1
|
Konoike F, Taniguchi M, Yamamoto S. Integrated continuous downstream process of monoclonal antibody developed by converting the batch platform process based on the process characterization. Biotechnol Bioeng 2024; 121:2269-2277. [PMID: 37691165 DOI: 10.1002/bit.28537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 08/06/2023] [Accepted: 08/16/2023] [Indexed: 09/12/2023]
Abstract
A continuous downstream process of monoclonal antibody was developed based on the process characterization. Periodic-counter current chromatography (PCCC) with two protein A columns was used for the capture step. For low pH virus inactivation (VI), a batch reactor was employed, which can work as a surge (buffer) tank. Flow-through chromatography (FTC) with two connected columns of different separation modes (anion-mixed mode and cation exchange) was designed as a polish step. After 24 h PCCC run, the collected pool was processed for VI. After adjusting pH and electric conductivity, the solution was fed to the two connected FTC columns for 24 h. Virus filter was also connected to the exit of the connected-column. PCCC and FTC were run in parallel. Six runs of different feed rates (0.5-10 L/day) and feed concentrations (1-3.2 g/L) were performed with protein A columns of 1-5 mL and FTC columns of 3-10 mL. The largest run (feed rate 10 L/day, feed concentration 2 g/L) was carried out at a GMP facility with 15 mL protein A columns and 100 mL FTC columns. Good recovery and purity values were obtained for all runs. The process was found to be flexible and stable for feed fluctuations. Only three surge or pool tanks were needed in addition to the final product pool tank.
Collapse
Affiliation(s)
- Fuminori Konoike
- Manufacturing Technology Association of Biologics, Shin-kawa, Chuo-ku, Japan
| | - Masatoshi Taniguchi
- Manufacturing Technology Association of Biologics, Shin-kawa, Chuo-ku, Japan
| | - Shuichi Yamamoto
- Manufacturing Technology Association of Biologics, Shin-kawa, Chuo-ku, Japan
- Biomedical Engineering Center (YUBEC), Graduate School of Science and Technology for Innovation, Yamaguchi University, Ube, Japan
| |
Collapse
|
2
|
Christie L, Rutherford S, Palmer DS, Baker MJ, Butler HJ. Bioprocess monitoring applications of an innovative ATR-FTIR spectroscopy platform. Front Bioeng Biotechnol 2024; 12:1349473. [PMID: 38863496 PMCID: PMC11165065 DOI: 10.3389/fbioe.2024.1349473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Accepted: 05/09/2024] [Indexed: 06/13/2024] Open
Abstract
Pharmaceutical manufacturing is reliant upon bioprocessing approaches to generate the range of therapeutic products that are available today. The high cost of production, susceptibility to process failure, and requirement to achieve consistent, high-quality product means that process monitoring is paramount during manufacturing. Process analytic technologies (PAT) are key to ensuring high quality product is produced at all stages of development. Spectroscopy-based technologies are well suited as PAT approaches as they are non-destructive and require minimum sample preparation. This study explored the use of a novel attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy platform, which utilises disposable internal reflection elements (IREs), as a method of upstream bioprocess monitoring. The platform was used to characterise organism health and to quantify cellular metabolites in growth media using quantification models to predict glucose and lactic acid levels both singularly and combined. Separation of the healthy and nutrient deficient cells within PC space was clearly apparent, indicating this technique could be used to characterise these classes. For the metabolite quantification, the binary models yielded R 2 values of 0.969 for glucose, 0.976 for lactic acid. When quantifying the metabolites in tandem using a multi-output partial least squares model, the corresponding R 2 value was 0.980. This initial study highlights the suitability of the platform for bioprocess monitoring and paves the way for future in-line developments.
