1
|
Chen WH, Maheshwaran S, Park YK, Ong HC. Iron-based electrode material composites for electrochemical sensor application in the environment: A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 953:176128. [PMID: 39255942 DOI: 10.1016/j.scitotenv.2024.176128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 08/30/2024] [Accepted: 09/06/2024] [Indexed: 09/12/2024]
Abstract
This review explores the expanding role of electrochemical sensors across diverse domains such as environmental monitoring, medical diagnostics, and food quality assurance. In recent years, iron-based electrocatalysts have emerged as promising candidates for enhancing sensor performance. Notable for their non-toxicity, abundance, catalytic activity, and cost-effectiveness, these materials offer significant advantages. However, further investigation is needed to fully understand how iron-based materials' physical, chemical, and electrical properties influence their catalytic performance in sensor applications. It explores the overview of electrochemical sensor technology, examines the impact of iron-based materials and their characteristics on catalytic activity, and investigates various iron-based materials, their advantages, functionalization, and modification techniques. Additionally, the review investigates the application of iron-based electrode material composites in electrochemical sensors for real sample detections. Ultimately, continued research and development in this area promise to unlock new avenues for using iron-based electrode materials in sensor applications.
Collapse
Affiliation(s)
- Wei-Hsin Chen
- Department of Aeronautics and Astronautics, National Cheng Kung University, Tainan 701, Taiwan; Research Center for Smart Sustainable Circular Economy, Tunghai University, Taichung 407, Taiwan; Department of Mechanical Engineering, National Chin-Yi University of Technology, Taichung 411, Taiwan.
| | - Selvarasu Maheshwaran
- Department of Aeronautics and Astronautics, National Cheng Kung University, Tainan 701, Taiwan.
| | - Young-Kwon Park
- School of Environmental Engineering, University of Seoul, Seoul, 02504, Republic of Korea
| | - Hwai Chyuan Ong
- Department of Engineering, School of Engineering and Technology, Sunway University, Jalan Universiti, Bandar Sunway, 47500 Petaling Jaya, Selangor, Malaysia
| |
Collapse
|
2
|
Cheng Q, Xue C, Abdiryim T, Jamal R. Molecular imprinting electrochemical sensor based on hollow spherical PProDOT-2CH 2OH and chitosan-derived carbon materials for highly sensitive detection of chloramphenicol. JOURNAL OF HAZARDOUS MATERIALS 2024; 478:135615. [PMID: 39181003 DOI: 10.1016/j.jhazmat.2024.135615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 08/18/2024] [Accepted: 08/21/2024] [Indexed: 08/27/2024]
Abstract
The misuse of chloramphenicol (CAP) has jeopardized environmental safety. It is critical to create an effective and sensitive CAP detection technique. In this paper, a composite of chitosan (CS)-derived carbon material modified hollow spherical hydroxylated poly(3,4-propylenedioxythiophene) (PProDOT-2CH2OH) was designed, which innovatively used o-phenylenediamine and p-aminobenzoic acid as bi-functional monomers to prepare molecular imprinting polymer (MIP) sensors for highly sensitive analysis and determination of CAP. It was found that the hollow spherical structure of PProDOT-2CH2OH significantly enhanced the rapid electron migration. When combined with the CS-derived carbon material, which has multi-functional sites, it improved the electrical activity and stability of the sensor. It also provided more active centers for the MIP layer to specifically recognize CAP. Therefore, this MIP sensor had a wide linear response (0.0001 ∼ 125 μM), a low limit of detection (LOD, 6.6 pM), excellent selectivity and stability. In addition, studies showed that the sensor has potential practical value. ENVIRONMENTAL IMPLICATION: Chloramphenicol (CAP) is one of the most widely used antibiotics with the highest dosage due to its low price and broad-spectrum antimicrobial properties. Due to its incomplete metabolism in living organisms and its difficulty in degrading in the environment, contamination caused by it can pose a threat to public health. In this study, a novel molecularly imprinted sensor (MIP/PC2C1/GCE) was designed to provide a new idea for rapid and precise removal of CAP by adsorption. The detection of CAP in pharmaceutical, water quality, and food fields was realized.
