1
|
Zheng ALT, Teo EYL, Yiu PH, Boonyuen S, Andou Y. Emerging trends in functional materials for electrochemical sensors in nicotine determination. ANAL SCI 2024; 40:1933-1946. [PMID: 39030465 DOI: 10.1007/s44211-024-00629-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Accepted: 07/07/2024] [Indexed: 07/21/2024]
Abstract
In the past year, there has been significant progress in the utilization of electrochemical strategies for the determination of harmful substances. Among those, the electrochemical determination of nicotine (NIC) has continued to be of significant interest ascribed to the global health concern of e-cigarette products, nowadays. Electrochemical sensors have become promising tools for the detection of NIC ascribed to their high sensitivity, selectivity, and ease of use. This review article provides a concise overview of the advanced developments in electrochemical sensors for NIC detection using modified functional materials such as carbon-based materials, metal-organic frameworks (MOF), MXene, polymer, and metallic based modifiers. The sensitivity of electrochemical sensors can be improved by modifying them with these conductive materials ascribed to their physical and chemical properties. The review also addresses the challenges and future perspectives in the field, including sensitivity and selectivity improvements, stability and reproducibility issues, integration with data analysis techniques, and emerging trends. In conclusion, this review article may be of interest to researchers intending to delve into the development of functional electrochemical sensors in future studies.
Collapse
Affiliation(s)
- Alvin Lim Teik Zheng
- Institute of Ecoscience Borneo, Universiti Putra Malaysia Bintulu Campus, Bintulu, 97008, Sarawak, Malaysia.
| | - Ellie Yi Lih Teo
- Department of Science and Technology, Faculty of Humanities, Management and Science, Universiti Putra Malaysia Bintulu Campus, Bintulu, 97008, Sarawak, Malaysia
| | - Pang Hung Yiu
- Department of Science and Technology, Faculty of Humanities, Management and Science, Universiti Putra Malaysia Bintulu Campus, Bintulu, 97008, Sarawak, Malaysia
| | - Supakorn Boonyuen
- Department of Chemistry, Faculty of Science and Technology, Thammasat University, Pathumthani, 12120, Thailand
| | - Yoshito Andou
- Graduate School of Life Sciences and Systems Engineering, Kyushu Institute of Technology, Fukuoka, 808-0196, Japan
- Collaborative Research Centre for Green Materials On Environmental Technology, Kyushu Institute of Technology, Fukuoka, 808-0196, Japan
| |
Collapse
|
2
|
Alsoghier HM, Abd-Elsabour M, Alhamzani AG, Abou-Krisha MM, Assaf HF. Real samples sensitive dopamine sensor based on poly 1,3-benzothiazol-2-yl((4-carboxlicphenyl)hydrazono)acetonitrile on a glassy carbon electrode. Sci Rep 2024; 14:16601. [PMID: 39025924 PMCID: PMC11258363 DOI: 10.1038/s41598-024-65192-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Accepted: 06/18/2024] [Indexed: 07/20/2024] Open
Abstract
Herein, a novel electrochemical sensor that was used for the first time for sensitive and selective detection of dopamine (DA) was fabricated. The new sensor is based on the decoration of the glassy carbon electrode surface (GC) with a polymer film of 1,3-Benzothiazol-2-yl((4-carboxlicphenyl)hydrazono)) acetonitrile (poly(BTCA). The prepared (poly(BTCA) was examined by using different techniques such as 1H NMR, 13C NMR, FTIR, and UV-visible spectroscopy. The electrochemical investigations of DA were assessed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The results obtained showed that the modifier increased the electrocatalytic efficiency with a noticeable increase in the oxidation peak current of DA in 0.1 M phosphate buffer solution (PBS) at an optimum pH of 7.0 and scan rate of 200 mV/s when compared to unmodified GC. The new sensor displays a good performance for detecting DA with a limit of detection (LOD 3σ), and limit of quantification (LOQ 10σ) are 0.28 nM and 94 nM respectively. The peak current of DA is linearly proportional to the concentration in the range from 0.1 to 10.0 µM. Additionally, the fabricated electrode showed sufficient reproducibility, stability, and selectivity for DA detection in the presence of different interferents. The proposed poly(BTCA)/GCE sensor was effectively applied to detect DA in the biological samples.
Collapse
Affiliation(s)
- Hesham M Alsoghier
- Chemistry Department, Faculty of Science, South Valley University, Qena, 83523, Egypt.
| | - Mohamed Abd-Elsabour
- Chemistry Department, Faculty of Science, Luxor University, Luxor, 85951, Egypt.