Collapse
Affiliation(s)
- Loren Christie
- Dxcover Ltd., Glasgow, United Kingdom
- Pure and Applied Chemistry, University of Strathclyde, Glasgow, United Kingdom
| | - Samantha Rutherford
- Pure and Applied Chemistry, University of Strathclyde, Glasgow, United Kingdom
| | - David S. Palmer
- Dxcover Ltd., Glasgow, United Kingdom
- Pure and Applied Chemistry, University of Strathclyde, Glasgow, United Kingdom
| | - Matthew J. Baker
- Dxcover Ltd., Glasgow, United Kingdom
- School of Medicine and Dentistry, University of Central Lancashire, Preston, United Kingdom
| | | |
Collapse
|
3
|
Feng H, Dunn ZD, Kargupta R, Desai J, Phuangthong C, Venkata T, Appiah-Amponsah E, Patel B. Pioneering Just-in-Time (JIT) Strategy for Accelerating Raman Method Development and Implementation for Biologic Continuous Manufacturing. Anal Chem 2024. [PMID: 38321842 DOI: 10.1021/acs.analchem.3c05628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2024]
Abstract
Raman spectroscopy is a popular process analytical technology (PAT) tool that has been increasingly used to monitor and control the monoclonal antibody (mAb) manufacturing process. Although it allows the characterization of a variety of quality attributes by developing chemometric models, a large quantity of representative data is required, and hence, the model development process can be time-consuming. In recent years, the pharmaceutical industry has been expediting new drug development in order to achieve faster delivery of life-changing drugs to patients. The shortened development timelines have impacted the Raman application, as less time is allowed for data collection. To address this problem, an innovative Just-in-Time (JIT) strategy is proposed with the goal of reducing the time needed for Raman model development and ensuring its implementation. To demonstrate its capabilities, a proof-of-concept study was performed by applying the JIT strategy to a biologic continuous process for producing monoclonal antibody products. Raman spectroscopy and online two-dimensional liquid chromatography (2D-LC) were integrated as a PAT analyzer system. Raman models of antibody titer and aggregate percentage were calibrated by chemometric modeling in real-time. The models were also updated in real-time using new data collected during process monitoring. Initial Raman models with adequate performance were established using data collected from two lab-scale cell culture batches and subsequently updated using one scale-up batch. The JIT strategy is capable of accelerating Raman method development to monitor and guide the expedited biologics process development.
Collapse
Affiliation(s)
- Hanzhou Feng
- Data Rich Measurements, Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Zachary D Dunn
- Data Rich Measurements, Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Roli Kargupta
- Biologic Process Development, Pharmaceutical Process Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Jay Desai
- Data Rich Measurements, Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Chelsea Phuangthong
- Biologic Process Development, Pharmaceutical Process Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Tayi Venkata
- Biologic Process Development, Pharmaceutical Process Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Emmanuel Appiah-Amponsah
- Data Rich Measurements, Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| | - Bhumit Patel
- Data Rich Measurements, Analytical Research and Development, Merck & Co., Inc., Rahway, New Jersey 07065, United States
| |
Collapse
|
4
|
Scalable mRNA Machine for Regulatory Approval of Variable Scale between 1000 Clinical Doses to 10 Million Manufacturing Scale Doses. Processes (Basel) 2023. [DOI: 10.3390/pr11030745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2023] Open
Abstract
The production of messenger ribonucleic acid (mRNA) and other biologics is performed primarily in batch mode. This results in larger equipment, cleaning/sterilization volumes, and dead times compared to any continuous approach. Consequently, production throughput is lower and capital costs are relatively high. Switching to continuous production thus reduces the production footprint and also lowers the cost of goods (COG). During process development, from the provision of clinical trial samples to the production plant, different plant sizes are usually required, operating at different operating parameters. To speed up this step, it would be optimal if only one plant with the same equipment and piping could be used for all sizes. In this study, an efficient solution to this old challenge in biologics manufacturing is demonstrated, namely the qualification and validation of a plant setup for clinical trial doses of about 1000 doses and a production scale-up of about 10 million doses. Using the current example of the Comirnaty BNT162b2 mRNA vaccine, the cost-intensive in vitro transcription was first optimized in batch so that a yield of 12 g/L mRNA was achieved, and then successfully transferred to continuous production in the segmented plug flow reactor with subsequent purification using ultra- and diafiltration, which enables the recycling of costly reactants. To realize automated process control as well as real-time product release, the use of appropriate process analytical technology is essential. This will also be used to efficiently capture the product slug so that no product loss occurs and contamination from the fill-up phase is <1%. Further work will focus on real-time release testing during a continuous operating campaign under autonomous operational control. Such efforts will enable direct industrialization in collaboration with appropriate industry partners, their regulatory affairs, and quality assurance. A production scale-operation could be directly supported and managed by data-driven decisions.
