1
|
Smartphone-based wound dressings: A mini-review. Heliyon 2022; 8:e09876. [PMID: 35832346 PMCID: PMC9272343 DOI: 10.1016/j.heliyon.2022.e09876] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 03/05/2022] [Accepted: 06/30/2022] [Indexed: 01/13/2023] Open
Abstract
In spite of remarkable progress in the field of wound curation, treatment of chronic wounds remains a challenge for medical services. The constant rise in the number of patients with chronic wounds and their related financial burden has caused concern for the healthcare system. The complicated and dynamic nature of chronic wounds has increased the curation time and difficulty of wound healing with conventional bandages. Efficient healing of these wounds requires new bandages with the ability of real-time monitoring, data analysis, and drug delivery, which protect the wound against infection and accelerate the treatment process. The recent development of smartphone applications and digital equipment in medicine provides an opportunity for significant improvement in wound care through the incorporation of “smart” technologies into clinical practice. The focus of this review is to provide an overview of the current status of smartphones and digital technology in the management of wounds.
Collapse
|
2
|
Developing Wound Moisture Sensors: Opportunities and Challenges for Laser-Induced Graphene-Based Materials. JOURNAL OF COMPOSITES SCIENCE 2022. [DOI: 10.3390/jcs6060176] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Recent advances in polymer composites have led to new, multifunctional wound dressings that can greatly improve healing processes, but assessing the moisture status of the underlying wound site still requires frequent visual inspection. Moisture is a key mediator in tissue regeneration and it has long been recognised that there is an opportunity for smart systems to provide quantitative information such that dressing selection can be optimised and nursing time prioritised. Composite technologies have a rich history in the development of moisture/humidity sensors but the challenges presented within the clinical context have been considerable. This review aims to train a spotlight on existing barriers and highlight how laser-induced graphene could lead to emerging material design strategies that could allow clinically acceptable systems to emerge.
Collapse
|
3
|
Kruanopparat R. Pressure-Measuring Devices for Compression Therapy in Venous Leg Ulcers: A Comprehensive Review. Adv Skin Wound Care 2021; 34:1-6. [PMID: 34415258 DOI: 10.1097/01.asw.0000767324.54122.67] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To investigate the evolution of pressure-measuring devices used in compression treatment for venous leg ulcers and assess the most practical and effective devices to determine optimal pressure in compression therapy. DATA SOURCES Relevant information was retrieved from databases including Google Scholar, PubMed, Wiley Online, and ScienceDirect without publication date restrictions. The keywords included venous leg ulcer, compression therapy, pressure measuring device, pressure sensor, and wireless system. STUDY SELECTION Studies included in the review had to be published in English and discuss or compare pressure-measuring devices/sensors for compression therapy, the development of alternative sensors, and the applications of wireless technologies. Veterinary studies, conference proceedings, and unpublished articles were excluded. Applicable studies and articles were critically evaluated and synthesized. DATA EXTRACTION After abstract review, 39 studies were identified. During full-text review, study details were collected using a data extraction form and organized into tables. Device attributes, accuracy, price, and limitations were categorized and analyzed. DATA SYNTHESIS Studies disagree on the effectiveness and user-friendliness of existing pressure-measuring devices. These devices often impact user comfort and convenience, which are crucial factors in the adoption and use of wearable devices. Potential solutions for pressure-measuring devices with promising technologies were proposed: four feasible alternative sensors are described that could improve comfort and facilitate prolonged use under bandages. Advanced communication technologies may provide more convenience for users and practitioners. CONCLUSIONS Conventional pressure-measuring devices used in compression therapy are not designed for the user's comfort and convenience. The use of flexible and stretchy pressure sensors (e-skin) provides good biocompatibility, conformability, and comfort and when integrated with near-field communication technology could address the drawbacks of current pressure-measuring devices.