Collapse
Affiliation(s)
- Qian Cheng
- College of Chemistry, Xinjiang University, Urumqi 830017, Xinjiang, PR China; State Key Laboratory of Chemistry and Utilization of Carbon Based Energy Resources, Xinjiang University, Urumqi 830017, Xinjiang, PR China
| | - Cong Xue
- College of Chemistry, Xinjiang University, Urumqi 830017, Xinjiang, PR China; State Key Laboratory of Chemistry and Utilization of Carbon Based Energy Resources, Xinjiang University, Urumqi 830017, Xinjiang, PR China
| | - Tursun Abdiryim
- College of Chemistry, Xinjiang University, Urumqi 830017, Xinjiang, PR China; State Key Laboratory of Chemistry and Utilization of Carbon Based Energy Resources, Xinjiang University, Urumqi 830017, Xinjiang, PR China.
| | - Ruxangul Jamal
- School of Chemical Engineering and Technology, Xinjiang University, Urumqi 830017, Xinjiang, PR China; State Key Laboratory of Chemistry and Utilization of Carbon Based Energy Resources, Xinjiang University, Urumqi 830017, Xinjiang, PR China.
| |
Collapse
|
3
|
Wu H, Wen Q, Luan X, Yang W, Guo L, Wei G. Facile Synthesis of Fe-Doped, Algae Residue-Derived Carbon Aerogels for Electrochemical Dopamine Biosensors. SENSORS (BASEL, SWITZERLAND) 2024; 24:2787. [PMID: 38732893 PMCID: PMC11086316 DOI: 10.3390/s24092787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 04/20/2024] [Accepted: 04/24/2024] [Indexed: 05/13/2024]
Abstract
An abnormal level of dopamine (DA), a kind of neurotransmitter, correlates with a series of diseases, including Parkinson's disease, Willis-Ekbom disease, attention deficit hyperactivity disorder, and schizophrenia. Hence, it is imperative to achieve a precise, rapid detection method in clinical medicine. In this study, we synthesized nanocomposite carbon aerogels (CAs) doped with iron and iron carbide, based on algae residue-derived biomass materials, using Fe(NO3)3 as the iron source. The modified glassy carbon electrode (GCE) for DA detection, denoted as CAs-Fe/GCE, was prepared through surface modification with this composite material. X-ray photoelectron spectroscopy and X-ray diffraction characterization confirmed the successful doping of iron into the as-prepared CAs. Additionally, the electrochemical behavior of DA on the modified electrode surface was investigated and the results demonstrate that the addition of the CAs-Fe promoted the electron transfer rate, thereby enhancing their sensing performance. The fabricated electrochemical DA biosensor exhibits an accurate detection of DA in the concentration within the range of 0.01~200 µM, with a detection limit of 0.0033 µM. Furthermore, the proposed biosensor is validated in real samples, showing its high applicability for the detection of DA in beverages.
Collapse
Affiliation(s)
- Hao Wu
- Institute of Biomedical Engineering, College of Life Science, Qingdao University, Qingdao 266071, China; (H.W.); (Q.W.); (W.Y.)
| | - Qin Wen
- Institute of Biomedical Engineering, College of Life Science, Qingdao University, Qingdao 266071, China; (H.W.); (Q.W.); (W.Y.)
| | - Xin Luan
- College of Chemistry and Chemical Engineering, Qingdao University, Qingdao 266071, China;
| | - Weiwei Yang
- Institute of Biomedical Engineering, College of Life Science, Qingdao University, Qingdao 266071, China; (H.W.); (Q.W.); (W.Y.)
| | - Lei Guo
- Institute of Biomedical Engineering, College of Life Science, Qingdao University, Qingdao 266071, China; (H.W.); (Q.W.); (W.Y.)
| | - Gang Wei
- College of Chemistry and Chemical Engineering, Qingdao University, Qingdao 266071, China;
| |
Collapse
|
4
|
Yu H, Hu M, Wang X, Wang X, Xun L, Liu H. Rapid Detection of the Anti-Tumor Drug Etoposide in Biological Samples by Using a Nanoporous-Gold-Based Electrochemical Sensor. Molecules 2024; 29:1060. [PMID: 38474572 DOI: 10.3390/molecules29051060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 02/21/2024] [Accepted: 02/25/2024] [Indexed: 03/14/2024] Open
Abstract
Monitoring etoposide is important due to its wide usage in anti-tumor therapy; however, the commonly used HPLC method is expensive and often requires complicated extraction and detection procedures. Electrochemical analysis has great application prospects because of its rapid response and high specificity, sensitivity, and efficiency with low cost and high convenience. In this study, we constructed a nanoporous gold (NPG)-modified GCE for the detection of etoposide. The electrochemical oxidation of etoposide by NPG caused a sensitive current peak at +0.27 V with good reproductivity in 50 mM of phosphate buffer (pH 7.4). The relationship between etoposide concentration and peak current was linear in the range between 0.1 and 20 μM and between 20 and 150 μM, with a detection sensitivity of 681.8 μA mM-1 cm-2 and 197.2 μA mM-1 cm-2, respectively, and a limit of detection (LOD) reaching 20 nM. The electrode had a good anti-interference ability to several common anions and cations. Spiked recovery tests in serum, urine, and fermentation broth verified the excellent performance of the sensor in terms of sensitivity, reproducibility, and specificity. This may provide a promising tool for the detection of etoposide in biological samples.
