1
|
Elahi Y, Baker MAB. Light Control in Microbial Systems. Int J Mol Sci 2024; 25:4001. [PMID: 38612810 PMCID: PMC11011852 DOI: 10.3390/ijms25074001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Revised: 03/27/2024] [Accepted: 03/28/2024] [Indexed: 04/14/2024] Open
Abstract
Light is a key environmental component influencing many biological processes, particularly in prokaryotes such as archaea and bacteria. Light control techniques have revolutionized precise manipulation at molecular and cellular levels in recent years. Bacteria, with adaptability and genetic tractability, are promising candidates for light control studies. This review investigates the mechanisms underlying light activation in bacteria and discusses recent advancements focusing on light control methods and techniques for controlling bacteria. We delve into the mechanisms by which bacteria sense and transduce light signals, including engineered photoreceptors and light-sensitive actuators, and various strategies employed to modulate gene expression, protein function, and bacterial motility. Furthermore, we highlight recent developments in light-integrated methods of controlling microbial responses, such as upconversion nanoparticles and optical tweezers, which can enhance the spatial and temporal control of bacteria and open new horizons for biomedical applications.
Collapse
|
2
|
Koegl M, Delwig M, Zigan L. Characterization of Fluorescence Tracers for Thermometry and Film Thickness Measurements in Liquid Coolants Relevant for Thermal Management of Electric and Electronic Components. SENSORS (BASEL, SWITZERLAND) 2022; 22:8892. [PMID: 36433496 PMCID: PMC9694582 DOI: 10.3390/s22228892] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 11/10/2022] [Accepted: 11/14/2022] [Indexed: 06/16/2023]
Abstract
This study investigated a novel two-color LIF (laser-induced fluorescence) technique for thermometry in coolants relevant for electric components. In principle, this diagnostic enables thermometry in liquid flows but also a simultaneous determination of film thickness and film temperature, which is relevant, e.g., for jet impingement cooled electric components. Temperature measurements are based on a temperature-sensitive intensity ratio of special tracers realized by suitable band pass filters within the respective emission spectra. For this purpose, the heat transfer fluids Fragoltherm F12, Marlotherm LH, and a water-glycol mixture WG20 (80 vol.% water, 20 vol.% glycol) and its individual components were doped with suitable tracers. The tracer Eosin-Y was utilized for polar coolants (water, WG20, and glycol) and Nile red was utilized for non-polar solvents (Fragoltherm F12 and Marlotherm LH). The spectral LIF intensities were recorded for a wide range of temperatures (253-393 K), which are relevant for cooling of electric motors, batteries, and power electronics. Furthermore, absorption spectra were analyzed as well. The temperature-dependent fluorescence measurements revealed different behavior for the polar and non-polar solvents. A temperature increase in the polar solvents (water, WG20, glycol) led to a spectral shift of the emission peaks of Eosin-Y towards longer wavelengths (red-shifted), while the peaks of Nile red in the non-polar solvents (Fragoltherm F12 and Marlotherm LH) showed an opposite behavior and were blue-shifted. The highest average temperature sensitivity was achieved for Marlotherm LH (4.22%/K), followed by glycol (1.99%/K), WG20 (1.80%/K), water (1.62%/K), and Fragoltherm F12 (1.12%/K). These sensitivities are similar to or even much higher than the literature data of other LIF tracers, which were, however, not determined in those coolants. Consequently, the two novel proposed dyes for the studied heat transfer liquids enable a reliable temperature determination.