Collapse
Affiliation(s)
- Rungphet Kruanopparat
- Rungphet Kruanopparat, MSc, OTR, is Occupational Therapist, Sirindhorn National Medical Rehabilitation Institute, Nonthaburi, Thailand. The author has disclosed no financial relationships related to this article. Submitted January 11, 2021; accepted in revised form February 16, 2021
| |
Collapse
|
4
|
Herbal Prescription SH003 Alleviates Docetaxel-Induced Neuropathic Pain in C57BL/6 Mice. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE 2021; 2021:4120334. [PMID: 34422067 PMCID: PMC8373497 DOI: 10.1155/2021/4120334] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Accepted: 08/04/2021] [Indexed: 12/18/2022]
Abstract
Docetaxel-based therapy has been applied to kill cancers including lung and breast cancers but frequently causes peripheral neuropathy such as mechanical allodynia. Lack of effective drugs for chemotherapy-induced peripheral neuropathy (CIPN) treatment leads us to find novel drugs. Here, we investigated whether and how novel anticancer herbal prescription SH003 alleviates mechanical allodynia in mouse model of docetaxel-induced neuropathic pain. Docetaxel-induced mechanical allodynia was evaluated using von Frey filaments. Nerve damage and degeneration in paw skin of mice were investigated by immunofluorescence staining. Neuroinflammation markers in bloodstream, lumbar (L4-L6) spinal cord, and sciatic nerves were examined by ELISA or western blot analysis. Docetaxel (15.277 mg/kg) was intravenously injected into the tail vein of C57BL/6 mice, and mechanical allodynia was followed up. SH003 (557.569 mg/kg) was orally administered at least 60 min before the mechanical allodynia test, and von Frey test was performed twice. Docetaxel injection induced mechanical allodynia, and SH003 administration restored withdrawal threshold. Meanwhile, degeneration of intraepidermal nerve fibers (IENF) was observed in docetaxel-treated mice, but SH003 treatment suppressed it. Moreover, docetaxel injection increased levels of TNF-α and IL-6 in plasma and expressions of phospho-NF-κB and phospho-STAT3 in both of lumbar spinal cord and sciatic nerves, while SH003 treatment inhibited those changes. Taken together, it is worth noting that TNF-α and IL-6 in plasma and phospho-NF-κB and phospho-STAT3 in spinal cord and sciatic nerves are putative biomarkers of docetaxel-induced peripheral neuropathy (DIPN) in mouse models. In addition, we suggest that SH003 would be beneficial for alleviation of docetaxel-induced neuropathic pain.
Collapse
|
5
|
Flexible Wireless Passive LC Pressure Sensor with Design Methodology and Cost-Effective Preparation. MICROMACHINES 2021; 12:mi12080976. [PMID: 34442598 PMCID: PMC8399622 DOI: 10.3390/mi12080976] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 08/10/2021] [Accepted: 08/11/2021] [Indexed: 11/17/2022]
Abstract
Continuous monitoring of physical motion, which can be successfully achieved via a wireless flexible wearable electronic device, is essential for people to ensure the appropriate level of exercise. Currently, most of the flexible LC pressure sensors have low sensitivity because of the high Young’s modulus of the dielectric properties (such as PDMS) and the inflexible polymer films (as the substrate of the sensors), which don’t have excellent stretchability to conform to arbitrarily curved and moving surfaces such as joints. In the LC sensing system, the metal rings, as the traditional readout device, are difficult to meet the needs of the portable readout device for the integrated and planar readout antenna. In order to improve the pressure sensitivity of the sensor, the Ecoflex microcolumn used as the dielectric of the capacitive pressure sensor was prepared by using a metal mold copying method. The Ecoflex elastomer substrates enhanced the levels of conformability, which offered improved capabilities to establish intimate contact with the curved and moving surfaces of the skin. The pressure was applied to the sensor by weights, and the resonance frequency curves of the sensor under different pressures were obtained by the readout device connected to the vector network analyzer. The experimental results show that resonant frequency decreases linearly with the increase of applied pressure in a range of 0–23,760 Pa with a high sensitivity of −2.2 MHz/KPa. We designed a coplanar waveguide-fed monopole antenna used to read the information of the LC sensor, which has the potential to be integrated with RF signal processing circuits as a portable readout device and a higher vertical readout distance (up to 4 cm) than the copper ring. The flexible LC pressure sensor can be attached to the skin conformally and is sensitive to limb bending and facial muscle movements. Therefore, it has the potential to be integrated as a body sensor network that can be used to monitor physical motion.
