1
|
Shi J, Xu Z, Yang K, Li X, Guo C, Bai H, Fu W, Niu P, Yao J, Yang X. Rapid and noninvasive cell assay by microfluidic-integrated intracavity evanescent field absorption in a fiber ring laser. Anal Chim Acta 2023; 1283:341960. [PMID: 37977802 DOI: 10.1016/j.aca.2023.341960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2023] [Revised: 10/14/2023] [Accepted: 10/24/2023] [Indexed: 11/19/2023]
Abstract
BACKGROUND Highly sensitive and rapid detection of cell concentration and interfacial molecular events is of great value for biological, biomedical, and chemical research. Most traditional biosensors require large sample volumes and complicated functional modifications of the surface. It is of great significance to develop label-free biosensor platforms with minimal sample consumption for studying cell concentration changes and interfacial molecular events without labor-intensive procedures. RESULTS Here, a fiber-optic biosensor based on intracavity evanescent field absorption sensing is designed for sensitive and label-free cell assays for the first time. The interaction between the cells and the evanescent field is enhanced by introducing microfluidic-integrated intracavity absorption in a fiber ring laser. This strategy extends the range of targeted analytes to include quantification of a large number of targets on a surface and improves the detection sensitivity of the fiber-optic biosensor. The level of sensing resolution could be improved from 10-4 RIU to 10-7 RIU using this strategy. The stem cells were studied over a wide concentration range (from 500 to 1.2 × 105 cells/ml) and were measured sequentially. By measuring the output power of the intracavity absorption sensing system, the cell concentration can be directly determined in a label-free manner. The results show that dozens of stem cells can be sensitively detected with a sample consumption of 72 μL. The response was fast (15 s) with a low temperature cross-sensitivity of 0.031 cells·ml-1/°C. SIGNIFICANCE The proposed method suggests its capacity for true label-free and noninvasive cell assays with a low limit of detection and small sample consumption. This has the potential to be used as a universal tool for quantitative and qualitative characterization of various cells and other biochemical analytes.
Collapse
Affiliation(s)
- Jia Shi
- Tianjin Key Laboratory of Optoelectronic Detection Technology and System, School of Electronic and Information Engineering, Tiangong University, Tianjin, 300387, China; Key Laboratory of Opto-Electronics Information Technology (Ministry of Education), School of Precision Instruments and Opto-Electronic Engineering, Tianjin University, Tianjin, 300072, China.
| | - Ziyi Xu
- Tianjin Key Laboratory of Optoelectronic Detection Technology and System, School of Electronic and Information Engineering, Tiangong University, Tianjin, 300387, China
| | - Ke Yang
- Department of Cardiovascular Surgery, General Hospital of Western Theater Command (Chengdu Military General Hospital), Chengdu, 610036, China.
| | - Xianguo Li
- Tianjin Key Laboratory of Optoelectronic Detection Technology and System, School of Electronic and Information Engineering, Tiangong University, Tianjin, 300387, China
| | - Cuijuan Guo
- Tianjin Key Laboratory of Optoelectronic Detection Technology and System, School of Electronic and Information Engineering, Tiangong University, Tianjin, 300387, China
| | - Hua Bai
- Tianjin Key Laboratory of Optoelectronic Detection Technology and System, School of Electronic and Information Engineering, Tiangong University, Tianjin, 300387, China
| | - Weiling Fu
- Department of Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, 400038, China
| | - Pingjuan Niu
- Tianjin Key Laboratory of Optoelectronic Detection Technology and System, School of Electronic and Information Engineering, Tiangong University, Tianjin, 300387, China
| | - Jianquan Yao
- Key Laboratory of Opto-Electronics Information Technology (Ministry of Education), School of Precision Instruments and Opto-Electronic Engineering, Tianjin University, Tianjin, 300072, China
| | - Xiang Yang
- Department of Laboratory Medicine, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, 400038, China.
