Acerbi F, Merzi S, Gola A. Position-Sensitive Silicon Photomultiplier Arrays with Large-Area and Sub-Millimeter Resolution. SENSORS (BASEL, SWITZERLAND) 2024; 24:4507. [PMID: 39065904 PMCID: PMC11280990 DOI: 10.3390/s24144507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2024] [Revised: 07/03/2024] [Accepted: 07/10/2024] [Indexed: 07/28/2024]
Abstract
Silicon photomultipliers (SiPMs) are solid-state single-photon-sensitive detectors that show excellent performance in a wide range of applications. In FBK (Trento, Italy), we developed a position-sensitive SiPM technology, called "linearly graded" (LG-SiPM), which is based on an avalanche-current weighted-partitioning approach. It shows position reconstruction resolution below 250 μm on an 8 × 8 mm2 device area with four readout channels and minimal distortions. A recent development in terms of LG-SIPM is a larger chip version (10 × 10 mm2) based on FBK NUV-HD technology (near-ultraviolet sensitive), with a peak photon detection efficiency at 420 nm. Such a large-area detector with position sensitivity is very interesting in applications like MR-compatible PET, high-energy physics experiments, and readout of time-projection chambers, gamma and beta cameras, or scintillating fibers, with a reduced number of channels. These SiPMs were characterized in terms of noise, photon detection efficiency, and position resolution. We also developed tiles of 2 × 2 and 3 × 3 LG-SiPMs, reaching very large sensitive areas of 20 × 20 mm2 and 30 × 30 mm2. We implemented a "smart-channel" configuration, which allowed us to have just six output channels for the 2 × 2 elements and eight channels for the 3 × 3 element tiles, preserving a position resolution below 0.5 mm. These kinds of detectors provide a great advantage in compact and low-power applications by maintaining position sensitivity over large areas with a small number of channels.
Collapse
Affiliation(s)
- Fabio Acerbi
- Fondazione Bruno Kessler (FBK), Via Sommarive 18, I-38123 Trento, Italy; (S.M.); (A.G.)
| | | | | |
Collapse
|
2
|
Pollard AC, de la Cerda J, Schuler FW, Kingsley CV, Gammon ST, Pagel MD. Evaluations of the performances of PET and MRI in a simultaneous PET/MRI instrument for pre-clinical imaging. EJNMMI Phys 2022; 9:70. [PMID: 36209262 PMCID: PMC9547760 DOI: 10.1186/s40658-022-00483-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Accepted: 08/08/2022] [Indexed: 11/15/2022] Open
Abstract
Background PET/MRI is an attractive imaging modality due to the complementary nature of MRI and PET. Obtaining high quality small animal PET/MRI results is key for the translation of novel PET/MRI agents and techniques to the radiology clinic. To obtain high quality imaging results, a hybrid PET/MRI system requires additional considerations beyond the standard issues with separate PET and MRI systems. In particular, researchers must understand how their PET system affects the MR acquisitions and vice versa. Depending on the application, some of these effects may substantially influence image quality. Therefore, the goal of this report is to provide guidance, recommendations, and practical experiments for implementing and using a small animal PET/MRI instrument. Results Various PET and MR image quality parameters were tested with their respective modality alone and in the presence of both systems to determine how the combination of PET/MRI affects image quality. Corrections and calibrations were developed for many of these effects. While not all image characteristics were affected, some characteristics such as PET quantification, PET SNR, PET spatial resolution, PET partial volume effects, and MRI SNR were altered by the presence of both systems. Conclusions A full exploration of a new PET/MRI system before performing small animal PET/MRI studies is beneficial and necessary to ensure that the new instrument can produce highly accurate and precise PET/MR images. Supplementary Information The online version contains supplementary material available at 10.1186/s40658-022-00483-x.
