1
|
Souza ID, Queiroz MEC. Organic-silica hybrid monolithic sorbents for sample preparation techniques: A review on advances in synthesis, characterization, and applications. J Chromatogr A 2024; 1713:464518. [PMID: 38000199 DOI: 10.1016/j.chroma.2023.464518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 11/14/2023] [Accepted: 11/16/2023] [Indexed: 11/26/2023]
Abstract
Organic-silica hybrid monolithic materials have attracted considerable attention as potential stationary phases in separation science. These materials combine the advantages of organic polymer and silica-based monoliths, including easy preparation, lower back pressure, high permeability, excellent mechanical strength, thermal stability, and tunable surface chemistry with high surface area and selectivity. The outstanding chromatographic efficiency as stationary phase of hybrid monolithic capillary columns for capillary liquid chromatography and capillary electrochromatography has been reported in many papers. Organic-silica hybrid monolithic materials have also been extensively used in the field of sample preparation. Owing to their surface functionalities, these porous sorbents offer unique selectivity for pre-concentration of different analytes in the most complex matrixes by fast dynamic transport. These sorbents not only improve the analytical method sensitivity, but also introduce novelties in terms of extraction devices and instrument coupling strategies. The current review covers the period spanning from 2017 to 2023 and describes the properties of organic-inorganic hybrid monolithic materials, the present status of this technology and summarizes recent developments in their use as innovative sorbents for microextraction sample preparation techniques (solid phase microextraction with pipette tip, offline in-tube SPME, in-tube SPME online with LC, and in-tube SPME directly coupled with mass spectrometry). Aspects such as the synthesis methods (sol-gel process, one-pot approach, and polyhedral oligomeric silsesquioxanes-based procedure), characterization techniques, and strategies to improve extraction efficiency in various applications in different areas (environmental, food, bioanalysis, and proteomics) are also discussed.
Collapse
Affiliation(s)
- Israel D Souza
- Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, University of Sao Paulo, Av. Bandeirantes, 3900, Ribeirao Preto, SP 14040-901, Brazil.
| | - Maria Eugênia C Queiroz
- Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, University of Sao Paulo, Av. Bandeirantes, 3900, Ribeirao Preto, SP 14040-901, Brazil
| |
Collapse
|
2
|
Jiang J, Zhang M, Xu Z, Yang Y, Wang Y, Zhang H, Yu K, Kan G, Jiang Y. Recent Advances in Catecholamines Analytical Detection Methods and Their Pretreatment Technologies. Crit Rev Anal Chem 2023:1-20. [PMID: 37733491 DOI: 10.1080/10408347.2023.2258982] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023]
Abstract
Catecholamines (CAs), including adrenaline, noradrenaline, and dopamine, are neurotransmitters and hormones that play a critical role in regulating the cardiovascular system, metabolism, and stress response in the human body. As promising methods for real-time monitoring of catecholamine neurotransmitters, LC-MS detectors have gained widespread acceptance and shown significant progress over the past few years. Other detection methods such as fluorescence detection, colorimetric assays, surface-enhanced Raman spectroscopy, and surface plasmon resonance spectroscopy have also been developed to varying degrees. In addition, efficient pretreatment technology for CAs is flourishing due to the increasing development of many highly selective and recoverable materials. There are a few articles that provide an overview of electrochemical detection and efficient enrichment, but a comprehensive summary focusing on analytical detection technology is lacking. Thus, this review provides a comprehensive summary of recent analytical detection technology research on CAs published between 2017 and 2022. The advantages and limitations of relevant methods including efficient pretreatment technologies for biological matrices and analytical methods used in combination with pretreatment technology have been discussed. Overall, this review article provides a better understanding of the importance of accurate CAs measurement and offers perspectives on the development of novel methods for disease diagnosis and research in this field.