Collapse
Affiliation(s)
- Huiyuan Yu
- State Key Laboratory of Microbial Technology, Shandong University, 72 Binhai Road, Qingdao 266237, China
| | - Mengjie Hu
- State Key Laboratory of Microbial Technology, Shandong University, 72 Binhai Road, Qingdao 266237, China
| | - Xiaolei Wang
- State Key Laboratory of Microbial Technology, Shandong University, 72 Binhai Road, Qingdao 266237, China
| | - Xia Wang
- State Key Laboratory of Microbial Technology, Shandong University, 72 Binhai Road, Qingdao 266237, China
| | - Luying Xun
- State Key Laboratory of Microbial Technology, Shandong University, 72 Binhai Road, Qingdao 266237, China
- School of Molecular Biosciences, Washington State University, Pullman, WA 99164-7520, USA
| | - Honglei Liu
- State Key Laboratory of Microbial Technology, Shandong University, 72 Binhai Road, Qingdao 266237, China
| |
Collapse
|
5
|
Alfonso-González JG, Granja-Banguera CP, Morales-Morales JA, Dector A. A Facile Glycerol-Assisted Synthesis of Low-Cu 2+-Doped CoFe 2O 4 for Electrochemical Sensing of Acetaminophen. BIOSENSORS 2023; 13:997. [PMID: 38131757 PMCID: PMC10741980 DOI: 10.3390/bios13120997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/26/2023] [Revised: 11/07/2023] [Accepted: 11/13/2023] [Indexed: 12/23/2023]
Abstract
This work devised a simple glycerol-assisted synthesis of a low-Cu2+-doped CoFe2O4 and the electrochemical detection of acetaminophen (AC). During the synthesis, several polyalcohols were tested, indicating the efficiency of glycerin as a cosolvent, aiding in the creation of electrode-modifier nanomaterials. A duration of standing time (eight hours) before calcination produces a decrease in the secondary phase of hematite. The synthesized material was used as an electrode material in the detection of AC. In acidic conditions (pH 2.5), the limit of detection (LOD) was 99.4 nM, while the limit of quantification (LOQ) was found to be (331 nM). The relative standard deviation (RSD), 3.31%, was computed. The enhanced electrocatalytic activity of a low-Cu2+-doped CoFe2O4-modified electrode Cu0.13Co0.87Fe2O4/GCE corresponds extremely well with its resistance Rct, which was determined using the electrochemical impedance spectroscopy (EIS) technique and defined its electron transfer capacity. The possibility of a low-Cu2+-doped CoFe2O4 for the electrochemical sensing of AC in human urine samples was studied. The recovery rates ranging from 96.5 to 101.0% were obtained. These findings suggested that the Cu0.13Co0.87Fe2O4/GCE sensor has outstanding practicability and could be utilized to detect AC content in real complex biological samples.
Collapse
Affiliation(s)
- José Guillermo Alfonso-González
- Grupo de Investigación en Química y Biotecnología (QUIBIO), Facultad de Ciencias Básicas, Campus Pampalinda, Universidad Santiago de Cali, Cali 760035, Colombia; (J.G.A.-G.); (C.P.G.-B.)
| | - Claudia Patricia Granja-Banguera
- Grupo de Investigación en Química y Biotecnología (QUIBIO), Facultad de Ciencias Básicas, Campus Pampalinda, Universidad Santiago de Cali, Cali 760035, Colombia; (J.G.A.-G.); (C.P.G.-B.)
| | - Jimmy Alexander Morales-Morales
- Grupo de Investigación en Química y Biotecnología (QUIBIO), Facultad de Ciencias Básicas, Campus Pampalinda, Universidad Santiago de Cali, Cali 760035, Colombia; (J.G.A.-G.); (C.P.G.-B.)
| | - Andrés Dector
- CONAHCYT (Consejo Nacional de Humanidades, Ciencias y Tecnologías), Universidad Tecnológica de San Juan del Río, San Juan del Río 76800, Querétaro, Mexico;
| |
Collapse
|