| |
Collapse
|
2
|
Aguilar-Torrejón JA, Balderas-Hernández P, Roa-Morales G, Barrera-Díaz CE, Rodríguez-Torres I, Torres-Blancas T. Relationship, importance, and development of analytical techniques: COD, BOD, and, TOC in water—An overview through time. SN APPLIED SCIENCES 2023. [DOI: 10.1007/s42452-023-05318-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023] Open
Abstract
AbstractAnalytical techniques to measure organic matter in water, such as Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD5), and Total Organic Carbon (TOC) are widely used. Modifications have been proposed to make them faster, more sensitive, and more environmentally friendly. The purpose of producing a review over some time is to show the changes made on the standardized methods of each of these techniques, and to highlight the relationship between them in the process of ascertaining organic matter in water. Modifications to techniques COD and BOD entail several factors that need to be considered, namely: time, miniaturization, sensitivity, use of environmentally friendly reagents. Changes to TOC are focused on detection systems. Despite the advantages obtained by the modified techniques, traditional methods continue to be widely used, in most cases due to the lack of standardization of the new methods.
Graphic Abstract
Collapse
|
3
|
Thakur A, Devi P. A Comprehensive Review on Water Quality Monitoring Devices: Materials Advances, Current Status, and Future Perspective. Crit Rev Anal Chem 2022; 54:193-218. [PMID: 35522585 DOI: 10.1080/10408347.2022.2070838] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2022]
Abstract
Water quality monitoring has become more critical in recent years to ensure the availability of clean and safe water from natural aquifers and to understand the evolution of water contaminants across time and space. The conventional water monitoring techniques comprise of sample collection, preservation, preparation, tailed by laboratory testing and analysis with cumbersome wet chemical routes and expensive instrumentation. Despite the high accuracy of these methods, the high testing costs, laborious procedures, and maintenance associated with them don't make them lucrative for end end-users and field testing. As the participation of ultimate stakeholders, that is, common man for water quality and quantity can play a pivotal role in ensuring the sustainability of our aquifers, thus it is essential to develop and deploy portable and user-friendly technical systems for monitoring water sources in real-time or on-site. The present review emphasizes here on possible approaches including optical (absorbance, fluorescence, colorimetric, X-ray fluorescence, chemiluminescence), electrochemical (ASV, CSV, CV, EIS, and chronoamperometry), electrical, biological, and surface-sensing (SPR and SERS), as candidates for developing such platforms. The existing developments, their success, and bottlenecks are discussed in terms of various attributes of water to escalate the essentiality of water quality devices development meeting ASSURED criterion for societal usage. These platforms are also analyzed in terms of their market potential, advancements required from material science aspects, and possible integration with IoT solutions in alignment with Industry 4.0 for environmental application.
Collapse
Affiliation(s)
- Anupma Thakur
- Materials Science and Sensor Application, CSIR-Central Scientific Instruments Organisation, Chandigarh, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India
| | - Pooja Devi
- Materials Science and Sensor Application, CSIR-Central Scientific Instruments Organisation, Chandigarh, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India
| |
Collapse
|
4
|
Rai D, Sinha S. Research trends in the development of anodes for electrochemical oxidation of wastewater. REV CHEM ENG 2022. [DOI: 10.1515/revce-2021-0067] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Abstract
The review focuses on the recent development in anode materials and their synthesis approach, focusing on their compatibility for treating actual industrial wastewater, improving selectivity, electrocatalytic activity, stability at higher concentration, and thereby reducing the mineralization cost for organic pollutant degradation. The advancement in sol–gel technique, including the Pechini method, is discussed in the first section. A separate discussion related to the selection of the electrodeposition method and its deciding parameters is also included. Furthermore, the effect of using advanced heating approaches, including microwave and laser deposition synthesis, is also discussed. Next, a separate discussion is provided on using different types of anode materials and their effect on active •OH radical generation, activity, and electrode stability in direct and indirect oxidation and future aspects. The effect of using different synthesis approaches, additives, and doping is discussed separately for each anode. Graphene, carbon nanotubes (CNTs), and metal doping enhance the number of active sites, electrochemical activity, and mineralization current efficiency (MCE) of the anode. While, microwave or laser heating approaches were proved to be an effective, cheaper, and fast alternative to conventional heating. The electrodeposition and nonaqueous solvent synthesis were convenient and environment-friendly techniques for conductive metallic and polymeric film deposition.