Collapse
Affiliation(s)
- Jie Jiang
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, China
- State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin, Heilongjiang, China
| | - Meng Zhang
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, China
| | - Zhilong Xu
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, China
| | - Yali Yang
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, China
| | - Yimeng Wang
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, Heilongjiang, China
- Elite Engineer School, Harbin Institute of Technology, Harbin, Heilongjiang, China
| | - Hong Zhang
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
| | - Kai Yu
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
| | - Guangfeng Kan
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
| | - Yanxiao Jiang
- School of Marine Science and Technology, Harbin Institute of Technology (WeiHai), Weihai, Shandong, China
| |
Collapse
|
3
|
Souza ID, Anderson JL, Tumas V, Queiroz MEC. Direct coupling of fiber-in-tube solid-phase microextraction with tandem mass spectrometry to determine amyloid beta peptides as biomarkers for Alzheimer's disease in cerebrospinal fluid samples. Talanta 2023; 254:124186. [PMID: 36521326 DOI: 10.1016/j.talanta.2022.124186] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Revised: 11/29/2022] [Accepted: 12/07/2022] [Indexed: 12/14/2022]
Abstract
Current research efforts at neurological diseases have focused on identifying novel biomarkers to aid in diagnosis, to provide accurate prognostic information, and to monitor disease progression. This study presents the direct coupling of fiber-in-tube solid-phase microextraction to tandem mass spectrometry as a reliable method to determine amyloid beta peptides (Aβ38, Aβ40, and Aβ42) as biomarkers for Alzheimer's disease in cerebrospinal fluid (CSF) samples. To obtain the biocompatible fiber-in-tube SPME capillary, a PEEK tube segment was longitudinally packed with fine fibers [nitinol wires coated with a zwitterionic polymeric ionic liquid], to act as selective extraction medium. The fiber-in-tube SPME-MS/MS method integrated analyte extraction/enrichment and sample cleanup (exclusion of interferents) into one step. The method provided lower limits of quantification (LLOQ: 0.2 ng mL-1 for Aβ38 and 0.1 ng mL-1 for Aβ40 and Aβ42), high precision (CV lower than 11.6%), and high accuracy (relative standard deviation lower than 15.1%). This method was successfully applied to determine Aβ peptides in CSF samples obtained from AD patients (n = 8) and controls (healthy volunteers, n = 10). Results showed that Aβ42 levels in the CSF samples obtained from AD patients were significantly lower compared to healthy controls (p < 0.05). On the basis of the ROC analysis results, the Aβ42/Aβ40 ratio (AUC = 0.950, p < 0.01; 95%) performed significantly better than Aβ42 alone (AUC = 0.913, p < 0.01; 95%) in discriminating between AD patients and healthy controls and presented better diagnostic ability for AD. The novelties of this study are not only related to evaluating Aβ peptides as AD biomarkers, but also to demonstrating direct online coupling of fiber-in-tube SPME with MS/MS as a quantitative high-throughput method for bioanalysis.
Collapse
Affiliation(s)
- Israel D Souza
- Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, University of Sao Paulo, Ribeirao Preto, SP, Brazil
| | - Jared L Anderson
- Department of Chemistry, Iowa State University, Ames, IA, United States
| | - Vitor Tumas
- Department of Neurosciences and Behavioral Sciences, Ribeirao Preto Medical School of University of São Paulo, Ribeirao Preto, SP, Brazil
| | - Maria Eugênia C Queiroz
- Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, University of Sao Paulo, Ribeirao Preto, SP, Brazil.
| |
Collapse
|
4
|
In-Tube Solid-Phase Microextraction Directly Coupled to Mass Spectrometric Systems: A Review. SEPARATIONS 2022. [DOI: 10.3390/separations9120394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Since it was introduced in 1997, in-tube solid-phase microextraction (in-tube SPME), which uses a capillary column as extraction device, has been continuously developed as online microextraction coupled to LC systems (in-tube SPME-LC). In the last decade, new couplings have been evaluated on the basis of state-of-the-art LC instruments, including direct coupling of in-tube SPME to MS/MS systems, without chromatographic separation, for high-throughput analysis. In-tube SPME coupling to MS/MS has been possible thanks to the selectivity of capillary column coatings and MS/MS systems (SRM mode). Different types of capillary columns (wall-coated open-tubular, porous-layer open-tubular, sorbent-packed, porous monolithic rods, or fiber-packed) with selective stationary phases have been developed to increase the sorption capacity and selectivity of in-tube SPME. This review focuses on the in-tube SPME principle, extraction configurations, current advances in direct coupling to MS/MS systems, experimental parameters, coatings, and applications in different areas (food, biological, clinical, and environmental areas) over the last years.
