fiber, was coupled with gas chromatography. Based on the characterization, it is found that the as-prepared molybdenum oxides material contained a nanobelt structure with a uniform size and good dispersibility. In addition, there were a large number of small protrusions on the surface of the nanobelts. These characteristics provided a large specific surface area for extraction. Molybdenum oxides exhibited a high extraction selectivity for polycyclic aromatic hydrocarbons owing to its moderate coordination. After the optimization of the factors, method detection limits of < 1.25 μg/L were achieved, and the calibration curves were linear within the range of 2-600 μg/L. In addition, repeatability was demonstrated, and the relative standard deviation < 6.4%. The molybdenum oxides coating had a high scratch resistance, which could effectively prevent coating wear and failure. Combined with the high thermal and chemical stability, the service life of the coating was improved and could be used 150 times without a significant reduction in the extraction performance. Finally, the as-prepared fiber had a comparable extraction capacity and higher partition coefficients that those of commercial polyacrylate fibers.
Collapse
Affiliation(s)
- Hongmei Liu
- School of Chemical and Biological Engineering, Lanzhou Jiaotong University, Lanzhou, P. R. China
| | - Xiaoqi Wang
- School of Chemical and Biological Engineering, Lanzhou Jiaotong University, Lanzhou, P. R. China
| | - Hua Fan
- School of Chemical and Biological Engineering, Lanzhou Jiaotong University, Lanzhou, P. R. China
| | - Shihao Dang
- School of Chemical and Biological Engineering, Lanzhou Jiaotong University, Lanzhou, P. R. China
| |
Collapse
|