Collapse
Affiliation(s)
- Matthias Koegl
- Institut für Thermodynamik, Professur für Energiewandlung, Fakultät für Luft- und Raumfahrttechnik, Universität der Bundeswehr München (UniBw M), D-85577 Neubiberg, Germany
| | - Moritz Delwig
- Institut für Thermodynamik, Professur für Energiewandlung, Fakultät für Luft- und Raumfahrttechnik, Universität der Bundeswehr München (UniBw M), D-85577 Neubiberg, Germany
| | - Lars Zigan
- Institut für Thermodynamik, Professur für Energiewandlung, Fakultät für Luft- und Raumfahrttechnik, Universität der Bundeswehr München (UniBw M), D-85577 Neubiberg, Germany
- Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), D-91052 Erlangen, Germany
| |
Collapse
|
3
|
Koegl M, Dai H, Baderschneider K, Ulrich H, Zigan L. Polarization-dependent LIF/Mie ratio for sizing of micrometric ethanol droplets doped with Nile red. APPLIED OPTICS 2022; 61:4204-4214. [PMID: 36256098 DOI: 10.1364/ao.457685] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Accepted: 04/22/2022] [Indexed: 06/16/2023]
Abstract
The present study deals with droplet sizing based on laser-induced fluorescence (LIF) and Mie scattering for varied polarization of the utilized laser (parallel or perpendicular). The polarization-dependent LIF/Mie ratio is studied for micrometric droplets (25-60 µm) produced with a droplet generator. The investigations were carried out with the dye Nile red dissolved in ethanol and ethanol/iso-octane mixtures. A spectral absorption and fluorescence characterization at various dye and ethanol concentrations is carried out in a cuvette in order to identify reabsorption effects. The LIF|| droplet images (index ||: parallel polarization) show a more homogeneous intensity distribution in the droplets and slightly stronger morphology-dependent resonances (MDRs) in comparison to LIF⊥ (index ⊥: perpendicular polarization). The spectral LIF emissions reveal a dependence of the MDR on the ethanol admixture. The larger the ethanol content, the lower the MDR peak, which is also shifted further to the red part of the spectrum. The Mie droplet signal images are mainly characterized by two distinct glare points, one at the entrance of the laser light (reflection) and one at the exit (first-order refraction). The Mie⊥ images show a more pronounced entrance glare point, in comparison to Mie||, where the exit glare point is more pronounced. These observations are in accordance with the theory. The calibration curve of the micro droplet signals revealed a volumetric trend of the LIF signals and a slightly higher LIF⊥ signal and sensitivity in comparison to LIF||. The signal Mie⊥ follows roughly a quadratic trend on average, while Mie|| follows a linear trend. Consequently, the calculated LIF⊥/Mie⊥ ratio shows a linear trend, whereas the LIF||/Mie|| ratio shows a quadratic trend, which confirms theoretical calculations. A numerical simulation of the Mie signal at various detection angles shows a good agreement with the experimental data at large apertures.
Collapse
|
4
|
Koegl M, Dai H, Qomi MP, Bauer F, Eppinger B, Zigan L. Morphology-dependent resonances in laser-induced fluorescence images of micrometric gasoline/ethanol droplets utilizing the dye nile red. APPLIED OPTICS 2021; 60:5000-5011. [PMID: 34143064 DOI: 10.1364/ao.423059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Accepted: 05/08/2021] [Indexed: 06/12/2023]
Abstract
The present study deals with the solvent-dependent morphology-dependent resonances (MDR) in the laser-induced fluorescence (LIF) signal of monodisperse gasoline droplets (30 µm-60 µm) generated with a droplet generator. To investigate the influence of an ethanol addition to gasoline and the respective LIF signal of the dye nile red dissolved in these fuel blends, a reference gasoline fuel is blended with various ethanol concentrations from E0 (gasoline) to E100 (pure ethanol). A spectral fluorescence characterization of the investigated fuel mixtures at various concentrations is carried out in a micro cell in order to identify the dye and ethanol concentration influence of the respective fuel mixtures. The absorption and emission spectra of the fuel mixtures show a Stokes shift with increasing ethanol concentration towards larger wavelengths. The coefficient of variation (COV) of the fluorescence signals of spherical droplets was utilized to characterize the MDR effects within the droplet LIF images. The investigations revealed an increase of MDR contribution in terms of the COV of LIF signals with larger droplet diameters. For small droplets, no monotonic trend was found for contribution of MDR in the LIF signal as a function of the ethanol concentration. For larger droplets (e.g., 50 µm-60 µm), a lower contribution of MDR in LIF signals was observed with increasing ethanol content. For E80 and most of the studied ethanol blends, the normalized integrated COV values exhibited maxima at certain droplet sizes (40 µm, 47.5 µm, and 55 µm), which indicate the presence of distinct MDR effects.
Collapse
|
5
|
Cai S, Sun Y, Chu H, Yang W, Yu H, Liu L. Microlenses arrays: Fabrication, materials, and applications. Microsc Res Tech 2021; 84:2784-2806. [PMID: 33988282 DOI: 10.1002/jemt.23818] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 04/21/2021] [Accepted: 05/02/2021] [Indexed: 11/07/2022]
Abstract
Microlenses have become an indispensable optical element in many optical systems. The advancement of technology has led to a wider variety of microlenses fabrication methods, but these methods suffer from, more or less, some limitations. In this article, we review the manufacturing technology of microlenses from the direct and indirect perspectives. First, we present several fabrication methods and their advantages and disadvantages are discussed. Then, we discuss the commonly used materials for fabricating microlenses and the applications of microlenses in various fields. Finally, we point out the prospects for the future development of microlenses and their fabrication methods.