Collapse
|
5
|
Piestansky J, Olesova D, Matuskova M, Cizmarova I, Chalova P, Galba J, Majerova P, Mikus P, Kovac A. Amino acids in inflammatory bowel diseases: Modern diagnostic tools and methodologies. Adv Clin Chem 2022; 107:139-213. [PMID: 35337602 DOI: 10.1016/bs.acc.2021.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Amino acids are crucial building blocks of living organisms. Together with their derivatives, they participate in many intracellular processes to act as hormones, neuromodulators, and neurotransmitters. For several decades amino acids have been studied for their potential as markers of various diseases, including inflammatory bowel diseases. Subsequent improvements in sample pretreatment, separation, and detection methods have enabled the specific and very sensitive determination of these molecules in multicomponent matrices-biological fluids and tissues. The information obtained from targeted amino acid analysis (biomarker-based analytical strategy) can be further used for early diagnostics, to monitor the course of the disease or compliance of the patients. This review will provide an insight into current knowledge about inflammatory bowel diseases, the role of proteinogenic amino acids in intestinal inflammation and modern analytical techniques used in its diagnosis and disease activity monitoring. Current advances in the analysis of amino acids focused on sample pretreatment, separation strategy, or detection methods are highlighted, and their potential in clinical laboratories is discussed. In addition, the latest clinical data obtained from the metabolomic profiling of patients suffering from inflammatory bowel diseases are summarized with a focus on proteinogenic amino acids.
Collapse
Affiliation(s)
- Juraj Piestansky
- Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Bratislava, Slovakia; Toxicological and Antidoping Center, Faculty of Pharmacy, Comenius University in Bratislava, Bratislava, Slovakia
| | - Dominika Olesova
- Institute of Neuroimmunology, Slovak Academy of Sciences, Bratislava, Slovakia
| | - Michaela Matuskova
- Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Bratislava, Slovakia
| | - Ivana Cizmarova
- Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Bratislava, Slovakia
| | - Petra Chalova
- Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Bratislava, Slovakia
| | - Jaroslav Galba
- Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Bratislava, Slovakia
| | - Petra Majerova
- Institute of Neuroimmunology, Slovak Academy of Sciences, Bratislava, Slovakia
| | - Peter Mikus
- Department of Pharmaceutical Analysis and Nuclear Pharmacy, Faculty of Pharmacy, Comenius University in Bratislava, Bratislava, Slovakia; Toxicological and Antidoping Center, Faculty of Pharmacy, Comenius University in Bratislava, Bratislava, Slovakia
| | - Andrej Kovac
- Institute of Neuroimmunology, Slovak Academy of Sciences, Bratislava, Slovakia.
| |
Collapse
|
6
|
Souza ID, Oliveira IGC, Queiroz MEC. Innovative extraction materials for fiber-in-tube solid phase microextraction: A review. Anal Chim Acta 2021; 1165:238110. [PMID: 33975700 DOI: 10.1016/j.aca.2020.11.042] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 11/21/2020] [Accepted: 11/26/2020] [Indexed: 11/18/2022]
Abstract
Fiber-in-tube solid-phase microextraction (fiber-in-tube SPME) with short capillary longitudinally packed with fine fibers as extraction device allows direct coupling to high performance liquid chromatography (HPLC) systems to determine weakly volatile or thermally labile compounds. This technique associates the advantages of miniaturized and analytical on-line systems. Major achievements include the use of different capillaries (fused-silica, copper, stainless steel, polyetheretherketone (PEEK), or poly(tetrafluoroethylene) (PTFE)) that are packed with neat fibers (Zylon®, silk, or Kevlar 29®) or fibers (stainless steel, basalt, or carbon) functionalized with selective coatings (aerogels, ionic liquids (ILs), polymeric ionic liquids (PILs), molecularly imprinted polymers (MIPs), layered double hydroxides (LDHs), or conducting polymer). This review outlines the fundamental theory and the innovative extraction materials for fiber-in-tube SPME-HPLC systems and highlights their main applications in environmental and bioanalyses.