Collapse
|
5
|
Goyal A, Vu B, Maranholkar V, Patil U, Kourentzi K, Willson RC. Continuous monitoring of IgG using immobilized fluorescent reporters. Biotechnol Bioeng 2023; 120:482-490. [PMID: 36225160 DOI: 10.1002/bit.28254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 09/30/2022] [Accepted: 10/08/2022] [Indexed: 01/13/2023]
Abstract
In the manufacture of therapeutic monoclonal antibodies, the clarified cell culture fluid (CCF) is typically loaded onto an initial protein A affinity capture column. Imperfect mass transfer and loading to maximum capacity can risk antibody breakthrough and loss of valuable product, but conservative underloading wastes expensive protein A resin. In addition, the effects of column fouling and ligand degradation require the frequent optimization of immunoglobulin G (IgG) loading to avoid wastage. Continuous real-time monitoring of IgG flowthrough is of great interest, therefore. We previously developed a fluorescence-based monitoring technology that allows batch mix-and-read mAb detection in the CCF. Here, we report the use of reporters immobilized on cyanogenbromide-activated Sepharose 4B resin for continuous detection of IgG in column breakthrough. The column effluent is continuously contacted with immobilized fluorescein-labeled Fc-binding ligands in a small monitoring column to produce an immediately-detectable change in fluorescence intensity. The technology allows rapid and reliable monitoring of IgG in a flowing stream of clarified CCF emerging from a protein A column, without prior sample preparation. We observed a significant change in fluorescence intensity at 0.5 g/L human IgG, sufficient to detect a 5% breakthrough of a 10 g/L load, within 18 s at a flow rate of 0.5 ml/min. The current small-scale technology is suitable for use in process development, but the chemistry should be readily adaptable to larger scale applications using fiber-optic sensors, and continuous IgG monitoring could be applicable in a variety of upstream and downstream process settings.
Collapse
Affiliation(s)
- Atul Goyal
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas, USA
| | - Binh Vu
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas, USA
| | - Vijay Maranholkar
- Department of Biology and Biochemistry, University of Houston, Houston, Texas, USA
| | - Ujwal Patil
- Department of Biology and Biochemistry, University of Houston, Houston, Texas, USA
| | - Katerina Kourentzi
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas, USA
| | - Richard C Willson
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas, USA.,Department of Biology and Biochemistry, University of Houston, Houston, Texas, USA.,Escuela de Medicina y Ciencias de la Salud, Tecnológico de Monterrey, Monterrey, Nuevo León, Mexico
| |
Collapse
|
6
|
Richter J, Lange F, Scheper T, Solle D, Beutel S. Digitale Zwillinge in der Bioprozesstechnik – Chancen und Möglichkeiten. CHEM-ING-TECH 2022. [DOI: 10.1002/cite.202200166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Affiliation(s)
- Jannik Richter
- Leibniz Universität Hannover Institut für Technische Chemie Callinstraße 5 30167 Hannover Deutschland
| | - Ferdinand Lange
- Leibniz Universität Hannover Institut für Technische Chemie Callinstraße 5 30167 Hannover Deutschland
| | - Thomas Scheper
- Leibniz Universität Hannover Institut für Technische Chemie Callinstraße 5 30167 Hannover Deutschland
| | - Dörte Solle
- Leibniz Universität Hannover Institut für Technische Chemie Callinstraße 5 30167 Hannover Deutschland
| | - Sascha Beutel
- Leibniz Universität Hannover Institut für Technische Chemie Callinstraße 5 30167 Hannover Deutschland
| |
Collapse
|
7
|
Emerging PAT for Freeze-Drying Processes for Advanced Process Control. Processes (Basel) 2022. [DOI: 10.3390/pr10102059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Lyophilization is a widely used drying operation, but long processing times are a major drawback. Most lyophilization processes are conducted by a recipe that is not changed or optimized after implementation. With the regulatory demanded quality by design (QbD) approach, the process can be controlled inside an optimal range, ensuring safe process conditions. Process analytical technology (PAT) is crucial because it allows real-time monitoring and is part of a control strategy. In this work, emerging PAT (manometric temperature measurement (MTM), comparative pressure measurement, heat flux sensors, and ice ruler) are used for measurements during the freeze-drying process, and their potential for implementation inside a control strategy is outlined.
