1
|
Ruiz-Romero V, Jorba-Garcia A, Camps-Font O, Figueiredo R, Valmaseda-Castellón E. Accuracy of dynamic computer-assisted implant surgery in fully edentulous patients: An in vitro study. J Dent 2024; 149:105290. [PMID: 39106900 DOI: 10.1016/j.jdent.2024.105290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Revised: 07/12/2024] [Accepted: 08/03/2024] [Indexed: 08/09/2024] Open
Abstract
OBJECTIVES To compare miniscrew versus bone tracing registration methods on dental implant placement accuracy and time efficiency in edentulous jaws using a dynamic computer-assisted implant surgery (d-CAIS) system. METHODS Twelve fully edentulous maxillary models were allocated into two groups: miniscrew tracing (MST) group, where registration was performed by tracing four miniscrews; and bone tracing (BT) group, where registration was conducted by tracing maxillary bone fiducial landmarks. Six implants were placed on each model using the X-Guide® d-CAIS system. Pre- and postoperative cone-beam computed tomography (CBCT) scans were superimposed to evaluate implant placement accuracy. The time required for registration and the overall surgery time were also recorded. RESULTS Thirty-six implants were placed in each group. The MST group showed significantly lower mean angulation deviations (mean difference (MD): -3.33°; 95 % confidence interval (CI): -6.56 to -0.09); p = 0.044), 3D platform deviations (MD: -1.01 mm; 95 % CI: -1.74 to -0.29; p = 0.006), 2D platform deviations (MD: -0.97 mm; 95 % CI: -1.71 to -0.23; p = 0.010), and 3D apex deviations (MD: -1.18 mm; 95 % CI: -1.92 to -0.44; p = 0.002) versus the BT group. The overall surgery time was similar for both groups (MD: 6.10 min.; 95 % CI: -0.31 to 12.51; p = 0.06), though bone tracing required significantly more time compared with miniscrew registration (MD: 4.79 min.; 95 % CI: 2.96 to 6.62; p < 0.05). CONCLUSIONS Registration with MST increases the accuracy of implant placement with a d-CAIS system in edentulous jaws compared with the BT method, and slightly reduces the overall surgery time. CLINICAL SIGNIFICANCE Miniscrew tracing registration improves implant placement accuracy in comparison with bone tracing registration.
Collapse
Affiliation(s)
- Víctor Ruiz-Romero
- DDS, MS. Master of Oral Surgery and Implantology, Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona Spain
| | - Adrià Jorba-Garcia
- DDS, MS. Master of Oral Surgery and Implantology, Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona Spain
| | - Octavi Camps-Font
- DDS, MS, PhD. Associate Professor of Oral Surgery, Faculty of Medicine and Health Sciences, University of Barcelona (Spain). Researcher at the IDIBELL Institute, Barcelona Spain
| | - Rui Figueiredo
- DDS, MS, PhD. Associate Professor of Oral Surgery, Faculty of Medicine and Health Sciences, University of Barcelona (Spain). Researcher at the IDIBELL Institute, Barcelona Spain.
| | - Eduard Valmaseda-Castellón
- DDS, MS, PhD. Chairman of Oral Surgery. Faculty of Medicine and Health Sciences of the University of Barcelona (Spain), Researcher at the IDIBELL Institute, Barcelona Spain
| |
Collapse
|
2
|
Pellegrino G, Zaccheroni Z, Lizio G. Immediate full-arch fixed rehabilitation of a narrow mandible with newly conceived connection system implants: A case report. JOURNAL OF ADVANCED PERIODONTOLOGY & IMPLANT DENTISTRY 2024; 16:64-71. [PMID: 39027210 PMCID: PMC11252157 DOI: 10.34172/japid.2024.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2023] [Accepted: 04/27/2024] [Indexed: 07/20/2024]
Abstract
Rehabilitating thin jaws without reconstructive surgery entails using narrow implants. The proposed treatment adopted an innovative implant system, allowing the mini-screws to be parallel and immediately loaded. A mandible, wearing an overdenture, was functionalized contextually to the residual dental extraction and the placement of six 2.4-mm thick one-piece implants. Low-profile intermediate abutments, the LEMs, able to rotate over the spherical heads of the fixtures, were connected after suturing, oriented, and blocked in a mutual parallel position. The copings, engaging with a tapered juncture of the LEMs, resulted in their alignment to be intraorally wedged together. The provisional superstructure enclosed the copings and was immediately connected to the implants, and the definitive prosthesis was delivered after three months. No clinical signs of peri-implantitis or radiographically evident bone loss were recorded after a two-year follow-up without any prosthetic complication. No cases have been published regarding mini-implants bearing fixed prosthesis rehabilitation.