Collapse
Affiliation(s)
- Devendra Rai
- Department of Chemical Engineering , Indian Institute of Technology Roorkee , Roorkee , Uttarakhand 247667 , India
| | - Shishir Sinha
- Department of Chemical Engineering , Indian Institute of Technology Roorkee , Roorkee , Uttarakhand 247667 , India
| |
Collapse
|
5
|
Trojanowicz M, Pyszynska M. Flow-Injection Methods in Water Analysis-Recent Developments. Molecules 2022; 27:1410. [PMID: 35209198 PMCID: PMC8879103 DOI: 10.3390/molecules27041410] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 02/11/2022] [Accepted: 02/15/2022] [Indexed: 12/10/2022] Open
Abstract
Widespread demand for the analysis and control of water quality and supply for human activity and ecosystem sustainability has necessitated the continuous improvement of water analysis methods in terms of their reliability, efficiency, and costs. To satisfy these requirements, flow-injection analysis using different detection methods has successfully been developed in recent decades. This review, based on about 100 original research papers, presents the achievements in this field over the past ten years. Various methodologies for establishing flow-injection measurements are reviewed, together with microfluidics and portable systems. The developed applications mostly concern not only the determination of inorganic analytes but also the speciation analysis of different elements, and the determination of several total indices of water quality. Examples of the determination of organic residues (e.g., pesticides, phenolic compounds, and surfactants) in natural surface waters, seawater, groundwater, and drinking water have also been identified. Usually, changes in the format of manual procedures for flow-injection determination results in the improvement of various operational parameters, such as the limits of detection, the sampling rate, or selectivity in different matrices.
Collapse
Affiliation(s)
- Marek Trojanowicz
- Laboratory of Nuclear Analytical Methods, Institute of Nuclear Chemistry and Technology, Dorodna 16, 02-195 Warsaw, Poland;
- Department of Chemistry, University of Warsaw, Pasteura 1, 02-093 Warsaw, Poland
| | - Marta Pyszynska
- Laboratory of Nuclear Analytical Methods, Institute of Nuclear Chemistry and Technology, Dorodna 16, 02-195 Warsaw, Poland;
| |
Collapse
|
6
|
Mahmoud EN, Fayed FY, Ibrahim KM, Jaafreh S. Removal of Cadmium, Copper, and Lead From Water Using Bio-Sorbent From Treated Olive Mill Solid Residue. ENVIRONMENTAL HEALTH INSIGHTS 2021; 15:11786302211053176. [PMID: 34707362 PMCID: PMC8543703 DOI: 10.1177/11786302211053176] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Accepted: 09/24/2021] [Indexed: 05/10/2023]
Abstract
Olive Mill Solid Residue (OMSR) can be utilized as a bio-sorbent in wastewater treatment. Even though several studies on OMSR as a bio-sorbent were carried out, there is still a need to investigate a simple and relatively inexpensive OMSR treatment that increases pollutant removal. In this study; OMSR is used in batch experiments to remove toxic heavy metals from aqueous solutions including Cd2+, Cu2+, and Pb2+ ions. The effect of OMSR treatment (untreated; OMSR-U, treated with n-hexane; OMSR-H, and treated with water; OMSR-W) was investigated by chemical oxygen demand and cation exchange capacity. It was confirmed by both tests that OMSR-W was the best treatment. The same result was re-confirmed by batch uptake experiments of the heavy metal ions. Using OMSR-W as a bio-sorbent; the effect of several parameters such as pH, contact time, bio-sorbent concentration, metal ions concentration, and the presence of other metal species were studied to figure their influence on the metal ions uptake. The optimum conditions for single metal systems were found to occur at pH 5.5, an initial metal concentration of 50 mg/L, a shaking time of 60 minutes, a bio-sorbent concentration of 20 g/L. In binary metal ions solutions; Cd2+ uptake was increased in presence of Cu2+ or Pb2+. However, the uptake of Cu2+ and Pb2+ was decreased in presence of other metals. The equilibrium sorption data for single metal systems were described by the Langmuir isotherm model. The highest value of maximum uptake was found for Pb2+ (4.587 mg/g) followed by Cd2+ (4.525 mg/g) and Cu2+ (4.367 mg/g). These results show that OMSR-W, which has a very low economical value, could be used for the treatment of wastewater contaminated with heavy metals.
