1
|
Dip F, Bregoli P, Falco J, White KP, Rosenthal RJ. Nerve autofluorescence in near-ultraviolet light markedly enhances nerve visualization in vivo. Surg Endosc 2022; 36:1999-2005. [PMID: 33835251 DOI: 10.1007/s00464-021-08484-0/tables/3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Accepted: 03/28/2021] [Indexed: 05/26/2023]
Abstract
BACKGROUND During surgery, surgeons must accurately localize nerves to avoid injuring them. Recently, we have discovered that nerves fluoresce in near-ultraviolet light (NUV) light. The aims of the current study were to determine the extent to which nerves fluoresce more brightly than background and vascular structures in NUV light, and identify the NUV intensity at which nerves are most distinguishable from other tissues. METHODS We exposed sciatic nerves within the posterior thigh in five 250-300 gm Wistar rats, then observed them at four different NUV intensity levels: 20%, 35%, 50%, and 100%. Brightness of fluorescence was measured by fluorescence spectroscopy, quantified as a fluorescence score using Image-J software, and statistically compared between nerves, background, and both an artery and vein by unpaired Student's t tests with Bonferroni adjustment to accommodate multiple comparisons. Sensitivity, specificity, and accuracy were calculated for each NUV intensity. RESULTS At 20, 35, 50, and 100% NUV intensity, fluorescence scores for nerves versus background tissues were 117.4 versus 40.0, 225.8 versus 88.0, 250.6 versus 121.4, and 252.8 versus 169.4, respectively (all p < 0.001). Fluorescence scores plateaued at 50% NUV intensity for nerves, but continued to rise for background. At 35%, 50%, and 100% NUV intensity, a fluorescence score of 200 was 100% sensitive, specific, and accurate identifying nerves. At 100 NUV intensity, artery and vein scores were 61.8 and 60.0, both dramatically lower than for nerves (p < 0.001). CONCLUSIONS At all NUV intensities ≥ 35%, a fluorescence score of 200 is 100% accurate distinguishing nerves from other anatomical structures in vivo.
Collapse
Affiliation(s)
- Fernando Dip
- Instituto Argentino de Diagnóstico y Tratamiento, Universidad de Buenos Aires, Buenos Aires, Argentina
- Cleveland Clinic Florida, Weston, FL, 33325, USA
| | - Pedro Bregoli
- Instituto Argentino de Diagnóstico y Tratamiento, Universidad de Buenos Aires, Buenos Aires, Argentina
| | - Jorge Falco
- Instituto Argentino de Diagnóstico y Tratamiento, Universidad de Buenos Aires, Buenos Aires, Argentina
| | - Kevin P White
- ScienceRight Research Consulting, London, ON, Canada
| | - Raúl J Rosenthal
- Cleveland Clinic Florida, Weston, FL, 33325, USA.
- Cleveland Clinic Florida, 2950 Cleveland Clinic Blvd., Weston, FL, 33331, USA.
| |
Collapse
|
2
|
Dip F, Bregoli P, Falco J, White KP, Rosenthal RJ. Nerve autofluorescence in near-ultraviolet light markedly enhances nerve visualization in vivo. Surg Endosc 2021; 36:1999-2005. [PMID: 33835251 DOI: 10.1007/s00464-021-08484-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2020] [Accepted: 03/28/2021] [Indexed: 11/27/2022]
Abstract
BACKGROUND During surgery, surgeons must accurately localize nerves to avoid injuring them. Recently, we have discovered that nerves fluoresce in near-ultraviolet light (NUV) light. The aims of the current study were to determine the extent to which nerves fluoresce more brightly than background and vascular structures in NUV light, and identify the NUV intensity at which nerves are most distinguishable from other tissues. METHODS We exposed sciatic nerves within the posterior thigh in five 250-300 gm Wistar rats, then observed them at four different NUV intensity levels: 20%, 35%, 50%, and 100%. Brightness of fluorescence was measured by fluorescence spectroscopy, quantified as a fluorescence score using Image-J software, and statistically compared between nerves, background, and both an artery and vein by unpaired Student's t tests with Bonferroni adjustment to accommodate multiple comparisons. Sensitivity, specificity, and accuracy were calculated for each NUV intensity. RESULTS At 20, 35, 50, and 100% NUV intensity, fluorescence scores for nerves versus background tissues were 117.4 versus 40.0, 225.8 versus 88.0, 250.6 versus 121.4, and 252.8 versus 169.4, respectively (all p < 0.001). Fluorescence scores plateaued at 50% NUV intensity for nerves, but continued to rise for background. At 35%, 50%, and 100% NUV intensity, a fluorescence score of 200 was 100% sensitive, specific, and accurate identifying nerves. At 100 NUV intensity, artery and vein scores were 61.8 and 60.0, both dramatically lower than for nerves (p < 0.001). CONCLUSIONS At all NUV intensities ≥ 35%, a fluorescence score of 200 is 100% accurate distinguishing nerves from other anatomical structures in vivo.