Collapse
|
8
|
Process Automation and Control Strategy by Quality-by-Design in Total Continuous mRNA Manufacturing Platforms. Processes (Basel) 2022. [DOI: 10.3390/pr10091783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Vaccine supply has a bottleneck in manufacturing capacity due to operation personnel and chemicals needed. Assessment of existing mRNA (messenger ribonucleic acid) vaccine processing show needs for continuous manufacturing processes. This is enabled by strict application of the regulatory demanded quality by design process based on digital twins, process analytical technology, and control automation strategies in order to improve process transfer for manufacturing capacity, reduction out-of-specification batch failures, qualified personnel training and number, optimal utilization of buffers and chemicals as well as speed-up of product release. In this work, process control concepts, which are necessary for achieving autonomous, continuous manufacturing, for mRNA manufacturing are explained and proven to be ready for industrialization. The application of the process control strategies developed in this work enable the previously pointed out benefits. By switching from batch-wise to continuous mRNA production as was shown in previous work, which was the base for this study, a potential cost reduction by a factor 5 (i.e., from EUR 0.380 per dose to EUR 0.085 per dose) is achievable. Mainly, based on reduction of personnel (factor 30) and consumable (factor 7.5) per campaign due to the significant share of raw materials in the manufacturing costs (74–97). Future research focus following this work may be on model-based predictive control to gain further optimization potential of potential batch failure and out of specification (OOS) number reduction.
Collapse
|
9
|
Schmidt A, Helgers H, Hengelbrock A, Vetter F, Juckers A, Strube J. Digital Twins for Continuous mRNA Production. CHEM-ING-TECH 2022. [DOI: 10.1002/cite.202255421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- A. Schmidt
- Clausthal University of Technology Institute for Separation and Process Technology Leibnizstr. 15 38678 Clausthal-Zellerfeld Germany
| | - H. Helgers
- Clausthal University of Technology Institute for Separation and Process Technology Leibnizstr. 15 38678 Clausthal-Zellerfeld Germany
| | - A. Hengelbrock
- Clausthal University of Technology Institute for Separation and Process Technology Leibnizstr. 15 38678 Clausthal-Zellerfeld Germany
| | - F. L. Vetter
- Clausthal University of Technology Institute for Separation and Process Technology Leibnizstr. 15 38678 Clausthal-Zellerfeld Germany
| | - A. Juckers
- Clausthal University of Technology Institute for Separation and Process Technology Leibnizstr. 15 38678 Clausthal-Zellerfeld Germany
| | - J. Strube
- Clausthal University of Technology Institute for Separation and Process Technology Leibnizstr. 15 38678 Clausthal-Zellerfeld Germany
| |
Collapse
|
10
|
Abstract
The development and adoption of digital twins (DT) for Quality-by-Design (QbD)-based processes with flexible operating points within a proven acceptable range (PAR) and automation through Advanced Process Control (APC) with Process Analytical Technology (PAT) instead of conventional process execution based on offline analytics and inflexible process set points is one of the great challenges in modern biotechnology. Virus-like particles (VLPs) are part of a line of innovative drug substances (DS). VLPs, especially those based on human immunodeficiency virus (HIV), HIV-1 Gag VLPs, have very high potential as a versatile vaccination platform, allowing for pseudotyping with heterologous envelope proteins, e.g., the S protein of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). As enveloped VLPs, optimal process control with minimal hold times is essential. This study demonstrates, for the first time, the use of a digital twin for the overall production process of HIV-1 Gag VLPs from cultivation, clarification, and purification to lyophilization. The accuracy of the digital twins is in the range of 0.8 to 1.4% in depth filtration (DF) and 4.6 to 5.2% in ultrafiltration/diafiltration (UFDF). The uncertainty due to variability in the model parameter determination is less than 4.5% (DF) and less than 3.8% (UFDF). In the DF, a prediction of the final filter capacity was demonstrated from as low as 5.8% (9mbar) of the final transmembrane pressure (TMP). The scale-up based on DT in chromatography shows optimization potential in productivity up to a factor of 2. The schedule based on DT and PAT for APC has been compared to conventional process control, and hold-time and process duration reductions by a factor of 2 have been achieved. This work lays the foundation for the short-term validation of the DT and PAT for APC in an automated S7 process environment and the conversion from batch to continuous production.