Collapse
Affiliation(s)
- Enas N Mahmoud
- Department of Chemistry, Faculty of
Science, The Hashemite University, Zarqa, Jordan
| | - Fidaa’ Y Fayed
- Department of Earth Sciences and
Environment, Prince El-Hassan bin Talal Faculty for Natural Resources and
Environment, The Hashemite University, Zarqa, Jordan
| | - Khalil M Ibrahim
- Department of Earth Sciences and
Environment, Prince El-Hassan bin Talal Faculty for Natural Resources and
Environment, The Hashemite University, Zarqa, Jordan
| | - Sawsan Jaafreh
- Department of Chemistry, Faculty of
Science, The Hashemite University, Zarqa, Jordan
- Sawsan Jaafreh, Department of Chemistry,
Faculty of Science, The Hashemite University, P.O. Box 330127, Zarqa 13133,
Jordan.
| |
Collapse
|
7
|
Biosensors for wastewater monitoring: A review. Biosens Bioelectron 2018; 118:66-79. [PMID: 30056302 DOI: 10.1016/j.bios.2018.07.019] [Citation(s) in RCA: 89] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2018] [Revised: 07/07/2018] [Accepted: 07/09/2018] [Indexed: 02/06/2023]
Abstract
Water pollution and habitat degradation are the cause of increasing water scarcity and decline in aquatic biodiversity. While the freshwater availability has been declining through past decades, water demand has continued to increase particularly in areas with arid and semi-arid climate. Monitoring of pollutants in wastewater effluents are critical to identifying water pollution area for treatment. Conventional detection methods are not effective in tracing multiple harmful components in wastewater due to their variability along different times and sources. Currently, the development of biosensing instruments attracted significant attention because of their high sensitivity, selectivity, reliability, simplicity, low-cost and real-time response. This paper provides a general overview on reported biosensors, which have been applied for the recognition of important organic chemicals, heavy metals, and microorganisms in dark waters. The significance and successes of nanotechnology in the field of biomolecular detection are also reviewed. The commercially available biosensors and their main challenges in wastewater monitoring are finally discussed.
Collapse
|
8
|
Zulkifli SN, Rahim HA, Lau WJ. Detection of contaminants in water supply: A review on state-of-the-art monitoring technologies and their applications. SENSORS AND ACTUATORS. B, CHEMICAL 2018; 255:2657-2689. [PMID: 32288249 PMCID: PMC7126548 DOI: 10.1016/j.snb.2017.09.078] [Citation(s) in RCA: 71] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2016] [Revised: 08/22/2017] [Accepted: 09/13/2017] [Indexed: 05/12/2023]
Abstract
Water monitoring technologies are widely used for contaminants detection in wide variety of water ecology applications such as water treatment plant and water distribution system. A tremendous amount of research has been conducted over the past decades to develop robust and efficient techniques of contaminants detection with minimum operating cost and energy. Recent developments in spectroscopic techniques and biosensor approach have improved the detection sensitivities, quantitatively and qualitatively. The availability of in-situ measurements and multiple detection analyses has expanded the water monitoring applications in various advanced techniques including successful establishment in hand-held sensing devices which improves portability in real-time basis for the detection of contaminant, such as microorganisms, pesticides, heavy metal ions, inorganic and organic components. This paper intends to review the developments in water quality monitoring technologies for the detection of biological and chemical contaminants in accordance with instrumental limitations. Particularly, this review focuses on the most recently developed techniques for water contaminant detection applications. Several recommendations and prospective views on the developments in water quality assessments will also be included.