Collapse
|
6
|
O'Callaghan S, Galvin P, O'Mahony C, Moore Z, Derwin R. 'Smart' wound dressings for advanced wound care: a review. J Wound Care 2021; 29:394-406. [PMID: 32654609 DOI: 10.12968/jowc.2020.29.7.394] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Hard-to-heal wounds are a common side-effect of diabetes, obesity, pressure ulcers and age-related vascular diseases, the incidences of which are growing worldwide. The increasing financial burden of hard-to-heal wounds on global health services has provoked technological research into improving wound diagnostics and therapeutics via 'smart' dressings, within which elements such as microelectronic sensors, microprocessors and wireless communication radios are embedded. This review highlights the progress being made by research groups worldwide in producing 'smart' wound device prototypes. Significant advances have been made, for example, flexible substrates have replaced rigid circuit boards, sensors have been printed on commercial wound dressing materials and wireless communication has been demonstrated. Challenges remain, however, in the areas of power supply, disposability, low-profile components, multiparametric sensing and seamless device integration in commercial wound dressings.
Collapse
Affiliation(s)
- Suzanne O'Callaghan
- Department of Life Sciences Interface, Tyndall National Institute, University College Cork, Ireland
| | - Paul Galvin
- Department of Life Sciences Interface, Tyndall National Institute, University College Cork, Ireland
| | - Conor O'Mahony
- Department of Life Sciences Interface, Tyndall National Institute, University College Cork, Ireland
| | - Zena Moore
- Royal College of Surgeons in Ireland, School of Nursing, 123 St. Stephen's Green, Dublin 2 Dublin, Ireland.,Monash University, Melbourne, Australia.,Ghent University, Belgium.,Lida Institute, Shanghai, China.,University of Wales, Cardiff, Wales
| | - Rosemarie Derwin
- Royal College of Surgeons in Ireland, School of Nursing, 123 St. Stephen's Green, Dublin 2 Dublin, Ireland
| |
Collapse
|
7
|
Barros Almeida I, Garcez Barretto Teixeira L, Oliveira de Carvalho F, Ramos Silva É, Santos Nunes P, Viana Dos Santos MR, Antunes de Souza Araújo A. Smart Dressings for Wound Healing: A Review. Adv Skin Wound Care 2021; 34:1-8. [PMID: 33443918 DOI: 10.1097/01.asw.0000725188.95109.68] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
OBJECTIVE To provide an overview of sensors incorporated into wound dressings that can be used to assess and manage healing parameters. DATA SOURCES Authors conducted an extensive literature search of the Science Direct, Scopus, MEDLINE-PubMed, and Web of Science databases. STUDY SELECTION A total of 587 studies that evaluated dressings used to manage wound healing parameters were identified in the search, but only 16 met all of the review criteria and were included in the final analysis. DATA EXTRACTION Chronic wounds were the most common type of injury among studies. Six articles involved a wireless transmission system. DATA SYNTHESIS All studies evaluated the physical and chemical characteristics of the dressings. CONCLUSIONS This review demonstrates the lack of studies examining wound dressing sensors. New studies are required to assess sensors that allow not only wound monitoring, but also the application of drugs in a single dressing, providing a better and more cost-effective treatment for wounds.