Collapse
|
11
|
Abstract
Quality-by-Design (QbD) is demanded by regulatory authorities in biopharmaceutical production. Within the QbD frame advanced process control (APC), facilitated through process analytical technology (PAT) and digital twins (DT), plays an increasingly important role as it can help to assure to stay within the predefined proven acceptable range (PAR).This ensures high product quality, minimizes failure and is an important step towards a real-time-release testing (RTRT) that could help to accelerate time-to-market of drug substances, which is becoming even more important in light of dynamical pandemic situations. The approach is exemplified on scFv manufacturing in Escherichia coli. Simulation results from digital twins are compared to experimental data and found to be accurate and precise. Harvest is achieved by tangential flow filtration followed by product release through high pressure homogenization and subsequent clarification by tangential flow filtration. Digital twins of the membrane processes show that shear rate and transmembrane pressure are significant process parameters, which is in line with experimental data. Optimized settings were applied to 0.3 bar and a shear rate of 11,000 s−1. Productivity of chromatography steps were 5.3 g/L/d (Protein L) and 2167 g/L/d (CEX) and the final product concentration was 8 g/L. Based on digital twin results, an optimized process schedule was developed that decreased purification time to one working day, which is a factor-two reduction compared to the conventional process schedule. This work presents the basis for future studies on advanced process control and automation for biologics production in microbials in regulated industries.
Collapse
|
12
|
Process Design and Optimization towards Digital Twins for HIV-Gag VLP Production in HEK293 Cells, including Purification. Processes (Basel) 2022. [DOI: 10.3390/pr10020419] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Despite great efforts to develop a vaccine against human immunodeficiency virus (HIV), which causes AIDS if untreated, no approved HIV vaccine is available to date. A promising class of vaccines are virus-like particles (VLPs), which were shown to be very effective for the prevention of other diseases. In this study, production of HI-VLPs using different 293F cell lines, followed by a three-step purification of HI-VLPs, was conducted. The quality-by-design-based process development was supported by process analytical technology (PAT). The HI-VLP concentration increased 12.5-fold while >80% purity was achieved. This article reports on the first general process development and optimization up to purification. Further research will focus on process development for polishing and formulation up to lyophilization. In addition, process analytical technology and process modeling for process automation and optimization by digital twins in the context of quality-by-design framework will be developed.
Collapse
|
13
|
Towards Autonomous Process Control—Digital Twin for CHO Cell-Based Antibody Manufacturing Using a Dynamic Metabolic Model. Processes (Basel) 2022. [DOI: 10.3390/pr10020316] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
The development of new biologics is becoming more challenging due to global competition and increased requirements for process understanding and assured quality in regulatory approval. As a result, there is a need for predictive, mechanistic process models. These reduce the resources and time required in process development, generating understanding, expanding the possible operating space, and providing the basis for a digital twin for automated process control. Monoclonal antibodies are an important representative of industrially produced biologics that can be used for a wide range of applications. In this work, the validation of a mechanistic process model with respect to sensitivity, as well as accuracy and precision, is presented. For the investigated process conditions, the concentration of glycine, phenylalanine, tyrosine, and glutamine have been identified as significant influencing factors for product formation via statistical evaluation. Cell growth is, under the investigated process conditions, significantly dependent on the concentration of glucose within the investigated design space. Other significant amino acids were identified. A Monte Carlo simulation was used to simulate the cultivation run with an optimized medium resulting from the sensitivity analysis. The precision of the model was shown to have a 95% confidence interval. The model shown here includes the implementation of cell death in addition to models described in the literature.