Collapse
Affiliation(s)
- Gerardo Pellegrino
- Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| | | | | |
Collapse
|
3
|
Sun Y, Xu C, Wang N, Wu Y, Liu Y, Fan S, Wang F. Virtual pterygoid implant planning in maxillary atrophic patients: prosthetic-driven planning and evaluation. Int J Implant Dent 2023; 9:9. [PMID: 36971973 PMCID: PMC10043104 DOI: 10.1186/s40729-023-00472-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Accepted: 03/13/2023] [Indexed: 03/29/2023] Open
Abstract
PURPOSE The study aims to use cone beam computed tomography (CBCT) to (1) define the virtual valid length of pterygoid implants in maxillary atrophic patients from the prosthetic prioritized driven position and (2) measure the implant length engaged in the pterygoid process according to the HU difference of the pterygoid maxillary junction. MATERIALS AND METHODS Virtual pterygoid implants were planned with CBCT of maxillary atrophic patients in the software. The entry and angulation of the implant were planned according to the prosthetic prioritized driven position in the 3D reconstruction image. The planned implant length and the valid length defined as the implant between the pterygoid maxillary junction and pterygoid fossa were recorded. The relationship between the implant and sinus cavity was also evaluated. RESULTS A total of 120 CBCT samples were enrolled and virtually planned. The mean age of the patients was 56.2 ± 13.2 years. One hundred and sixteen samples could successfully place virtual implants according to the criterion. The mean implant length and mean implant length beyond the pterygoid maxillary junction were 16.3 ± 4.2 mm (range, 11.5-18 mm) and 7.1 ± 3.3 mm (range, 1.5-11.4 mm), respectively. Ninety percent of virtually planned implants had a close relationship with the sinus cavity, and implants exhibited longer lengths when they had no relation with the sinus. CONCLUSION From a prosthetic prioritized driven position with fixed entry and angulation, pterygoid implants achieve adequate bone anchorage length beyond the pterygoid maxillary junction. Due to the individual anatomy and the volume of the maxillary sinus, the implants presented a different positional relationship with the maxillary sinus.
Collapse
Affiliation(s)
- Yuanyuan Sun
- Department of Oral Cell Biology, Academic Center for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, Netherlands
- Department of Second Dental Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, No. 280, Mohe Road, Baoshan District, Shanghai, 201900, China
| | - Chunfeng Xu
- Department of Oral Cell Biology, Academic Center for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, Netherlands
| | - Ningtao Wang
- Department of Second Dental Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, No. 280, Mohe Road, Baoshan District, Shanghai, 201900, China
| | - Yiqun Wu
- Department of Second Dental Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, No. 280, Mohe Road, Baoshan District, Shanghai, 201900, China
| | - Yuelian Liu
- Department of Oral Cell Biology, Academic Center for Dentistry Amsterdam (ACTA), University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, Netherlands
| | - Shengchi Fan
- Department of Second Dental Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, No. 280, Mohe Road, Baoshan District, Shanghai, 201900, China.