Collapse
Affiliation(s)
- Fernando Dip
- Instituto Argentino de Diagnóstico y Tratamiento, Universidad de Buenos Aires, Buenos Aires, Argentina
- Cleveland Clinic Florida, Weston, FL, 33325, USA
| | - Pedro Bregoli
- Instituto Argentino de Diagnóstico y Tratamiento, Universidad de Buenos Aires, Buenos Aires, Argentina
| | - Jorge Falco
- Instituto Argentino de Diagnóstico y Tratamiento, Universidad de Buenos Aires, Buenos Aires, Argentina
| | - Kevin P White
- ScienceRight Research Consulting, London, ON, Canada
| | - Raúl J Rosenthal
- Cleveland Clinic Florida, Weston, FL, 33325, USA.
- Cleveland Clinic Florida, 2950 Cleveland Clinic Blvd., Weston, FL, 33331, USA.
| |
Collapse
|
3
|
Nerve spectroscopy: understanding peripheral nerve autofluorescence through photodynamics. Surg Endosc 2021; 35:7104-7111. [PMID: 33782757 DOI: 10.1007/s00464-020-08227-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Accepted: 12/03/2020] [Indexed: 12/16/2022]
Abstract
BACKGROUND Being able to accurately identify sensory and motor nerves is crucial during surgical procedures to prevent nerve injury. We aimed to (1) evaluate the feasibility of performing peripheral human nerve visualization utilizing nerves' own autofluorescence in an ex-vivo model; (2) compare the effect of three different nerve fiber fixation methods on the intensity of fluorescence, indicated as the intensity ratio; and (3) similarly compare three different excitation ranges. METHODS Samples from various human peripheral nerves were selected postoperatively. Nerve fibers were divided into three groups: Group A nerve fibers were washed with a physiologic solution; Group B nerve fibers were fixated with formaldehyde for 6 h first, and then washed with a physiologic solution; Group C nerve fibers were fixated with formaldehyde for six hours, but not washed afterwards. An Olympus IX83 inverted microscope was used for close-up image evaluation. Nerve fibers were exposed to white-light wavelength spectrums for a specific time frame prior to visualization under three different filters-Filter 1-LF405-B-OMF Semrock; Filter 2-U-MGFP; Filter 3-U-MRFPHQ Olympus, with excitation ranges of 390-440, 460-480, and 535-555, respectively. The fluorescence intensity of all images was subsequently analyzed using Image-J Software, and results compared by analysis of variance (ANOVA). RESULTS The intensity ratios observed with Filter 1 failed to distinguish the different nerve fiber groups (p = 0.39). Conversely, the intensity ratios seen under Filters 2 and 3 varied significantly between the three nerve-fiber groups (p = 0.021, p = 0.030, respectively). The overall intensity of measurements was greater with Filter 1 than Filter 3 (p < 0.05); however, all nerves were well visualized by all filters. CONCLUSION The current results on ex vivo peripheral nerve fiber autofluorescence suggest that peripheral nerve fiber autofluorescence intensity does not greatly depend upon the excitation wavelength or fixation methods used in an ex vivo setting. Implications for future nerve-sparing surgery are discussed.