Collapse
Affiliation(s)
| | - Herlina Abdul Rahim
- Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia
| | - Woei-Jye Lau
- Advanced Membrane Technology Research Centre (AMTEC), Faculty of Chemical and Energy Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia
| |
Collapse
|
9
|
|
10
|
Mursalim LO, Ruslan AM, Safitri RA, Azis T, Maulidiyah, Wibowo D, Nurdin M. Synthesis and Photoelectrocatalytic Performance of Mn-N-TiO2/Ti Electrode for Electrochemical Sensor. ACTA ACUST UNITED AC 2017. [DOI: 10.1088/1757-899x/267/1/012006] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
11
|
Costa SPF, Pereira SAP, Pinto PCAG, Araujo ARTS, Passos MLC, Saraiva MLMFS. Environmental Impact of Ionic Liquids: Automated Evaluation of the Chemical Oxygen Demand of Photochemically Degraded Compounds. Chemphyschem 2017; 18:1351-1357. [DOI: 10.1002/cphc.201601416] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2016] [Indexed: 11/05/2022]
Affiliation(s)
- Susana P. F. Costa
- LAQV, Requimte, Departamento de Ciências Químicas, Laboratório de Química Aplicada, Faculdade de Farmácia; Universidade do Porto; Rua Jorge Viterbo Ferreira, 228 4050-313 Porto Portugal
| | - Sarah A. P. Pereira
- LAQV, Requimte, Departamento de Ciências Químicas, Laboratório de Química Aplicada, Faculdade de Farmácia; Universidade do Porto; Rua Jorge Viterbo Ferreira, 228 4050-313 Porto Portugal
- Unidade de Investigação para o Desenvolvimento do Interior; Instituto Politécnico da Guarda; Av. Dr. Francisco de Sá Carneiro, n° 50 6300-559 Guarda Portugal
| | - Paula C. A. G. Pinto
- LAQV, Requimte, Departamento de Ciências Químicas, Laboratório de Química Aplicada, Faculdade de Farmácia; Universidade do Porto; Rua Jorge Viterbo Ferreira, 228 4050-313 Porto Portugal
- A3D-Association for Drug Discovery and Development; Rua do Baixeiro n° 38 Aveiro Portugal
| | - André R. T. S. Araujo
- LAQV, Requimte, Departamento de Ciências Químicas, Laboratório de Química Aplicada, Faculdade de Farmácia; Universidade do Porto; Rua Jorge Viterbo Ferreira, 228 4050-313 Porto Portugal
- Unidade de Investigação para o Desenvolvimento do Interior; Instituto Politécnico da Guarda; Av. Dr. Francisco de Sá Carneiro, n° 50 6300-559 Guarda Portugal
| | - Marieta L. C. Passos
- LAQV, Requimte, Departamento de Ciências Químicas, Laboratório de Química Aplicada, Faculdade de Farmácia; Universidade do Porto; Rua Jorge Viterbo Ferreira, 228 4050-313 Porto Portugal
| | - M. Lúcia M. F. S. Saraiva
- LAQV, Requimte, Departamento de Ciências Químicas, Laboratório de Química Aplicada, Faculdade de Farmácia; Universidade do Porto; Rua Jorge Viterbo Ferreira, 228 4050-313 Porto Portugal
| |
Collapse
|
12
|
Abstract
A dynamic development of methodologies of analytical flow injection measurements during four decades since their invention has reinforced the solid position of flow analysis in the arsenal of techniques and instrumentation of contemporary chemical analysis.
Collapse
Affiliation(s)
- Marek Trojanowicz
- Laboratory of Nuclear Analytical Methods
- Institute of Nuclear Chemistry and Technology
- 03-195 Warsaw
- Poland
- Department of Chemistry
| | - Kamila Kołacińska
- Laboratory of Nuclear Analytical Methods
- Institute of Nuclear Chemistry and Technology
- 03-195 Warsaw
- Poland
| |
Collapse
|