- Department of Oral and Maxillofacial Surgery, University Medical Center of the Johannes-Gutenberg University, Augustusplatz 2, 55131, Mainz, Germany.
| | - Feng Wang
- Department of Second Dental Center, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, College of Stomatology, Shanghai Jiao Tong University, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Shanghai Key Laboratory of Stomatology, Shanghai Research Institute of Stomatology, No. 280, Mohe Road, Baoshan District, Shanghai, 201900, China.
| |
Collapse
|
4
|
Scaringi R, Nannelli M, Franchina A, Lizio G, Stefanelli LV, Pagliarulo M, De Angelis F, Pellegrino G. Full Zirconia Implant-Born Prosthetic Rehabilitation with CAD/CAM Technology after Accurate Digital Planning. A Case Report. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2021; 18:ijerph18157998. [PMID: 34360288 PMCID: PMC8345593 DOI: 10.3390/ijerph18157998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Revised: 07/21/2021] [Accepted: 07/24/2021] [Indexed: 11/17/2022]
Abstract
CAD/CAM technology can enhance the dentistry application of ceramic materials that meet the more relevant biocompatibility and aesthetics demands. In implant-borne prosthesis rehabilitation, yttria-stabilized zirconia appeared to be a valid alternative to metal-alloys and titanium, with comparable mechanical properties and even better interaction with bone and soft tissues. The improvement of monolithic CAD/CAM manufacturing allows for a reliable, predictable, and rapid workflow that can correspond to a holistic treatment philosophy associated with zirconia fixtures. This reported clinical case highlights the advantages of this approach in resolving particularly functionally and aesthetically complex situations. A 40-year-old patient with permanent canine impaction and the persistence of a deciduous tooth compromised by caries was successfully rehabilitated with the surgical removal of the enclosed tooth, the seating of a mono-phase zirconia implant after the deciduous extraction and its loading with a zirconia single crown, without any clinical or radiographical alteration up to seven years follow-up.
Collapse
Affiliation(s)
| | | | - Alessio Franchina
- Private Practice, Periodontal and Dental Implant Surgery, 36100 Vicenza, Italy;
| | - Giuseppe Lizio
- Oral Surgery Unit, Department of Biomedical and Neuromotor Sciences, University of Bologna, Via San Vitale 59, 40125 Bologna, Italy
- Correspondence:
| | - Luigi V. Stefanelli
- Private Practice, Periodontal and Dental Implant Surgery, 00145 Roma, Italy;
| | - Michele Pagliarulo
- Faculty of Dental Medicine, University of Plovdiv, 4000 Plovdiv, Bulgaria;
| | - Francesca De Angelis
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, 00185 Rome, Italy;
| | - Gerardo Pellegrino
- Researcher Oral Surgery Unit, Department of Biomedical and Neuromotor Sciences, University of Bologna, Via San Vitale 59, 40125 Bologna, Italy;
| |
Collapse
|
5
|
Dynamic Navigated "Sandwich" Technique: A Novel Surgical Approach for Safe Osteotomies in the Rehabilitation of an Atrophic Posterior Mandible: A Case Report. Methods Protoc 2021; 4:mps4020034. [PMID: 34065701 PMCID: PMC8162557 DOI: 10.3390/mps4020034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 05/10/2021] [Accepted: 05/12/2021] [Indexed: 11/26/2022] Open
Abstract
A 56-year-old female patient with vertical atrophy of the right posterior mandible was treated adopting an interpositional bone block approach using a cancellous heterologous bone block. Osteotomies of the patient’s mandible were performed with the help of dynamic computer-assisted surgery using virtual anatomical patient information obtained from a cone beam computed tomography (CBCT). The use of the dynamic computer-assisted surgery allowed authors to perform the horizontal osteotomy line as planned preoperatively on the CBCT virtual reconstruction, trying to minimize the risks of the inlay technique. No neurological complications were observed after surgery. The inlay technique could benefit from the aid of dynamic navigation technologies in posterior atrophic mandibles, increasing the reproducibility of the technique. A likely safer method for performing osteotomies with the “sandwich” technique in the posterior atrophic mandible is reported.
Collapse
|