Collapse
Affiliation(s)
- Shuxiang Cai
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai, China
| | - Yalin Sun
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai, China
| | - Honghui Chu
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai, China
| | - Wenguang Yang
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai, China
| | - Haibo Yu
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China
| | - Lianqing Liu
- State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China
| |
Collapse
|
6
|
Analysis of the LIF/Mie Ratio from Individual Droplets for Planar Droplet Sizing: Application to Gasoline Fuels and Their Mixtures with Ethanol. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9224900] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
In this work, the possibility of using planar droplet sizing (PDS) based on laser-induced fluorescence (LIF) and Mie scattering was investigated within the framework of measuring the droplet Sauter mean diameter (SMD) of direct-injection spark-ignition (DISI) spray systems. For this purpose, LIF and Mie signals of monodisperse fuel droplets produced by a droplet generator were studied at engine relevant diameters (20–50 µm). The surrogate gasoline fuel Toliso (consisting of 65 vol. % isooctane, 35 vol. % toluene) and the biofuel blend E20 (consisting of 80 vol. % Toliso, 20 vol. % ethanol) were used and which were doped with the fluorescence dye “nile red”. The effects of ethanol admixture, dye concentration, laser power, and temperature variation on the LIF/Mie ratio were studied simultaneously at both macroscopic and microscopic scale. The deduced calibration curves of the LIF and Mie signals of both fuels showed volumetric and surface dependent behaviors, respectively, in accordance with the assumptions in the literature. The existence of glare points and morphology-dependent resonances (MDRs) lead to slightly higher LIF and Mie exponents of E20 in comparison to Toliso. In principle, these calibration curves enable the determination of the SMD from LIF/Mie ratio images of transient fuel sprays.
Collapse
|
7
|
Characterization of Nile Red as a Tracer for Laser-Induced Fluorescence Spectroscopy of Gasoline and Kerosene and Their Mixture with Biofuels. SENSORS 2019; 19:s19122822. [PMID: 31238590 PMCID: PMC6631788 DOI: 10.3390/s19122822] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Revised: 06/03/2019] [Accepted: 06/19/2019] [Indexed: 11/16/2022]
Abstract
Suitable fluorescence tracers (“dyes”) are needed for the planar measurement of droplet sizes by using a combination of laser-induced fluorescence (LIF) and Mie scattering. Currently, no suitable tracers have been characterized for application in planar droplet sizing in gasoline and kerosene fuels, as well as biofuel blends. One promising tracer is nile red, which belongs to the fluorophore group. For its utilization for droplet size measurements, preliminary characterization of the fluorescence of the respective fuel tracer mixtures are mandatory. For this purpose, the fluorescence and absorption behavior of nile red dissolved in the surrogate fuels Toliso and Jet A-1 as well as in biofuel blends was investigated. The fluorescence signal for nile red that was dissolved in the two base fuels Toliso and Jet A-1 showed a linear behavior as a function of dye concentration. The temperature effect on spectral absorption and emission of nile red was investigated in a specially designed test cell. An ethanol admixture to Toliso led to a spectral shift towards higher wavelengths. The absorption and emission bands were shifted towards lower wavelengths with increasing temperature for all fuels. Both absorption and fluorescence decreased with increasing temperature for all fuels, except for E20, which showed an increased fluorescence signal with increasing temperature. Jet A-1 and its blends with hydroprocessed esters and fatty acids (HEFA) and farnesane did not exhibit explicit variations in spectral absorption or emission, but these blends showed a more distinct temperature dependence compared to the Toliso-ethanol-blends. The effect of photo-dissociation of the LIF signal of the fuel tracer mixtures was studied, and all fuel mixtures besides Toliso showed a more or less distinct decay in the fluorescence signal with time. In summary, all investigated fuel-tracer mixtures are suitable for LIF/Mie ratio droplet sizing in combination with nile red at moderate temperatures and low evaporation cooling rates.