Collapse
Affiliation(s)
- Alyssa C Pollard
- Department of Chemistry, Rice University, Houston, TX, USA.,Department of Cancer Systems Imaging, MD Anderson Cancer Center, Houston, TX, USA
| | - Jorge de la Cerda
- Department of Cancer Systems Imaging, MD Anderson Cancer Center, Houston, TX, USA
| | - F William Schuler
- Department of Cancer Systems Imaging, MD Anderson Cancer Center, Houston, TX, USA
| | - Charles V Kingsley
- Department of Imaging Physics, MD Anderson Cancer Center, Houston, TX, USA
| | - Seth T Gammon
- Department of Cancer Systems Imaging, MD Anderson Cancer Center, Houston, TX, USA
| | - Mark D Pagel
- Department of Cancer Systems Imaging, MD Anderson Cancer Center, Houston, TX, USA.
| |
Collapse
|
3
|
Frangos S, Michael K, Exadaktylou P, Giannoula E, Iakovou I. The Anger's camera. Nucl Med Mol Imaging 2022. [DOI: 10.1016/b978-0-12-822960-6.00159-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
4
|
Deng Z, Deng Y, Chen G. Design and Evaluation of LYSO/SiPM LIGHTENING PET Detector with DTI Sampling Method. SENSORS (BASEL, SWITZERLAND) 2020; 20:E5820. [PMID: 33076244 PMCID: PMC7650676 DOI: 10.3390/s20205820] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Revised: 10/03/2020] [Accepted: 10/12/2020] [Indexed: 05/08/2023]
Abstract
Positron emission tomography (PET) has a wide range of applications in the treatment and prevention of major diseases owing to its high sensitivity and excellent resolution. However, there is still much room for optimization in the readout circuit and fast pulse sampling to further improve the performance of the PET scanner. In this work, a LIGHTENING® PET detector using a 13 × 13 lutetium-yttrium oxyorthosilicate (LYSO) crystal array read out by a 6 × 6 silicon photomultiplier (SiPM) array was developed. A novel sampling method, referred to as the dual time interval (DTI) method, is therefore proposed to realize digital acquisition of fast scintillation pulse. A semi-cut light guide was designed, which greatly improves the resolution of the edge region of the crystal array. The obtained flood histogram shown that all the 13 × 13 crystal pixels can be clearly discriminated. The optimum operating conditions for the detector were obtained by comparing the flood histogram quality under different experimental conditions. An average energy resolution (FWHM) of 14.3% and coincidence timing resolution (FWHM) of 972 ps were measured. The experimental results demonstrated that the LIGHTENING® PET detector achieves extremely high resolution which is suitable for the development of a high performance time-of-flight PET scanner.
Collapse
Affiliation(s)
- Zhenzhou Deng
- School of Information Engineering, Nanchang University, Nanchang 330031, China; (Y.D.); (G.C.)
| | | | | |
Collapse
|
5
|
Quantum Calibration of Photon-Number-Resolving Detectors Based on Multi-pixel Photon Counters. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9132638] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
In this paper, we reconstructed the positive operator-valued measure (POVM) of a photon-number-resolving detector (PNRD) based on a multi-pixel photon counter (MPPC) by means of quantum detector tomography (QDT) at 791 nm and 523 nm, respectively. MPPC is a kind of spatial-multiplexing PNRD with a silicon avalanche photodiode (Si-APD) array as the photon receiver. Experimentally, the quantum characteristics of MPPC were calibrated at 2 MHz at two different wavelengths. The POVM elements were given by QDT. The fidelity of the reconstructed POVM elements is higher than 99.96%, which testifies that the QDT is reliable to calibrate MPPC at different wavelengths. With QDT and associated Wigner functions, the quantum properties of MPPC can be calibrated more directly and accurately in contrast with those conventional methods of modeling detectors.