| | - Abdulrahman G Alhamzani
- Chemistry Department, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), 11623, Riyadh, Saudi Arabia
| | - Mortaga M Abou-Krisha
- Chemistry Department, Faculty of Science, South Valley University, Qena, 83523, Egypt
- Chemistry Department, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), 11623, Riyadh, Saudi Arabia
| | - Hytham F Assaf
- Chemistry Department, Faculty of Science, South Valley University, Qena, 83523, Egypt
| |
Collapse
|
3
|
Abd-Elsabour M, Abou-Krisha MM, Kenawy SH, Yousef TA. A Novel Electrochemical Sensor Based on an Environmentally Friendly Synthesis of Magnetic Chitosan Nanocomposite Carbon Paste Electrode for the Determination of Diclofenac to Control Inflammation. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:1079. [PMID: 36985972 PMCID: PMC10058736 DOI: 10.3390/nano13061079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 02/25/2023] [Accepted: 02/28/2023] [Indexed: 06/18/2023]
Abstract
A simple and eco-friendly electrochemical sensor for the anti-inflammatory diclofenac (DIC) was developed in a chitosan nanocomposite carbon paste electrode (M-Chs NC/CPE). The M-Chs NC/CPE was characterized with FTIR, XRD, SEM, and TEM for the size, surface area, and morphology. The produced electrode showed a high electrocatalytic activity to use the DIC in 0.1 M of the BR buffer (pH 3.0). The effect of scanning speed and pH on the DIC oxidation peak suggests that the DIC electrode process has a typical diffusion characteristic with two electrons and two protons. Furthermore, the peak current linearly proportional to the DIC concentration ranged from 0.025 M to 4.0 M with the correlation coefficient (r2). The sensitivity, limit of detection (LOD; 3σ), and the limit of quantification (LOQ; 10σ) were 0.993, 9.6 µA/µM cm2, 0.007 µM, and 0.024 µM, respectively. In the end, the proposed sensor enables the reliable and sensitive detection of DIC in biological and pharmaceutical samples.
Collapse
Affiliation(s)
- Mohamed Abd-Elsabour
- Chemistry Department, Faculty of Science, South Valley University, Qena 83523, Egypt
| | - Mortaga M. Abou-Krisha
- Chemistry Department, Faculty of Science, South Valley University, Qena 83523, Egypt
- Chemistry Department, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11623, Saudi Arabia
| | - Sayed H. Kenawy
- Chemistry Department, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11623, Saudi Arabia
- Refractories, Ceramics and Building Materials Department, National Research Centre, El-Buhouth St., Dokki, Giza 12622, Egypt
| | - Tarek A. Yousef
- Chemistry Department, College of Science, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh 11623, Saudi Arabia
- Mansoura Laboratory, Toxic and Narcotic Drug, Forensic Medicine Department, Medicolegal Organization, Ministry of Justice, Cairo 11435, Egypt
| |
Collapse
|
4
|
Magesh V, Sundramoorthy AK, Ganapathy D, Atchudan R, Arya S, Alshgari RA, Aljuwayid AM. Palladium Hydroxide (Pearlman's Catalyst) Doped MXene (Ti 3C 2Tx) Composite Modified Electrode for Selective Detection of Nicotine in Human Sweat. BIOSENSORS 2022; 13:bios13010054. [PMID: 36671889 PMCID: PMC9856038 DOI: 10.3390/bios13010054] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 12/22/2022] [Accepted: 12/24/2022] [Indexed: 05/27/2023]
Abstract
High concentrations of nicotine (40 to 60 mg) are more dangerous for adults who weigh about 70 kg. Herein, we developed an electrochemical transducer using an MXene (Ti3C2Tx)/palladium hydroxide-supported carbon (Pearlman's catalyst) composite (MXene/Pd(OH)2/C) for the identification of nicotine levels in human sweat. Firstly, the MXene was doped with Pd(OH)2/C (PHC) by mechanical grinding followed by an ultrasonication process to obtain the MXene/PHC composite. Secondly, XRD, Raman, FE-SEM, EDS and E-mapping analysis were utilized to confirm the successful formation of MXene/PHC composite. Using MXene/PHC composite dispersion, an MXene/PHC composite-modified glassy carbon electrode (MXene/PHC/GCE) was prepared, which showed high sensitivity as well as selectivity towards nicotine (300 µM NIC) oxidation in 0.1 M phosphate buffer (pH = 7.4) by cyclic voltammetry (CV) and amperometry. The MXene/PHC/GCE had reduced the over potential of nicotine oxidation (about 200 mV) and also enhanced the oxidation peak current (8.9 µA) compared to bare/GCE (2.1 µA) and MXene/GCE (5.5 µA). Moreover, the optimized experimental condition was used for the quantification of NIC from 0.25 µM to 37.5 µM. The limit of detection (LOD) and sensitivity were 27 nM and 0.286 µA µM-1 cm2, respectively. The MXene/PHC/GCE was also tested in the presence of Na+, Mg2+, Ca2+, hydrogen peroxide, acetic acid, ascorbic acid, dopamine and glucose. These molecules were not interfered during NIC analysis, which indicated the good selectivity of the MXene/PHC/GCE sensor. In addition, electrochemical determination of NIC was successfully carried out in the human sweat samples collected from a tobacco smoker. The recovery percentage of NIC in the sweat sample was 97%. Finally, we concluded that the MXene/PHC composite-based sensor can be prepared for the accurate determination of NIC with high sensitivity, selectivity and stability in human sweat samples.
Collapse
Affiliation(s)
- Vasanth Magesh
- Centre for Nano-Biosensors, Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Poonamallee High Road, Velappanchavadi, Chennai 600077, Tamil Nadu, India
| | - Ashok K. Sundramoorthy
- Centre for Nano-Biosensors, Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Poonamallee High Road, Velappanchavadi, Chennai 600077, Tamil Nadu, India
| | - Dhanraj Ganapathy
- Centre for Nano-Biosensors, Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Poonamallee High Road, Velappanchavadi, Chennai 600077, Tamil Nadu, India
| | - Raji Atchudan
- School of Chemical Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea
| | - Sandeep Arya
- Department of Physics, University of Jammu, Jammu 180006, Jammu and Kashmir, India
| | - Razan A. Alshgari
- Department of Chemistry, College of Science, King Saud University, Riyadh 11451, Saudi Arabia
| | - Ahmed Muteb Aljuwayid
- Department of Chemistry, College of Science, King Saud University, Riyadh 11451, Saudi Arabia
| |
Collapse
|