Collapse
|
8
|
Lin J, Kan Y, Jing X, Lu M. Design and Fabrication of a Three-Dimensional Artificial Compound Eye Using Two-Photon Polymerization. MICROMACHINES 2018; 9:E336. [PMID: 30424269 PMCID: PMC6082293 DOI: 10.3390/mi9070336] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Revised: 06/21/2018] [Accepted: 06/25/2018] [Indexed: 01/14/2023]
Abstract
Microlens arrays have been widely used in the fields of micro-optics because of the advantages of their high diffraction efficiency, high fill factor, and wide operating band. However, the microlens array still has problems with its smaller field of view (FOV) and lower utilization of light energy. In this paper, a 3D compound eye system consisting of a microlens array and a pinhole array was designed according to the optical principle of insect compound eye. The artificial compound eye structure was processed in two-photon polymerization processing technology. Ray tracing and optical system simulation of the designed artificial compound eye structure were performed. The results showed that the artificial compound eye structure had a wider FOV and higher light energy utilization than a conventional 2D microlens array. This thesis may lay a theoretical foundation for the structural optimization design of microlens arrays.
Collapse
Affiliation(s)
- Jieqiong Lin
- Key Laboratory of Micro/Nano and Ultra-Precision Manufacturing, School of Mechatronic Engineering, Changchun University of Technology, Changchun 130012, China.
| | - Yudi Kan
- Key Laboratory of Micro/Nano and Ultra-Precision Manufacturing, School of Mechatronic Engineering, Changchun University of Technology, Changchun 130012, China.
| | - Xian Jing
- Key Laboratory of Micro/Nano and Ultra-Precision Manufacturing, School of Mechatronic Engineering, Changchun University of Technology, Changchun 130012, China.
| | - Mingming Lu
- Key Laboratory of Micro/Nano and Ultra-Precision Manufacturing, School of Mechatronic Engineering, Changchun University of Technology, Changchun 130012, China.
| |
Collapse
|
9
|
Abstract
Water quality detection plays an increasingly important role in environmental protection. In this work, a novel colorimeter based on the Beer-Lambert law was designed for chemical element detection in water with high precision and miniaturized structure. As an example, the colorimeter can detect phosphorus, which was accomplished in this article to evaluate the performance. Simultaneously, a modified algorithm was applied to extend the linear measurable range. The colorimeter encompassed a near infrared laser source, a microflow cell based on microfluidic technology and a light-sensitive detector, then Micro-Electro-Mechanical System (MEMS) processing technology was used to form a stable integrated structure. Experiments were performed based on the ammonium molybdate spectrophotometric method, including the preparation of phosphorus standard solution, reducing agent, chromogenic agent and color reaction. The device can obtain a wide linear response range (0.05 mg/L up to 7.60 mg/L), a wide reliable measuring range up to 10.16 mg/L after using a novel algorithm, and a low limit of detection (0.02 mg/L). The size of flow cell in this design is 18 mm × 2.0 mm × 800 μm, obtaining a low reagent consumption of 0.004 mg ascorbic acid and 0.011 mg ammonium molybdate per determination. Achieving these advantages of miniaturized volume, high precision and low cost, the design can also be used in automated in situ detection.
Collapse
|
10
|
Chen X, Hou S, Chu J, Xiong Y, Xiong P, Liu G, Tian Y. Observation Interface of PDMS Membrane in a Microfluidic Chip Based on One-Step Molding. MICROMACHINES 2017. [PMCID: PMC6190290 DOI: 10.3390/mi8030064] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Nowadays, researchers are focusing on sorting, characterizing and detecting micron or submicron particles or bacteria in microfluidic chips. However, some contradictions hinder the applications of conventional microfluidic chips, including the low working distance of high resolving power microscopy and the low light transmittance of conventional microfluidic chips. In this paper, a rapid and readily accessible microfluidic fabrication method is presented to realize observation with high magnification microscopy. With the one-step molding process, the interconnections, the thin observation interface of polydimethylsiloxane (PDMS) membrane and microfluidic channels were integrated into an intact PDMS replica. Three kinds of PDMS replicas with different auxiliary beams were designed and optimized by leakage experiments and analytical software. The observation interfaces of a 170 μm thickness PDMS membrane enlarges the application domain of microfluidic chips. By adopting a solution of high magnification observation, microfluidic devices could be applied widely in medical science, biology and material science.