Collapse
|
6
|
Van Elburg DJ, Shrestha R, Goertzen AL. Towards a second-generation PET/MR insert with enhanced timing and count rate performance. Phys Med Biol 2019; 64:085017. [PMID: 30861504 DOI: 10.1088/1361-6560/ab0efa] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Previously we have developed a first-generation PET insert prototype for small animal PET/MR imaging, which used resistor-based charge division multiplexing circuits and SensL B-series silicon photomultipliers (SiPMs). In this work we present results from a second-generation readout board with improved timing and count rate performance. Three detector boards were tested: the first-generation readout board with SensL SPMArray4B (SiPM-B), the second-generation readout board with SensL ArrayC-30035-16P-PCB (SiPM-C) using the 'fast' outputs for timing, and the second generation board using Hamamatsu S11361-3050AE-04 MPPC arrays. Timing data were obtained with detector modules in coincidence with a single-pixel SensL MicroFJ-SMA-30035 reference detector and acquired using standard NIM electronics, while count rate data were acquired using the OpenPET data acquisition electronics system. The full-width at half-maximum (FWHM) coincidence time resolution (CTR) for the SiPM-B, SiPM-C and MPPC designs were 2600 ± 200 ps, 550 ± 50 ps, and 570 ± 30 ps, respectively. OpenPET waveform capture determined the mean signal durations, measured as time above 10% of the maximum amplitude, were 1850 ± 150 ns, 600 ± 25 ns, and 350 ± 25 ns, respectively, where the short signal of the MPPC resulted in reduced pileup effects at higher count rates. Decaying source measurements showed a non-paralyzable dead time of 1.30-1.41 µs for all three detectors tested, which was limited by the signal capture and processing time of the OpenPET system.
Collapse
Affiliation(s)
- Devin J Van Elburg
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB R3T 2N2, Canada. Department of Physics and Astronomy, University of Calgary, Calgary, AB T2N 1N4, Canada
| | | | | |
Collapse
|
7
|
Parl C, Kolb A, Stricker-Shaver D, Pichler BJ. Dual layer doI detector modules for a dedicated mouse brain PET/MRI. Phys Med Biol 2019; 64:055004. [PMID: 30654339 DOI: 10.1088/1361-6560/aaff73] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
The outcome of preclinical imaging studies are enhanced by simultaneous, high-resolution anatomical and molecular data, which advanced PET/MRI systems provide. Nevertheless, mapping of neuroreceptors and accurate quantification of PET tracer distribution in mouse brains is not trivial. The restricted spatial resolution and sensitivity in commercial animal PET systems limits the image quality and the quantification accuracy. We are currently developing a PET/MRI system dedicated for mouse brain studies. The PET system will offer system dimensions of approx. 30 mm in diameter and an axial length of more than 38 mm. This work discusses two system geometries including their associated block detectors. Both configurations were based on a dual layer offset structure with small crystals sizes, in the order of 1 × 1 × 4/6 mm3, to provide discrete depth of interaction information. The detector for configuration 'A' was based on a 4 × 4 silicon photomultiplier (SiPM) array attached to an optical diffusor, and a 12 × 12 as well as a 9 × 11 LSO crystal array, to achieve optimal system sensitivity. This configuration was evaluated by a double layer of 12 × 12 crystals. Configuration 'B' was composed of three 2 × 2 SiPM arrays equipped with a 1 mm diffusor to read out an LSO stack of 20 × 6 and 19 × 5 individual crystals. The average peak-to-valley ratio of the inner/outer layer was 3.5/3.6 for detector 'A', and 3.4/2.8 for detector 'B'. The average full width at half maximum (FWHM) energy resolution of the block detectors were 22.24% ± 3.36% for 'A' and 30.67% ± 5.37% for 'B'. The FWHM of the full block timing resolution of the inner/outer layer was 1.4 ns/1.2 ns for detector 'A' and 1.8 ns/1.4 ns for 'B'. The performance of the crystal position profile, the energy, and timing resolution indicate that configuration 'A' is more appropriate for a mouse brain PET/MRI system.