Collapse
Affiliation(s)
- Israel D Souza
- Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil
| | - Igor G C Oliveira
- Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil
| | - Maria Eugênia C Queiroz
- Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP, Brazil.
| |
Collapse
|
7
|
Grecco CF, Souza ID, Queiroz MEC. Novel materials as capillary coatings for in‐tube solid‐phase microextraction for bioanalysis. J Sep Sci 2021; 44:1662-1693. [DOI: 10.1002/jssc.202001070] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 01/11/2021] [Accepted: 01/31/2021] [Indexed: 12/18/2022]
Affiliation(s)
- Caroline Fernandes Grecco
- Faculdade de Filosofia Ciências e Letras de Ribeirão Preto Departamento de Química Universidade de São Paulo São Paulo Brazil
| | - Israel Donizeti Souza
- Faculdade de Filosofia Ciências e Letras de Ribeirão Preto Departamento de Química Universidade de São Paulo São Paulo Brazil
| | - Maria Eugênia Costa Queiroz
- Faculdade de Filosofia Ciências e Letras de Ribeirão Preto Departamento de Química Universidade de São Paulo São Paulo Brazil
| |
Collapse
|
8
|
Kataoka H. In-tube solid-phase microextraction: Current trends and future perspectives. J Chromatogr A 2020; 1636:461787. [PMID: 33359971 DOI: 10.1016/j.chroma.2020.461787] [Citation(s) in RCA: 47] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 12/02/2020] [Accepted: 12/04/2020] [Indexed: 01/01/2023]
Abstract
In-tube solid-phase microextraction (IT-SPME) was developed about 24 years ago as an effective sample preparation technique using an open tubular capillary column as an extraction device. IT-SPME is useful for micro-concentration, automated sample cleanup, and rapid online analysis, and can be used to determine the analytes in complex matrices simple sample processing methods such as direct sample injection or filtration. IT-SPME is usually performed in combination with high-performance liquid chromatography using an online column switching technology, in which the entire process from sample preparation to separation to data analysis is automated using the autosampler. Furthermore, IT-SPME minimizes the use of harmful organic solvents and is simple and labor-saving, making it a sustainable and environmentally friendly green analytical technique. Various operating systems and new sorbent materials have been developed to improve its extraction efficiency by, for example, enhancing its sorption capacity and selectivity. In addition, IT-SPME methods have been widely applied in environmental analysis, food analysis and bioanalysis. This review describes the present state of IT-SPME technology and summarizes its current trends and future perspectives, including method development and strategies to improve extraction efficiency.
Collapse
Affiliation(s)
- Hiroyuki Kataoka
- School of Pharmacy, Shujitsu University, Nishigawara, Okayama 703-8516, Japan.
| |
Collapse
|
9
|
Oliveira IGC, Souza IDD, Nascimento GCD, Del Bel E, Queiroz MEC. In-tube solid-phase microextraction directly coupled to tandem mass spectrometry for anandamide and 2-arachidonoylglycerol determination in rat brain samples from an animal model of Parkinson's disease. J Chromatogr A 2020; 1636:461766. [PMID: 33316562 DOI: 10.1016/j.chroma.2020.461766] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Revised: 11/23/2020] [Accepted: 11/24/2020] [Indexed: 10/22/2022]
Abstract
To evaluate the endocannabinoid system in an animal model of Parkinson's disease, in-tube solid-phase microextraction (in-tube SPME) was directly coupled to a tandem mass spectrometry (MS/MS) system for determination of the endocannabinoids anandamide (AEA) and 2-arachidonoylglycerol (2-AG) in rat brain samples. In-tube SPME-which consisted of a microtube of restricted access material (RAM) with a hydrophilic diol external surface and a hydrophobic octyl inner surface-efficiently excluded (up to 95%) macromolecules from the biological samples and selectively pre-concentrated the analytes. In-tube SPME parameters, such as sample volume, mobile phases, flow rate, and pre-concentration time, were evaluated to improve the extraction efficiency and throughput performance. The selectivity of the in-tube SPME and MS/MS (MRM mode) techniques allowed them to be directly coupled online, which dismissed the need for the chromatographic separation step. The in-tube SPME-MS/MS method was validated and shown to be linear from 6.0 to 30.0 ng mL-1 for AEA and from 10.0 to 100.0 ng mL-1 for 2-AG; the intra- and inter-assay accuracy and precision were lower than 15%. Parallelism between the calibration curves constructed in the matrix and aqueous solution confirmed that there was no matrix effect. The method allowed endogenous concentrations of AEA and 2-AG to be determined in rat brain striatum from unilaterally 6-hydroxydopamine-lesioned animals. The concentrations of these endocannabinoids in striatum ipsilateral and contralateral to the lesion differed significantly (p<0.001).