Collapse
Affiliation(s)
- Isabella Barros Almeida
- At the Federal University of Sergipe, Sanatório, Aracaju, Brazil, Isabella Barros Almeida, PhD, is a physician; Luciana Garcez Barretto Teixeira, MS, is a doctoral student; Fernanda Oliveira de Carvalho, PhD, is a physiotherapist; Érika Ramos Silva, PhD, is Professor, Department of Physiotherapy; Paula Santos Nunes, PhD, is Professor, Department of Morphology; Márcio Roberto Viana dos Santos, PhD, is Professor, Department of Morphology; and Adriano Antunes de Souza Araújo, PhD, is Professor, Department of Pharmacy. The authors have disclosed no financial relationships related to this article. Submitted July 19, 2020; accepted in revised form September 25, 2020
| | | | | | | | | | | | | |
Collapse
|
8
|
Thin-Film Flexible Wireless Pressure Sensor for Continuous Pressure Monitoring in Medical Applications. SENSORS 2020; 20:s20226653. [PMID: 33233742 PMCID: PMC7699851 DOI: 10.3390/s20226653] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 11/15/2020] [Accepted: 11/17/2020] [Indexed: 11/16/2022]
Abstract
Physiological pressure measurement is one of the most common applications of sensors in healthcare. Particularly, continuous pressure monitoring provides key information for early diagnosis, patient-specific treatment, and preventive healthcare. This paper presents a thin-film flexible wireless pressure sensor for continuous pressure measurement in a wide range of medical applications but mainly focused on interface pressure monitoring during compression therapy to treat venous insufficiency. The sensor is based on a pressure-dependent capacitor (C) and printed inductive coil (L) that form an inductor-capacitor (LC) resonant circuit. A matched reader coil provides an excellent coupling at the fundamental resonance frequency of the sensor. Considering varying requirements of venous ulceration, two versions of the sensor, with different sizes, were finalized after design parameter optimization and fabricated using a cost-effective and simple etching method. A test setup consisting of a glass pressure chamber and a vacuum pump was developed to test and characterize the response of the sensors. Both sensors were tested for a narrow range (0–100 mmHg) and a wide range (0–300 mmHg) to cover most of the physiological pressure measurement applications. Both sensors showed good linearity with high sensitivity in the lower pressure range <100 mmHg, providing a wireless monitoring platform for compression therapy in venous ulceration.
Collapse
|
9
|
Hosseini E, Manjakkal L, Shakthivel D, Dahiya R. Glycine-Chitosan-Based Flexible Biodegradable Piezoelectric Pressure Sensor. ACS APPLIED MATERIALS & INTERFACES 2020; 12:9008-9016. [PMID: 32011853 PMCID: PMC7146751 DOI: 10.1021/acsami.9b21052] [Citation(s) in RCA: 94] [Impact Index Per Article: 23.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2019] [Accepted: 02/03/2020] [Indexed: 05/20/2023]
Abstract
This paper presents flexible pressure sensors based on free-standing and biodegradable glycine-chitosan piezoelectric films. Fabricated by the self-assembly of biological molecules of glycine within a water-based chitosan solution, the piezoelectric films consist of a stable spherulite structure of β-glycine (size varying from a few millimeters to 1 cm) embedded in an amorphous chitosan polymer. The polymorphic phase of glycine crystals in chitosan, evaluated by X-ray diffraction, confirms formation of a pure ferroelectric phase of glycine (β-phase). Our results show that a simple solvent-casting method can be used to prepare a biodegradable β-glycine/chitosan-based piezoelectric film with sensitivity (∼2.82 ± 0.2 mV kPa-1) comparable to those of nondegradable commercial piezoelectric materials. The measured capacitance of the β-glycine/chitosan film is in the range from 0.26 to 0.12 nF at a frequency range from 100 Hz to 1 MHz, and its dielectric constant and loss factor are 7.7 and 0.18, respectively, in the high impedance range under ambient conditions. The results suggest that the glycine-chitosan composite is a promising new biobased piezoelectric material for biodegradable sensors for applications in wearable biomedical diagnostics.
Collapse
Affiliation(s)
- Ensieh
S. Hosseini
- Bendable Electronics and
Sensing Technologies Group, James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, United Kingdom
| | - Libu Manjakkal
- Bendable Electronics and
Sensing Technologies Group, James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, United Kingdom
| | - Dhayalan Shakthivel
- Bendable Electronics and
Sensing Technologies Group, James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, United Kingdom
| | - Ravinder Dahiya
- Bendable Electronics and
Sensing Technologies Group, James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, United Kingdom
| |
Collapse
|
10
|
Mejzlik J, Skoloudik L, Cerny M, Ryska A, Radochova V, Pellantova V, Chrobok V. Use of a new pneumatic system to support capillary microperfusion in surgical wound healing: an animal model. J Wound Care 2019; 28:229-237. [PMID: 30975053 DOI: 10.12968/jowc.2019.28.4.229] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE To test the efficacy of the a developed medical device, based on the principle of mechanical support of capillary microperfusion. METHOD In this pilot study involving experimental animals, each pig had two standardised surgical wounds. A cuff that delivered pneumatic three-second micropulses was applied to the wound designated as the 'experimental wound'. The pressure inside the cuff was kept at a level <10mmHg so that during the pulse, the pressure would decrease by one third of the established value. The second wound, designated as the 'control wound', was covered with a standard dressing. Over the course of five days, the pressure inside the cuff was monitored. After the five days, the experimental animal was euthanised and two specimens were collected for histological analysis (one sample from each wound site). Wound healing parameters for the experimental and control wounds were examined by a pathologist. The level of statistical significance was set at 0.05. RESULTS In this study, 10 experimental animals were used. The average pressure in the cuffs was 8.46mmHg (standard deviation: 3.86). No disparities in wound healing were observed in cases of different average pressures in the experimental wound. With respect to wound healing parameters, a statistically significant difference (p<0.05) was found in favour of the experimental wound. The occurrence of histological signs of poor healing was identical in both study wounds. CONCLUSION The study shows that a device for the support of capillary microperfusion of the surgical wound had a positive effect. It was confirmed that the mechanical support system of capillary microperfusion was safe and reliable.