Collapse
Affiliation(s)
- C Parl
- Department of Preclinical Imaging and Radiopharmacy, Werner Siemens Imaging Center, Eberhard Karls University Tuebingen, Roentgenweg 13, 72076 Tuebingen, Germany
| | | | | | | |
Collapse
|
8
|
Raylman RR, Ledden P, Stolin AV, Hou B, Jaliparthi G, Martone PF. Small animal, positron emission tomography-magnetic resonance imaging system based on a clinical magnetic resonance imaging scanner: evaluation of basic imaging performance. J Med Imaging (Bellingham) 2018; 5:033504. [PMID: 30840723 DOI: 10.1117/1.jmi.5.3.033504] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Accepted: 08/14/2018] [Indexed: 11/14/2022] Open
Abstract
Development of advanced preclinical imaging techniques has had an important impact on the field of biomedical research, with positron emission tomography (PET) imaging the most mature of these efforts. Developers of preclinical PET scanners have joined the recent multimodality imaging trend by combining PET imaging with other modalities, such as magnetic resonance imaging (MRI). Our group has developed a combined PET-MRI insert for the imaging of animals up to the size of rats in a clinical 3T MRI scanner. The system utilizes a sequential scanner configuration instead of the more common coplanar geometry. The PET component of the system consists of a ring of 12 liquid-cooled, SiPM-based detector modules ( diameter = 15.2 cm ). System performance was evaluated with the NEMA NU 4-2008 protocol. Spatial resolution is ∼ 1.71 mm 5 cm from the center of the field-of-view measured from single-slice rebinned filtered backprojection-reconstructed images. Peak noise equivalent count rate is 17.7 kcps at 8.5 MBq; peak sensitivity is 2.9%. The MRI component of the system is composed of a 12-cm-diameter birdcage transmit/receive coil with a dual-preamplifier interface possessing very low noise preamplifiers. System performance was evaluated using American College of Radiology-based methods. Image homogeneity is 99%; the ghosting ratio is 0.0054. The signal-to-noise ratio is 95 and spatial resolution is ∼ 0.25 mm . There was no discernable cross-modality interference.
Collapse
Affiliation(s)
- Raymond R Raylman
- West Virginia University, Center for Advanced Imaging, Department of Radiology, Morgantown, West Virginia, United States
| | - Patrick Ledden
- Nova Medical Inc., Wilmington, Massachusetts, United States
| | - Alexander V Stolin
- West Virginia University, Center for Advanced Imaging, Department of Radiology, Morgantown, West Virginia, United States
| | - Bob Hou
- West Virginia University, Center for Advanced Imaging, Department of Radiology, Morgantown, West Virginia, United States
| | - Ganghadar Jaliparthi
- West Virginia University, Center for Advanced Imaging, Department of Radiology, Morgantown, West Virginia, United States
| | - Peter F Martone
- West Virginia University, Center for Advanced Imaging, Department of Radiology, Morgantown, West Virginia, United States
| |
Collapse
|
9
|
Cabello J, Ziegler SI. Advances in PET/MR instrumentation and image reconstruction. Br J Radiol 2018; 91:20160363. [PMID: 27376170 PMCID: PMC5966194 DOI: 10.1259/bjr.20160363] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2016] [Revised: 06/26/2016] [Accepted: 06/29/2016] [Indexed: 12/15/2022] Open
Abstract
The combination of positron emission tomography (PET) and MRI has attracted the attention of researchers in the past approximately 20 years in small-animal imaging and more recently in clinical research. The combination of PET/MRI allows researchers to explore clinical and research questions in a wide number of fields, some of which are briefly mentioned here. An important number of groups have developed different concepts to tackle the problems that PET instrumentation poses to the exposition of electromagnetic fields. We have described most of these research developments in preclinical and clinical experiments, including the few commercial scanners available. From the software perspective, an important number of algorithms have been developed to address the attenuation correction issue and to exploit the possibility that MRI provides for motion correction and quantitative image reconstruction, especially parametric modelling of radiopharmaceutical kinetics. In this work, we give an overview of some exemplar applications of simultaneous PET/MRI, together with technological hardware and software developments.