Collapse
Affiliation(s)
- Xiangyu Chen
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China; (X.C.); (P.X.)
| | - Shuangyue Hou
- National Synchrotron Radiation Laboratory, Unitersity of Science and Technology of China, Hefei 230029, China; (S.H.); (Y.X.)
| | - Jian Chu
- Institute of Materials, China Academy of Engineering Physics, Mianyang 621700, China;
| | - Ying Xiong
- National Synchrotron Radiation Laboratory, Unitersity of Science and Technology of China, Hefei 230029, China; (S.H.); (Y.X.)
| | - Penghui Xiong
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei 230026, China; (X.C.); (P.X.)
| | - Gang Liu
- National Synchrotron Radiation Laboratory, Unitersity of Science and Technology of China, Hefei 230029, China; (S.H.); (Y.X.)
- Correspondence: (G.L.); (Y.T.); Tel.: +86-551-6360-2122 (G.L.); +86-551-6360-1844 (Y.T.)
| | - Yangchao Tian
- National Synchrotron Radiation Laboratory, Unitersity of Science and Technology of China, Hefei 230029, China; (S.H.); (Y.X.)
- Correspondence: (G.L.); (Y.T.); Tel.: +86-551-6360-2122 (G.L.); +86-551-6360-1844 (Y.T.)
| |
Collapse
|
11
|
Ngernsutivorakul T, Cipolla CM, Dugan CE, Jin S, Morris MD, Kennedy RT, Esmonde-White FWL. Design and microfabrication of a miniature fiber optic probe with integrated lenses and mirrors for Raman and fluorescence measurements. Anal Bioanal Chem 2017; 409:275-285. [PMID: 27766359 PMCID: PMC5203949 DOI: 10.1007/s00216-016-9999-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2016] [Revised: 09/19/2016] [Accepted: 09/30/2016] [Indexed: 12/22/2022]
Abstract
Fiber optics coupled to components such as lenses and mirrors have seen extensive use as probes for Raman and fluorescence measurements. Probes can be placed directly on or into a sample to allow for simplified and remote application of these optical techniques. The size and complexity of such probes however limits their application. We have used microfabrication in polydimethylsiloxane (PDMS) to create compact probes that are 0.5 mm thick by 1 mm wide. The miniature probes incorporate pre-aligned mirrors, lenses, and two fiber optic guides to allow separate input and output optical paths suitable for Raman and fluorescence spectroscopy measurements. The fabricated probe has 70 % unidirectional optical throughput and generates no spectral artifacts in the wavelength range of 200 to 800 nm. The probe is demonstrated for measurement of fluorescence within microfluidic devices and collection of Raman spectra from a pharmaceutical tablet. The fluorescence limit of detection was 6 nM when using the probe to measure resorufin inside a 150-μm inner diameter glass capillary, 100 nM for resorufin in a 60-μm-deep × 100-μm-wide PDMS channel, and 11 nM for fluorescein in a 25-μm-deep × 80-μm-wide glass channel. It is demonstrated that the same probe can be used on different sample types, e.g., microfluidic chips and tablets. Compared to existing Raman and fluorescence probes, the microfabricated probes enable measurement in smaller spaces and have lower fabrication cost. Graphical abstract A microfabricated spectroscopic probe with integrated optics was developed for chemical detection in small spaces and in remote applications.
Collapse
Affiliation(s)
| | - Cynthia M Cipolla
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI, 48109, USA
| | - Colleen E Dugan
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI, 48109, USA
| | - Shi Jin
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI, 48109, USA
| | - Michael D Morris
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI, 48109, USA
| | - Robert T Kennedy
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI, 48109, USA.
- Department of Pharmacology, University of Michigan, 1150 W. Medical Center Drive, Ann Arbor, MI, 48109, USA.
| | - Francis W L Esmonde-White
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI, 48109, USA
- Kaiser Optical Systems Inc, 371 Parkland Plaza, Ann Arbor, MI, 48103, USA
| |
Collapse
|
12
|
Dai J, Li W, Gong B, Wang H, Xia M, Yang K. Measurement of the light scattering of single micrometer-sized particles captured with a microfluidic trap. OPTICS EXPRESS 2015; 23:30204-30215. [PMID: 26698501 DOI: 10.1364/oe.23.030204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Light scattering detection of a single particle is significant to both theoretical developments and application progresses of particle scattering. In this work, a new method employing the polydimethylsiloxane microfluidic catcher with self-regulation was developed to detect the light scattering of an individual micro particle (20.42, 23.75, and 31.10 μm) in a wide angular range. This system can rapidly (<2 min) immobilize single particles without aggregations and continuously analyze its light scattering ranging from 2° to 162°. The high success ratio of the capture, good agreement with the anticipation, and moderate time and cost make this method a promising candidate in single-particle-scattering applications.
Collapse
|