Collapse
|
4
|
Stelzle F, Rohde M, Riemann M, Oetter N, Adler W, Tangermann-Gerk K, Schmidt M, Knipfer C. Autofluorescence spectroscopy for nerve-sparing laser surgery of the head and neck-the influence of laser-tissue interaction. Lasers Med Sci 2017; 32:1289-1300. [PMID: 28551764 DOI: 10.1007/s10103-017-2240-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2016] [Accepted: 05/18/2017] [Indexed: 11/30/2022]
Abstract
The use of remote optical feedback systems represents a promising approach for minimally invasive, nerve-sparing laser surgery. Autofluorescence properties can be exploited for a fast, robust identification of nervous tissue. With regard to the crucial step towards clinical application, the impact of laser ablation on optical properties in the vicinity of structures of the head and neck has not been investigated up to now. We acquired 24,298 autofluorescence spectra from 135 tissue samples (nine ex vivo tissue types from 15 bisected pig heads) both before and after ER:YAG laser ablation. Sensitivities, specificities, and area under curve(AUC) values for each tissue pair as well as the confusion matrix were statistically calculated for pre-ablation and post-ablation autofluorescence spectra using principal component analysis (PCA), quadratic discriminant analysis (QDA), and receiver operating characteristics (ROC). The confusion matrix indicated a highly successful tissue discrimination rate before laser exposure, with an average classification error of 5.2%. The clinically relevant tissue pairs nerve/cancellous bone and nerve/salivary gland yielded an AUC of 100% each. After laser ablation, tissue discrimination was feasible with an average classification accuracy of 92.1% (average classification error 7.9%). The identification of nerve versus cancellous bone and salivary gland performed very well with an AUC of 100 and 99%, respectively. Nerve-sparing laser surgery in the area of the head and neck by means of an autofluorescence-based feedback system is feasible even after ER-YAG laser-tissue interactions. These results represent a crucial step for the development of a clinically applicable feedback tool for laser surgery interventions in the oral and maxillofacial region.
Collapse
Affiliation(s)
- Florian Stelzle
- Department of Oral and Maxillofacial Surgery, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), University Hospital Erlangen, Glückstraße 11, 91054, Erlangen, Germany.,Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Paul-Gordan-Str. 6, 91052, Erlangen, Germany
| | - Maximilian Rohde
- Department of Oral and Maxillofacial Surgery, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), University Hospital Erlangen, Glückstraße 11, 91054, Erlangen, Germany.,Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Paul-Gordan-Str. 6, 91052, Erlangen, Germany
| | - Max Riemann
- Department of Oral and Maxillofacial Surgery, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), University Hospital Erlangen, Glückstraße 11, 91054, Erlangen, Germany
| | - Nicolai Oetter
- Department of Oral and Maxillofacial Surgery, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), University Hospital Erlangen, Glückstraße 11, 91054, Erlangen, Germany
| | - Werner Adler
- Department of Medical Informatics, Biometry and Epidemiology, Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Waldstraße 6, 91054, Erlangen, Germany
| | | | - Michael Schmidt
- Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Paul-Gordan-Str. 6, 91052, Erlangen, Germany.,Bavarian Laser Center GmbH (blz), Konrad-Zuse-Straße 2-6, 91054, Erlangen, Germany.,Institute of Photonic Technologies, Friedrich-Alexander-University Erlangen-Nürnberg(FAU), Konrad-Zuse-Straße 3-5, 91052, Erlangen, Germany
| | - Christian Knipfer
- Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-University Erlangen-Nürnberg (FAU), Paul-Gordan-Str. 6, 91052, Erlangen, Germany. .,Department of Oral and Maxillofacial Surgery, University of Hamburg (UHH), University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
| |
Collapse
|
5
|
Zhou X, Jiang Y, Zhao X, Guo D. ESIPT-Based Photoactivatable Fluorescent Probe for Ratiometric Spatiotemporal Bioimaging. SENSORS 2016; 16:s16101684. [PMID: 27754338 PMCID: PMC5087472 DOI: 10.3390/s16101684] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/24/2016] [Revised: 09/20/2016] [Accepted: 09/22/2016] [Indexed: 11/16/2022]
Abstract
Photoactivatable fluorophores have become an important technique for the high spatiotemporal resolution of biological imaging. Here, we developed a novel photoactivatable probe (PHBT), which is based on 2-(2-hydroxyphenyl)benzothiazole (HBT), a small organic fluorophore known for its classic luminescence mechanism through excited-state intramolecular proton transfer (ESIPT) with the keto form and the enol form. After photocleavage, PHBT released a ratiometric fluorophore HBT, which showed dual emission bands with more than 73-fold fluorescence enhancement at 512 nm in buffer and more than 69-fold enhancement at 452 nm in bovine serum. The probe displayed a high ratiometric imaging resolution and is believed to have a wide application in biological imaging.
Collapse
Affiliation(s)
- Xiaohong Zhou
- College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China.
- Environment Monitoring Department, Changsha Environmental Protection College, Changsha 410004, China.
| | - Yuren Jiang
- College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China.
| | - Xiongjie Zhao
- College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China.
| | - Dong Guo
- College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China.
| |
Collapse
|