Collapse
Affiliation(s)
- Jorge Cabello
- Nuklearmedizinische Klinik und Poliklinik, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
| | - Sibylle I Ziegler
- Nuklearmedizinische Klinik und Poliklinik, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
| |
Collapse
|
10
|
Goertzen AL, Shrestha R, Khan MS, Stortz G, Bishop D, Kozlowski P, Retiere F, Thiessen JD, Thompson CJ, Sossi V. Data Acquisition for a Preclinical MR Compatible PET Insert Using the OpenPET Platform. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2017. [DOI: 10.1109/trpms.2017.2747407] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
11
|
Loignon-Houle F, Bergeron M, Pepin CM, Charlebois SA, Lecomte R. Simulation of scintillation light output in LYSO scintillators through a full factorial design. Phys Med Biol 2017; 62:669-683. [DOI: 10.1088/1361-6560/62/2/669] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
12
|
Thiessen JD, Shams E, Stortz G, Schellenberg G, Bishop D, Khan MS, Kozlowski P, Retière F, Sossi V, Thompson CJ, Goertzen AL. MR-compatibility of a high-resolution small animal PET insert operating inside a 7 T MRI. Phys Med Biol 2016; 61:7934-7956. [DOI: 10.1088/0031-9155/61/22/7934] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
13
|
A Readout IC Using Two-Step Fastest Signal Identification for Compact Data Acquisition of PET Systems. SENSORS 2016; 16:s16101748. [PMID: 27775623 PMCID: PMC5087533 DOI: 10.3390/s16101748] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2016] [Revised: 10/10/2016] [Accepted: 10/17/2016] [Indexed: 11/22/2022]
Abstract
A readout integrated circuit (ROIC) using two-step fastest signal identification (FSI) is proposed to reduce the number of input channels of a data acquisition (DAQ) block with a high-channel reduction ratio. The two-step FSI enables the proposed ROIC to filter out useless input signals that arise from scattering and electrical noise without using complex and bulky circuits. In addition, an asynchronous fastest signal identifier and a self-trimmed comparator are proposed to identify the fastest signal without using a high-frequency clock and to reduce misidentification, respectively. The channel reduction ratio of the proposed ROIC is 16:1 and can be extended to 16 × N:1 using N ROICs. To verify the performance of the two-step FSI, the proposed ROIC was implemented into a gamma photon detector module using a Geiger-mode avalanche photodiode with a lutetium-yttrium oxyorthosilicate array. The measured minimum detectable time is 1 ns. The difference of the measured energy and timing resolution between with and without the two-step FSI are 0.8% and 0.2 ns, respectively, which are negligibly small. These measurement results show that the proposed ROIC using the two-step FSI reduces the number of input channels of the DAQ block without sacrificing the performance of the positron emission tomography (PET) systems.
Collapse
|
14
|
Schellenberg G, Stortz G, Goertzen AL. An algorithm for automatic crystal identification in pixelated scintillation detectors using thin plate splines and Gaussian mixture models. Phys Med Biol 2016; 61:N90-N101. [PMID: 26794058 DOI: 10.1088/0031-9155/61/3/n90] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A typical positron emission tomography detector is comprised of a scintillator crystal array coupled to a photodetector array or other position sensitive detector. Such detectors using light sharing to read out crystal elements require the creation of a crystal lookup table (CLUT) that maps the detector response to the crystal of interaction based on the x-y position of the event calculated through Anger-type logic. It is vital for system performance that these CLUTs be accurate so that the location of events can be accurately identified and so that crystal-specific corrections, such as energy windowing or time alignment, can be applied. While using manual segmentation of the flood image to create the CLUT is a simple and reliable approach, it is both tedious and time consuming for systems with large numbers of crystal elements. In this work we describe the development of an automated algorithm for CLUT generation that uses a Gaussian mixture model paired with thin plate splines (TPS) to iteratively fit a crystal layout template that includes the crystal numbering pattern. Starting from a region of stability, Gaussians are individually fit to data corresponding to crystal locations while simultaneously updating a TPS for predicting future Gaussian locations at the edge of a region of interest that grows as individual Gaussians converge to crystal locations. The algorithm was tested with flood image data collected from 16 detector modules, each consisting of a 409 crystal dual-layer offset LYSO crystal array readout by a 32 pixel SiPM array. For these detector flood images, depending on user defined input parameters, the algorithm runtime ranged between 17.5-82.5 s per detector on a single core of an Intel i7 processor. The method maintained an accuracy above 99.8% across all tests, with the majority of errors being localized to error prone corner regions. This method can be easily extended for use with other detector types through adjustment of the initial template model used.
Collapse
Affiliation(s)
- Graham Schellenberg
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, Canada
| | | | | |
Collapse
|
15
|
|