Collapse
|
14
|
Fast and Versatile Chromatography Process Design and Operation Optimization with the Aid of Artificial Intelligence. Processes (Basel) 2021. [DOI: 10.3390/pr9122121] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
Preparative and process chromatography is a versatile unit operation for the capture, purification, and polishing of a broad variety of molecules, especially very similar and complex compounds such as sugars, isomers, enantiomers, diastereomers, plant extracts, and metal ions such as rare earth elements. Another steadily growing field of application is biochromatography, with a diversity of complex compounds such as peptides, proteins, mAbs, fragments, VLPs, and even mRNA vaccines. Aside from molecular diversity, separation mechanisms range from selective affinity ligands, hydrophobic interaction, ion exchange, and mixed modes. Biochromatography is utilized on a scale of a few kilograms to 100,000 tons annually at about 20 to 250 cm in column diameter. Hence, a versatile and fast tool is needed for process design as well as operation optimization and process control. Existing process modeling approaches have the obstacle of sophisticated laboratory scale experimental setups for model parameter determination and model validation. For a broader application in daily project work, the approach has to be faster and require less effort for non-chromatography experts. Through the extensive advances in the field of artificial intelligence, new methods have emerged to address this need. This paper proposes an artificial neural network-based approach which enables the identification of competitive Langmuir-isotherm parameters of arbitrary three-component mixtures on a previously specified column. This is realized by training an ANN with simulated chromatograms varying in isotherm parameters. In contrast to traditional parameter estimation techniques, the estimation time is reduced to milliseconds, and the need for expert or prior knowledge to obtain feasible estimates is reduced.
Collapse
|
15
|
On the Use of Surface Plasmon Resonance-Based Biosensors for Advanced Bioprocess Monitoring. Processes (Basel) 2021. [DOI: 10.3390/pr9111996] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Biomanufacturers are being incited by regulatory agencies to transition from a quality by testing framework, where they extensively test their product after their production, to more of a quality by design or even quality by control framework. This requires powerful analytical tools and sensors enabling measurements of key process variables and/or product quality attributes during production, preferably in an online manner. As such, the demand for monitoring technologies is rapidly growing. In this context, we believe surface plasmon resonance (SPR)-based biosensors can play a role in enabling the development of improved bioprocess monitoring and control strategies. The SPR technique has been profusely used to probe the binding behavior of a solution species with a sensor surface-immobilized partner in an investigative context, but its ability to detect binding in real-time and without a label has been exploited for monitoring purposes and is promising for the near future. In this review, we examine applications of SPR that are or could be related to bioprocess monitoring in three spheres: biotherapeutics production monitoring, vaccine monitoring, and bacteria and contaminant detection. These applications mainly exploit SPR’s ability to measure solution species concentrations, but performing kinetic analyses is also possible and could prove useful for product quality assessments. We follow with a discussion on the limitations of SPR in a monitoring role and how recent advances in hardware and SPR response modeling could counter them. Mainly, throughput limitations can be addressed by multi-detection spot instruments, and nonspecific binding effects can be alleviated by new antifouling materials. A plethora of methods are available for cell growth and metabolism monitoring, but product monitoring is performed mainly a posteriori. SPR-based biosensors exhibit potential as product monitoring tools from early production to the end of downstream processing, paving the way for more efficient production control. However, more work needs to be done to facilitate or eliminate the need for sample preprocessing and to optimize the experimental protocols.