Collapse
Affiliation(s)
- Jan Mejzlik
- Department of Otorhinolaryngology and Head and Neck Surgery, University Hospital Hradec Kralove, Charles University, Faculty of Medicine in Hradec Kralove, Czech Republic
| | - Lukas Skoloudik
- Department of Otorhinolaryngology and Head and Neck Surgery, University Hospital Hradec Kralove, Charles University, Faculty of Medicine in Hradec Kralove, Czech Republic
| | - Michal Cerny
- Department of Otorhinolaryngology and Head and Neck Surgery, University Hospital Hradec Kralove, Charles University, Faculty of Medicine in Hradec Kralove, Czech Republic
| | - Ales Ryska
- Fingerland's institute of Pathology, University Hospital Hradec Kralove, Charles University, Faculty of Medicine in Hradec Kralove, Czech Republic
| | - Vera Radochova
- Vivarium, Faculty of Military Health Sciences, University of Defence, Brno, Czech Republic
| | - Vera Pellantova
- Department of Infectious Diseases, University Hospital Hradec Kralove, Charles University, Faculty of Medicine in Hradec Kralove, Czech Republic
| | - Viktor Chrobok
- Department of Otorhinolaryngology and Head and Neck Surgery, University Hospital Hradec Kralove, Charles University, Faculty of Medicine in Hradec Kralove, Czech Republic
| |
Collapse
|
11
|
Haalboom M. Chronic Wounds: Innovations in Diagnostics and Therapeutics. Curr Med Chem 2019; 25:5772-5781. [PMID: 28699502 DOI: 10.2174/0929867324666170710120556] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 06/10/2017] [Accepted: 06/10/2017] [Indexed: 12/14/2022]
Abstract
BACKGROUND A major global health issue is the existence of chronic wounds. Appropriate diagnosis and treatment is essential to promote wound healing and prevent further complications. Traditional methods for treatment and diagnosis of chronic wounds have shown to be of limited effectiveness. Therefore, there is a need for the development of diagnostic and therapeutic innovations in chronic wound care. OBJECTIVE This mini-review aims to provide insight in the current knowledge of the wound healing process and the deficiencies encountered in chronic wounds, which provides a basis for the development of innovations in chronic wound care. Furthermore, promising diagnostic and therapeutic innovations will be highlighted. METHODS Literature was searched for recent articles (=<10 years) describing the current knowledge about the wound healing process and chronic wounds. The most promising diagnostic and therapeutic innovations were gathered from articles published in the past 5 years. RESULTS/CONCLUSION Wound healing is a well-organized process consisting of four phases: coagulation, inflammation, proliferation and wound remodelling. Chronic wounds often stagnate in the inflammatory phase and/or experience an impaired proliferative phase. This mini-review has demonstrated that increased knowledge about the processes involved in wound healing has paved the way for the development of new diagnostic tools and treatments for chronic wounds. Increased knowledge about bacterial invasion and infection in has encouraged researchers to develop diagnostic tools to help clinicians detect these phenomena appropriately and in time. Other researchers have shown that they are able to design/extract biochemical compounds that intervene in the disrupted healing processes in chronic wounds.