Collapse
Affiliation(s)
- Igor Gustavo Carvalho Oliveira
- Universidade de São Paulo (USP), Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Departamento de Química, Avenida Bandeirantes, 3900, CEP 14040-901
| | - Israel Donizeti de Souza
- Universidade de São Paulo (USP), Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Departamento de Química, Avenida Bandeirantes, 3900, CEP 14040-901
| | | | - Elaine Del Bel
- Universidade de São Paulo (USP), Faculdade de Odontologia de Ribeirão Preto, Avenida do Café, CEP 14040-904
| | - Maria Eugênia Costa Queiroz
- Universidade de São Paulo (USP), Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Departamento de Química, Avenida Bandeirantes, 3900, CEP 14040-901.
| |
Collapse
|
10
|
Grecco CF, Miranda LFC, Costa Queiroz ME. Aminopropyl hybrid silica monolithic capillary containing mesoporous SBA-15 particles for in-tube SPME-HILIC-MS/MS to determine levodopa, carbidopa, benserazide, dopamine, and 3-O-methyldopa in plasma samples. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105106] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
11
|
Abrantes Dias AS, Amaral Pinto JC, Magalhães M, Mendes VM, Manadas B. Analytical methods to monitor dopamine metabolism in plasma: Moving forward with improved diagnosis and treatment of neurological disorders. J Pharm Biomed Anal 2020; 187:113323. [DOI: 10.1016/j.jpba.2020.113323] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 04/16/2020] [Accepted: 04/17/2020] [Indexed: 12/16/2022]
|
12
|
Manousi N, Tzanavaras PD, Zacharis CK. Bioanalytical HPLC Applications of In-Tube Solid Phase Microextraction: A Two-Decade Overview. Molecules 2020; 25:molecules25092096. [PMID: 32365828 PMCID: PMC7248733 DOI: 10.3390/molecules25092096] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 04/28/2020] [Accepted: 04/29/2020] [Indexed: 12/18/2022] Open
Abstract
In-tube solid phase microextraction is a cutting-edge sample treatment technique offering significant advantages in terms of miniaturization, green character, automation, and preconcentration prior to analysis. During the past years, there has been a considerable increase in the reported publications, as well as in the research groups focusing their activities on this technique. In the present review article, HPLC bioanalytical applications of in-tube SPME are discussed, covering a wide time frame of twenty years of research reports. Instrumental aspects towards the coupling of in-tube SPME and HPLC are also discussed, and detailed information on materials/coatings and applications in biological samples are provided.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, School of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece; (N.M.); (P.D.T.)
| | - Paraskevas D. Tzanavaras
- Laboratory of Analytical Chemistry, School of Chemistry, Faculty of Sciences, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece; (N.M.); (P.D.T.)
| | - Constantinos K. Zacharis
- Laboratory of Pharmaceutical Analysis, Department of Pharmaceutical Technology, School of Pharmacy, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece
- Correspondence: ; Tel.: +30-231-099-7663
| |
Collapse
|
13
|
|
14
|
Recent advances and trends in miniaturized sample preparation techniques. J Sep Sci 2019; 43:202-225. [DOI: 10.1002/jssc.201900776] [Citation(s) in RCA: 82] [Impact Index Per Article: 16.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Revised: 10/16/2019] [Accepted: 10/30/2019] [Indexed: 12/16/2022]
|