Collapse
|
16
|
Abstract
The global coronavirus pandemic continues to restrict public life worldwide. An effective means of limiting the pandemic is vaccination. Messenger ribonucleic acid (mRNA) vaccines currently available on the market have proven to be a well-tolerated and effective class of vaccine against coronavirus type 2 (CoV2). Accordingly, demand is presently outstripping mRNA vaccine production. One way to increase productivity is to switch from the currently performed batch to continuous in vitro transcription, which has proven to be a crucial material-consuming step. In this article, a physico-chemical model of in vitro mRNA transcription in a tubular reactor is presented and compared to classical batch and continuous in vitro transcription in a stirred tank. The three models are validated based on a distinct and quantitative validation workflow. Statistically significant parameters are identified as part of the parameter determination concept. Monte Carlo simulations showed that the model is precise, with a deviation of less than 1%. The advantages of continuous production are pointed out compared to batchwise in vitro transcription by optimization of the space–time yield. Improvements of a factor of 56 (0.011 µM/min) in the case of the continuously stirred tank reactor (CSTR) and 68 (0.013 µM/min) in the case of the plug flow reactor (PFR) were found.
Collapse
|
17
|
Fast and Flexible mRNA Vaccine Manufacturing as a Solution to Pandemic Situations by Adopting Chemical Engineering Good Practice—Continuous Autonomous Operation in Stainless Steel Equipment Concepts. Processes (Basel) 2021. [DOI: 10.3390/pr9111874] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
SARS-COVID-19 vaccine supply for the total worldwide population has a bottleneck in manufacturing capacity. Assessment of existing messenger ribonucleic acid (mRNA) vaccine processing shows a need for digital twins enabled by process analytical technology approaches in order to improve process transfer for manufacturing capacity multiplication, a reduction in out-of-specification batch failures, qualified personal training for faster validation and efficient operation, optimal utilization of scarce buffers and chemicals and speed-up of product release by continuous manufacturing. In this work, three manufacturing concepts for mRNA-based vaccines are evaluated: Batch, full-continuous and semi-continuous. Technical transfer from batch single-use to semi-continuous stainless-steel, i.e., plasmid deoxyribonucleic acid (pDNA) in batch and mRNA in continuous operation mode, is recommended, in order to gain: faster plant commissioning and start-up times of about 8–12 months and a rise in dose number by a factor of about 30 per year, with almost identical efforts in capital expenditures (CAPEX) and personnel resources, which are the dominant bottlenecks at the moment, at about 25% lower operating expenses (OPEX). Consumables are also reduceable by a factor of 6 as outcome of this study. Further optimization potential is seen at consequent digital twin and PAT (Process Analytical Technology) concept integration as key-enabling technologies towards autonomous operation including real-time release-testing.
Collapse
|
18
|
Advanced Process Analytical Technology in Combination with Process Modeling for Endpoint and Model Parameter Determination in Lyophilization Process Design and Optimization. Processes (Basel) 2021. [DOI: 10.3390/pr9091600] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Lyophilization is widely used in the preservation of thermolabile products. The main shortcoming is the long processing time. Lyophilization processes are mostly based on a recipe that is not changed, but, with the Quality by Design (QbD) approach and use of Process Analytical Technology (PAT), the process duration can be optimized for maximum productivity while ensuring product safety. In this work, an advanced PAT approach is used for the endpoint determination of primary drying. Manometric temperature measurement (MTM) and comparative pressure measurement are used to determine the endpoint of the batch while a modeling approach is outlined that is able to calculate the endpoint of every vial in the batch. This approach can be used for process development, control and optimization.