Collapse
Affiliation(s)
- Marieke Haalboom
- Department of Vascular Surgery/Medical School Twente, Medisch Spectrum Twente, Enschede, Netherlands
| |
Collapse
|
12
|
Sermsathanasawadi N, Tarapongpun T, Pianchareonsin R, Puangpunngam N, Wongwanit C, Chinsakchai K, Mutirangura P, Ruangsetakit C. Customizing elastic pressure bandages for reuse to a predetermined, sub-bandage pressure: A randomized controlled trial. Phlebology 2017; 33:627-635. [DOI: 10.1177/0268355517746434] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Objective A randomized clinical trial was performed to compare the effectiveness of unmarked bandages and customized bandages with visual markers in reproducing the desired sub-bandage pressure during self-bandaging by patients. Method Ninety patients were randomly allocated to two groups (“customized bandages” and “unmarked bandages”) and asked to perform self-bandaging three times. The achievement of a pressure between 35 and 45 mmHg in at least two of the three attempts was defined as adequate quality. Results Adequate quality was achieved by 33.0% when applying the unmarked bandages, and 60.0% when applying the customized bandages ( p = 0.02). Use of the customized bandage and previous experience of bandaging were independent predictors for the achievement of the predetermined sub-bandage pressure ( p = 0.005 and p = 0.021, respectively). Conclusion Customized bandages may achieve predetermined sub-bandage pressures more closely than standard, unmarked, compression bandages. Clinical trials registration ClinicalTrials.gov (NCT02729688). Effectiveness of a Pressure Indicator Guided and a Conventional Bandaging in Treatment of Venous Leg Ulcer. https://clinicaltrials.gov/ct2/show/NCT02729688
Collapse
Affiliation(s)
- Nuttawut Sermsathanasawadi
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Tanakorn Tarapongpun
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Rattana Pianchareonsin
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Nattawut Puangpunngam
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Chumpol Wongwanit
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Khamin Chinsakchai
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Pramook Mutirangura
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Chanean Ruangsetakit
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| |
Collapse
|
13
|
Khodasevych I, Parmar S, Troynikov O. Flexible Sensors for Pressure Therapy: Effect of Substrate Curvature and Stiffness on Sensor Performance. SENSORS (BASEL, SWITZERLAND) 2017; 17:E2399. [PMID: 29053605 PMCID: PMC5676615 DOI: 10.3390/s17102399] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 10/10/2017] [Accepted: 10/17/2017] [Indexed: 11/25/2022]
Abstract
Flexible pressure sensors are increasingly being used in medical and non-medical applications, and particularly in innovative health monitoring. Their efficacy in medical applications such as compression therapy depends on the accuracy and repeatability of their output, which in turn depend on factors such as sensor type, shape, pressure range, and conformability of the sensor to the body surface. Numerous researchers have examined the effects of sensor type and shape, but little information is available on the effect of human body parameters such as support surfaces' curvature and the stiffness of soft tissues on pressure sensing performance. We investigated the effects of body parameters on the performance of pressure sensors using a custom-made human-leg-like test setup. Pressure sensing parameters such as accuracy, drift and repeatability were determined in both static (eight hours continuous pressure) and dynamic (10 cycles of pressure application of 30 s duration) testing conditions. The testing was performed with a focus on compression therapy application for venous leg ulcer treatments, and was conducted in a low-pressure range of 20-70 mmHg. Commercially available sensors manufactured by Peratech and Sensitronics were used under various loading conditions to determine the influence of stiffness and curvature. Flat rigid, flat soft silicone and three cylindrical silicone surfaces of radii of curvature of 3.5 cm, 5.5 cm and 6.5 cm were used as substrates under the sensors. The Peratech sensor averaged 94% accuracy for both static and dynamic measurements on all substrates; the Sensitronics sensor averaged 88% accuracy. The Peratech sensor displayed moderate variations and the Sensitronics sensor large variations in output pressure readings depending on the underlying test surface, both of which were reduced markedly by individual pressure calibration for surface type. Sensor choice and need for calibration to surface type are important considerations for their application in healthcare monitoring.