Collapse
|
19
|
Digital Twin of mRNA-Based SARS-COVID-19 Vaccine Manufacturing towards Autonomous Operation for Improvements in Speed, Scale, Robustness, Flexibility and Real-Time Release Testing. Processes (Basel) 2021. [DOI: 10.3390/pr9050748] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Supplying SARS-COVID-19 vaccines in quantities to meet global demand has a bottleneck in manufacturing capacity. Assessment of existing mRNA (messenger ribonucleic acid) vaccine processing shows the need for digital twins enabled by process analytical technology approaches to improve process transfers for manufacturing capacity multiplication, reduction of out-of-specification batch failures, qualified personnel training for faster validation and efficient operation, optimal utilization of scarce buffers and chemicals, and faster product release. A digital twin of the total pDNA (plasmid deoxyribonucleic acid) to mRNA process is proposed. In addition, a first feasibility of multisensory process analytical technology (PAT) is shown. Process performance characteristics are derived as results and evaluated regarding manufacturing technology bottlenecks. Potential improvements could be pointed out such as dilution reduction in lysis, and potential reduction of necessary chromatography steps. 1 g pDNA may lead to about 30 g mRNA. This shifts the bottleneck towards the mRNA processing step, which points out co-transcriptional capping as a preferred option to reduce the number of purification steps. Purity demands are fulfilled by a combination of mixed-mode and reversed-phase chromatography as established unit operations on a higher industrial readiness level than e.g., precipitation and ethanol-chloroform extraction. As a final step, lyophilization was chosen for stability, storage and transportation logistics. Alternative process units like UF/DF (ultra-/diafiltration) integration would allow the adjustment of final concentration and buffer composition before lipid-nano particle (LNP) formulation. The complete digital twin is proposed for further validation in manufacturing scale and utilization in process optimization and manufacturing operations. The first PAT results should be followed by detailed investigation of different batches and processing steps in order to implement this strategy for process control and reliable, efficient operation.
Collapse
|
20
|
Process Analytical Technology for Precipitation Process Integration into Biologics Manufacturing towards Autonomous Operation—mAb Case Study. Processes (Basel) 2021. [DOI: 10.3390/pr9030488] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
The integration of real time release testing into an advanced process control (APC) concept in combination with digital twins accelerates the process towards autonomous operation. In order to implement this, on the one hand, measurement technology is required that is capable of measuring relevant process data online, and on the other hand, a suitable model must be available to calculate new process parameters from this data, which are then used for process control. Therefore, the feasibility of online measurement techniques including Raman-spectroscopy, attenuated total reflection Fourier transformed infrared spectroscopy (ATR-FTIR), diode array detector (DAD) and fluorescence is demonstrated within the framework of the process analytical technology (PAT) initiative. The best result is achieved by Raman, which reliably detected mAb concentration (R2 of 0.93) and purity (R2 of 0.85) in real time, followed by DAD. Furthermore, the combination of DAD and Raman has been investigated, which provides a promising extension due to the orthogonal measurement methods and higher process robustness. The combination led to a prediction for concentration with a R2 of 0.90 ± 3.9% and for purity of 0.72 ± 4.9%. These data are used to run simulation studies to show the feasibility of process control with a suitable digital twin within the APC concept.
Collapse
|
21
|
PAT for Continuous Chromatography Integrated into Continuous Manufacturing of Biologics towards Autonomous Operation. Processes (Basel) 2021. [DOI: 10.3390/pr9030472] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
This study proposes a reliable inline PAT concept for the simultaneous monitoring of different product components after chromatography. The feed for purification consisted of four main components, IgG monomer, dimer, and two lower molecular weight components of 4.4 kDa and 1 kDa molecular weight. The proposed measurement setup consists of a UV–VIS diode-array detector and a fluorescence detector. Applying this system, a R2 of 0.93 for the target component, a R2 of 0.67 for the dimer, a R2 of 0.91 for the first side component and a R2 of 0.93 for the second side component is achieved. Root mean square error for IgG monomer was 0.027 g/L, for dimer 0.0047 g/L, for side component 1 0.016 g/L and for the side component 2 0.014 g/L. The proposed measurement concept tracked component concentration reliably down to 0.05 g/L. Zero-point fluctuations were kept within a standard deviation of 0.018 g/L for samples with no IgG concentration but with side components present, allowing a reliable detection of the target component. The main reason inline concentration measurements have not been established yet, is the false-positive measurement of target components when side components are present. This problem was eliminated using the combination of fluorescence and UV–VIS data for the test system. The use of this measurement system is simulated for the test system, allowing an automatic fraction cut at 0.05 g/L. In this simulation a consistent yield of >99% was achieved. Process disturbances for processed feed volume, feed purity and feed IgG concentration can be compensated with this setup. Compared to a timed process control, yield can be increased by up to 12.5%, if unexpected process disturbances occur.
Collapse
|