Collapse
Affiliation(s)
- Iryna Khodasevych
- School of Fashion and Textiles, Royal Melbourne Institute of Technology, Melbourne 3056, Australia.
| | - Suresh Parmar
- School of Fashion and Textiles, Royal Melbourne Institute of Technology, Melbourne 3056, Australia.
| | - Olga Troynikov
- School of Fashion and Textiles, Royal Melbourne Institute of Technology, Melbourne 3056, Australia.
| |
Collapse
|
14
|
Sermsathanasawadi N, Chatjaturapat C, Pianchareonsin R, Puangpunngam N, Wongwanit C, Chinsakchai K, Ruangsetakit C, Mutirangura P. Use of customised pressure-guided elastic bandages to improve efficacy of compression bandaging for venous ulcers. Int Wound J 2016; 14:636-640. [PMID: 27502619 DOI: 10.1111/iwj.12656] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2016] [Revised: 07/08/2016] [Accepted: 07/10/2016] [Indexed: 11/30/2022] Open
Abstract
Compression bandaging is a major treatment of chronic venous ulcers. Its efficacy depends on the applied pressure, which is dependent on the skill of the individual applying the bandage. To improve the quality of bandaging by reducing the variability in compression bandage interface pressures, we changed elastic bandages into a customised version by marking them with circular ink stamps, applied when the stretch achieves an interface pressure between 35 and 45 mmHg. Repeated applications by 20 residents of the customised bandage and non-marked bandage to one smaller and one larger leg were evaluated by measuring the sub-bandage pressure. The results demonstrated that the target pressure range is more often attained with the customised bandage compared with the non-marked bandage. The customised bandage improved the efficacy of compression bandaging for venous ulcers, with optimal sub-bandage pressure.
Collapse
Affiliation(s)
- Nuttawut Sermsathanasawadi
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Choedpong Chatjaturapat
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Rattana Pianchareonsin
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Nattawut Puangpunngam
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Chumpol Wongwanit
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Khamin Chinsakchai
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Chanean Ruangsetakit
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Pramook Mutirangura
- Division of Vascular Surgery, Department of Surgery, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| |
Collapse
|
15
|
Farooqui MF, Shamim A. Low Cost Inkjet Printed Smart Bandage for Wireless Monitoring of Chronic Wounds. Sci Rep 2016; 6:28949. [PMID: 27353200 PMCID: PMC4926082 DOI: 10.1038/srep28949] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2015] [Accepted: 06/07/2016] [Indexed: 11/26/2022] Open
Abstract
Chronic wounds affect millions of patients around the world and their treatment is challenging as the early signs indicating their development are subtle. In addition, a type of chronic wound, known as pressure ulcer, develops in patients with limited mobility. Infection and frequent bleeding are indicators of chronic wound development. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage, which can send early warnings for the parameters like irregular bleeding, variations in pH levels and external pressure at wound site. In addition to the early warnings, this smart bandage concept can provide long term wound progression data to the health care providers. The smart bandage comprises a disposable part which has the inkjet printed sensors and a reusable part constituting the wireless electronics. This work is an important step towards futuristic wearable sensors for remote health care applications.
Collapse
Affiliation(s)
- Muhammad Fahad Farooqui
- Electrical Engineering Program, 4700 King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Saudi Arabia
| | - Atif Shamim
- Electrical Engineering Program, 4700 King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Saudi Arabia
| |
Collapse
|
16
|
Mostafalu P, Lenk W, Dokmeci MR, Ziaie B, Khademhosseini A, Sonkusale SR. Wireless Flexible Smart Bandage for Continuous Monitoring of Wound Oxygenation. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2015; 9:670-677. [PMID: 26552096 DOI: 10.1109/tbcas.2015.2488582] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Current methods in treating chronic wounds have had limited success in large part due to the open loop nature of the treatment. We have created a localized 3D-printed smart wound dressing platform that will allow for real-time data acquisition of oxygen concentration, which is an important indicator of wound healing. This will serve as the first leg of a feedback loop for a fully optimized treatment mechanism tailored to the individual patient. A flexible oxygen sensor was designed and fabricated with high sensitivity and linear current output. With a series of off-the-shelf electronic components including a programmable-gain analog front-end, a microcontroller and wireless radio, an integrated electronic system with data readout and wireless transmission capabilities was assembled in a compact package. Using an elastomeric material, a bandage with exceptional flexibility and tensile strength was 3D-printed. The bandage contains cavities for both the oxygen sensor and the electronic systems, with contacts interfacing the two systems. Our integrated, flexible platform is the first step toward providing a self-operating, highly optimized remote therapy for chronic wounds.
Collapse
|